{{#Wiki_filter:PART 1 PUMP TESTING PROGRAM The following pumps will be tested in accordance with Article IWP, Section XI of the ASME Boiler and Pressure Vessel Code.
{{#Wiki_filter:PART 1 PUMP TESTING PROGRAM The following pumps will be tested in accordance with Article IWP, Section XI of the ASME Boiler and Pressure Vessel Code.
PUMP                                                   DRAWING NUMBER Auxiliary Feed                   21, 22, and 23         205336 Boric Acid Transfer             21 and 22             205328 Chilled Water                   21 and 22             205316 Charging                         23                     205328 Charging and Safety Injection   21 and 22             205328 and 205334 Containment Spray               21 and 22             205335 Component Cooling               21, 22 and 23         205331 Residual Heat Removal           21 and 22             205332 Safety Injection                 21 and 22             205334 Service Water                   21, 22, 23, 24, 25     205342 and 26 Page 1 of 95                           Rev. 0
PUMP DRAWING NUMBER Auxiliary Feed 21, 22, and 23 205336 Boric Acid Transfer 21 and 22 205328 Chilled Water 21 and 22 205316 Charging 23 205328 Charging and Safety Injection 21 and 22 205328 and 205334 Containment Spray 21 and 22 205335 Component Cooling 21, 22 and 23 205331 Residual Heat Removal 21 and 22 205332 Safety Injection 21 and 22 205334 Service Water 21, 22, 23, 24, 25 205342 and 26 Page 1 of 95 Rev. 0  


PART 2 VALVE TESTING PROGRAM INDEX ITEM                                                       PAGE NUMBER
PART 2 VALVE TESTING PROGRAM INDEX ITEM
: 1. Abbreviations                                             3
: 1.
: 2. Key to Test Requirement                                   5
Abbreviations
: 3. Operational Modes                                         6
: 2.
: 4. List of Effective Pages                                   7
Key to Test Requirement
: 5. Valve Listings and Relief Requests by Systems Auxiliary Feed System (AF)                               8 Steam Generator Feed Pump and Condensate (BF)           13 Chemical and Volume Control (CVC-OPS)                   15 Chilled Water (CH)                                       24 Component Cooling (CC)                                   25 Containment Spray (CS)                                   30 Control Air (CA)                                         33 Demineralized Water - Restricted (DR)                     35 Fire Protection (FP)                                     37 Fuel Transfer System                                     39 Steam Generator Drain and Blowdown (GB)                   40 Main Steam (MS)                                           42 Nitrogen (NT)                                             47 Reactor Coolant (RC, PR)                                 49 Residual Heat Removal (RH)                               51 Safety Injection (SJ)                                     54 Sampling (SS)                                             66 Service Water (SW)                                       70 Spent Fuel Cooling (SF)                                   83 Station Air (Compressed Air - SA)                         85 Ventilation Containment (VC)                             87 Waste Disposal Liquid (WL)                               90 Water Recovery (WR-CVC)                                   93 Page 2 of 95               Rev. 0
: 3.
Operational Modes
: 4.
List of Effective Pages
: 5.
Valve Listings and Relief Requests by Systems Auxiliary Feed System (AF)
Steam Generator Feed Pump and Condensate (BF)
Chemical and Volume Control (CVC-OPS)
Chilled Water (CH)
Component Cooling (CC)
Containment Spray (CS)
Control Air (CA)
Demineralized Water - Restricted (DR)
Fire Protection (FP)
Fuel Transfer System Steam Generator Drain and Blowdown (GB)
Main Steam (MS)
Nitrogen (NT)
Reactor Coolant (RC, PR)
Residual Heat Removal (RH)
Safety Injection (SJ)
Sampling (SS)
Service Water (SW)
Spent Fuel Cooling (SF)
Station Air (Compressed Air -
SA)
Ventilation Containment (VC)
Waste Disposal Liquid (WL)
Water Recovery (WR-CVC)
Page 2 of 95 PAGE NUMBER 3
5 6
7 8
13 15 24 25 30 33 35 37 39 40 42 47 49 51 54 66 70 83 85 87 90 93 Rev. 0  


PART 2 ITEM 1 ABBREVIATIONS
PART 2 ITEM 1 ABBREVIATIONS
: 1. Valve Identification AF     Auxiliary Feed BF     Stearn Generator Feed CVC   Chemical and Volume Control CH     Chilled Water CC     Component Cooling CS     Containment Spray CA     Control Air DR     Dernineralized Water - Restricted Area FP     Fire Protection Fuel Transfer System GB     Stearn Generator Drain and Blowdown MS     Main Stearn NT     Nitrogen RC,PR Reactor Coolant, Pressurizer Relief RH     Residual Heat Removal SJ     Safety Injection SS     Sampling SW     Service Water - Nuclear SF     Spent Fuel Cooling SA     Station Air (Compressed Air)
: 1.
VC     Ventilation Containment WL     WasteDisposal - Liquid WR     Water Recovery (Chemical and Volume Control)
Valve Identification AF Auxiliary Feed BF Stearn Generator Feed CVC Chemical and Volume Control CH Chilled Water CC Component Cooling CS Containment Spray CA Control Air DR Dernineralized Water - Restricted Area FP Fire Protection Fuel Transfer System GB Stearn Generator Drain and Blowdown MS Main Stearn NT Nitrogen RC,PR Reactor Coolant, Pressurizer Relief RH Residual Heat Removal SJ Safety Injection SS Sampling SW Service Water - Nuclear SF Spent Fuel Cooling SA Station Air (Compressed Air)
: 2. Valve Type BFY   Butterfly CK     Check DIA   Diaphragm DCK   Double Check GA     Gate GL     Globe NE     Needle PL     Plug REL   Relief SAF   Safety SCK   Stop Check 3 WAY Page 3 of 95 Rev. 0
VC Ventilation Containment WL WasteDisposal - Liquid WR Water Recovery (Chemical and Volume Control)
: 2.
Valve Type BFY Butterfly CK Check DIA Diaphragm DCK Double Check GA Gate GL Globe NE Needle PL Plug REL Relief SAF Safety SCK Stop Check 3 WAY Page 3 of 95 Rev. 0  


PART 2 ITEM 1 Actuator Type A     Air HYD   Hydraulic M     Manual MO     Motor Operated SA     Self Actuated SOL   Solenoid STM   Steam H/S   Hydraulic and Steam
PART 2 ITEM 1 Actuator Type A
: 4. Normal Position AUTO   Automatic C     Closed COOL   Ported to Coolers LC     Locked Closed LO     Locked Open L.TH. Locked Throttled MOD   Modulating O     Open PER   Stop Check with Valve Stem Backed Off.
Air HYD Hydraulic M
REG   Regulating TH     Throttled VCT   Ported to the Volume Control Tank Page 4 of 95 Rev. 0
Manual MO Motor Operated SA Self Actuated SOL Solenoid STM Steam H/S Hydraulic and Steam
: 4.
Normal Position AUTO Automatic C
Closed COOL Ported to Coolers LC Locked Closed LO Locked Open L.TH.
Locked Throttled MOD Modulating O
Open PER Stop Check with Valve Stem Backed Off.
REG Regulating TH Throttled VCT Ported to the Volume Control Tank Page 4 of 95 Rev. 0  


PART 2 ITEM 2
PART 2 ITEM 2 KEY TO TEST REQUIREMENTS
- KEY TO TEST REQUIREMENTS
: 1.
: 1. Category "A" leak rate test per Section XI, Article IWV-3420.
Category "A" leak rate test per Section XI, Article IWV-3420.
: 2. Category "B" exercising test per Section XI, Article IWV-3410, for manual valves.
: 2.
: 3. Category "A" and "B" exercising test per Section XI, Article IWV-3410 and Stroke Time measurement Test per Section XI, Article 3410(c).
Category "B" exercising test per Section XI, Article IWV-3410, for manual valves.
: 4. Category "A" and "B" fail-safe tests per Section XI, Article 3410(e)
: 3.
: 5. Category "C" (Safety/Relief) valve tests per Section XI, Article 3510.
Category "A" and "B" exercising test per Section XI, Article IWV-3410 and Stroke Time measurement Test per Section XI, Article 3410(c).
: 6. Category "C" (Check) valve tests per Section XI, Article 3520.
: 4.
Category "E" (Locked) valve verification per Section XI, Article 3700.
Category "A" and "B" fail-safe tests per Section XI, Article 3410(e)
NOTE: There are no Category "D" valves at Salem 2 that require testing per Section XI.
: 5.
Page 5 of 95                             Rev. 0
Category "C" (Safety/Relief) valve tests per Section XI, Article 3510.
: 6.
Category "C" (Check) valve tests per Section XI, Article 3520.
Category "E" (Locked) valve verification per Section XI, Article 3700.
NOTE:
There are no Category "D" valves at Salem 2 that require testing per Section XI.
Page 5 of 95 Rev. 0  


PART 2 ITEM 3 OPERATIONAL MODES REACTIVITY           % RATED           AVERAGE COOLANT CONDITION, Keff     THERMAL POWER*         TEMPERATURE MODE
MODE
#  l. POWER OPERATION           >0.99               >5%               >350°F
# l.
#  2. STARTUP                  >0.99               <5%               >35.0&deg;F
: 2.
#  3. HOT STANDBY               <0.99               0                 >350&deg;F
: 3.
: 4. HOT SHUTDOWN             <0.99               0                 3S0&deg;F > T
: 4.
#                                                                                    avg > 200&deg;F
: 5.
: 5. COLD SHUTDOWN             <0.99               0                 <200&deg;F
: 6.
: 6. REFUELING **             <0.95               0                 <140&deg;F NOTES:    #  For purpose of the IST, modes 1-4 shall be grouped together and referred to as Power Operation.
NOTES:
* Excluding decay heat.
PART 2 ITEM 3 OPERATIONAL MODES REACTIVITY  
            **  Reactor vessel head unbolted or removed and fuel in the vessel.
% RATED AVERAGE COOLANT CONDITION, Keff THERMAL POWER*
Page 6 of 95                             Rev. 0
TEMPERATURE POWER OPERATION  
>0.99  
>5%  
>350&deg;F STARTUP
>0.99  
<5%  
>35.0&deg;F HOT STANDBY  
<0.99 0  
>350&deg;F HOT SHUTDOWN  
<0.99 0
3S0&deg;F > T  
> 200&deg;F  
<200&deg;F avg COLD SHUTDOWN  
<0.99 0
REFUELING **  
<0.95 0  
<140&deg;F For purpose of the IST, modes 1-4 shall be grouped together and referred to as Power Operation.
Excluding decay heat.
Reactor vessel head unbolted or removed and fuel in the vessel.
Page 6 of 95 Rev. 0  


PART 2 ITEM 4 LIST OF EFFECTIVE PAGES March 11, 1980      Pages 1 - 95     Rev. 0 Page 7 of 95             Rev. 0
March 11, 1980 PART 2 ITEM 4 LIST OF EFFECTIVE PAGES Pages 1 -
95 Page 7 of 95 Rev. 0 Rev. 0  


