ENS 51731: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 02/11/2016 CST
| event date = 02/11/2016 CST
| last update date = 02/12/2016
| last update date = 02/12/2016
| title = Agreement State Report - Fixed Gauge Shutter Found In Stuck Open Position
| title = Agreement State Report - Fixed Gauge Shutter Found in Stuck Open Position
| event text = The following information was provided by the State of Texas via email:
| event text = The following information was provided by the State of Texas via email:
On February 12, 2016, the Agency [Texas Department of State Health Services] was notified by the licensee's radiation safety officer (RSO) that on February 11, 2016, while performing a routine inspection of a Berthold model LB 300 l nuclear gauge, they found the source shutter was stuck in the open position. Open is the normal position for the gauge shutter. The gauge contains a one millicurie (original activity, current activity 0.07 mCi.) Cobalt-60 source. The RSO stated the dose rates at and around the gauge are normal. He [the RSO] stated no individuals, including members of the general public, will be exposed to any additional radiation due to the failure. The RSO stated the manufacturer has been contacted and will be at the licensee's facility the week of February 15, 2016 to fix or replace the gauge. Additional information will be provided as it is received in accordance with SA-300.
On February 12, 2016, the Agency [Texas Department of State Health Services] was notified by the licensee's radiation safety officer (RSO) that on February 11, 2016, while performing a routine inspection of a Berthold model LB 300 l nuclear gauge, they found the source shutter was stuck in the open position. Open is the normal position for the gauge shutter. The gauge contains a one millicurie (original activity, current activity 0.07 mCi.) Cobalt-60 source. The RSO stated the dose rates at and around the gauge are normal. He [the RSO] stated no individuals, including members of the general public, will be exposed to any additional radiation due to the failure. The RSO stated the manufacturer has been contacted and will be at the licensee's facility the week of February 15, 2016 to fix or replace the gauge. Additional information will be provided as it is received in accordance with SA-300.

Latest revision as of 20:45, 1 March 2018

ENS 51731 +/-
Where
Covestro Llc
Baytown, Texas (NRC Region 4)
License number: 01577
Organization: Texas Dept Of State Health Services
Reporting
Agreement State
Time - Person (Reporting Time:+31.12 h1.297 days <br />0.185 weeks <br />0.0426 months <br />)
Opened: Art Tucker
13:07 Feb 12, 2016
NRC Officer: Steve Sandin
Last Updated: Feb 12, 2016
51731 - NRC Website