ENS 52395: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 11/27/2016 00:26 CST
| event date = 11/27/2016 00:26 CST
| last update date = 11/27/2016
| last update date = 11/27/2016
| title = Manual Reactor Trip With Automatic Auxiliary Feedwater System Actuation Due To Voltage Oscillations
| title = Manual Reactor Trip with Automatic Auxiliary Feedwater System Actuation Due to Voltage Oscillations
| event text = At 0026 [CST] on November 27, 2016, Farley Unit 1 was manually tripped from 100% reactor power due to voltage swings suspected to be caused by the Auto Voltage Regulator. All control rods fully inserted and Auxiliary Feedwater (AFW) auto-started as expected.
| event text = At 0026 [CST] on November 27, 2016, Farley Unit 1 was manually tripped from 100% reactor power due to voltage swings suspected to be caused by the Auto Voltage Regulator. All control rods fully inserted and Auxiliary Feedwater (AFW) auto-started as expected.
All systems responded as expected. The plant is currently stable in Mode 3 (Hot Standby). The cause of the main generator voltage oscillations is under investigation.
All systems responded as expected. The plant is currently stable in Mode 3 (Hot Standby). The cause of the main generator voltage oscillations is under investigation.

Latest revision as of 20:43, 1 March 2018

ENS 52395 +/-
Where
Farley Southern Nuclear icon.png
Alabama (NRC Region 2)
Reporting
10 CFR 50.72(b)(2)(iv)(B), RPS Actuation

10 CFR 50.72(b)(3)(iv)(A), System Actuation
Time - Person (Reporting Time:+-3.3 h-0.138 days <br />-0.0196 weeks <br />-0.00452 months <br />)
Opened: Blake Mitchell
03:08 Nov 27, 2016
NRC Officer: Howie Crouch
Last Updated: Nov 27, 2016
52395 - NRC Website
Loading map...