SYSTEM     AUXILIARY FEED (AF)                           DRAWING NO. 205336
SYSTEM AUXILIARY FEED (AF)
                                                                      ~~~~~~~--~~~~
DRAWING NO.
PAGE  B of 95  Rev. 0
205336 PAGE B of 95 Rev. 0
                                              ~
~~~~~~~--~~~~  
~
(/)
(/)
(/)                 w                                 8 w                   ::r: w                           z 8                   u     p.,
(/)
                          .:i:
w 8
z                   z    ><      i:i::       z       ~
w
VALVE                         VALVE        H     8       0           0                   8                   REMARKS 8                   ~
::r:
                                                                    . ~~
w z
H                  ~
8 u
p.,  
~
.:i:
z i:i::
z VALVE z
VALVE H
8 0
0  
~
8 REMARKS H
~
8  
~~
i:r.. (/)
i:r.. (/)
Nl1MBER         (/)
Nl1MBER
                          ~     CATEGORY           w       .:i:               H     w w         (NOT TO BE USED FOR RELIEF BASIS) w                                 ::>        ::>
(/)  
                                                              ~~
~
(/)                              !>                        8       H j   8u                  N H    ~       u ><      00 Ul OI   ..:l OI u                         (/)   !>      .:i: 8   z p., ~~      ~~
CATEGORY w  
A B c D E 21AF4           3     Dl           x       6     CK       SA       c       6       YES 22AF4           3     D3           x       6     CK       SA       c       6       YES 23AF4           3     D5           x       B     CK       SA       c       6       YES 21AFB           3     E2           x       4,     CK       SA       c       6       YES 22AFB           3     E4           x       4     CK       SA       c       6       YES 23AFB           3     E6           x       6     CK       SA       c       6     -YES 21AF11           3   E6         x         4     PL       A       MOD     3,4     NO 22AF11           3   F6         x         4     PL       A       MOD     3,4     NO 23AF11           3   F6         x         4     PL       A       MOD     3,4     NO 24AF11           3   G6         x         4     PL       A         MOD   3,4     NO 21AF21           3   GS         x         4     GL       A         MOD   3,4     NO 22AF21           3   FS         x         4     GL       A         MOD   3,4     NO 23AF21           3   FS         x         4     GL       A         MOD   3,4     NO 24AF21           3   F3         x         4     GL       A         MOD   3,4     NO 21AF23           3   GB           x   x 4     SCK     SA/M     PER   6,7     YES       (Val. Wheel LO) 22AF23           3   GB           x   x 4     SCK     SA/M     PER   6,7     YES       (Val. Wheel LO)*
.:i:
23AF23           3   FB           x   x 4     SCK     SA/M     PER   6,7     YES.       (Val. Wheel LO) 24AF23           3   FB           x   x 4     SCK     SA/M     PER   6,7     YES       (Val. Wheel LO) 2AF42             3     C6               x 2.5     GA       M         LO       7     NO 2AF99             3   C2           x     0.75   REL     SA       c     5       NO 2AF103           3     D7               x 2     GL       M         LO     7       NO 2AF104           3     D7               x 0.75   GL       M         LO     7       NO
H w w (NOT TO BE USED FOR RELIEF BASIS)
(/)
w  
~~
8 H ::>
j 8
N  
~
Ul OI  
..:l OI H
u ><
00
~~ ~~
u u
(/)  
.:i: 8 z p.,
A B c D
E 21AF4 3
Dl x
6 CK SA c
6 YES 22AF4 3
D3 x
6 CK SA c
6 YES 23AF4 3
D5 x
B CK SA c
6 YES 21AFB 3
E2 x
4, CK SA c
6 YES 22AFB 3
E4 x
4 CK SA c
6 YES 23AFB 3
E6 x
6 CK SA c
6  
-YES 21AF11 3
E6 x
4 PL A
MOD 3,4 NO 22AF11 3
F6 x
4 PL A
MOD 3,4 NO 23AF11 3
F6 x
4 PL A
MOD 3,4 NO 24AF11 3
G6 x
4 PL A
MOD 3,4 NO 21AF21 3
GS x
4 GL A
MOD 3,4 NO 22AF21 3
FS x
4 GL A
MOD 3,4 NO 23AF21 3
FS x
4 GL A
MOD 3,4 NO 24AF21 3
F3 x
4 GL A
MOD 3,4 NO 21AF23 3
GB x
x 4
SCK SA/M PER 6,7 YES (Val. Wheel LO) 22AF23 3
GB x
x 4
SCK SA/M PER 6,7 YES (Val. Wheel LO)*
23AF23 3
FB x
x 4
SCK SA/M PER 6,7 YES.
(Val. Wheel LO) 24AF23 3
FB x
x 4
SCK SA/M PER 6,7 YES (Val. Wheel LO) 2AF42 3
C6 x 2.5 GA M
LO 7
NO 2AF99 3
C2 x
0.75 REL SA c
5 NO 2AF103 3
D7 x
2 GL M
LO 7
NO 2AF104 3
D7 x 0.75 GL M
LO 7
NO  


e                                                   e                                               PAGE  9 of 9S e
e e
Rev. 0 SYSTEM     AUXILIARY FEED (AF)                               DRAWING N0.___.:2~0~S~3~3~6=--~~~~~~~~
e SYSTEM AUXILIARY FEED (AF)
                                              ~
DRAWING N0.___.:2~0~S~3~3~6=--~~~~~~~~ PAGE 9 of 9S Rev. 0
en en                     w                                       8 w                     :r::     w                               z 8                     u       p..
~
                        .:i; zH                      z       >t       ~             z       ~
en en w
VALVE                         VALVE        H       8       0             0                 8               REMARKS
8 w
                                              ........                                  ~    ri.
:r::
                                                                          . ~~
w z
8                              U)
8 u
NttMBER             ~       CATEGORY               w                                   w w     (NOT TO BE USED FOR RELIEF BASIS)
p..  
                                                                  ~ w U)                                                                    H U)                           w       >                            8 ::i H   ::J en
~
                  ~
.:i; z  
8   p..
>t  
                                                        ~
~
N                                        01   H OI u
z VALVE z
8u                      H en u >t
VALVE H
                                                                  .:i; 8 00 z p..   ~~      ~~
8 0
A B c D E 2AF10S         3     D7                 x 0.7S       GL     M           LO     7       NO 2AF106         3     D7                 x 0.7S       GL     M           LO     7       NO 2AF128         3     D7             x     l.S         REL     SA         c       s       NO c                                              -
0  
21AFS2         3     El           x         6         PL     A                   3       NO 22AFS2         3     E3           x         6         PL     A           c       3       NO 23AFS2         3     ES           x         8         PL       A         c       3       NO 21AFS3         3     El             x       6         CK       SA         c       6       YES 22AFS3         3     E3             x       6         CK       SA         c       6       YES 23AF53         3     ES             x       8         CK       SA         c       6       YES 21AF3         3     Dl                 x 6         GA       M         LO     7       NO 22AF3         3     D3                 x 6         GA       M         LO     7       NO 23AF3         3     DS                 x 8         GA       M         LO     7       NO 21AF20         3     GS                 x 4         GA       M         LO     7       NO 22AF20         3   GS                 x 4         GA       M         LO     7       NO 23AF20         3   FS                 x 4         GA       M         LO     7       NO 24AF20         3   F3                 x 4         GA       M         LO     7       NO 21AF22         3   G6                 x 4         GA       M         LO     7       NO 22AF22         3   G6                 x   4         GA       M         LO     7       NO 23AF22         3   F6                 x 4         GA       M         LO     7       NO 24AF22         3   F4                 x 4         GA       M         LO     7       NO 2AF1           3   Bl                 x   10       GA       M         LO     7       NO 21AF10         3     G6                 x   4         GA       M         LO     7       NO
~
8 REMARKS H
8
~~
ri. U)
NttMBER U)
~
CATEGORY w  
~ w H
w w (NOT TO BE USED FOR RELIEF BASIS)
U) w 8
::i H
::J  
~
8 N
~
8 p...
en 01 H OI H
u >t 00
~~ ~~
u u
en
.:i; 8 z p..
A B c D
E 2AF10S 3
D7 x
0.7S GL M
LO 7
NO 2AF106 3
D7 x
0.7S GL M
LO 7
NO 2AF128 3
D7 x
l.S REL SA c
s NO 21AFS2 3
El x
6 PL A
c 3
NO 22AFS2 3
E3 x
6 PL A
c 3
NO 23AFS2 3
ES x
8 PL A
c 3
NO 21AFS3 3
El x
6 CK SA c
6 YES 22AFS3 3
E3 x
6 CK SA c
6 YES 23AF53 3
ES x
8 CK SA c
6 YES 21AF3 3
Dl x
6 GA M
LO 7
NO 22AF3 3
D3 x
6 GA M
LO 7
NO 23AF3 3
DS x
8 GA M
LO 7
NO 21AF20 3
GS x
4 GA M
LO 7
NO 22AF20 3
GS x
4 GA M
LO 7
NO 23AF20 3
FS x
4 GA M
LO 7
NO 24AF20 3
F3 x
4 GA M
LO 7
NO 21AF22 3
G6 x
4 GA M
LO 7
NO 22AF22 3
G6 x
4 GA M
LO 7
NO 23AF22 3
F6 x
4 GA M
LO 7
NO 24AF22 3
F4 x
4 GA M
LO 7
NO 2AF1 3
Bl x
10 GA M
LO 7
NO 21AF10 3
G6 x
4 GA M
LO 7
NO  


DRAWING N0.~~~2~0~5~3~3~6~~~~~~-               PAGE 10 of 95   Rev. 0 U)
DRAWING N0.~~~2~0~5~3~3~6~~~~~~-
Cl.l                   w                                       E-i w
PAGE 10 of 95 Rev. 0 U)
Cl.l w
E-i w
:r:
w z
E-i
E-i
:r:
(.)
(.)
w 0.
: 0.  
z
~
                  -=i:
-=i:
zH                      z         ><      i:x:         z       ~
z i:x:
VALVE                 E-i     0           0                 E-i             REMARKS
z VP.I.NE z
                                                                                  ~
VALVE H
VP.I.NE                                H
E-i 0
                                          .......            E-i                       &#xb5;., Cl.l
0  
                                                                      . z~~
~
Nl'MBER   Cl.l
E-i REMARKS H
                    ~       CATEGORY               w       -=i:                 H   w w     (NOT TO BE USED FOR RELIEF BASIS)
E-i  
Cl.l                         w       :>      :::> w           E-i :::> H :::>
~~
:s
&#xb5;.,
Cl.l Nl'MBER Cl.l  
~
CATEGORY w  
-=i:
H w w (NOT TO BE USED FOR RELIEF BASIS)
Cl.l w
:::> w E-i :::>
H
:s 8
N
~
E-i 0..
Cl.l QI
!-=I QI H
(.) ><
00
~~ ~~
(.)
(.)
8
(.)
(.)
N H
Cl.l  
Cl.l       ~
-=i: E-i z 0.
E-i 0.
A B c D
(.) ><
E 22AF10 3
                                                            -=i: E-i 00 0.
G6 x
Cl.l QI
4 GA M
                                                                              ~~
LO 7
                                                                                        !-=I QI
NO 23AF10 3
                                                                                        ~~
F6 x
A B c D E 22AF10     3     G6                 x 4         GA         M       LO   7         NO 23AF10     3     F6                 x 4         GA         M       LO   7         NO 24AF10     3     F6                 x 4         GA         M       LO   7         NO 21AF86     3     G6                 x 4         GA         M       LO   7         NO 22AF86     3     G6                 x 4         GA         M       LO   7         NO 23AF86     3     F6                 x 4         GA         M       LO   7         NO 23AF86     3     F6                 x 4         GA         M       LO   7         NO
4 GA M
                        ~
LO 7
NO 24AF10 3
F6 x
4 GA M
LO 7
NO 21AF86 3
G6 x
4 GA M
LO 7
NO 22AF86 3
G6 x
4 GA M
LO 7
NO 23AF86 3
F6 x
4 GA M
LO 7
NO 23AF86 3
F6 x
4 GA M
LO 7
NO  
~  


VALVE: 21, 22AF4 CATEGORY: C (Check)
VALVE:
CLASS: 3 FUNCTION: To ensure proper directional flow through 21 and 22 Auxiliary Feed Pumps.
21, 22AF4 CATEGORY:
TEST REQUIREMENTS:   Verify valve operability every three months.
C (Check)
BASIS FOR RELIEF: These valves cannot be full stroke exercised during Power Operation without thermal shocking feed nozzles. The normal feed path to the Stearn Generators (SGs) is the only available full flow path for testing.
CLASS:
ALTERNATE TESTING:   These valves are partial stroked through the recirc path during Power Operation and Cold Shutdown. These valves will be manually full stroke exercised per section XI during Refueling.
3 FUNCTION:
VALVE: 23AF4 CATEGORY: C (Check)
To ensure proper directional flow through 21 and 22 Auxiliary Feed Pumps.
CLASS: 3 FUNCTION: To ensure proper directional flow through #23 Auxiliary Feed Pump.
TEST REQUIREMENTS:
TEST REQUIREMENTS:   Verify valve operability every three months.
Verify valve operability every three months.
BASIS FOR RELIEF: This valve cannot be full stroke exercised during Power Operation without thermal shocking. the feed nozzles. The normal feed path to the SGs is the only available full flow path. The valve cannot be tested in Cold Shutdown or Refueling because steam must be available to drive the turbine to operate the #23 Auxiliary Feed Pump to exercise 23AF4.
BASIS FOR RELIEF:
ALTERNATE TESTING:   This valve is partial stroked through the recirc path during Power Operation. This valve will be manually full stroke exercised per Section XI during Refueling.
These valves cannot be full stroke exercised during Power Operation without thermal shocking feed nozzles.
VALVE: 21AF8 and 22AF8 CATEGORY: C (Check)
The normal feed path to the Stearn Generators (SGs) is the only available full flow path for testing.
CLASS: 3 FUNCTION: Prevent backflow through #21 and #22 Auxiliary Feed Pumps.
ALTERNATE TESTING:
TEST REQUIREMENTS:   Verify valve operability every three months.
These valves are partial stroked through the recirc path during Power Operation and Cold Shutdown.
BASIS FOR RELIEF: These valves cannot be exercised during Power Operation because of thermal shock to feed nozzles on the SGs.
These valves will be manually full stroke exercised per section XI during Refueling.
ALTERNATE TESTING:   These valves will be part stroke tested in Cold Shutdown. These valves will be manually full stroke exercised per Section XI during Refuelins.
VALVE:
VALVE: 23AF8 CATEGORY: C (Check)
23AF4 CATEGORY:
CLASS: 3 FUNCTION: Prevent backflow through #23 Auxiliary Feed Pump.
C (Check)
TEST REQUIREMENTS:   Verify valve operability every three months.
CLASS:
BASIS FOR RELIEF: This valve cannot be tested during Power Operation without thermal shocking the feed nozzles on the SGs. It cannot be flow tested during Cold Shutdown or Refueling because there is no steam available to drive the # 3 Auxiliary Feed Pump Turbine.
3 FUNCTION:
ALTERNATE TESTING:   This valve will be manually full stroke exercised per Section XI during Refueling.
To ensure proper directional flow through #23 Auxiliary Feed Pump.
Page 11 of 95                             Rev. 0
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
This valve cannot be full stroke exercised during Power Operation without thermal shocking. the feed nozzles.
The normal feed path to the SGs is the only available full flow path.
The valve cannot be tested in Cold Shutdown or Refueling because steam must be available to drive the turbine to operate the #23 Auxiliary Feed Pump to exercise 23AF4.
ALTERNATE TESTING:
This valve is partial stroked through the recirc path during Power Operation.
This valve will be manually full stroke exercised per Section XI during Refueling.
VALVE:
21AF8 and 22AF8 CATEGORY:
C (Check)
CLASS:
3 FUNCTION:
Prevent backflow through #21 and #22 Auxiliary Feed Pumps.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation because of thermal shock to feed nozzles on the SGs.
ALTERNATE TESTING:
These valves will be part stroke tested in Cold Shutdown.
These valves will be manually full stroke exercised per Section XI during Refuelins.
VALVE:
23AF8 CATEGORY:
C (Check)
CLASS:
3 FUNCTION:
Prevent backflow through #23 Auxiliary Feed Pump.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
This valve cannot be tested during Power Operation without thermal shocking the feed nozzles on the SGs.
It cannot be flow tested during Cold Shutdown or Refueling because there is no steam available to drive the # 3 Auxiliary Feed Pump Turbine.
ALTERNATE TESTING:
This valve will be manually full stroke exercised per Section XI during Refueling.
Page 11 of 95 Rev. 0  


VALVE: 21 - 24AF23   (4 Valves)
VALVE:
CATEGORY: C/E   (Check)
21 -
CLASS: 3 FUNCTION: To prevent backflow of; Stearn Generator water into the Auxiliary Feed System.
24AF23 (4 Valves)
TEST REQUIREMENTS:   Verify valve operability every three months.
CATEGORY:
BASIS FOR RELIEF:   Sarne conditions as 21 - 22AF8.
C/E (Check)
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
CLASS:
VALVE: 21, 22 and 23AF53 CATEGORY: C (Check)
3 FUNCTION:
CLASS: 3 FUNCTION: To prevent water from the normal suction of the Auxiliary Feed Pumps from bypassing the pump and going into the Dernineralized Water System.
To prevent backflow of; Stearn Generator water into the Auxiliary Feed System.
TEST REQUIREMENTS:   Verify valve operability every three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   The line in which this valve is installed is maintained empty and vented to the atmosphere. We do not fill tnis line except in need as it is routed through a vital relay room and a leak would cause extensive damage and trip the reactor.
Verify valve operability every three months.
* ALTERNATE TESTING:   These valves will be manually stroke exercised per Section XI during Refueling.
BASIS FOR RELIEF:
Page 12 of 95                           Rev. 0
Sarne conditions as 21 -
22AF8.
ALTERNATE TESTING:
These valves will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
21, 22 and 23AF53 CATEGORY:
C (Check)
CLASS:
3 FUNCTION:
To prevent water from the normal suction of the Auxiliary Feed Pumps from bypassing the pump and going into the Dernineralized Water System.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
The line in which this valve is installed is maintained empty and vented to the atmosphere.
We do not fill tnis line except in need as it is routed through a vital relay room and a leak would cause extensive damage and trip the reactor.
ALTERNATE TESTING:
These valves will be manually stroke exercised per Section XI during Refueling.
Page 12 of 95 Rev. 0  


SYSTEM:....__S_T_E_AM
SYSTEM:....__S_T_E_AM G_E_N_E_RA_T_O_R_F_E_E_D_AN_D_C;....O_N_D_E_N_S_A_T_E_,,_(B_F__,).___
__G_E_N_E_RA_T_O_R_F_E_E_D_AN_D_C;....O_N_D_E_N_S_A_T_E_,,_(B_F__,).___     DRAWING       N0._--=2~0~5~3~0~2:._____________~         PAGE   13 of 95   Rev. 0
DRAWING N0._--=2~0~5~3~0~2:.__ ___________ ~ PAGE 13 of 95 Rev. 0  
                                                                              ~
~
Ul Ul w                                           w                                                   8 8
Ul Ul w
8 w
::r:
::r:
u w
w z
p..
z
                                  <t:
z                                            z            :><      0::                z        ~
VALVE                        H VALVE                      H            8        0                  0        gj        8                  REMARKS
                                                                                                                    ~~
                                                                              ~
8                                  ~    Ul NPMB ER            Cl)
                                  ~              CATEGORY                                  w        <t:                          H    ww          (NOT TO BE USED FOR RELIEF BASIS)
Cl)                                                    w            !>      :::> w                    8  :::> H :::>
:s u
8u                                            N H
Ul
                                                                                            ~
8 u
8 u
                                                                                                    <t: 8 Pl
p..
:><    '  00 z  p..
~
Cl)
<t:
                                                                                                                              ~
z 0::
QI   ,_::i QI gj gj ~
z VALVE z
A   B       c   D     E 21BF22             2       E7                         x         x     14           SCK       SA/M           PER     6,7       YES     (Hand Wheel LO) 22BF22             2       E9                         x         x     14           SCK       SA/M           PER     6,7       YES     (Hand Wheel LO) 2~BF22             2       EB                         x         x     14           SCK       SA/M           PER     6,7       YES     (Hand Wheel LO) 24BF22             2       EB                         x         x     14           SCK       SA/M           PER     6,7       YES     (Hand Wheel LO)
VALVE H
8 0
0 gj 8
REMARKS H
~
8
~~
~ Ul NP MB ER Cl)
~
CATEGORY w
<t:
H w w (NOT TO BE USED FOR RELIEF BASIS)
Cl) w
:::> w 8
H
:s 8
N
~
8 Pl Cl) QI  
,_::i QI H
u :><
00
~ gj gj ~
u u
Ul
<t: 8 z p..
A B
c D E 21BF22 2
E7 x
x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO) 22BF22 2
E9 x
x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO) 2~BF22 2
EB x
x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO) 24BF22 2
EB x
x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO)  


VALVE: 21 - 24BF22   (4 Valves)
VALVE:
CATEGORY: C/E (Check)
21 -
CLASS: 2 FUNCTION: To prevent backflow of SG water when Main Feed is secured.
24BF22 (4 Valves)
TEST REQUIREMENTS:   Verify valve operability every three months.
CATEGORY:
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation because 3 loop operation is not permitted. A Plant trip would be required to exercise these valves to their safety-related position.
C/E (Check)
ALTERNATE TESTING:   Valve function will be verified during Cold Shutdown and Refueling per Section XI.
CLASS:
Page 14 of 95                             Rev. 0
2 FUNCTION:
To prevent backflow of SG water when Main Feed is secured.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation because 3 loop operation is not permitted.
A Plant trip would be required to exercise these valves to their safety-related position.
ALTERNATE TESTING:
Valve function will be verified during Cold Shutdown and Refueling per Section XI.
Page 14 of 95 Rev. 0  


SYSTEM~~-C_H_EM~IC_A_L~A_N_D~V_O_L_U_ME~_C_O_N_T_R_O_L__..(_cv_c_s_-_O_P_S_)'--~~     DRAWING NO.       20S328                         PAGE lS of 9S     Rev. 0 U)
SYSTEM~~-C_H_EM~IC_A_L~A_N_D~V_O_L_U_ME~_C_O_N_T_R_O_L__..(_cv_c_s_-_O_P_S_)'--~~ DRAWING NO.
U)                                     &#xb5;:i                                     8
20S328 PAGE lS of 9S Rev. 0 U)
                                  &#xb5;:i 8
U)  
::r:
&#xb5;:i 8  
u
&#xb5;:i
                                                                                  &#xb5;:i A.
::r:  
z
&#xb5;:i z
                                  .:i:
z                                      z      ><      n::          z       ~
VALVE                                        VALVE                  H      8        0            0                8                    REMARKS
                                                                        ......            8                      ~  r..
                                                                                                      ~~
H                                                                                      U)
Nl'MBER              en                      CATEGORY                                                                        (NOT TO BE USED FOR RELIEF BASIS)
                                  ~                                                        .:i:                          <i:l
                                                                                  &#xb5;:i                            H  &#xb5;:i en                                                      :>
                                                                                          ~~
                                                                        &#xb5;:i                                  8  ::i H  ::i
:s u
8 u
8 u
H N
A.
U)       ~       u ><
~
                                                                                          .:i: 8 z0 0 A.
.:i:
UJ OI
z n::
                                                                                                              ~~
z VALVE z
H OI
VALVE H
                                                                                                                      ~~
8 0
A   B   c   D   E 2CV3               2         C8           x                       2         PL       A         0       1,3     YES     <10 Sec. Ph. "A" Cont. Isol.
0
4 2CV4               2         C8           x                       2         PL       A         0       1,3     YES     <10 Sec. Ph. "A" cont. Isol.
~
4 2CVS               2         C8           x                       2         PL       A         0       143     YES     <10 Sec. Ph. "A" Cont. Isol.
8 REMARKS H
2CV6               2         C9                     x             2         REL     SA       c           s     NO 2CV7               2         C6           x                       2         PL       A         0       1,3     YES     <10 Sec. Ph. "A" Cont. Isol.
8
4 2CV40               2         C4               x                 4         GA       MO       0           3     YES 2CV41               2         C4               x                 4         GA       MO       0           3     YES 2CV42               2         C4                     x             4         CK       SA       0           6     YES 2CV43               2         B4                     x           0.7S       REL     SA       c           s     NO 2CV47               2         AS                     x             4         CK       SA       c           6     YES 2CVS2               2         AS                     x             4         CK       SA       c           6     YES 2CVSS               2         A6               x                 3         PL       A         TH         3     NO 2CV63               2         A6                     x             3         CK       SA       0           6     NO 2CV68             .l.       B8           x                     3         GA       MO       0       1,3     YES
~~
                                                                                                                                <10 Sec. Ph. "A" Cont. Isol.
r..
2CV69               1         B8           x                     3         GA       MO       0       1,3     YES
U)
                                                                                                                                <10 Sec. Ph. "A" Cont. Isol.
Nl'MBER en
2CV74               1         B8           x       x             3         CK       SA       c           6     YES 2CV9S               3         BS                             x 3           GL       M         LC         7     NO 21CV98             2         E6           x                 x 1           NE       M         L.TH. 1,2     YES 7
~
CATEGORY
&#xb5;:i
.:i:
H
&#xb5;:i <i:l (NOT TO BE USED FOR RELIEF BASIS) en
&#xb5;:i
~~
8
::i H
::i
:s 8
N
~
UJ OI H OI H
u ><
00
~~ ~~
u u
U)
.:i: 8 z A.
A B
c D E 2CV3 2
C8 x
2 PL A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2CV4 2
C8 x
2 PL A
0 1,3 YES  
<10 Sec. Ph. "A" cont. Isol.
4 2CVS 2
C8 x
2 PL A
0 143 YES  
<10 Sec. Ph. "A" Cont. Isol.
2CV6 2
C9 x
2 REL SA c
s NO 2CV7 2
C6 x
2 PL A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2CV40 2
C4 x
4 GA MO 0
3 YES 2CV41 2
C4 x
4 GA MO 0
3 YES 2CV42 2
C4 x
4 CK SA 0
6 YES 2CV43 2
B4 x
0.7S REL SA c
s NO 2CV47 2
AS x
4 CK SA c
6 YES 2CVS2 2
AS x
4 CK SA c
6 YES 2CVSS 2
A6 x
3 PL A
TH 3
NO 2CV63 2
A6 x
3 CK SA 0
6 NO 2CV68  
.l.
B8 x
3 GA MO 0
1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
2CV69 1
B8 x
3 GA MO 0
1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
2CV74 1
B8 x
x 3
CK SA c
6 YES 2CV9S 3
BS x
3 GL M
LC 7
NO 21CV98 2
E6 x
x 1 NE M
L.TH.
1,2 YES 7  


SYSTEM         CHEMICAL AND VOLUME CONTROL (CVCS-OPS)
SYSTEM CHEMICAL AND VOLUME CONTROL (CVCS-OPS)  
      ~~-"""~=.;;.::.=--=;.=.._;,.,c~;;.;;..;;;;;;;........;:~'-'=.=.;;;;""-'~~__.;;.~-'--~~
~~-"""~=.;;.::.=--=;.=.._;,.,c~;;.;;..;;;;;;;........;:~'-'=.=.;;;;""-'~~__.;;.~-'--~~
DRAWING NO. ~~~...::...:::-=-=..:::..:::~~~~~~
DRAWING NO.
205328                      PAGE 16 of 95   Rev. 0
205328
                                                                                  ~
~~~...::...:::-=-=..:::..:::~~~~~~ PAGE 16 of 95 Rev. 0  
~
U)
U)
CJ)                                         w                                         E-<
CJ) w E-<
w                                           :i::     w                               z E-<                                          u        P<
w
                                      .:i; zH                                            z        ><        P::          z       ~
:i::
VALVE                                                VALVE                    H          E-<      0            0                E-<                  REMARKS
w z
                                                                                  ......                                    ~  r:r.. CJ)
                                                                                                                . ~~
E-<
E-<
NUMBER                CJ)
u P<
                                      ~                 CATEGORY                              w        .:i;                 H  WW            (NOT TO BE USED FOR RELIEF BASIS) w
~  
                                                                                                        ~~
.:i; z
CJ)                                                                !>                          E-t ::i H     ::J
P::
:su        8u                                            N H
z VALVE z
CJ)
VALVE H
                                                                                              ~
E-<
u.:i; ><
0 0
~
E-<
E-<
00 z P<
REMARKS H
E-<  
~~
r:r..
CJ)
CJ)
                                                                                                                          ~~
NUMBER CJ)
()I ,_:i
~
                                                                                                                                  ~~
CATEGORY w
OI A     B   c     D     E 22CV98             2           E6               x                   x     1         NE       M           L.TH. 1,2     YES 7
.:i; H
23CV99             2           D6               x                   x     1         NE       M           L.TH. 1,2     YES 7
WW (NOT TO BE USED FOR RELIEF BASIS)
24CV98             2           C6               x                   x     1         NE       M           L.TH. 1,2     YES 7
CJ) w
21CV99             2           D7                         x                 2         CK       SA         0       6       YES 22CV99             2           D7                         x                 2         CK       SA         0       6       YES 23CV99               2           D7                         x                 2         CK         SA         0       6       YES 24CV99             2           D7                         x                 2         CK         SA         0       6       YES 2CV116               2           D6               x                           4         GA       MO         0       1       YES       <10 Sec. Ph. "A" Cont. Isol.
~~
2CV131               2           CB                     x                     1         PL       A           c       3,4     NO 2CV132               2           C7                     x                     1         PL       A           c       3,4     NO 2CV134               2           C7                     x                     1         3 WAY       A         VCT     3       NO 2CV135               2           A4                         x                 2         CK         SA         c       6       NO 2CV137               2           A4                         x                 2         CK         SA       c       6       NO 2CV139               2           C4                     x                     2         GL         MO         0       3       NO 2CV140               2           C4                     x                     2         GL         MO         0       3       NO 2CV141               2           A6                         x               0.75       REL         SA       c       5       NO 2CV147               2           Fl                         x                 2         CK         SA       c       6       NO 21CV151             2           Dl                                     x       2         DIA       M         LC     7       NO 22CV151             2           Dl                                     x       2         DIA       M         LC     7       NO 21CV154             2           El                         x                 2         CK         SA       c       6       NO
E-t ::i H ::J
:s 8
N
~
CJ) ()I  
,_:i OI H
u ><
00
~~ ~~
u u
CJ)
.:i; E-<
z P<
A B c D
E 22CV98 2
E6 x
x 1
NE M
L.TH.
1,2 YES 7
23CV99 2
D6 x
x 1
NE M
L.TH.
1,2 YES 7
24CV98 2
C6 x
x 1
NE M
L.TH.
1,2 YES 7
21CV99 2
D7 x
2 CK SA 0
6 YES 22CV99 2
D7 x
2 CK SA 0
6 YES 23CV99 2
D7 x
2 CK SA 0
6 YES 24CV99 2
D7 x
2 CK SA 0
6 YES 2CV116 2
D6 x
4 GA MO 0
1 YES  
<10 Sec. Ph. "A" Cont. Isol.
2CV131 2
CB x
1 PL A
c 3,4 NO 2CV132 2
C7 x
1 PL A
c 3,4 NO 2CV134 2
C7 x
1 3 WAY A
VCT 3
NO 2CV135 2
A4 x
2 CK SA c
6 NO 2CV137 2
A4 x
2 CK SA c
6 NO 2CV139 2
C4 x
2 GL MO 0
3 NO 2CV140 2
C4 x
2 GL MO 0
3 NO 2CV141 2
A6 x
0.75 REL SA c
5 NO 2CV147 2
Fl x
2 CK SA c
6 NO 21CV151 2
Dl x
2 DIA M
LC 7
NO 22CV151 2
Dl x
2 DIA M
LC 7
NO 21CV154 2
El x
2 CK SA c
6 NO  


e                                                       e                                                                   e SYSTEM   CHEMICAL AND VOLUME CONTROL (CVC-OPS)                 DRAWING NO ..     205328                           PAGE J7 of 95   ReY* 0 U)
e e
U)                       r:Ll                                     8 8
e SYSTEM CHEMICAL AND VOLUME CONTROL (CVC-OPS)
r:Ll                     :r:
DRAWING NO..
u        r:Ll 11<
205328 PAGE J7 of 95 ReY* 0 U)
z i<I; zH                        z        ::...      P::          z       ~
U) r:Ll 8
VALVE                            VALVE        H        8          0            0                8                      REMARKS
r:Ll
                                                                                            ~  rr..
:r:
                                                                                  ~~
r:Ll z
                                                ~
8                              U)
NVMEER        U)
[ii        CATEGORY                r:Ll      i<I;                  H  r:Ll r:Ll    (NOT TO BE USED FOR RELIEF BASIS)
U)                              r:Ll    >          ~~                E-l ::i H ::J
                  ~
                                                          ~
N                                          QI  ,_:i QI u
8 u
8 u
H U) u ::...
11<
i<I; 8
~
                                                                              '  00 z 11<
i<I; z
P::
z VALVE z
VALVE H
8 0
0
~
8 REMARKS H
~
8  
~~
rr..
U)
U)
                                                                                        ~~     ~~
NV MEER U)
A   B c D E 22CV154       2     El             x       2         CK         SA       c       6       NO.
[ii CATEGORY r:Ll i<I; H
21CV156       2     El           x         2         DIA         M         c       2       NO 22CV156       2     El           x         2         DIA         M         c       2       NO 21CV160       2     Fl           x         2         PL         A         c       3       NO 22CV160       2     Fl           x         2         PL         A.       c       3       NO 2CV172       2     E2           x         2         PL         A         AUTO   3       NO 2CV173       2     D2             x       2         CK           SA       c       6       NO 2CV175       2     E3           x         2         GL         MO       c       3       NO 2CV176       2     E3             x       2         CK           SA       c       6       YES 2CV179       2     F3           x         2         PL         A         AUTO   3       NO 2CV180       2     F3             x       2         CK           SA       c       6       NO 2CV181       2     G3           x         2         DIA         A         AUTO   3,4     NO 2CV185       2     D3           x         2         DIA         A         AUTO   3,4     NO 2CV196       2     D4             x       1         CK           SA       0       6       YES 2CV241       2     G4             x       3         REL         SA       c       5       NO 2CV278       2     C8           x         1         PL           A       c       3,4     NO 2CV284       2     D6       x             4         GA           MO       0       1       YES       <10 Sec. Ph. "A" Cont. Isol.
r:Ll r:Ll (NOT TO BE USED FOR RELIEF BASIS)
2CV44         2     B4                   x   6         GA           M       LO     7       NO 2CV49         2     A4                   x   6         GA           M       LO     7       NO 2CV48         1     B6                   x   4         GA           M       LO     7       NO 2CV53         1     A6                   x   4         GA           M       LO     7       NO                 --
U) r:Ll
2CV54         1     A6                   x   3         GL           M       LO     7       NO
~~
E-l ::i H
::J
~
8 N
~
U) QI
,_:i QI H
u ::...
00
~~ ~~
u u
U) i<I; 8 z 11<
A B c D
E 22CV154 2
El x
2 CK SA c
6 NO.
21CV156 2
El x
2 DIA M
c 2
NO 22CV156 2
El x
2 DIA M
c 2
NO 21CV160 2
Fl x
2 PL A
c 3
NO 22CV160 2
Fl x
2 PL A.
c 3
NO 2CV172 2
E2 x
2 PL A
AUTO 3
NO 2CV173 2
D2 x
2 CK SA c
6 NO 2CV175 2
E3 x
2 GL MO c
3 NO 2CV176 2
E3 x
2 CK SA c
6 YES 2CV179 2
F3 x
2 PL A
AUTO 3
NO 2CV180 2
F3 x
2 CK SA c
6 NO 2CV181 2
G3 x
2 DIA A
AUTO 3,4 NO 2CV185 2
D3 x
2 DIA A
AUTO 3,4 NO 2CV196 2
D4 x
1 CK SA 0
6 YES 2CV241 2
G4 x
3 REL SA c
5 NO 2CV278 2
C8 x
1 PL A
c 3,4 NO 2CV284 2
D6 x
4 GA MO 0
1 YES  
<10 Sec. Ph. "A" Cont. Isol.
2CV44 2
B4 x
6 GA M
LO 7
NO 2CV49 2
A4 x
6 GA M
LO 7
NO 2CV48 1
B6 x
4 GA M
LO 7
NO 2CV53 1
A6 x
4 GA M
LO 7
NO 2CV54 1
A6 x
3 GL M
LO 7
NO  


SYSTEM~~~C=H=E=M=I~C=AL=-~AN~D_V~O=L=U=ME-=-~C~O=N=T=R~O=L..__~~~~~~~     DRAWING N0.~~2~0=5=3=2=8'--~~~~~~~             PAGE 18 of 95   Rev. O Ul Ul                                 w                                     8 8
SYSTEM~~~C=H=E=M=I~C=AL=-~AN~D_V~O=L=U=ME-=-~C~O=N=T=R~O=L..__~~~~~~~ DRAWING N0.~~2~0=5=3=2=8'--~~~~~~~ PAGE 18 of 95 Rev. O Ul Ul w
w                                :r:
8 w
u r:a P<
:r:
z
r:a z
                            ,:i:
zH                                zH      >i      ii:::          z     ~
VALVE                                  VALVE            ...-    8        0              0      gJ r... 8                REMARKS 8
                                                                                            ~~
Ul Nl'MBER          Ul
                            &sect;            CATEGORY                    w        ,:i:                  H    w r:a  (NOT TO BE USED FOR RELIEF BASIS) w      :>-                                  H ::::>
                                                                                ~~
Ul                                                                          8  ::::>
j
                                                                      ~
N u
8 u
8 u
H Ul u
P<
                                                                                ,:i: 8
~
                                                                                      >i I
,:i:
00 z P<
z
Ul OI g:1 gJ
>i ii:::
                                                                                                            ..:IOI
z VALVE z
                                                                                                            ~~
VALVE H
A   B   c   D   E 2CV56           1       A6                         x     3       GL       M         LO     7         NO 2CV296           2       ca           x     x           0.-75     CK       SA         0     1,6       YES
8 0
0 gJ 8
REMARKS H
8
~~
r... Ul Nl'MBER Ul
&sect; CATEGORY w
,:i:
H w r:a (NOT TO BE USED FOR RELIEF BASIS)
Ul w
~~
8 H
j 8
N
~
I Ul OI  
..:IOI H
u >i 00 g:1 gJ
~~
u u
Ul
,:i: 8 z P<
A B c D
E 2CV56 1
A6 x
3 GL M
LO 7
NO 2CV296 2
ca x
x 0.-75 CK SA 0
1,6 YES  


VALVE: 2CV3, 2CV4, 2CV5 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Reactor Coolant Letdown.
VALVE:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
2CV3, 2CV4, 2CV5 CATEGORY:
                                )
A CLASS:
BASIS FOR RELIEF: Because the* safety-related function of these valves is containment isolation they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI, for category A valves used for containment isolation.
2 FUNCTION:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
Containment Isolation for Reactor Coolant Letdown.
VALVE: 2CV7 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Reactor Coolant Letdown Line.
TEST REQUIREMENTS:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
Leak Rate Testing less than each 24 months.  
BASIS FOR RELIEF: a)   This valve cannot be exercised during Power Operation because this would isolate normal letdown flow through the Regenerative Heat Exchanger causing the injection of cold water into the RCS resulting in thermal cycling of injection nozzles and possible cracking damage.
)
b)   Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI, for category A valves used for containment isolation.
BASIS FOR RELIEF:
ALTERNATE TESTING:  a)  Testing will be performed during Cold Shutdown and Refueling per Section XI.
Because the* safety-related function of these valves is containment isolation they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
b)  Leak Rate Test per Technical Specification 4.6.1.2.d.
This test meets the intent of the ASME B&PV Code, Section XI, for category A valves used for containment isolation.
VALVE:  2CV40 and 2CV41 CATEGORY:  B CLASS:  2 FUNCTION: Volume Control Tank Outlet isolation valves.
ALTERNATE TESTING:
TEST REQUIREMENTS: Stroke Time Testing each three months.
Leak Rate Test per Technical Specification 4.6.1.2.d.
BASIS FOR RELIEF: Closing these valves during Power Operation requires lining up the alternate source of water from the Refueling Water Storage Tank to the suction of the Charging Pumps. This is 2,000 ppm borated water which would render the reactor subcritical.
VALVE:
ALTERNATE TESTING: Testing will be performed during Cold Shutdown and Refueling per section XI.
2CV7 CATEGORY:
Page 19 of 95                             Rev. 0
A CLASS:
2 FUNCTION:
Containment Isolation for Reactor Coolant Letdown Line.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
BASIS FOR RELIEF:
a)
This valve cannot be exercised during Power Operation because this would isolate normal letdown flow through the Regenerative Heat Exchanger causing the injection of cold water into the RCS resulting in thermal cycling of injection nozzles and possible cracking damage.
b)
Because the safety-related function of this valve is containment ALTERNATE TESTING:
a) b)
VALVE:
2CV40 and 2CV41 CATEGORY:
B CLASS:
2 isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI, for category A valves used for containment isolation.
Testing will be performed during Cold Shutdown and Refueling per Section XI.
Leak Rate Test per Technical Specification 4.6.1.2.d.
FUNCTION:
Volume Control Tank Outlet isolation valves.
TEST REQUIREMENTS:
Stroke Time Testing each three months.
BASIS FOR RELIEF:
Closing these valves during Power Operation requires lining up the alternate source of water from the Refueling Water Storage Tank to the suction of the Charging Pumps.
This is 2,000 ppm borated water which would render the reactor subcritical.
ALTERNATE TESTING:
Testing will be performed during Cold Shutdown and Refueling per section XI.
Page 19 of 95 Rev. 0  


VALVE: 2CV42 CATEGORY: c (Check)
VALVE:
CLASS: 2 FUNCTION:' To prevent backf low into the Volume Control Tank from the suction of the Charging Pumps.
2CV42 CATEGORY:
TEST REQUIREMENTS:   Verify valve operability every three months.
c (Check)
BASIS FOR RELIEF:   This valve cannot be exercised during Power Operation. Exercising (closing) would result in a loss of normal make-up to the RCS, Pressurizer Level Control. and RCP Seal Flow. This would require a reactor trip. Use of the only alternate suction for the Charging Pumps, the RWST, which is water borated to % 2000 ppm, would result in a Reactor Shutdown.
CLASS:
ALTERNATE TESTING:   This valve will be tested during Cold Shutdown and Refueling per Section XI.
2 FUNCTION:'
VALVE: 2CV68 and 2CV69 CATEGORY: A CLASS: 1 FUNCTION: Containment Isolation from Charging Pumps to Regenative Heat Exchanger.
To prevent backf low into the Volume Control Tank from the suction of the Charging Pumps.
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months; stroke Time Testing each three months; Fail Safe Testing each three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   a)   Thse valves cannot be exercised during Power Operation. If these valves failed shut during testing loss of Pressurizer Level Control would result requir.ing a Reactor Trip.
Verify valve operability every three months.
b)   Beacuse the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
BASIS FOR RELIEF:
~ ALTERNATE TESTING:   a) These valves will be tested during Cold Shutdown and Refueling per Section XI.
This valve cannot be exercised during Power Operation.
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
Exercising (closing) would result in a loss of normal make-up to the RCS, Pressurizer Level Control. and RCP Seal Flow.
VALVE: 2CV74 CATEGORY: A/C (Check)
This would require a reactor trip.
CLASS: 1 FUNCTION: To ensure proper direction flow through the Regenerative Heat Exchanger.
Use of the only alternate suction for the Charging Pumps, the RWST, which is water borated to % 2000 ppm, would result in a Reactor Shutdown.
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months; verify valve operability every three months.
ALTERNATE TESTING:
This valve will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
2CV68 and 2CV69 CATEGORY:
A CLASS:
1 FUNCTION:
Containment Isolation from Charging Pumps to Regenative Heat Exchanger.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months; stroke Time Testing each three months; Fail Safe Testing each three months.
BASIS FOR RELIEF:
a)
Thse valves cannot be exercised during Power Operation.
If these valves failed shut during testing loss of Pressurizer Level Control would result requir.ing a Reactor Trip.
b)
Beacuse the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.  
~
ALTERNATE TESTING:
a)
These valves will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2CV74 CATEGORY:
A/C (Check)
CLASS:
1 FUNCTION:
To ensure proper direction flow through the Regenerative Heat Exchanger.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months; verify valve operability every three months.
(
(
BASIS FOR RELIEF:   a)   Shutting this valve during Power Operation would cause a loss of Pressurizing Level Control and a Reactor Trip would result.
BASIS FOR RELIEF:
b)   Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI; for category A valves used for containment isolation.
a)
ALTERNATE TESTING:   a) This valve will be tested during Cold Shutdown and Refueling per Section XI.
Shutting this valve during Power Operation would cause a loss of Pressurizing Level Control and a Reactor Trip would result.
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
b)
Page 20 of 95                             Rev. 0
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI; for category A valves used for containment isolation.
ALTERNATE TESTING:
a)
This valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 20 of 95 Rev. 0  


VALVE: 21 - 24CV99   (4 Valves)
VALVE:
CATEGORY: C (Check)
21 -
CLASS: 2
24CV99 (4 Valves)
~ FUNCTION: To ensure proper flow direction through Reactor Coolant Pump Seals.
CATEGORY:
TEST REQUIREMENTS:   Verify valve operability every three months.
C (Check)
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation without securing seal water to a RCP resulting in a loss of a RCP requiring a Reactor Trip.
CLASS:
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
2  
VALVE: 2CV116 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Reactor Coolant Pump seal water return line.
~
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
FUNCTION:
BASIS FOR RELIEF:   a)   These valves cannot be exercised during Power Operation. Shutting these valves would cause a RCP trip which would then cause a Reactor Trip.
To ensure proper flow direction through Reactor Coolant Pump Seals.
b)   Beacuse the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J .. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
TEST REQUIREMENTS:
ALTERNATE TESTING:   a)   This valve will be tested during Cold Shutdown and Refueling per Section XI.
Verify valve operability every three months.
b)   Leak Rate Test per Technical Specification 4.6.1.2.d.
BASIS FOR RELIEF:
VALVE: 2CV176 CATEGORY: C (Check)
These valves cannot be exercised during Power Operation without securing seal water to a RCP resulting in a loss of a RCP requiring a Reactor Trip.
CLASS: 2 FUNCTION: To ensure proper flow direction in the Rapid Boration Line.
ALTERNATE TESTING:
TEST REQUIREMENTS:   Verify valve operability every three months.
These valves will be tested during Cold Shutdown and Refueling per Section XI.
BASIS FOR RELIEF:   Testing during Power Operation would cause a loss in Reactor Power due to high boron injection.
VALVE:
ALTERNATE TESTING:   This valve will be tested during Cold Shutdown and Refueling per Section XI.
2CV116 CATEGORY:
VALVE: 2CV196 CATEGORY: C (Check)
A CLASS:
CLASS: 2 FUNCTION: To prevent backflow of water from the Charging Pump suction into the Chemical Addition Tank.
2 FUNCTION:
TEST REQUIREMENTS:   Verify valve operability every three months.
Containment Isolation for Reactor Coolant Pump seal water return line.
BASIS FOR RELIEF:   This valve is a category c passive valve not required to change position to perform its safety-related function.
TEST REQUIREMENTS:
ALTERNATE TESTING:   None.
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
Page 21 of 95                             Rev. 0
BASIS FOR RELIEF:
a)
These valves cannot be exercised during Power Operation.
Shutting these valves would cause a RCP trip which would then cause a Reactor Trip.
b)
Beacuse the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
a)
This valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2CV176 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To ensure proper flow direction in the Rapid Boration Line.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Testing during Power Operation would cause a loss in Reactor Power due to high boron injection.
ALTERNATE TESTING:
This valve will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
2CV196 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To prevent backflow of water from the Charging Pump suction into the Chemical Addition Tank.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
This valve is a category c passive valve not required to change position to perform its safety-related function.
ALTERNATE TESTING:
None.
Page 21 of 95 Rev. 0  


VALVE: 2CV284 CATEGORY: A CLASS: 2
VALVE:
~ FUNC~ION: Containment Isolation from Reactor Coolant Pump Seal Water Return Line.
2CV284 CATEGORY:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
A CLASS:
BASIS FOR RELIEF: a)   Seal return line cannot be isolated during Power Operation without tripping a RCP which will cause a Reator Trip.
2  
b)   Beacuse the safety-related function of this valve is containment isolation, it will be tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code,.Section XI for category A valves used for containment isolation.
~
ALTERNATE TESTING:   a) This valve will be tested during Cold Shutdown and Refueling per Section XI.
FUNC~ION: Containment Isolation from Reactor Coolant Pump Seal Water Return Line.
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
TEST REQUIREMENTS:
VALVE: 2CV47, 2CV52 CATEGORY: C (Check)
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
CLASS: 2 FUNCTION: To prevent backflow through the #21 and #22 Charging/Safety Injection (HPSI) Pumps.
BASIS FOR RELIEF:
TEST REQUIREMENTS:   Verify valve operability every three months.
a)
BASIS FOR RELIEF:  Valve cannot be full stroke exercised during Power Operation due to limited size of Letdown Line.
Seal return line cannot be isolated during Power Operation without tripping a RCP which will cause a Reator Trip.
ALTERNATE TESTING:  This valve will be part stroke tested quarterly per Section XI.
b)
Beacuse the safety-related function of this valve is containment isolation, it will be tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code,.Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
a)
This valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2CV47, 2CV52 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To prevent backflow through the #21 and #22 Charging/Safety Injection (HPSI) Pumps.
TEST REQUIREMENTS:
BASIS FOR RELIEF:
ALTERNATE TESTING:
VALVE:
2CV296 Verify valve operability every three months.
Valve cannot be full stroke exercised during Power Operation due to limited size of Letdown Line.
This valve will be part stroke tested quarterly per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
VALVE:  2CV296 CATEGORY: A/C (Check)
CATEGORY:
CLASS: 2 FUNCTION: Overpressure protection for Containment Isolation Piping.
A/C (Check)
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months; Verify valve operability every three months.
CLASS:
BASIS FOR RELIEF: a)   This valve cannot be shut without shutting 2CV284. See relief request for 2CV284.
2 FUNCTION:
b)   Beacuse the safety-related function of this valve is containment isolation, it will be tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
Overpressure protection for Containment Isolation Piping.
ALTERNATE TESTING:   a) This valve will be tested during Cold Shutdown and Refueling per Section XI.
TEST REQUIREMENTS:
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
Leak Rate Testing less than each 24 months; Verify valve operability every three months.
Page 22 of 95                             Rev. 0
BASIS FOR RELIEF:
a)
This valve cannot be shut without shutting 2CV284.
See relief request for 2CV284.
b)
Beacuse the safety-related function of this valve is containment isolation, it will be tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
a)
This valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 22 of 95 Rev. 0  


VALVE: 21 - 24CV98     (4 Valves)
VALVE:
CATEGORY: A/E CLASS: 2 FUNCTION: Throttle Valve for RCP seal flow.
21 -
TEST REQUIREMENTS:   a)   Valve exercising each three months.
24CV98 (4 Valves)
b)   Leak Rate Testing less than each 24 months.
CATEGORY:
BASIS FOR RELIEF:   a)   Valves cannot be shut during Power Operation without causing a loss of seal flow to a RCP. This would cause a RCP trip which would cause a R~actor Trip.
A/E CLASS:
b)   Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.
2 FUNCTION:
ALTERNATE TESTING:   a)   Valve will be tested during Cold Shutdown and Refueling per Section XI.
Throttle Valve for RCP seal flow.
b)   None.
TEST REQUIREMENTS:
Page 23 of 95                             Rev. 0
a)
Valve exercising each three months.
b)
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
a)
Valves cannot be shut during Power Operation without causing a loss of seal flow to a RCP.
This would cause a RCP trip which would cause a R~actor Trip.
b)
Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.
ALTERNATE TESTING:
a)
Valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
None.
Page 23 of 95 Rev. 0  


SYSTEM~~-C_H_I_L_LE_D~W_A_T_E_R~(_C_H_)~~~~~~~~~~~~                           205316                 PAGE 24 of 95   Rev. 0
SYSTEM~~-C_H_I_L_LE_D~W_A_T_E_R~(_C_H_)~~~~~~~~~~~~
                                              ~
205316 PAGE 24 of 95 Rev. 0  
~
U)
U)
U)                     w                                 E-1 w
U) w E-1 w
E-1
::r:
::r:
u w                          z
w z
                                                                                  ~
E-1 u
0.
: 0.
~
ici::
z  
!>I
~
z VALVE z
VALVE H
E-1 0
0
~
E-1 REMARKS H
~
E-1
~~
r:r..
U)
NUMBER l'J)
CATEGORY w
ici::
ici::
zH                      z      !>I ~                z VALVE                        VALVE                E-1  0              0                                REMARKS
H WW (NOT TO BE USED FOR RELIEF BASIS)
                                                                                  ~
U) w
H                                            E-1 E-1                        r:r.. U)
::i w E-1 ::i H
                                                                        ~~
::J
                                              ~
:'.&sect; 8
NUMBER      l'J)
N  
                      @      CATEGORY              w    ici::                  H   WW       (NOT TO BE USED FOR RELIEF BASIS)
~
U)                             w     >  ::i w               E-1 ::i H ::J
E-1 0.
                                                      ~
Ul OI  
:'.&sect;                           N           E-1 0.             Ul OI u
...:IOI H
8u                      H U) u     !>I ici:: E-1
u !>I 00
                                                                    '  00 z 0. ~~
~~ ~~
                                                                                      ...:IOI
u u
                                                                                      ~~
U) ici::
A B   c D E 21CH13       3     D2           x         4       CK   SA           c     6       NO 22CH13       3     D3           x         4       CK   SA           c     6       NO 2CH30       3     F4         x           3       GL   A           0     3,4     NO 2CH74       3     C3         x           3     3 WAY A           COOL   3,4     NO 2CH143       3     Dl           x       0.75     REL SA           c     5       NO 2CH151       3     F4         x           3       GL   A           0     3,4     NO 2CH168       3     Bl         x         1.5     PL   A           c     3,4     NO
E-1 z 0.
A B c D
E 21CH13 3
D2 x
4 CK SA c
6 NO 22CH13 3
D3 x
4 CK SA c
6 NO 2CH30 3
F4 x
3 GL A
0 3,4 NO 2CH74 3
C3 x
3 3 WAY A
COOL 3,4 NO 2CH143 3
Dl x
0.75 REL SA c
5 NO 2CH151 3
F4 x
3 GL A
0 3,4 NO 2CH168 3
Bl x
1.5 PL A
c 3,4 NO  


SYSTEM~__c_o_M_P_O_N_E_N_T_C_O_O_L_I_N_G__(~c_c~>--------------------~     DRAWING NO. ------=;...;;....;;;-=....=:..;;;;;_
SYSTEM~ __
205331 __________                      ~
c_o_M_P_O_N_E_N_T_C_O_O_L_I_N_G __ (~c_c~>--------------------~ DRAWING NO.
PAGE   25 of 95   Rev. 0
205331
                                                                ~
------=;...;;....;;;-=....=:..;;;;;_ __________
~ PAGE 25 of 95 Rev. 0  
~
(/)
(/)
(/)
(/)                            li:i                                               8 li:i 8
li:i 8
li:i
:.r:
:.r:
u li:i 11<
li:i z
z
8 u
                                .:i:
11<  
z                               z    :><      p:;               z                 ~
~
VALVE                                         VALVE          H     8         0               0                               8                       REMARKS
.:i:
                                                                                                                    ~       rr.. (/)
z p:;
                                                                                          . ~~
z VALVE z
H                              ~
VALVE H
8 NllMBER           ti)
8 0
                                &]             CATEGORY               li:i     .:i:                               H       li:i li:i       (NOT TO BE USED FOR RELIEF BASIS)
0  
(/)                                        li:i  >        ::J li:i                      8    ::J    . H    ::J j                                                          8 11<
~
                                                                      ~
8 REMARKS H
N                                                            ,_:i Ol u
~
8u                              H
8
~~
rr.. (/)
NllMBER ti)  
&]
CATEGORY li:i  
.:i:
H li:i li:i (NOT TO BE USED FOR RELIEF BASIS)
(/)
(/)
u    :><
li:i
                                                                                .:i: 8 00 z    11<
::J li:i 8
(/) ()j
::J
                                                                                                              ~~             ~~
. H
A   B c D .E 21CC1           3           F2                   x         12     CK         SA       0                 6             NO 22CC1           3           E2                   x         12     CK         SA       0                 6               NO 23CC1           3           E2                   x         12     CK         SA       0                 6               NO 21CC14           3           E9                   x         1     REL       SA       c                 5               NO 22CC14           3           F9                   x         1     REL       SA       c                 5               NO 21CC15           3           E9                         x   12     BFY       M         L.TH.             7               NO 22CC15           3           F9                         x   12     BFY       M         L.TH.             7               NO 21CC16           3           E9                 x           12     GA         MO       c                 2               NO 22CC16           3           F9                 x           12     GA         MO       c                 2               NO 21CC23           3           GB                         x   1     GL       M         L.TH.             7               NO 22CC23           3           FB                         x   1     GL         M         L.TH.             7               NO 2CC26           3           G6                         x   1     GL         M         L.TH.             7               NO 2CC29           3           E7                         x   1     GL         M         L.TH.             7               NO 2CC37           3           El                         x   10     BFY       M         L.TH.             7           *No 2CC75           3           C2                   x         0.75   REL       SA       c                 5               NO 2CC78           3           C2                         x   3     GL         M         L.TH.             7               NO 2CC100           3           F7                         x   1     GL         M         L.TH.             7               NO 2CC103           3           GS                         x   1     GL         M         L.TH.               7             NO 2CC107           3           F7                         x   2     GL         M         L.TH.               7             NO 2CC113           2           B7             x               3     GL         A         c                 1,3             YES
::J j
                                                                                                                                        -<10   Sec. Ph. "A" Cont. Isol.
8 N
2CC117           2           B7             x               6     GA         MO       0                 1,3             YES
~
                                                                                                                                        <10 Sec. Ph. "B" Cont. Isol.
8 11<.
2CC118           2           B7             x               6     GA         MO       0                 1,3             YES       <:10 Sec. Ph. "B" Cont. Isol.
(/) ()j  
,_:i Ol H
u :><
00
~~ ~~
u u
(/)
.:i: 8 z 11<
A B c D.E 21CC1 3
F2 x
12 CK SA 0
6 NO 22CC1 3
E2 x
12 CK SA 0
6 NO 23CC1 3
E2 x
12 CK SA 0
6 NO 21CC14 3
E9 x
1 REL SA c
5 NO 22CC14 3
F9 x
1 REL SA c
5 NO 21CC15 3
E9 x
12 BFY M
L.TH.
7 NO 22CC15 3
F9 x
12 BFY M
L.TH.
7 NO 21CC16 3
E9 x
12 GA MO c
2 NO 22CC16 3
F9 x
12 GA MO c
2 NO 21CC23 3
GB x
1 GL M
L.TH.
7 NO 22CC23 3
FB x
1 GL M
L.TH.
7 NO 2CC26 3
G6 x
1 GL M
L.TH.
7 NO 2CC29 3
E7 x
1 GL M
L.TH.
7 NO 2CC37 3
El x
10 BFY M
L.TH.
7  
*No 2CC75 3
C2 x
0.75 REL SA c
5 NO 2CC78 3
C2 x
3 GL M
L.TH.
7 NO 2CC100 3
F7 x
1 GL M
L.TH.
7 NO 2CC103 3
GS x
1 GL M
L.TH.
7 NO 2CC107 3
F7 x
2 GL M
L.TH.
7 NO 2CC113 2
B7 x
3 GL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
2CC117 2
B7 x
6 GA MO 0
1,3 YES  
<10 Sec. Ph. "B" Cont. Isol.
2CC118 2
B7 x
6 GA MO 0
1,3 YES  
<:10 Sec. Ph. "B" Cont. Isol.  


COMPONENT COOLING (CC)                               DRAWING NO.       205331                           PAGE 26 of 95     Rev. 0 Cl)
COMPONENT COOLING (CC)
CJ)                       w                                       8 w
DRAWING NO.
8
205331 PAGE 26 of 95 Rev. 0 Cl)
CJ) w 8
w
:r:
:r:
u ril lli z
ril z
                    !<I; z           VALVE z      ><        0:           :z       ~
8 u
VALVE                                       H       8         0           0                   E-!                   REMARKS H                         ...-                8                     ~
lli  
                                                                          . :z~~
~
!<I; z
0:
:z VALVE z
VALVE H
8 0
0  
~
E-!
REMARKS H
8  
~~
Ii. CJ)
Ii. CJ)
NUMBER     CJ)
NUMBER CJ)  
CJ)    ~         CATEGORY               r.LI
~
:;:..
CATEGORY r.LI  
                                                                  !<I;                 H   ril r.LI       (NOT TO BE USED FOR RELIEF BASIS)
!<I; H
                                                                  ~ re r.LI                                 E-! ::i H     ::i
ril r.LI (NOT TO BE USED FOR RELIEF BASIS)
:su  8u                        N H
CJ) r.LI  
CJ)      ~         CJ  ><
~ re E-! ::i H ::i
                                                                  !<I; 8 00 lli CJ)
:s 8
                                                                                    ~~
N  
QI  ...:I QI
~
                                                                                              ~~
CJ) QI
A   B c D E 2CC131     2     B7       x               3       GA         MO       0       1,3     YES
...:I QI H
                                                                                                        -<10 Sec. Ph. "B" Cont. Isol.
CJ ><
2CC136     2     A7       x               6       GA         MO       0       1,3     YES
00
                                                                                                        -<10 Sec. Ph. "B" Cont. Isol.
~~ ~~
2CC138. 3     El               x       0.75     REL         SA*       c       5       NO 2CC147     3     Gl               x       3       SAF         SA       c       5       NO 2CC187     2     B7       x               6       GA         MO       0       1,3     YES
u u
                                                                                                        -<10 Sec. Ph. "B" Cont. Isol.
CJ)
2CC190     2     B7       x               3       GA         MO       0       i,3     YES
!<I; 8
                                                                                                        <10 Sec. Ph. "B" Cont. Isol.
:z lli A
2CC215     2     B6       x               3       PL         A         0       1,3     YES
B c D
                                                                                                        -<10 Sec. Ph. "A" Corit. Isol.
E 2CC131 2
4 2CC317     3     E6               x       1       CK         SA       0       6       NO 2CC318     3     FS                   x   1       GL         M         LC     7       NO 2CC320     3     GS               x       1       CK         SA       0       6       NO 2CC186     2     C7       x     x       0.75     CK         SA       0       1,6     YES 2CC208     2     B7       x     x       0.75     CK         SA       0       1,6     YES
B7 x
3 GA MO 0
1,3 YES  
<10 Sec. Ph. "B" Cont. Isol.
2CC136 2
A7 x
6 GA MO 0
1,3 YES  
<10 Sec. Ph. "B" Cont. Isol.
2CC138.
3 El x
0.75 REL SA*
c 5
NO 2CC147 3
Gl x
3 SAF SA c
5 NO 2CC187 2
B7 x
6 GA MO 0
1,3 YES  
<10 Sec. Ph. "B" Cont. Isol.
2CC190 2
B7 x
3 GA MO 0
i,3 YES  
<10 Sec. Ph. "B" Cont. Isol.
2CC215 2
B6 x
3 PL A
0 1,3 YES  
<10 Sec. Ph. "A" Corit. Isol.
4 2CC317 3
E6 x
1 CK SA 0
6 NO 2CC318 3
FS x
1 GL M
LC 7
NO 2CC320 3
GS x
1 CK SA 0
6 NO 2CC186 2
C7 x
x 0.75 CK SA 0
1,6 YES 2CC208 2
B7 x
x 0.75 CK SA 0
1,6 YES  


VALVE: 2CC113 CATEGORY: A CLASS: 2 e FUNCTION: Containment Isolation from outlet of Excess Letdown Heat Exchanger.
VALVE:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
2CC113 CATEGORY:
BASIS FOR RELIEF: Because the safety-related function of this valve is containment isolation it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
2 e FUNCTION:
VALVE: 2CC117 and 2CC118 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Component Cooling to and return from the Reactor Coolant Pumps.
Containment Isolation from outlet of Excess Letdown Heat Exchanger.
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF: a) These valves cannot be exercised during Power Operation because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a Reactor Trip.
Leak Rate Testing less than each 24 months.
b) Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV code, Section XI for category A valves used for containment isolation.
BASIS FOR RELIEF:
ALTERNATE TESTING:  a) These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.
Because the safety-related function of this valve is containment isolation it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
VALVE: 2CC131 and 2CC136 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Component Cooling to and return from the Reactor Coolant Pumps.
ALTERNATE TESTING:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.
Leak Rate Test per Technical Specification 4.6.1.2.d.
BASIS FOR RELIEF: a) These valves cannot be exercised during Power Operation because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a reactor trip.
VALVE:
b) Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
2CC117 and 2CC118 CATEGORY:
ALTERNATE TESTING: a) These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.
A CLASS:
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
2 FUNCTION:
Page 27 of 95                             Rev. 0
Containment Isolation for Component Cooling to and return from the Reactor Coolant Pumps.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.
BASIS FOR RELIEF:
a)
These valves cannot be exercised during Power Operation because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a Reactor Trip.
ALTERNATE TESTING:
b)
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV code, Section XI for category A valves used for containment isolation.
a)
These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2CC131 and 2CC136 CATEGORY:
A CLASS:
2 FUNCTION:
Containment Isolation for Component Cooling to and return from the Reactor Coolant Pumps.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.
BASIS FOR RELIEF:
a)
These valves cannot be exercised during Power Operation because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a reactor trip.
b)
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
a)
These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 27 of 95 Rev. 0  


VALVE: 2CC187 and 2CC190 CATEGORY: A CLASS: 2
VALVE:
                  *I
2CC187 and 2CC190 CATEGORY:
                  ;,._
A CLASS:
-  FUNCTION:  ConFairunent Isolation for Component Cooling to and from the Reactor Coolant Pump.
2 FUNCTION:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months;     Stroke Time Testing each three months.
*I ConFairunent Isolation for Component Cooling to and from the Reactor Coolant Pump.
BASIS FOR RELIEF:   a) These valves cannot be exercised during Power Operations because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a Reactor Trip.
TEST REQUIREMENTS:
b) Because the safety-rela-t;.ed function of these valves is contairunent isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for contairunent isolation.
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.
ALTERNATE TESTING:   a) These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.
BASIS FOR RELIEF:
bl Leak Rate Test per Technical Specification 4.6.1.2.d.
a)
VALVE: 2CC186 CATEGORY: A/C (Check)
These valves cannot be exercised during Power Operations because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a Reactor Trip.
CLASS: 2 FUNCTION: Overpressure protection for contairunent isolation piping.
b)
TEST REQUIREMENTS:   a) Verify valve operability every three months.
Because the safety-rela-t;.ed function of these valves is contairunent isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
b) Leak Rate Testing less than each 24 months.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for contairunent isolation.
~BASIS FOR RELIEF:     a) Valve cannot be shut without shutting 2CC187. See relief_request for 2CC187.
ALTERNATE TESTING:
b) Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for contairunent isolation.
a)
ALTERNATE TESTING:   a) This valve will be tested during Cold Shutdown and Refueling per Section XI.
These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
bl Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE: 2CC208 CATEGORY: A/C (Check)
VALVE:
CLASS: 2 FUNCTION: Overpressure protection for contairunent isolation piping.
2CC186 CATEGORY:
TEST REQUIREMENTS:   a) Verify valve operability every three months.
A/C (Check)
b) Leak Rate Testing less than each 24 months.
CLASS:
BASIS FOR RELIEF:   a) Valve cannot be shut with out shutting 2CC190. See relief request for 1CC190.
2 FUNCTION:
b) Because the safety-related function of this valve is contairunent isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the e*                        ASME B&PV Code, Section XI for category A valves used for contairunent isolation.
Overpressure protection for contairunent isolation piping.
ALTERNATE TESTING:  a)  This valve will be tested during Cold Shutdown and Refueling per Section XI.
TEST REQUIREMENTS:
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
a)
Page 28 of 95                               Rev. 0
Verify valve operability every three months.
b)
Leak Rate Testing less than each 24 months.  
~BASIS FOR RELIEF:
a)
Valve cannot be shut without shutting 2CC187.
See relief_request for 2CC187.
e*
b)
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for contairunent isolation.
ALTERNATE TESTING:
a)
This valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2CC208 CATEGORY:
A/C (Check)
CLASS:
2 FUNCTION:
Overpressure protection for contairunent isolation piping.
TEST REQUIREMENTS:
a)
Verify valve operability every three months.
b)
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
a)
Valve cannot be shut with out shutting 2CC190.
See relief request for 1CC190.
b)
ALTERNATE TESTING:
a)
Because the safety-related function of this valve is contairunent isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for contairunent isolation.
This valve will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 28 of 95 Rev. 0  


VALVE: 2CC215
VALVE:
            \
2CC215  
CATEGORY: A CLASS: 2
\\
~ FUNCTION: Containment Isolation. Inlet to Excess Letdown Heat Exchanger.
CATEGORY:
TEST REQUIREMENTS: Leak Rate Testing less tha.n each 24 months.
A CLASS:
BASIS FOR RELIEF: Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI, for category A valves used for containment isolation.
2  
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
~
Page 29 of 95                             Rev. 0
FUNCTION:
Containment Isolation.
Inlet to Excess Letdown Heat Exchanger.
TEST REQUIREMENTS:
Leak Rate Testing less tha.n each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI, for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 29 of 95 Rev. 0  


CONTAINMENT SPRAY                                 DRAWING NO.         20S33S
CONTAINMENT SPRAY DRAWING NO.
                                                                            ~~~~~~~~~~~~
20S33S PAGE 30 of 9S Rev. 0
PAGE  30 of 9S    Rev. 0 Ul U)                   J:xl                                     8 J:xl 8                    u
~~~~~~~~~~~~
:r:     J:xl p..
Ul U)
z i<l!
J:xl 8
zH                    z         ><        IZ             :z     ~
J:xl
VALVE                         VALVE                  8         0             0                   8                REMARKS
:r:
                                                                                        ~
J:xl z
H rz.. en
8 u
                                                                            . :z~~
p..  
                                              ~
~
E-!
i<l!
Nl'MBER         en           CATEGORY                                                                (NOT TO BE USED FOR RELIEF BASIS)
z IZ
                        ~                                         i<l!
:z VALVE z
J:xl                            H     J:xl J:xl Ul                         J:xl     :>        :::> J:xl         8   :::>  H :::>
VALVE H
j                                              8 p..               en
8 0
                                                        ~
0  
N u
~
8u                    H Ul u ><
8 REMARKS H  
i<l! 8 00 p.. ~~
~
QI    ,_::i QI
E-!  
                                                                                              ~~
~~
A B c D E 21CS2           3     F4         x         8       GA         MO         c       3       NO 22CS2           3     E4         x         8       GA         MO         c       3       NO 21CS4           2     FS           x       8       CK         SA         c       6       YES 22CS4           2     ES           x       8       CK         SA         c       6       YES 21CSS           2     F6           x       0.7S     REL       SA         c       s       NO 22CSS           2     E6           x       0.7S     REL       SA         c       s       NO 2CS14           3     C4                 x 3       GA         MO         LO       7       NO 2CS16           3     DS         x         3       GA         MO         c       3       NO 2CS17           3     DS         x         3       GA         MO         c       3       NO 21CS21         3     FS           x       3       CK         SA         c       6       YES 22CS21         3     ES           x       3       CK         SA         c       6       YES 2CS26           3     C3           x       0.7S     REL       SA           c       s       NO 21CS36         2     F6         x         8       GA         MO           c       3       YES 22CS36         2     D6         x         8       GA         MO         c       3       YES 21CS47         2     F6                 x 0.7S     GL         M           LO     7       NO 22CS47         2     D6                 x 0.7S     GL         M           LO     7       NO 21CS48         2     F6           x       8       CK         SA           c       6       YES 22CS48           2   E6           x       8       CK         SA           c       6       YES 21CS1           1   G2                 x 10       GA         M           LO     7       NO 22CS1           1   E2                 *X 10       GA         M           LO     7       NO 21CS11           1   F4                 x 2       GL         M           LO     7       NO 22CS11           1   F4                 x 2       GL         M           LC     7       NO
rz.. en Nl'MBER en  
~
CATEGORY J:xl i<l!
H J:xl J:xl (NOT TO BE USED FOR RELIEF BASIS)
Ul J:xl J:xl 8
H j
8 N
~
8 p...
en QI
,_::i QI H
u ><
00
~~ ~~
u u
Ul i<l! 8
:z p..
A B c D
E 21CS2 3
F4 x
8 GA MO c
3 NO 22CS2 3
E4 x
8 GA MO c
3 NO 21CS4 2
FS x
8 CK SA c
6 YES 22CS4 2
ES x
8 CK SA c
6 YES 21CSS 2
F6 x
0.7S REL SA c
s NO 22CSS 2
E6 x
0.7S REL SA c
s NO 2CS14 3
C4 x
3 GA MO LO 7
NO 2CS16 3
DS x
3 GA MO c
3 NO 2CS17 3
DS x
3 GA MO c
3 NO 21CS21 3
FS x
3 CK SA c
6 YES 22CS21 3
ES x
3 CK SA c
6 YES 2CS26 3
C3 x
0.7S REL SA c
s NO 21CS36 2
F6 x
8 GA MO c
3 YES 22CS36 2
D6 x
8 GA MO c
3 YES 21CS47 2
F6 x 0.7S GL M
LO 7
NO 22CS47 2
D6 x 0.7S GL M
LO 7
NO 21CS48 2
F6 x
8 CK SA c
6 YES 22CS48 2
E6 x
8 CK SA c
6 YES 21CS1 1
G2 x
10 GA M
LO 7
NO 22CS1 1
E2  
*X 10 GA M
LO 7
NO 21CS11 1
F4 x
2 GL M
LO 7
NO 22CS11 1
F4 x
2 GL M
LC 7
NO  


e                                                 e                                                                 e SYSTEM     CONTAINMENT SPRAY                               DRAWING NO.       20533S
e e
                                                                          ~~~~~~~~~~~~
e SYSTEM CONTAINMENT SPRAY DRAWING NO.
PAGE   31 of 95   Rev. 0 CJ)
20533S  
CJ)                   l'.Ll                                   8 l'.Ll 8
~~~~~~~~~~~~ PAGE 31 of 95 Rev. 0 CJ)
CJ) l'.Ll 8
l'.Ll
::r:
::r:
CJ l'.Ll p,
l'.Ll z
z
8 CJ p,  
                      .:i:
~
z                     z        ><        IZ           z       ~
.:i:
VALVE                       VALVE       H         8         0           0                   8                 REMARKS 8                   ~     &#xb5;..
z IZ z
                                                                            ~*~
VALVE z
H                    ~
VALVE H
8 0
0  
~
8 REMARKS H
~
8  
~*~  
&#xb5;..
CJ)
CJ)
NtTMBER     CJ)
NtTMBER CJ)  
                      ~       CATEGORY               l'.Ll     .:i:                 H     l'.Ll l'.Ll (NOT TO BE USED FOR RELIEF BASIS)
~
                                                      ~
CATEGORY l'.Ll  
                                                                ~~
.:i:
CJ)                         l'.Ll                                 8   ::::>  H     ::::>
H l'.Ll l'.Ll (NOT TO BE USED FOR RELIEF BASIS)
:&sect;   8u                    N H                   CJ >< 00 CJ) QI    H QI u                           CJ)                 .:i: 8     z p, ~~        ~~
CJ) l'.Ll  
B c D E 2CS35       1     B2                 x .2       GL         M         LC     7       NO 21CS44       2     G7                 x 8         GA         M         LC     7       NO 22CS44       2     E7                 x 8         GA         M         LC     7       NO 21CS6       2     G7                 x *s       GA         M         LO     7       NO 22CS6       2     E7                 x 8         GA         M         LO     7         NO 21CS20       2     GS                 x 3.       DIA         M         LO     7       NO 22CS20       2     FS                 x 3         DIA         M         LO     7       NO 2CS31       2     DS                 x 3         CK         M         LC     7       NO
~
~~
8 H
:&sect; 8
N CJ) QI H QI H
CJ ><
00  
~~ ~~
u u
CJ)  
.:i: 8 z p, A
B c D
E 2CS35 1
B2 x. 2 GL M
LC 7
NO 21CS44 2
G7 x
8 GA M
LC 7
NO 22CS44 2
E7 x
8 GA M
LC 7
NO 21CS6 2
G7 x *s GA M
LO 7
NO 22CS6 2
E7 x
8 GA M
LO 7
NO 21CS20 2
GS x
: 3.
DIA M
LO 7
NO 22CS20 2
FS x
3 DIA M
LO 7
NO 2CS31 2
DS x
3 CK M
LC 7
NO  


VALVE: 21CS4 and 22CS4 CATEGORY: c (Check)
VALVE:
CLASS: 2 FUNCTION: To provide directional flow of water into the containment spray headers.
21CS4 and 22CS4 CATEGORY:
TEST REQUIREMENTS:   Verify valve operability every three months.
c (Check)
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation or Cold Shutdown without spraying down the containment, causing equipment and lagging damage requiring extensive clean-up and repair. The full flow test connection is connected to the refueling cavity and can only be used during Refueling.
CLASS:
ALTERNATE TESTING:   These valves will be tested during Refueling per Section XI.
2 FUNCTION:
VALVE: 21CS48 and 22CS48 CATEGORY: C (Check)
To provide directional flow of water into the containment spray headers.
CLASS: 2 FUNCTION: To provide proper directional flow of water into the Containment Spray Headers.
TEST REQUIREMENTS:
TEST REQUIREMENTS:   Verify valve operability every three months.
Verify valve operability every three months.
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation or Cold Shutdown without spraying down the containment, causing equipment and lagging damage requiring extensive clean-up and repair. The full flow test connection is connected to the refueling cavity and can only be used during Refueling.
BASIS FOR RELIEF:
ALTERNATE TESTING:   These valves will be tested during Refueling per Section XI.
These valves cannot be exercised during Power Operation or Cold Shutdown without spraying down the containment, causing equipment and lagging damage requiring extensive clean-up and repair.
VALVE: 21 and 22CS21 CATEGORY: C (Check)
The full flow test connection is connected to the refueling cavity and can only be used during Refueling.
CLASS: 2 FUNCTION: To prevent backflow into the spray additive tank. The safety-related position is open to allow the caustic solution in the Spray Additive Tank to be educted into the C.S. System and sprayed into the containment.
ALTERNATE TESTING:
TEST REQUIREMENTS:   Verify valve operability every three months.
These valves will be tested during Refueling per Section XI.
BASIS FOR RELIEF:   Only partial stroke is possible due to the limited size of the recirc line.
VALVE:
ALTERNATE TESTING:   These valves will be part st.eke tested quarterly per Section XI.
21CS48 and 22CS48 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To provide proper directional flow of water into the Containment Spray Headers.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation or Cold Shutdown without spraying down the containment, causing equipment and lagging damage requiring extensive clean-up and repair.
The full flow test connection is connected to the refueling cavity and can only be used during Refueling.
ALTERNATE TESTING:
These valves will be tested during Refueling per Section XI.
VALVE:
21 and 22CS21 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To prevent backflow into the spray additive tank.
The safety-related position is open to allow the caustic solution in the Spray Additive Tank to be educted into the C.S. System and sprayed into the containment.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Only partial stroke is possible due to the limited size of the recirc line.
ALTERNATE TESTING:
These valves will be part st.eke tested quarterly per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
VALVE: 21 and 22CS36 CATEGORY: B CLASS: 2 FUNCTION: To allow the RHR (LPSI) pumps to pump into the CS System when in recirculation mode.
VALVE:
TEST REQUIREMENTS:   Valve exercising each three months;   Stroke Time Testing each three months.
21 and 22CS36 CATEGORY:
BASIS FOR RELIEF:   The valve will be tested during Power Operation. However, it cannot be opened when the RHR System is in service without spraying down the Containment, causing equipment and lagging damage requiring extensive clean-up and repair.
B CLASS:
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI when the RHR system is not in service.
2 FUNCTION:
Page 32 of 95                             Rev. O
To allow the RHR (LPSI) pumps to pump into the CS System when in recirculation mode.
TEST REQUIREMENTS:
Valve exercising each three months; Stroke Time Testing each three months.
BASIS FOR RELIEF:
The valve will be tested during Power Operation.
However, it cannot be opened when the RHR System is in service without spraying down the Containment, causing equipment and lagging damage requiring extensive clean-up and repair.
ALTERNATE TESTING:
These valves will be tested during Cold Shutdown and Refueling per Section XI when the RHR system is not in service.
Page 32 of 95 Rev. O  


SYSTEM;______c_o_N_T_R~O_L_A_I_R__(_c_A_)__________~----------~             DRAWING NO.           205347                       PAGE   33 of 95   Rev. 0
SYSTEM;__ ____
c_o_N_T_R~O_L_A_I_R __ (_c_A_) __________ ~----------~ DRAWING NO.
205347 PAGE 33 of 95 Rev. 0
(/)
(/)
(/)                       ril                                         8 ril 8
(/)
ril 8
ril
:r:
:r:
u ril ti.
ril z
z
8 u
                                ,:(
ti.  
z                         z         :>!        ~            z         ~
~
VALVE                                       VALVE        H
,:(
                                                          ........ 8         0 8
z  
0
~
                                                                                                        ~
z VALVE z
8 rr.. (/)                 REMARKS
VALVE H
                                                                                        . z~ ~*
8 0
H Nl'MBER           (/)
0  
                                &sect;           CATEGORY               ril
~
:;:..
8 REMARKS H
                                                                                ,:(                     H   ril ril     (NOT TO BE USED FOR RELIEF BASIS)
8
                                                                                ~ re                E-1::>
~ ~*
(/)                                    ril                                              HP j                                                                              (/) QI
rr.. (/)
                                                                      ~
Nl'MBER
                                                                                                            ,_::i QI CJ 8CJ                        N H
(/)  
&sect; CATEGORY ril  
,:(
H ril ril (NOT TO BE USED FOR RELIEF BASIS)
(/)
(/)
u   :>!
ril
                                                                                ,:( E-1 00 ti.   ~~      ~ gi A B c D *E 21CA330           2         B5           x             2         GA         A         0         1,3     YES
~ re E-1::>
                                                                                                                      -<10 Sec. Ph. "A" Cont. Isol.
HP j
4 22CA330           2         B5           x             2         GA         A         0         1,3     YES       -
8 N
                                                                                                                      <10 Sec. Ph. "A" Cont. Isol.
~
4
(/) QI
,_::i QI H
u :>!
00
~~ ~ gi CJ CJ
(/)
,:( E-1 z ti.
A B c
D *E 21CA330 2
B5 x
2 GA A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 22CA330 2
B5 x
2 GA A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4  


VALVE: 21CA330 and 22CA330 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Containment Control Air Headers.
VALVE:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
21CA330 and 22CA330 CATEGORY:
BASIS FOR RELIEF: Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical SPecifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for the containment isolation.
A CLASS:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
2 FUNCTION:
Page 34 of 95                             Rev. 0
Containment Isolation for Containment Control Air Headers.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical SPecifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for the containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 34 of 95 Rev. 0  


SYSTEM DEMINERALIZED WATER - RESTRICTED AREA (DR)         DRAWING NO.           205246
SYSTEM DEMINERALIZED WATER -
                                                                          ~~.;::_:_.=.....::....:.~~~~~~~~
RESTRICTED AREA (DR)
PAGE 35 of 95   Rev. 0
DRAWING NO.
                                              ~
205246  
~~.;::_:_.=.....::....:.~~~~~~~~ PAGE 35 of 95 Rev. 0  
~
U)
U)
U)
U)                      IL!                                     8 fil 8                        u
IL!
:r:   IL!
8 fil
Pi z
:r:
                      .:i:
IL!
z                         z    ><      IZ               z       ~
z 8
VALVE                         VALVE         H     8       0               0                 8                   REMARKS
u Pi  
                                                                                        ~
~
                                                                            ~&sect; H                        ~
.:i:
8                              Ii< Cl)
z IZ z
CATEGORY                                                                  (NOT TO BE USED FOR RELIEF BASIS)
VALVE z
NUMBER            ~
VALVE H
Cl)                                  IL!     .:i:                     H     IL! IL!
8 0
                                                              ~ Pi U)                             &#xb5;:i                   IL!             8 ::::i H ::J j
0  
                                                      ~
~
QI   ,_:i QI u
8 REMARKS H
8 u
~
N H
8
U) u ><
~&sect; Ii< Cl)
                                                              .:i: 8
NUMBER Cl)  
                                                                        '  00 z Pi, U)
~
                                                                                    ~~      ~~
CATEGORY IL!  
B   c D E 2DR29         2     D2       x             4     GL             A       c       1,3       YES     <10 Sec. Ph. "A" Cont. Isol.
.:i:
4
H IL! IL!
(NOT TO BE USED FOR RELIEF BASIS)
U)  
&#xb5;:i  
~
IL!
8
::::i H
::J j
8 N
~
Pi U) QI  
,_:i QI H
u ><
00
~~ ~~
u u
U)  
.:i: 8 z Pi, A
B c D
E 2DR29 2
D2 x
4 GL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4  


VALVE: 2DR29 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation valve for Containment Demineralized Water Header.
VALVE:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
2DR29 CATEGORY:
BASIS FOR RELIEF: Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
2 FUNCTION:
Page 36 of 95                             Rev. 0
Containment Isolation valve for Containment Demineralized Water Header.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 36 of 95 Rev. 0  


SYSTEM-___;;F_I_RE
SYSTEM-___;;F_I_RE P_~_O_TE_C_T_I_O_N __________________________ ~
___P_~_O_TE_C_T_I_O_N__________________________~                   205222                           PAGE 37 of 95   Rev. 0 Cl)
205222 PAGE 37 of 95 Rev. 0 Cl)
Cl)                       lil                           8 lil                       ::r:   lil                   z 8                         u       p..
Cl) lil 8
                                    .:i:
lil
z z*     >t n::       z       ~
::r:
VALVE                                       VALVE        H       8   0         0
lil z
                                                                                            ~   r:r..
8 u
8                   REMARKS
p..  
                                                                                  ~~
~
H                        ~
.:i:
8                            Cl)
z*  
NUMBER                                     CATEGORY                                                       (NOT TO BE USED FOR RELIEF BASIS)
>t n::
                                                                          ~ re Cl)
z VALVE z
                                    &sect;                                lil                    H    lil lil
VALVE H
                                                                      ~
8 0
                      .Cl)                                    lil                        8 ::i H
0  
::&sect;                                   N                 ,
~
u 8u                        H Cl) u >t
8 REMARKS H
                                                                          .:i: 8 00 z p..
~
Ul OI
8
                                                                                          ~~
~~
                                                                                                  ..:! OI
r:r..
                                                                                                  ~~
Cl)
A   B c D E 2FP147               2           B3         x             4       PL     A     c     1,3     YES       <10 Sec. Ph. "A" Cont. Isol.
NUMBER Cl)
4
&sect; CATEGORY lil
~ re H
lil lil (NOT TO BE USED FOR RELIEF BASIS)  
.Cl) lil  
~
8
::i H ::>
::&sect; 8
N Ul OI
..:! OI H
u >t 00
~~ ~~
u u
Cl)
.:i: 8 z p..
A B c D E 2FP147 2
B3 x
4 PL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4  


VALVE: 1FP147 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation valve for Containment Fire Protection Header.
VALVE:
TEST REQUIREMENTS: Leak Rate Tes.ting less than each 24 months.
1FP147 CATEGORY:
BASIS FOR RELIEF: Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
2 FUNCTION:
P&#xb5;ge 38 of 95                           Rev. 0
Containment Isolation valve for Containment Fire Protection Header.
TEST REQUIREMENTS:
Leak Rate Tes.ting less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
P&#xb5;ge 38 of 95 Rev. 0  


DRAWING NO. NO PIPING DIAGRAM                           PAGE 39 of 95   Rev. 0 Ul Ul                 &#xb5;:i                                     8
DRAWING NO.
                  &#xb5;:i 8
NO PIPING DIAGRAM PAGE 39 of 95 Rev. 0 Ul Ul  
:i::
&#xb5;:i 8  
u
&#xb5;:i
                                              &#xb5;:i p..
:i::  
:z
&#xb5;:i
                  ,:(               :z       ><      ~             z       gj VALVE           :z     VALVE       H         8       0             0                                           REMARICS
:z 8
                                                                              ~
u p..
                                    ...._,                                                  8 rr..
gj
                                                                  ~~
,:(
H                                    8                                  Ul Nl'MBER   Ul
:z  
                  ~     CATEGORY               &#xb5;:i
~
                                                        @ &#xb5;:i                 H     &#xb5;:i   &#xb5;:i       (NOT TO BE USED FOR RELIEF BASIS)
z VALVE
Ul                     &#xb5;:i       !>                        8   ::::>  H     ::::>
:z VALVE H
j                                          8   p..                     ....:I
8 0
                                              ~
0  
N u
~
8u                H Ul u  ><
8 REMARICS H
                                                        ,:( 8
8
                                                                '  00
~~
rr.. Ul Nl'MBER Ul  
~
CATEGORY  
&#xb5;:i  
@ &#xb5;:i H  
&#xb5;:i  
&#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
Ul  
&#xb5;:i 8
H j
8 N
~
8 p..
Ul QI
....:I QI H
u ><
00
~~ ~~
u u
Ul  
,:( 8
:z p..
:z p..
Ul QI
A B c D E Fuel Trans 3
                                                                          ~~        ~~
N/A x
QI A B c D E Fuel Trans 3   N/A             x 12         GA         M       LC       7       NO           Containment Secondary Isolation Tube IV                                                                                           (Primary is blank flange)
12 GA M
LC 7
NO Containment Secondary Isolation Tube IV (Primary is blank flange)  


SYSTEM;..__.;.;;S~T_E_AM
SYSTEM;..__.;.;;S~T_E_AM __
__G_EN_E_RA_T_O_R_D_RA_I_N_AN_D_B_L_O_WD_O_WN_"""'(_G_B~)_ _          DRAWING NO.         205325                           PAGE  40 of 95      Rev. 0
G_EN_E_RA_T_O_R_D_RA_I_N_AN_D_B_L_O_WD_O_WN_"""'(_G_B~) __ DRAWING NO.
                                                                                                              ----------~-~
205325  
U)
----------~-~ PAGE 40 of 95 Rev. 0 U)
U)                                       li'l                                       8 li'l 8
U) li'l 8
li'l
:r:
:r:
u li'l p.,
li'l z
z
8 u
                                    !Cl!
p.,  
z                                         z        ><        P:             z       ~
~
VALVE                         H VALVE                  H        8         0             0       gJ &#xb5;,
!Cl!
8                      REMARKS
z P:
                                                                                                            . z~~
z VALVE z
                                                                            ~
VALVE H
8                             U)
8 0
NUMBER                U)
0 gJ 8
                                    ~               CATEGORY                          li'l
REMARKS H
:38                    H  li'l li'l      (NOT TO BE USED FOR RELIEF BASIS)
~
                                                                                        ~
8  
U)                                                li'l                      li'l          8P    HP t'I                      p.,              QI H QI
~~  
::s u
&#xb5;,
8u                                        H U) u!Cl! ><
8 00 p.,
U)
U)
                                                                                                                      ~ gJ ~ gJ A     B   c D E x                                                          c 21GB4               2       D4                                       3       PL         A                     1,3 4
NUMBER U)
YES
~
                                                                                                                                      -<10 Sec. Ph. "A" Cont. Isol.
CATEGORY li'l
22GB4               2       D4             x                         3       PL         A             c       1,3   YES
:3 li'l H
                                                                                                                                      -<10 Sec. Ph. "A" Cont. Isol.
li'l li'l (NOT TO BE USED FOR RELIEF BASIS)
U) li'l
~
8P HP
::s 8
t'I 8
p.,.
U) QI H QI H
u ><
00
~ gJ  
~ gJ u
u U)
!Cl! 8 z p.,
A B c D E 21GB4 2
D4 x
3 PL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 22GB4 2
D4 x
3 PL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4*
4*
23GB4               2       D4             x                         3       PL         A             c       1,3   YES
23GB4 2
                                                                                                                                      -<10 Sec. Ph. "A" Cont .. Isol.
D4 x
4 24GB4               2       D4               x                       3       PL         A             c       1,3   YES       -
3 PL A
                                                                                                                                        <10 Sec. Ph. "A" Cont. Isol.
c 1,3 YES  
4
<10 Sec. Ph. "A" Cont.. Isol.
4 24GB4 2
D4 x
3 PL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4  


VALVE: 21 - 24GB4   (4 Valves)
VALVE:
CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation of Steam Generator Drain and Blowdown Lines.
21 -
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.*
24GB4 (4 Valves)
BASIS FOR RELIEF: Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
CATEGORY:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
A CLASS:
Page 41 of 95                             Rev. 0
2 FUNCTION:
Containment Isolation of Steam Generator Drain and Blowdown Lines.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.*
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 41 of 95 Rev. 0  


e                                                   e                                                               e SYSTEM     MAIN STEAM       (MS)                             DRAWING NO.         205303
e e
                                                                              ~~~~~~~~~~~~
e SYSTEM MAIN STEAM (MS)
PAGE 42 of 95   Rev. O U)
DRAWING NO.
U)                       rzl                                     8 rzl 8
205303  
~~~~~~~~~~~~ PAGE 42 of 95 Rev. O U)
U) rzl 8
rzl
::r:
::r:
u rzl A<
rzl z
z
8 u
                        .:i:
A<  
z                       z      ><          0::           z     ~
~
VALVE                             VALVE      H     8           0             0     gj         8               REMARKS H                                                                       r..
.:i:
                                                                              . i~
z 0::
                                                ~
z VALVE z
8                                U)
VALVE H
NUMBER       Cl)
8 0
                        ~           CATEGORY           rzl         .:i:                 H     rLI rLI (NOT TO BE USED FOR RELIEF BASIS)
0 gj 8
U)                               w     :;:..      ::::> rLI         8 ::::> H ::::>
REMARKS H  
j      8u                        N H      ~
~
8 A<
8 i~
u ><        00 U) ()I   ,_:i OI u                               U)     :;:..      .:i: 8       z A< ~ gj    ~~
r.. U)
A B   c D E 21MS7       2     F2               x       2     GA         A             c     3,4       NO 22MS7       2     C2               x       2     GA         A             c     3,4       NO 23MS7       2     E2               x       2     GA         A             c     3,4       NO 24MS7       2     D2               x       2     GA         A             c     3,4       NO 21MS11     2     E2                 x     6     SAF         SA           c     5         NO 22MS11     2     D2                 x     6     SAF       *SA           c     5         NO 23MS11     2     F2                 x     6     SAF         SA           c     5         NO 24MS11     2     C2                 x     6     SAF         SA           c     5         NO 21MS12     2     E2                 x     6     SAF         SA           c     5         NO 22MS12     2     D2                 x     6     SAF         SA           c       5       NO 23MS12     2     F2                 x     6     SAF         SA           c       5       NO 24MS12     2     C2                 x     6     SAF         SA         ' c.     5       NO 21MS13     2     E2                 x     6     SAF         SA           c       5       NO 22MS13     2     D2                 x     6     SAF         SA           c       5       NO 23MS13     2     F2                 x     6     SAF         SA           c       5       NO 24MS13     2     C2                 x     6     SAF         SA           c       5       NO 21MS14     2     E2                 x     6     SAF         SA           c       5       NO 22MS14     2     D2                 x     6     SAF         SA           c       5       NO 23MS14     2     F2                 x     6     SAF         SA           c       5       NO 24MS14     2     C2                 x     .6     SAF         SA           c       5         NO 21MS15     2     E2                 x     6     SAF         SA           c       5       NO 22MS15     2     D2                 x     6     SAF         SA           c       5         NO
NUMBER Cl)  
~
CATEGORY rzl  
.:i:
H rLI rLI (NOT TO BE USED FOR RELIEF BASIS)
U) w
::::> rLI 8
H j
8 N  
~
8 A<.
U) ()I  
,_:i OI H
u ><
00
~ gj
~~
u u
U)  
.:i: 8 z A<
A B
c D
E 21MS7 2
F2 x
2 GA A
c 3,4 NO 22MS7 2
C2 x
2 GA A
c 3,4 NO 23MS7 2
E2 x
2 GA A
c 3,4 NO 24MS7 2
D2 x
2 GA A
c 3,4 NO 21MS11 2
E2 x
6 SAF SA c
5 NO 22MS11 2
D2 x
6 SAF  
*SA c
5 NO 23MS11 2
F2 x
6 SAF SA c
5 NO 24MS11 2
C2 x
6 SAF SA c
5 NO 21MS12 2
E2 x
6 SAF SA c
5 NO 22MS12 2
D2 x
6 SAF SA c
5 NO 23MS12 2
F2 x
6 SAF SA c
5 NO 24MS12 2
C2 x
6 SAF SA  
' c.
5 NO 21MS13 2
E2 x
6 SAF SA c
5 NO 22MS13 2
D2 x
6 SAF SA c
5 NO 23MS13 2
F2 x
6 SAF SA c
5 NO 24MS13 2
C2 x
6 SAF SA c
5 NO 21MS14 2
E2 x
6 SAF SA c
5 NO 22MS14 2
D2 x
6 SAF SA c
5 NO 23MS14 2
F2 x
6 SAF SA c
5 NO 24MS14 2
C2 x  
.6 SAF SA c
5 NO 21MS15 2
E2 x
6 SAF SA c
5 NO 22MS15 2
D2 x
6 SAF SA c
5 NO  


SYSTEM   MAIN STEAM (MS)                           DRAWING       N0.~-=20~5~3~0~3::;__~~~~~~~           PAGE 43 of 95   Rev. 0
SYSTEM MAIN STEAM (MS)
                                          ~
DRAWING N0.~-=20~5~3~0~3::;__~~~~~~~ PAGE 43 of 95 Rev. 0  
~
U)
U)
U)               &#xb5;:i                                     E-<
U)  
                        &#xb5;:i E-<
&#xb5;:i E-<  
::r:
&#xb5;:i
u
::r:  
                                                &#xb5;:i 11<
&#xb5;:i z
z
E-<
                        <l; z                 z      :>!      p:;             z       ~
u 11<  
VALVE                       VALVE            E-<     0               0                 E-<                 REMARKS
~
                                                                                  ~
<l; z
H E-<                           &#xb5;.,
p:;
                                                                    . ~~
z VALVE z
H                ~                                                  U)
VALVE H
NUMBER          U)
E-<
                        @    CATEGORY          &#xb5;:i      <l;                      H    &#xb5;:i  &#xb5;:i    (NOT TO BE USED FOR RELIEF BASIS)
0 0  
U)                    &#xb5;:i    >        :::> &#xb5;:i            E-< :::> H :::>
~
j                                      t; g:
E-<
                                                ~
REMARKS H
QI  ,_:i QI u
~
8 u
E-<  
N H
~~  
U)              <l;  E-<
&#xb5;.,
00 z 11<
U)
U)
                                                                              ~~       ~~
NUMBER U)
A B   c 0 E 23MS15       2     F2         x     6     SAF       SA           c       5       NO 24MS15       2     C2         x     6     SAF       SA           c       5         NO 21MS18       2     F2       x       3     GA       A             c     3,4       NO 22MS18       2     C2       x       3     GA       A             c     3,4       NO 23MS18       2     E2       x       3     GA       A             c     3,4       NO 24MS18       2     D2       x       3     GA       A             c     3,4       NO 21MS45       2     Fl             x 6     GA       M             LO       7       NO 23MS45         2   El             x 6     GA       M             LO       7       NO 21MS46       2     G2         x     6     CK       SA           c       6       NO 23MS46         2   G2         x     6     CK       SA           c       6       NO 2MS52         3   G3       x       4     BFY       SOL           0       2       YES 2MS53         3   G3       x       4     GA       A             0       2       YES 2MS132         2   G2       x       6     GA       A             c     3,4       NO 21MS167       2   F2       x       32   GA       H/S           0       3       YES
CATEGORY
                                                                                                -<5 Sec.
&#xb5;:i
22MS167       2   C2       x       32   GA       H/S           0       3       YES
<l; H
                                                                                                  <5 Sec.
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
23MS167       2   02       x       32   GA       H/S           0       3       YES
U)
                                                                                                -<5 Sec.
&#xb5;:i
24MS167       2   E2       x       32   GA       H/S           0       3       YES
&#xb5;:i E-< :::>
                                                                                                  <5 Sec.
H j
21MS169       2   F2       x       2     GA       A             c     3,4       YES 22MS169       2   C2       x       2     GA       A             c     3,4       YES 23MS169       2   02       x       2     GA       A             c     3,4       YES 24MS169       2   E2       x       2     GA       A             c     3,4       YES 21MS171       2   F2       x       2     GA       A             c     3,4         YES
8 N
~
t; g:.
U) QI
,_:i QI H
00
~~ ~~
u u
U)
<l; E-<
z 11<
A B c 0
E 23MS15 2
F2 x
6 SAF SA c
5 NO 24MS15 2
C2 x
6 SAF SA c
5 NO 21MS18 2
F2 x
3 GA A
c 3,4 NO 22MS18 2
C2 x
3 GA A
c 3,4 NO 23MS18 2
E2 x
3 GA A
c 3,4 NO 24MS18 2
D2 x
3 GA A
c 3,4 NO 21MS45 2
Fl x
6 GA M
LO 7
NO 23MS45 2
El x
6 GA M
LO 7
NO 21MS46 2
G2 x
6 CK SA c
6 NO 23MS46 2
G2 x
6 CK SA c
6 NO 2MS52 3
G3 x
4 BFY SOL 0
2 YES 2MS53 3
G3 x
4 GA A
0 2
YES 2MS132 2
G2 x
6 GA A
c 3,4 NO 21MS167 2
F2 x
32 GA H/S 0
3 YES  
<5 Sec.
22MS167 2
C2 x
32 GA H/S 0
3 YES  
<5 Sec.
23MS167 2
02 x
32 GA H/S 0
3 YES  
<5 Sec.
24MS167 2
E2 x
32 GA H/S 0
3 YES  
<5 Sec.
21MS169 2
F2 x
2 GA A
c 3,4 YES 22MS169 2
C2 x
2 GA A
c 3,4 YES 23MS169 2
02 x
2 GA A
c 3,4 YES 24MS169 2
E2 x
2 GA A
c 3,4 YES 21MS171 2
F2 x
2 GA A
c 3,4 YES  


SYSTEM.~--MA~I_N........;:;S~T~E_AM~--=-(M~S~)~~----~~--~~--~----         DRAWING NO.       205303                           PAGE  44 of 95    Rev. 0
SYSTEM.~--MA~I_N........;:;S~T~E_AM~--=-(M~S~)~~----~~--~~--~----
                                                                                        ~----------~--------~
DRAWING NO.
Cl)
205303  
Cl)                           l:il                                     E-l l:il                           ::r:     l:il                             z E-l                           u         ii.
~----------~--------~ PAGE 44 of 95 Rev. 0 Cl)
ice zH                              z       ><        P::           z       ~
Cl) l:il E-l l:il
VALVE                                 VALVE              H       E-l       0             0                 E-l                 REMARKS E-l                   ~
::r:
                                                                                        . z~~
l:il z
                                                          ~
E-l u
ii.  
~
ice z
P::
z VALVE z
VALVE H
E-l 0
0  
~
E-l REMARKS H
~
E-l  
~~
Iii Cl)
Iii Cl)
NUMBER           Cl)
NUMBER Cl)  
                            &sect;           CATEGORY                     l:il     ice                   H   l:il l:il   (NOT TO BE USED FOR RELIEF BASIS)
&sect; CATEGORY l:il ice H
Cl)                                   l:il     ::>      ::i l:il           E-l ::i H ;:i
l:il l:il (NOT TO BE USED FOR RELIEF BASIS)
                    ~       8                                       ~
Cl) l:il
N                  E-l ii.           Ul OI   ,..:i OI H                   u ><       00 g:J ~
::i l:il E-l ::i H  
CJ     CJ                             Cl)                 ice E-l       ii.         ~~
;:i  
A B   c   D   E 22MS171       2     C2               x             2       GA         A           c     3,4       YES 23MS171       2     D2             *x               2       GA         A           c     3,4       YES 24MS171       2     E2               x             2       GA         A           c     3,4       YES 21MS168     NONE     F3               x             4       3-WAY       SOL
~
* 3      YES
8 N
* Open to both ports 11 - 14MS169 and 11 - 14MS171 22MS168     NONE     E3             x             4       3-WAY       SOL
~
* 3      YES 23MS168     NONE     C3               x             4       3-WAY     *SOL
E-l ii..
* 3      YES 24MS168     NONE     B3               x             4       3-WAY       SOL
Ul OI  
* 3      YES
,..:i OI H
u ><
00 g:J ~ ~~
CJ CJ Cl) ice E-l z ii.
A B c D
E 22MS171 2
C2 x
2 GA A
c 3,4 YES 23MS171 2
D2  
*x 2
GA A
c 3,4 YES 24MS171 2
E2 x
2 GA A
c 3,4 YES 21MS168 NONE F3 x
4 3-WAY SOL 3
YES
* Open to both ports 11 -
14MS169 and 22MS168 NONE E3 x
4 3-WAY SOL 3
YES 11 -
14MS171 23MS168 NONE C3 x
4 3-WAY  
*SOL 3
YES 24MS168 NONE B3 x
4 3-WAY SOL 3
YES  


VALVE: 2MS52 CATEGORY: B CLASS: 2 FUNCTION: Steam shutoff for the 13AF Pump Turbine to drive the pump.
VALVE:
TEST REQUIREMENTS:     Stroke Time Testing each three months.
2MS52 CATEGORY:
BASIS FOR RELIEF:   This is a passive valve. It is always in the position required to allow the pump to operate during an indident.
B CLASS:
ALTERNATE TESTING:     None.
2 FUNCTION:
VALVE: 2MS53 CATEGORY: B CLASS: 2 FUNCTION: To regulate the steam flow to the 13AF Pump Turbine t_o maintain a constant pump speed.
Steam shutoff for the 13AF Pump Turbine to drive the pump.
TEST REQUIREMENTS:     Stroke Time Testing each three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   This is a Turbine Governor Valve - stroke time does not provide any data on valve degradation.
Stroke Time Testing each three months.
ALTERNATE TESTING:     Proper system operation during monthly testing of 23 Auxiliary Feedwater Pump will verify proper valve operation.
BASIS FOR RELIEF:
VALVE: 21 - 24MS167     (4 Valves)
This is a passive valve.
CATEGORY: B CLASS: 2 FUNCTION: Main Stearn Isolation Valves.
It is always in the position required to allow the pump to operate during an indident.
TEST REQUIREMENTS:     Stroke Time Testing each three months.
ALTERNATE TESTING:
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation. Shutting one valve will cause a Stearn Flow/Feed Flow mismatch in the corresponding SG because the Stearn Flow would go to zero. This would cause a reactor trip.
None.
ALTERNATE TESTING:     These valves will be tested following Cold Shutdown and Refueling per Section XI.
VALVE:
VALVE: 21 - 24MS169 and 21 - 24MS171     (8 Valves)
2MS53 CATEGORY:
CATEGORY: B CLASS: 2 FUNCTION: Opening these valves is the back-up method of shutting the Main Stearn Stop Valves (MS167 's) .
B CLASS:
TEST REQUIREMENTS:     Stroke Time Testing each three months.; Fail Safe Testing each three months.
2 FUNCTION:
BASIS FOR RELIEF:   Testing of one of these valves will result in the closure of the corresponding Main Stearn Stop (21 - 24MS167). See relief for 21 - 24MS167.
To regulate the steam flow to the 13AF Pump Turbine t_o maintain a constant pump speed.
ALTERNATE TESTING:     These valves will be tested following Cold SHutdown and Refueling per Section XI.
TEST REQUIREMENTS:
Page 45 of 95                           Rev. 0
Stroke Time Testing each three months.
BASIS FOR RELIEF:
This is a Turbine Governor Valve - stroke time does not provide any data on valve degradation.
ALTERNATE TESTING:
Proper system operation during monthly testing of 23 Auxiliary Feedwater Pump will verify proper valve operation.
VALVE:
21 -
24MS167 (4 Valves)
CATEGORY:
B CLASS:
2 FUNCTION:
Main Stearn Isolation Valves.
TEST REQUIREMENTS:
Stroke Time Testing each three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation.
Shutting one valve will cause a Stearn Flow/Feed Flow mismatch in the corresponding SG because the Stearn Flow would go to zero.
This would cause a reactor trip.
ALTERNATE TESTING:
These valves will be tested following Cold Shutdown and Refueling per Section XI.
VALVE:
21 -
24MS169 and 21 -
24MS171 (8 Valves)
CATEGORY:
B CLASS:
2 FUNCTION:
Opening these valves is the back-up method of shutting the Main Stearn Stop Valves (MS167 's).
TEST REQUIREMENTS:
Stroke Time Testing each three months.;
Fail Safe Testing each three months.
BASIS FOR RELIEF:
Testing of one of these valves will result in the closure of the corresponding Main Stearn Stop (21 -
24MS167).
See relief for 21 -
24MS167.
ALTERNATE TESTING:
These valves will be tested following Cold SHutdown and Refueling per Section XI.
Page 45 of 95 Rev. 0  


VALVE: 21 - 24MS168 CATEGORY: B CLASS: NONE e FUNCTION: Three way valve used to direct steam in the closing of 21 - 24MS167 to vent through 21 - 2 4MS169 and 21 - 24MS171.
VALVE:
TEST REQUIREMENTS:   Stro~e Time Testing each three months.
21 -
BASIS FOR RELIEF:   This is a passive valve always maintained in its safety-related position (i.e. open to the MS169s and MS17ls).
24MS168 CATEGORY:
ALTERNATE TESTING:   None.
B CLASS:
            \
NONE e FUNCTION:
Page 46 of 95                             Rev. 0
Three way valve used to direct steam in the closing of 21 - 24MS167 to vent through 21 - 2 4MS169 and 21 -
24MS171.
TEST REQUIREMENTS:
Stro~e Time Testing each three months.
BASIS FOR RELIEF:
This is a passive valve always maintained in its safety-related position (i.e. open to the MS169s and MS17ls).
ALTERNATE TESTING:
None.  
\\
Page 46 of 95 Rev. 0  


SYSTEM   NITROGEN   (NT)                                     DRAWING NO. 205301 and 205334                     PAGE 47 of 95     Rev. 0
SYSTEM NITROGEN (NT)
DRAWING NO.
205301 and 205334 PAGE 47 of 95 Rev. 0
(/)
(/)
(/)
(/)                  ril                                       8 ril 8
ril 8
ril
:r:
:r:
u ril c:i..
ril z
z
8 u
                          .:i:
c:i..  
zH                  z       :><        r::i::     z         ~
~
VALVE                         VALVE        H       8         0           0                     8                   REMARKS
.:i:
                                                                                            ~     rr.. (/)
z r::i::
                                                                              ~~
z VALVE z
                                                ~
VALVE H
8 NUMBER        [/)
8 0
fil   CATEGORY               ril       .:i:                   H     ril ril     (NOT TO BE USED FOR RELIEF BASIS)
0  
[/)                           ril     :>                                ::::>  H::::;
~
                                                                    ~~
8 REMARKS H
8 j       8                             ~
~
N                                      [/) ()j   ,.:i Ol H                   u :>< 00 CJ     u                     Ul                 .:i: 8   z c:i.. ~~        ~~
8
A B c D E 2NT25         2       Gl     x           0 .*75   DA         A         c       1,3       YES       <10 sec. Ph. "A" Cont. Isol.
~~
rr.. (/)
(NOT TO BE NUMBER
[/)
fil CATEGORY ril  
.:i:
H ril ril USED FOR RELIEF BASIS)
[/)
ril  
~~
8 H::::;
j 8
N
~
[/) ()j  
,.:i Ol H
u :><
00  
~~ ~~
CJ u
Ul  
.:i: 8 z c:i..
A B c D
E 2NT25 2
Gl x
0.*75 DA A
c 1,3 YES  
<10 sec. Ph. "A" Cont. Isol.
4
/
/
4                    (Print #205301, RC System) 2NT26         2       G2     x   x     0.75     CK         SA       c       1,6       YES       (Print #205301, RC System) 2NT32         2       G3     x             1       GL         A         c       1,3       YES       <10 Sec. Ph. "A" Cont. Isol.
(Print #205301, RC System) 2NT26 2
4                   (Print #205334, SJ System)
G2 x
x 0.75 CK SA c
1,6 YES (Print #205301, RC System) 2NT32 2
G3 x
1 GL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 (Print #205334, SJ System)  


VALVE: 2NT25 CATEGORY: A CLASS: 3
VALVE:
~ FUNCTION: Containment Isolation of Nitrogen Supply to Pressurize Relief Tank.
2NT25 CATEGORY:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
A CLASS:
BASIS FOR RELIEF: Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
3  
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
~
VALVE: 2NT32 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation of Nitrogen Supply to the Safety Injection Accumulators.
FUNCTION:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
Containment Isolation of Nitrogen Supply to Pressurize Relief Tank.
BASIS FOR RELIEF: Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technjcal Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
TEST REQUIREMENTS:
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.1.2.d.
Leak Rate Testing less than each 24 months.
VALVE: 2NT26 CATEGORY: A/C (Check) e CLASS: 2 FUNCTION: Containment Isolation of Nitrogen Supply to the Pressurizer Relief Tank.
BASIS FOR RELIEF:
TEST REQUIREMENTS: Verify valve operability every three months; Leak Rate Testing less than each 24 months.
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
BASIS FOR RELIEF: This valve has no position indication and is located inside the containment.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2NT32 CATEGORY:
A CLASS:
2 FUNCTION:
Containment Isolation of Nitrogen Supply to the Safety Injection Accumulators.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technjcal Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2NT26 CATEGORY:
A/C (Check) e CLASS:
2 FUNCTION:
Containment Isolation of Nitrogen Supply to the Pressurizer Relief Tank.
TEST REQUIREMENTS:
Verify valve operability every three months; Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
This valve has no position indication and is located inside the containment.
This valve can only be verified shut during Refueling.
This valve can only be verified shut during Refueling.
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
ALTERNATE TESTING: a) Valve operability will be verified per Section XI during Leak Rate *Test at Refueling.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
b) Leak Rate Test per Technical Specification 4.6.1.2.d.
ALTERNATE TESTING:
Page 48 of 95                             Rev. 0
a)
Valve operability will be verified per Section XI during Leak Rate *Test at Refueling.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 48 of 95 Rev. 0  


SYSTEM   REACTOR COOLANT/PRESSURIZER   (RC, PR, PS)         DRAWING NO.           205301
SYSTEM REACTOR COOLANT/PRESSURIZER (RC, PR, PS)
                                                                              ~~~~~~~~~~~~
DRAWING NO. ~~~~~~~~~~~~
PAGE   49 of 95   Rev. 0 Cl)
205301 PAGE 49 of 95 Rev. 0 Cl)
Cl)                       &#xb5;:i                                         E-<
Cl)  
                    &#xb5;:i                       :r:       &#xb5;:i                               z E-<                       u         ii.
&#xb5;:i E-<  
                    .:i:
&#xb5;:i
:z                         z        ><      ~               :z       ~
:r:  
VALVE.                       VALVE                     E-<     0               0                 E-<                 REMARKS
&#xb5;:i z
                                                                                            ~
E-<
H
u ii.  
                                                                                ~~
~
H                        ~
.:i:
E-<                           Ii<  Cl)
z  
NUMBER      Cl)
~
                    @        CATEGORY                  &#xb5;:i      .:i:                      H    &#xb5;:i &#xb5;:i    (NOT TO BE USED FOR RELIEF BASIS)
:z VALVE.
Cl)                            &#xb5;:i        ::>      ;:J &#xb5;:i              E-< ;:J  H ;:J
:z VALVE H
:su  8 u
E-<
N H
0 0  
~
E-<
REMARKS H  
~
E-<  
~~
Ii<
Cl)
Cl)
                                                          ~
NUMBER Cl)
CATEGORY
&#xb5;:i
.:i:
H
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
Cl)
&#xb5;:i
;:J &#xb5;:i E-< ;:J H
;:J
:s 8
N
~
E-< ii.
E-< ii.
Cl) QI
..:l QI H
u ><
u ><
                                                                  .:i: E-<
00
                                                                            '  00
~~ ~~
u u
Cl)
.:i: E-<
:z ii.
:z ii.
Cl)
A B c D
                                                                                        ~~
E 2PR1 1
QI  ..:l QI
B2 x
                                                                                                  ~~
3 PL A
A B c D   E 2PR1     1     B2           x           3         PL       A           c         3     NO 2PR2     1     B2           x           3         PL       A           c         3     NO 2PR3     1     C2             x         6         REL       SA           c         5     NO 2PR4     1     C2             x         6         REL       SA           c         5     NO 2PR5     1     C2             x         6         REL       SA           c         5     NO 2PR6     1     B2           x           3         GA       MO           0         3     NO 2PR7     1     B2           x           3         GA       MO           0         3     NO 2PR15     2     G6           x           0.75       DIA       A           c         2     NO 2PR17     2     G2       x             0.38       PL       A           AUTO     1,3     YES       <10 Sec. Ph. "A" Cont. Isol.
c 3
4 2PR18     2     Gl       x             0.38       PL       A           AUTO     1,3     YES       <10 Sec. Ph. "A" Cont. Isol.
NO 2PR2 1
4 2PR25     2     G2             x         4         CK       SA           c         6     NO 2PR47     1     C2           x           3         PL       SOL         c         3     NO 2PR48     1     C2           x           3         PL       SOL         c         3     NO 2PS2     1     B3                   x 0.75       GL       M           L.TH.     7     NO 2PS4     1     B3                   x 0.75       GL       M           L.TH.     7     NO
B2 x
3 PL A
c 3
NO 2PR3 1
C2 x
6 REL SA c
5 NO 2PR4 1
C2 x
6 REL SA c
5 NO 2PR5 1
C2 x
6 REL SA c
5 NO 2PR6 1
B2 x
3 GA MO 0
3 NO 2PR7 1
B2 x
3 GA MO 0
3 NO 2PR15 2
G6 x
0.75 DIA A
c 2
NO 2PR17 2
G2 x
0.38 PL A
AUTO 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2PR18 2
Gl x
0.38 PL A
AUTO 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2PR25 2
G2 x
4 CK SA c
6 NO 2PR47 1
C2 x
3 PL SOL c
3 NO 2PR48 1
C2 x
3 PL SOL c
3 NO 2PS2 1
B3 x 0.75 GL M
L.TH.
7 NO 2PS4 1
B3 x 0.75 GL M
L.TH.
7 NO  


VALVE: 2 PRl 7 and 2 PR18 CATEGORY:   A CLASS: 2
VALVE:
~ FUNCTION:   Containment Isolation Pressurizer Relief Tank to Gas Analyzer Sample Line.
2 PRl 7 and 2 PR18 CATEGORY:
TEST REQUIREMENTS:     Because the safety related function of these valves is containment isolation, they will be leak tested in accordance with Techn~cal Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section Xi for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING:     Leak Rate Test per Technical Specification 4.6.1.2.d.
2  
Page 50 of 95                             Rev. 0
~
FUNCTION:
Containment Isolation Pressurizer Relief Tank to Gas Analyzer Sample Line.
TEST REQUIREMENTS:
Because the safety related function of these valves is containment isolation, they will be leak tested in accordance with Techn~cal Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section Xi for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 50 of 95 Rev. 0  


RESIDUAL HEAT REMOVAL   (RHR)                                       20S332                       PAGE Sl of 9S   Rev. 0 Ul Ul                     ~                                   8
RESIDUAL HEAT REMOVAL (RHR) 20S332 PAGE Sl of 9S Rev. 0 Ul Ul  
                      ~                     :r:     ~                           z 8                     u         11<
~
                      ~
8  
z                     z        ><  p.::           z       ~
~
VALVE                           VALVE                8   0             0                 8               REMARKS
:r:  
                                                                                  ~
~
H 8
z 8
                                                                        ~~
u 11<  
H                    ~
~
Ji.. Ul Nl'MBER         Ul
~
                      ~       CATEGORY               ~   ~                     H   ~     ~   (NOT TO BE USED FOR RELIEF BASIS)
z p.::
Ul                           ~       >    ;:J ~             8   ;:J H     ;:J j
z VALVE z
                                                      ~
VALVE H
8                           ...:l Ol u
8 0
8u                    N H
0  
Ul u ><
~
                                                            ~
8 REMARKS H
11<
~
8  
~~
Ji.. Ul Nl'MBER Ul  
~
CATEGORY  
~  
~
H  
~ ~
(NOT TO BE USED FOR RELIEF BASIS)
Ul  
~  
;:J ~
8  
;:J H  
;:J j
8 N
~
8 11<
Ul Ol
...:l Ol H
u ><
00
~~ ~~
u u
Ul
~ 8 z 11<
A B c D
E 2RH1 1
DB x
14 GA MO c
3 YES 2RH2 1
D7 x
14 GA MO c
3 YES 2RH3 2
D7 x
3 REL SA c
s NO 21RH4 2
El x
14 GA MO 0
3 NO 22RH4 2
Cl x
14 GA MO 0
3 NO 21RHB 2
E2 x
8 CK SA c
6 YES 22RHB 2
B3 x
8 CK.
SA c
6 YES 21RH12 2
D4 x
8 GA M
LC 7
NO 22RH12 2
B4 x
8 GA M
LC 7
NO 21RH18 2
ES x
8 BFY A
TH 3,4 NO 22RH18 2
BS x
8 BFY A
TH 3,4 NO 21RH19 2
DS x
8 GA MO 0
3 NO 22RH19 2
D6 x
8 GA MO 0
3 NO 2RH20 2
DS x
8 BFY A
c 3,4 NO 2RH2S 2
F7 x
0.7S REL SA c
s NO 2RH26 1
F7 x
12 GA MO c
3 YES 23RH27 1
.F7 x
8 CK SA c
6 YES 24RH27 1
F7 x
8 CK SA c
6 YES 21RH29 2
F3
}
2 GL MO AUTO 3
NO 22RH29 2
B3
}
2 GL MO AUTO 3
NO 21RH36 2
El x
0.7S GL M
LO 7
NO 22RH36 2
Cl x 0.7S GL M
LO 7
NO
 
SYSTEM.~~-RE_S_I_D_U_AL~_H_E_A_T~RE~M_O_V_AL~__.;.(_RR_R-'-)~~~~~~~
20S332 PAGE S2 of 9S Rev. 0 Ul Ul
&#xb5;:i 8
&#xb5;:i
:r::
&#xb5;:i z
8 u
: 0.
~
-=i:
z IZ z
VALVE z
VALVE H
8 0
0
&l 8
REMARKS H
8
~E rr.. Ul NllMBER Cf)
~
CATEGORY
~
-=i:
H
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
Ul
&#xb5;:i
~ ~
8
8
                                                                    '  00 z 11<
:::i Hp
Ul Ol
:s 8
                                                                                ~~      ~~
N
A  B  c D E 2RH1        1      DB            x        14      GA    MO          c        3      YES 2RH2        1      D7            x        14      GA    MO          c        3      YES 2RH3        2      D7              x      3        REL  SA          c        s      NO 21RH4        2      El            x        14      GA    MO          0        3      NO 22RH4        2      Cl            x        14      GA    MO          0        3      NO 21RHB        2      E2              x      8        CK    SA          c        6      YES 22RHB        2      B3              x      8        CK. SA          c        6      YES 21RH12      2      D4                  x  8        GA    M          LC      7      NO 22RH12      2      B4                  x  8        GA    M          LC      7      NO 21RH18      2      ES            x        8        BFY  A          TH      3,4    NO 22RH18      2      BS            x        8        BFY  A          TH      3,4    NO 21RH19      2      DS            x        8        GA    MO          0        3    NO 22RH19      2      D6            x        8        GA    MO          0        3      NO 2RH20        2      DS            x        8        BFY  A          c      3,4    NO 2RH2S        2      F7              x    0.7S      REL  SA          c        s      NO 2RH26        1      F7            x        12      GA    MO          c        3    YES 23RH27        1    .F7              x      8        CK    SA          c        6    YES 24RH27        1      F7              x      8        CK    SA          c        6    YES 21RH29        2      F3            }        2        GL    MO        AUTO        3    NO 22RH29        2      B3            }        2        GL    MO        AUTO        3    NO 21RH36        2      El                  x 0.7S      GL    M          LO        7    NO 22RH36        2      Cl                  x 0.7S      GL    M            LO      7    NO
~
 
I Cf) QI
SYSTEM.~~-RE_S_I_D_U_AL~_H_E_A_T~RE~M_O_V_AL~__.;.(_RR_R-'-)~~~~~~~                      20S332                      PAGE  S2 of 9S    Rev. 0 Ul Ul                              &#xb5;:i                                8
,_:i QI H
                            &#xb5;:i 8
:r::
u
                                                                      &#xb5;:i 0.
z
                            -=i:
z                              z        ><  IZ          z        ~
VALVE                                VALVE              H        8   0          0                  8                REMARKS
                                                            ........                            &l    rr..
                                                                                      ~E H                                              8                              Ul NllMBER                  ~          CATEGORY                          -=i:                                (NOT TO BE USED FOR RELIEF BASIS)
                                                                      ~
Cf)                                                                         H    &#xb5;:i  &#xb5;:i
                                                                            ~ ~
Ul                                      &#xb5;:i                            8  :::i Hp
:su    8u                              H N
Cf)
                                                                      ~
u ><
u ><
                                                                            -=i: 8 I
00
00 z 0.
~~ ~~
Cf)
u u
                                                                                            ~~
Cf)
QI    ,_:i QI
-=i: 8 z 0.
                                                                                                      ~~
A B c D
A   B c   D   E 21RR37         2       E4                       x   0.7S       GL   M         LO       7       NO 22RR37         2       B4                       x   0.7S       GL   M         LO       7       NO 21RR38         2       E3                       x   0.7S       GL   M         LO       7       NO 22RR38         2       B4                       x   0.7S       GL   M         LO       7       NO 21RR39         2       E4                       x   0.7S       GL   M         LO       7       NO 22RR39         2       B4                       x   0.7S       GL   M         LO       7       NO 21RR40         2       DS                       x   0.7S       GL   M         LO       7       NO 22RR40         2       DS                       x   0.7S       GL   M         LO       7       NO 2RR41         2       D6                       x   0.7S       GL   M         LO       7       NO 2RR42         2       D7                         x 0.7S       GL   M         LO       7       NO 2RR43         2       D8                         x 0.7S       GL   M         LO       7       NO 21RR10         2       E4                         x   8       GA   M         LO       7       NO 22RR10         2       B4                         x   8       GA   M         LO       7       NO 21RR14         2       ES                         x   8       GA   M         LO       7       NO 22RR14         2       BS                         x   8       GA   M         LO       7     NO 2RR21         2       D7                         x   8       GA   M         LC       7     NO
E 21RR37 2
E4 x
0.7S GL M
LO 7
NO 22RR37 2
B4 x
0.7S GL M
LO 7
NO 21RR38 2
E3 x
0.7S GL M
LO 7
NO 22RR38 2
B4 x
0.7S GL M
LO 7
NO 21RR39 2
E4 x
0.7S GL M
LO 7
NO 22RR39 2
B4 x
0.7S GL M
LO 7
NO 21RR40 2
DS x
0.7S GL M
LO 7
NO 22RR40 2
DS x
0.7S GL M
LO 7
NO 2RR41 2
D6 x
0.7S GL M
LO 7
NO 2RR42 2
D7 x
0.7S GL M
LO 7
NO 2RR43 2
D8 x
0.7S GL M
LO 7
NO 21RR10 2
E4 x
8 GA M
LO 7
NO 22RR10 2
B4 x
8 GA M
LO 7
NO 21RR14 2
ES x
8 GA M
LO 7
NO 22RR14 2
BS x
8 GA M
LO 7
NO 2RR21 2
D7 x
8 GA M
LC 7
NO  


VALVE: 2RH1 and 2RH2 CATEGORY: B CLASS: 1 FUNCTION: Residual Heat Removal pressure isolations from the Hotleg on the #21 Loop.
I I
TEST REQUIREMENTS:   Stroke Time Testing each three months.
VALVE:
BASIS FOR RELIEF:   These valves cannot be tested during Power Operati0n because they are pressure interlocked and cannot be opened with RCS > 415 psig.
2RH1 and 2RH2 CATEGORY:
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
B CLASS:
VALVE: 2RH26 CATEGORY: B CLASS: 1 FUNCTION: Residual Heat Isolation from the Hot Legs of the #23 and #24 Loops.
1 FUNCTION:
TEST REQUIREMENTS:   Stroke Time Testinq each three months.
Residual Heat Removal pressure isolations from the Hotleg on the #21 Loop.
BASIS FOR RELIEF:   This valve cannot be exercised during Power Operation because valve is shut with power removed (per Technical Specification 4.5.2) to prevent over-pressurization of the RHR System (low pressure SI System). Also, if the valve failed open, flow would be diverted from the injection flow path.
TEST REQUIREMENTS:
ALTERNATE TESTING:   This valve will be tested following Cold Shutdown and Refueling per Section XI.
Stroke Time Testing each three months.
VALVE: 23RH27 and 24RH27 CATEGORY: c (Check)
BASIS FOR RELIEF:
CLASS: 1 FUNCTION: To prevent Reactor Coolant Backflow into the Residual Heat Removal System.
These valves cannot be tested during Power Operati0n because they are pressure interlocked and cannot be opened with RCS > 415 psig.
TEST REQUIREMENTS:   This is a passive valve. During an incident LPSI is through another path, therefore exercising is not required.
ALTERNATE TESTING:
ALTERNATE TESTING:   None.
These valves will be tested during Cold Shutdown and Refueling per Section XI.
VALVE: 21RH8 and 22RHB I CATEGORY: C (Check)
VALVE:
I CLASS: 2 FUNCTION: To prevent backflow through the RHR (LPSI) pumps.
2RH26 CATEGORY:
TEST REQUIREMENTS:   Verify valve operability every three months.
B CLASS:
BASIS FOR RELIEF:   These valves can only be part stroke exersiced during Power Operation due to
1 FUNCTION:
                    *the limited size of the recirc line. To full stroke exercise these valves at Power Operation requires opening the 1RH21. Should this valve fail while open or should an incident occur while testing, too much water would be diverted from the LPSI to provide sufficie~t coolinq.
Residual Heat Isolation from the Hot Legs of the #23 and #24 Loops.
ALTERNATE TESTING:   This valve will be full stroke exercised during Cold Shutdown and Refueling per Section XI.
TEST REQUIREMENTS:
Page 53 of 95                             Rev. 0
Stroke Time Testinq each three months.
BASIS FOR RELIEF:
This valve cannot be exercised during Power Operation because valve is shut with power removed (per Technical Specification 4.5.2) to prevent over-pressurization of the RHR System (low pressure SI System).
Also, if the valve failed open, flow would be diverted from the injection flow path.
ALTERNATE TESTING:
This valve will be tested following Cold Shutdown and Refueling per Section XI.
VALVE:
23RH27 and 24RH27 CATEGORY:
c (Check)
CLASS:
1 FUNCTION:
To prevent Reactor Coolant Backflow into the Residual Heat Removal System.
TEST REQUIREMENTS:
This is a passive valve.
During an incident LPSI is through another path, therefore exercising is not required.
ALTERNATE TESTING:
None.
VALVE:
21RH8 and 22RHB CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To prevent backflow through the RHR (LPSI) pumps.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
These valves can only be part stroke exersiced during Power Operation due to  
*the limited size of the recirc line.
To full stroke exercise these valves at Power Operation requires opening the 1RH21.
Should this valve fail while open or should an incident occur while testing, too much water would be diverted from the LPSI to provide sufficie~t coolinq.
ALTERNATE TESTING:
This valve will be full stroke exercised during Cold Shutdown and Refueling per Section XI.
Page 53 of 95 Rev. 0  


SYSTEM~~S_AF
SYSTEM~~S_AF
__E_T_Y;__I_N_J_E_C_T_I_ON ____~(S_J~).___________~~----~             DRAWING NO.         20S334                       PAGE  S4 of 9S    Rev. 0
__ E_T_Y;__I_N_J_E_C_T_I_ON ____ ~(S_J~).___ ________ ~~----~ DRAWING NO.
                                                                                                  ~--------------------~
20S334  
U)
~--------------------~ PAGE S4 of 9S Rev. 0 U)
U)                                 &#xb5;:i                                       E-t
U)  
                                &#xb5;:i                               ::r:     &#xb5;:i                               z E-t                               u         11<
&#xb5;:i E-t  
&#xb5;:i
::r:  
&#xb5;:i z
E-t u
11<  
~
i:i:
i:i:
z                                 z        >i       r::i::           z       ~
z  
VALVE                                           VALVE        H         E-t     0               0                 E-t             REMARKS H                                                   E-t                     ~    Ii<
>i r::i::
                                                                                                    ~ ~.
z VALVE z
                                                                  ~
VALVE H
U)
E-t 0
NUMBER         . U)
0  
                                &sect;                 CATEGORY                 &#xb5;:i     i:i:                     H     WW       (NOT TO BE USED FOR RELIEF BASIS) w                                                 H :::>
~
                                                                            ~
E-t REMARKS H  
U) j                                            N                  ~~                   E-l :::i
~
                                                                                                                    ,_:i OI u
E-t  
8u                                H U)        :>
~ ~.
u     ><
Ii< U)
i:i: E-t
NUMBER  
                                                                                                '  00 z 11<
. U)  
U)
&sect; CATEGORY  
                                                                                                          ~~
&#xb5;:i i:i:
()I
H WW (NOT TO BE USED FOR RELIEF BASIS)
                                                                                                                    ~~
U) w  
A     B   c D E 2SJ1           2           B2                     x         8         GA         MO           c       3       YES 2SJ2           2           B2                     x         8         GA         MO         c       3       YES 2SJ3           2           B2                         x     8         CK         SA         c       6       YES 2SJ4           2           C4                     x         4         GA         MO         c       3       YES 2SJS           2           C4                     x         4         GA         MO         c       3       YES 2SJ10         2           D4                         x     0.7S       REL         SA         c       s       NO 2SJ12         1           cs                     x         4         GA         MO         c       3       NO.
~  
2SJ13         1           cs                     x         4         GA         MO         c       3       NO 21SJ16         1           B6                             x l.S       GL         M           L.TH. 7       NO 22SJ16         1           B6                             x l.S       GL         M           L.TH. 7       NO 23SJ16         1           B6                             x l.S       GL         M           L.TH. 7       NO 24SJ16         1           B6                             x l.S       GL         M           L.TH. 7       NO 21SJ17         1           B7                         x     l.S       CK           SA         c       6       YES 22SJ17         1           B7                         x     l.S       CK           SA         c       6       YES 23SJ17         1           B7                         x     l.S       CK           SA         c       6       YES 24SJ17       1             B7                         x     l.S       CK           SA         c       6       YES 21SJ29         3           F6                         x     1         SAF         SA         c       s       NO 22SJ29         3           F7                         x     1         SAF         SA         c       s       NO 23SJ29         3             FB                         x     1         SAF         SA         c       s       NO 24SJ29       3             F9                         x       1       SAF           SA       c       s       NO 2SJ30         2             Fl                     :x         8       GA           MO         0       3       YES 2SJ31         2             Fl                         x       8       CK           SA       c       6       YES
~~
E-l :::i H
j 8
N U) ()I
,_:i OI H
u ><
00
~~ ~~
u u
U) i:i: E-t z 11<
A B c D
E 2SJ1 2
B2 x
8 GA MO c
3 YES 2SJ2 2
B2 x
8 GA MO c
3 YES 2SJ3 2
B2 x
8 CK SA c
6 YES 2SJ4 2
C4 x
4 GA MO c
3 YES 2SJS 2
C4 x
4 GA MO c
3 YES 2SJ10 2
D4 x
0.7S REL SA c
s NO 2SJ12 1
cs x
4 GA MO c
3 NO.
2SJ13 1
cs x
4 GA MO c
3 NO 21SJ16 1
B6 x l.S GL M
L.TH.
7 NO 22SJ16 1
B6 x l.S GL M
L.TH.
7 NO 23SJ16 1
B6 x l.S GL M
L.TH.
7 NO 24SJ16 1
B6 x l.S GL M
L.TH.
7 NO 21SJ17 1
B7 x
l.S CK SA c
6 YES 22SJ17 1
B7 x
l.S CK SA c
6 YES 23SJ17 1
B7 x
l.S CK SA c
6 YES 24SJ17 1
B7 x
l.S CK SA c
6 YES 21SJ29 3
F6 x
1 SAF SA c
s NO 22SJ29 3
F7 x
1 SAF SA c
s NO 23SJ29 3
FB x
1 SAF SA c
s NO 24SJ29 3
F9 x
1 SAF SA c
s NO 2SJ30 2
Fl
:x 8
GA MO 0
3 YES 2SJ31 2
Fl x
8 CK SA c
6 YES  


SYSTEM~~S_AF~E_T_Y~I_N~J_E_C_T_I~O~N~~(S~J"'-'-)~~~~~~~~~~           DRAWING N0.~-2~0~5~3~3~4"'--~~~~~~~                 PAGE   55 of 95   Rev. 0 Cl)
SYSTEM~~S_AF~E_T_Y~I_N~J_E_C_T_I~O~N~~(S~J"'-'-)~~~~~~~~~~ DRAWING N0.~-2~0~5~3~3~4"'--~~~~~~~ PAGE 55 of 95 Rev. 0 Cl)
Cl)                       w                                           E-<
Cl) w E-<
w E-<
w
:r:
:r:
u li'.I 11<
li'.I z
z
E-<
                          ~
u 11<  
z z        >i         P::         z         ~
~
VALVE                             VALVE          H         E-<       0           0                   E-<                 REMARKS
~
                                                    ......                E-<                   ~   r:r..
z  
                                                                                  . ~~
>i P::
H                                                                                Cl)
z VALVE z
NUMBER         Cl)
VALVE H
                          &sect;         CATEGORY                   li'.I     ~
E-<
w H   li'.I w       (NOT TO BE USED FOR RELIEF BASIS)
0 0  
Cl)                               w         :>        ;:J               E-l ;:J   H     ;:J E-l 11<
~
                                                              ~
E-<
N
REMARKS H
:'.S u
E-<  
8u                        H Cl)      :>
~~
u
r:r..
                                                                          ~
Cl)
                                                                              >i E-<
NUMBER Cl)  
00 z 11<
&sect; CATEGORY li'.I  
Cll OI
~
                                                                                            ~~
H li'.I w (NOT TO BE USED FOR RELIEF BASIS)
                                                                                                      ...:! OI
Cl) w  
                                                                                                      ~~
;:J w E-l ;:J H  
A   B c   D E 2SJ32         2       F2             x         0.75       REL         SA       c       5       NO 21SJ33       2       Fl           x           6         GA           MO       0       3       NO 22SJ33       2       F2           x           6         GA           MO       0       3       NO 21SJ34       2       E2             x         4         CK           SA     c       6       YES 22SJ34       2       E3             x         4         CK           SA       c       6       YES 21SJ39       2       E4             x         0.75       REL           SA     c       5       NO 22SJ39       2       E4             x         0.75       REL         SA       c       5       NO 21SJ40       1       F4           x           4         GA           MO       c       3       NO 22SJ40       1     F3             x           4         GA           MO       c       3       NO 21SJ43       1       D6             x         6         CK           SA       c       6       YES 22SJ43       1       D7             x         6         CK           SA     c       6       YES 23SJ43       1       D8             x         6         CK           SA       c       6       YES 24SJ43       1       D9             x         6         CK           SA     c       6       YES 21SJ44       2     A6             x           14       GA           MO       c       3       YES 22SJ44       2     A6             x           14       GA           MO       c       3       YES 21SJ45       2       F3           x           8         GA           MO       c       3       YES 22SJ45       2       D2           x           8         GA           MO       c       3       YES                           -
;:J
21SJ48       2       G4             x         2         REL           SA     c       5       NO 22SJ48       2       F4             x         2         REL           SA     c       5       NO 21SJ49       1       G4           x           8         GA           MO       0       3       NO 22SJ49       1       F4           x           8         GA           MO       0       3       NO 2SJ53         1       F5         x             0.75       GL           A       c       i,3       YES       < lOSec. Ph. "A" Cont. Isol.
:'.S 8
N
~
E-l 11<.
Cll OI  
...:! OI H
u >i 00
~~ ~~
u u
Cl)
~ E-<
z 11<
A B c D
E 2SJ32 2
F2 x
0.75 REL SA c
5 NO 21SJ33 2
Fl x
6 GA MO 0
3 NO 22SJ33 2
F2 x
6 GA MO 0
3 NO 21SJ34 2
E2 x
4 CK SA c
6 YES 22SJ34 2
E3 x
4 CK SA c
6 YES 21SJ39 2
E4 x
0.75 REL SA c
5 NO 22SJ39 2
E4 x
0.75 REL SA c
5 NO 21SJ40 1
F4 x
4 GA MO c
3 NO 22SJ40 1
F3 x
4 GA MO c
3 NO 21SJ43 1
D6 x
6 CK SA c
6 YES 22SJ43 1
D7 x
6 CK SA c
6 YES 23SJ43 1
D8 x
6 CK SA c
6 YES 24SJ43 1
D9 x
6 CK SA c
6 YES 21SJ44 2
A6 x
14 GA MO c
3 YES 22SJ44 2
A6 x
14 GA MO c
3 YES 21SJ45 2
F3 x
8 GA MO c
3 YES 22SJ45 2
D2 x
8 GA MO c
3 YES 21SJ48 2
G4 x
2 REL SA c
5 NO 22SJ48 2
F4 x
2 REL SA c
5 NO 21SJ49 1
G4 x
8 GA MO 0
3 NO 22SJ49 1
F4 x
8 GA MO 0
3 NO 2SJ53 1
F5 x
0.75 GL A
c i,3 YES  
< lOSec. Ph. "A" Cont. Isol.  


e                                                     e                                                                     e SYSTEM     SAFETY INJECTION (SJ)                             DRAWING NO.           205334                       PAGE   56 of 95   ReY* 0 ti) ti)                     ri:l                                       8 ri:l 8
e e
e SYSTEM SAFETY INJECTION (SJ)
DRAWING NO.
205334 PAGE 56 of 95 ReY* 0 ti) ti) ri:l 8
ri:l
::x:
::x:
u ri:l (1,
ri:l z
8 u
(1,  
~
~
z
z
                        ~
:>t p:;
z                        z        :>t       p:;           z         ~
z VALVE z
VALVE                           VALVE        H       8         0             0                 8                     REMARKS
VALVE H
                                                                                            ~
8 0
                                                                                ~~
0  
H                      ~
~
8                          ~   ti)
8 REMARKS H
NtTMBER         (Jl
~
                        ~         CATEGORY               ri:l     ~                       H   ri:l ri:l     (NOT TO BE USED FOR RELIEF BASIS)
8
(Jl                           ri:l     :>        ;:J ri:l             8 ;:J H   ;:J
~~  
:s CJ 8
~ ti)
u N
NtTMBER (Jl  
H (Jl      ~
~
8 u
CATEGORY ri:l  
                                                                    ~
~
(1,
H ri:l ri:l (NOT TO BE USED FOR RELIEF BASIS)
:>t 8
(Jl ri:l  
                                                                              '  00 z (1, Ul OI
;:J ri:l 8  
                                                                                          ~~
;:J H  
                                                                                                ....:JOI
;:J
                                                                                                ~~
:s 8
A   B c D E 21SJ55         1     E6             x       10       CK           SA       c         6   YES 22SJ55         1     E7             x       10       CK           SA       c         6   YES 23SJ55         1     EB             x       10       CK           SA       c         6   YES 24SJ55         1     E9             x       10       CK           SA       c         6   YES 21SJ56         1     D7             x       10       CK           SA       c         6   YES 22SJ56         1     DB             x       10       CK           SA       c         6   YES 23SJ56         1     09             x       10       CK           SA       c         6   YES 24SJ56         1     010             x       10       CK           SA       c         6   YES 2SJ60         1     E4       x             0.75       GL           A       c       1,3   YES
N  
                                                                                                          -<10 Sec. Ph.
~
                                                                                                                          "A" Cont. Isol.
8 (1,
4 21SJ64         2     E2               x     0.75       CK           SA*     c         6   NO 22SJ64       2     E3               x     0.75       CK           SA       c         6   NO 2SJ67         2     Dl           x           2       GL           MO       0         3   NO 2SJ6B         2     Dl           x           2       GL           MO       0         3   NO 2SJ69         2     Gl           x           12       GA           MO       0         3   YES 2SJ70         2     Gl               x       12       CK           SA       c         6   YES 2SJ71         2     C4       x         x   1       GL           M       LC       1,2   YES 7
Ul OI  
2SJ75         2     05                   x   1       GL           M       LO         7   NO 2SJ7B         2     04           x         1       GL           A       0         2   NO 2SJ79         2     04           x         1       GL           A       0         2   NO 2SJB7         3     Bl             x       3       CK           SA       c         6   NO 21SJ93         3     F6           x         1       GL           A       c       3,4   NO
....:JOI H
u :>t 00
~~ ~~
CJ u
(Jl
~ 8 z (1, A
B c D
E 21SJ55 1
E6 x
10 CK SA c
6 YES 22SJ55 1
E7 x
10 CK SA c
6 YES 23SJ55 1
EB x
10 CK SA c
6 YES 24SJ55 1
E9 x
10 CK SA c
6 YES 21SJ56 1
D7 x
10 CK SA c
6 YES 22SJ56 1
DB x
10 CK SA c
6 YES 23SJ56 1
09 x
10 CK SA c
6 YES 24SJ56 1
010 x
10 CK SA c
6 YES 2SJ60 1
E4 x
0.75 GL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 21SJ64 2
E2 x
0.75 CK SA*
c 6
NO 22SJ64 2
E3 x
0.75 CK SA c
6 NO 2SJ67 2
Dl x
2 GL MO 0
3 NO 2SJ6B 2
Dl x
2 GL MO 0
3 NO 2SJ69 2
Gl x
12 GA MO 0
3 YES 2SJ70 2
Gl x
12 CK SA c
6 YES 2SJ71 2
C4 x
x 1
GL M
LC 1,2 YES 7
2SJ75 2
05 x
1 GL M
LO 7
NO 2SJ7B 2
04 x
1 GL A
0 2
NO 2SJ79 2
04 x
1 GL A
0 2
NO 2SJB7 3
Bl x
3 CK SA c
6 NO 21SJ93 3
F6 x
1 GL A
c 3,4 NO  


DRAWING N0.~~~20~5~3~3~4=-~~~~~~~                     PAGE 57 of 95     Rev. 0
DRAWING N0.~~~20~5~3~3~4=-~~~~~~~ PAGE 57 of 95 Rev. 0  
                                    ~
~
U)
U)
U)                   w                                       E-t w
U) w E-t w
E-t
::r:
::r:
u w
w z
11<
E-t u
z
11<  
                .::i:
~
z z     ><        ~              z       ~
.::i:
VALVE                   VALVE              E-t       0                                                       REMARKS
z  
                                                                              ~
~
H                              0                  E-t
z VALVE z
                                                                                    &#xb5;,
VALVE H
                                                                  ~~
E-t 0
H                    ~
0
E-t                                U)
~
CATEGORY           w                                       WW           (NOT TO BE USED FOR RELIEF BASIS)
E-t REMARKS H
NtTMBER*      ~                                    .::i:
~
U)                                                                H U)                       w     :::>      :::> w             E-t :::> H   :::>
E-t  
            ~
~~
&#xb5;, U)
NtTMBER*
U)  
~
CATEGORY w  
.::i:
H WW (NOT TO BE USED FOR RELIEF BASIS)
U) w
:::> w E-t :::>
H  
~
8 N
~
E-t 11<
E-t 11<
                                            ~
Ul OI  
Ul OI u
...:IOI H
8 u
N H
U)    :::>
u ><
u ><
                                                      .::i: E-t
00
                                                                '  00 z 11< ~~
~~ ~~
                                                                                    ...:IOI
u u
                                                                                    ~~
U)
A B c D E 22SJ93   3   F7       x         1     GL           A         c     3,4       NO 23SJ93   3   FB       x         1     GL           A         c     3,4       NO 24SJ93   3   pg       x         1     GL           A         c     3,4       NO 2SJ10B   2   B4       x         1     GL           A         0     3,4       NO 21SJ113   2   Dl       x         4     GA           MO         c       3       NO 22SJ113   2   Dl       x         4     GA           MO         c       3       NO 2SJ114   2   D2               x 6     DIA         M         LO       7       NO 21SJ116   2   E2               x 0.75   GL           M         LO       7       NO 22SJ116   2   C2               x 0.75   GL           M         LO       7       NO 2SJ123   1   FS     x           0.75   GL           A         c     1,3       YES       <10 Sec. Ph. "A" Cont. Isol 4
.::i: E-t z 11<
21SJ126   3   A6               x 0.75   GL           M         LO       7       NO 22SJ126   3   AS               x 0.75   GL           M         LO       7       NO 21SJ134   2   F4       x         4     GA           MO       0       3       NO 22SJ134   2   F4       x         4     GA           MO       0       3       NO 2SJ135   1   F4       x         4     GA           MO       0       3       YES 21SJ13B   1   GB               x 2     GL           M         L.TH. 7       NO 22SJ13B   1   GB               x 2     GL           M         L.TH. 7       NO 23SJ13B   1   G7               x 2     GL           M         L.TH. 7       NO 24SJ13B   1   G6               x 2     GL           M         L.TH. 7       NO 21SJ139   1   FB           x       2     CK             SA       c       6       YES 22SJ139   1   FB           x       2     CK             SA       c       6       YES
A B c D
E 22SJ93 3
F7 x
1 GL A
c 3,4 NO 23SJ93 3
FB x
1 GL A
c 3,4 NO 24SJ93 3
pg x
1 GL A
c 3,4 NO 2SJ10B 2
B4 x
1 GL A
0 3,4 NO 21SJ113 2
Dl x
4 GA MO c
3 NO 22SJ113 2
Dl x
4 GA MO c
3 NO 2SJ114 2
D2 x
6 DIA M
LO 7
NO 21SJ116 2
E2 x 0.75 GL M
LO 7
NO 22SJ116 2
C2 x 0.75 GL M
LO 7
NO 2SJ123 1
FS x
0.75 GL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol 4
21SJ126 3
A6 x 0.75 GL M
LO 7
NO 22SJ126 3
AS x 0.75 GL M
LO 7
NO 21SJ134 2
F4 x
4 GA MO 0
3 NO 22SJ134 2
F4 x
4 GA MO 0
3 NO 2SJ135 1
F4 x
4 GA MO 0
3 YES 21SJ13B 1
GB x
2 GL M
L.TH.
7 NO 22SJ13B 1
GB x
2 GL M
L.TH.
7 NO 23SJ13B 1
G7 x
2 GL M
L.TH.
7 NO 24SJ13B 1
G6 x
2 GL M
L.TH.
7 NO 21SJ139 1
FB x
2 CK SA c
6 YES 22SJ139 1
FB x
2 CK SA c
6 YES  


SYSTEM:____S_AF                      ___:...(S_J_)'----~--~----------~
SYSTEM:__ __ S_AF
__E_T_Y__I_N_J_E_C_T_I_ON                                        DRAWING NO.           205334
__ E_T_Y __
                                                                                                ------=~::....;:..;;:..=...--~--~--~~
I_N_J_E_C_T_I_ON __ _:...(S_J_)'----~--~----------~ DRAWING NO.
PAGE 5 .8 of 95 Rev. O U)
205334  
U)                             &#xb5;:i                                           8 8
------=~::....;:..;;:..=...--~--~--~~ PAGE 5.8 of 95 Rev. O U)
                                &#xb5;:i                             ::r:
U)  
u
&#xb5;:i 8  
                                                                          &#xb5;:i p.,
&#xb5;:i
z
::r:  
                                                                                                              ~
&#xb5;:i z
                                ~
z                              z        ><      i:i::            z VALVE                                      VALVE            H        8        0                0                    8              . REMARKS
                                                                                                  ~~
H                              ~
8                                Ii<  U)
Nl1MBER          U)
                                ~            CATEGORY                    &#xb5;:i      ~                          H      &#xb5;:i  &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
U)                                          &#xb5;:i      :>        ;:::> &#xb5;:i              8  ;:::>  H ;:::>
:s
                    ~
8 u
8 u
t'J H
p.,
U)        ~
i:i::
~
~
z z
VALVE z
VALVE H
8 0
0 8
. REMARKS H
~
8
~~
Ii< U)
Nl1MBER U)
~
CATEGORY
&#xb5;:i
~
H
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
U)
&#xb5;:i
;:::> &#xb5;:i 8
H
:s 8
t'J  
~
8 p.,
8 p.,
U) QI
,_:i QI H
u ><
u ><
                                                                                    ~     8
00
                                                                                              '    00 z p.,
~~ ~~  
U)
~
                                                                                                            ~~
u U)  
QI    ,_:i QI
~ 8 z p.,
                                                                                                                      ~~
A B c D
A B   c D   E 23SJ139         1           G7                 x         2         CK         SA           c         6         YES 24SJ139         1           GG                 x           2       CK         SA           c         6         YES 21SJ143         1           EG                         x   2       GL         M           L.TH. 7         NO 22SJ143         1           E7                         x   2       GL         M           L.TH.     7       NO 23SJ143         1           EB                         x   2       GL         M           L.TH. 7         NO 24SJ143         1           E9                         x   2         GL         M           L.TH. 7         NO 21SJ144         1           EG                 x           2       CK         SA           c         6         YES 22SJ144         1           E7       /
E 23SJ139 1
x         2         CK         SA           c         6         YES                     .
G7 x
23SJ144         1           EB                 x           2       CK         SA           c         6         YES
2 CK SA c
*24SJ144         1           E9
6 YES 24SJ139 1
                                    \            x          2         CK         SA           c         6         YES 2SJ150         1           BS                 x           3       CK         SA           c         6         YES 21SJ156         1           GB                 x         6         CK         SA           c         6         YES 22SJ156         1           GB                 x         6         CK         SA           c         6         YES 23SJ156         1           GG                 x         6         CK         SA           c         6         YES 24SJ156         1           GG                 x         6         CK         SA           c         6         YES 2SJ167         2           p4*                 x         0.75       REL         SA           c         5         NO 21SJ35         2           D3                         x   4         GA         M           0         7         NO 22SJ35         2:           D5                         x   4         GA         M           0         7         NO 21SJ54         1           D7               x             10       GA         MO           0         3       YES 22SJ54         1           DB               x             10       GA         MO           0         3       YES 23SJ54         1           D9               x             10       GA         MO           0         3       YES 24SJ54         1           DlO             x             10       GA         MO           0         3         YES
GG x
2 CK SA c
6 YES 21SJ143 1
EG x
2 GL M
L.TH.
7 NO 22SJ143 1
E7 x
2 GL M
L.TH.
7 NO 23SJ143 1
EB x
2 GL M
L.TH.
7 NO 24SJ143 1
E9 x
2 GL M
L.TH.
7 NO 21SJ144 1
EG x
2 CK SA c
6 YES 22SJ144 1
E7  
/
x 2
CK SA c
6 YES 23SJ144 1
EB \\
x 2
CK SA c
6 YES  
*24SJ144 1
E9 x
2 CK SA c
6 YES 2SJ150 1
BS x
3 CK SA c
6 YES 21SJ156 1
GB x
6 CK SA c
6 YES 22SJ156 1
GB x
6 CK SA c
6 YES 23SJ156 1
GG x
6 CK SA c
6 YES 24SJ156 1
GG x
6 CK SA c
6 YES 2SJ167 2
p4*
x 0.75 REL SA c
5 NO 21SJ35 2
D3 x
4 GA M
0 7
NO 22SJ35 2:
D5 x
4 GA M
0 7
NO 21SJ54 1
D7 x
10 GA MO 0
3 YES 22SJ54 1
DB x
10 GA MO 0
3 YES 23SJ54 1
D9 x
10 GA MO 0
3 YES 24SJ54 1
DlO x
10 GA MO 0
3 YES  


VALVE:   2SJ1 and 2SJ2 CATEGORY:   B CLASS:   2 FUNCTION:   These valves isolate the Refueling Water Storage Tank from the suction of the Charging Pumps.
VALVE:
TEST REQUIREMENTS:   Stroke Time Testing each three months.
2SJ1 and 2SJ2 CATEGORY:
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation without injecting 2000 ppm boron into the RCS resulting in a Reactor Shutdown.
B CLASS:
ALTERNf.TE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
2 FUNCTION:
VALVE:   2SJ3 CATEGORY:   C (Check)
These valves isolate the Refueling Water Storage Tank from the suction of the Charging Pumps.
CALSS:   2 FUNCTION:   To prevent backflow of the Volume Control System into the Refueling water Storage Tank.
TEST REQUIREMENTS:
TEST REQUIREMENTS:   Verify valve operability every three months.
Stroke Time Testing each three months.
BASIS FOR RELIEF:   In order to test this valve lSJl or 1SJ2 must be opened. See the specific relief for opening these valves.
BASIS FOR RELIEF:
ALTERNATE TESTING:   This valve will be tested during Cold Shutdown and Refueling per Section XI.
These valves cannot be exercised during Power Operation without injecting 2000 ppm boron into the RCS resulting in a Reactor Shutdown.
VALVE:   2SJ4 and 2SJ5 CATEGORY:   B CLASS:   2 FUNCTION:   Boron Injection Tank inlet valves.
ALTERNf.TE TESTING:
TEST REQUIREMENTS:   Strok Time Testing each three months.
These valves will be tested during Cold Shutdown and Refueling per Section XI.
BASIS FOR RELIEF:   Opening these valves during Power Operation would dilute the BIT below 20,100 ppm boron; the concentration required by Technical Specification 3.5.4.1 to insure safe Plant shutdown of the reactor during an incident.
VALVE:
ALTERN~TE TESTING:   These valves will be tested durinq Cold Shutdown and Refueling per Section XI.
2SJ3 CATEGORY:
VALVE:   21 - 24SJ17   (4 Valves)
C (Check)
CATEGORY:   c (Check)
CALSS:
CLASS:   1 FUNCTION:   To prevent backflow from the RCS Cold Legs into the Safety Injection System.
2 FUNCTION:
TEST REQUIREMENTS:   Verify valve operability every three months.
To prevent backflow of the Volume Control System into the Refueling water Storage Tank.
BASIS FOR RELIEF:   a)   For Power Operation, testing would require pumping 2,000 ppm borated water into the RCS. This would render the Reactor subcritical and would also violate Technical Specification LCO 3.5.4.1.
TEST REQUIREMENTS:
b)   For Cold Shutdown, testing would ultimately require significant RCS dilution a.nd boric acid recovery operation. It would also present a possible low-temperature RCS over-pressurization and would violate Technical Specification 3.5.4.1 and certain operating procedures.
Verify valve operability every three months.
ALTERNATE TESTING:   This valve will be tested during Refuelin9 per Section XI.
BASIS FOR RELIEF:
Page 59 of 95                           Rev. 0
In order to test this valve lSJl or 1SJ2 must be opened.
See the specific relief for opening these valves.
ALTERNATE TESTING:
This valve will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
2SJ4 and 2SJ5 CATEGORY:
B CLASS:
2 FUNCTION:
Boron Injection Tank inlet valves.
TEST REQUIREMENTS:
Strok Time Testing each three months.
BASIS FOR RELIEF:
Opening these valves during Power Operation would dilute the BIT below 20,100 ppm boron; the concentration required by Technical Specification 3.5.4.1 to insure safe Plant shutdown of the reactor during an incident.
ALTERN~TE TESTING:
These valves will be tested durinq Cold Shutdown and Refueling per Section XI.
VALVE:
21 -
24SJ17 (4 Valves)
CATEGORY:
c (Check)
CLASS:
1 FUNCTION:
To prevent backflow from the RCS Cold Legs into the Safety Injection System.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
a)
For Power Operation, testing would require pumping 2,000 ppm borated water into the RCS.
This would render the Reactor subcritical and would also violate Technical Specification LCO 3.5.4.1.
b)
For Cold Shutdown, testing would ultimately require significant RCS dilution a.nd boric acid recovery operation.
It would also present a possible low-temperature RCS over-pressurization and would violate Technical Specification 3.5.4.1 and certain operating procedures.
ALTERNATE TESTING:
This valve will be tested during Refuelin9 per Section XI.
Page 59 of 95 Rev. 0  


VALVE:   2SJ30 CATEGORY:   B CLASS:   2
VALVE:
~ FUNCTION:   Isolate S.I. Pump suctions from the Refueling water Storage Tank.
2SJ30 CATEGORY:
TEST REQUIREMENTS:     Time Stroke Testing each three months.
B CLASS:
BASIS FOR RELIEF:   Stroking this valve requires isolating the suctions of both Safety Injection Pumps from the RWST. Failure of this valve would disable both ECCS trains and render the Plant in a lesser condition of safety during Power Operation.
2  
ALTERNATE TESTING:     This valve will be tested during Cold SHutdown and Refueling per Section XI.
~
VALVE:   21SJ34 and 22SJ34 CATEGORY:   C (Check)
FUNCTION:
CLASS:   2 FUNCTION:   To prevent backflow through Safety Injection Pumps.
Isolate S.I. Pump suctions from the Refueling water Storage Tank.
TEST REQUIREMENTS:     Verify valve operability every three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   Only partial stroke testing quarterly is possible due to design of the recirculation line. Flow to Loop cannot be done at Power Operation because the RCS pressure is > Safety Injection Pump Shutoff Head.
Time Stroke Testing each three months.
ALTERNATE TESTING:     These valves will be part stroke tested quarterly per Section XI.
BASIS FOR RELIEF:
Stroking this valve requires isolating the suctions of both Safety Injection Pumps from the RWST.
Failure of this valve would disable both ECCS trains and render the Plant in a lesser condition of safety during Power Operation.
ALTERNATE TESTING:
This valve will be tested during Cold SHutdown and Refueling per Section XI.
VALVE:
21SJ34 and 22SJ34 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To prevent backflow through Safety Injection Pumps.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Only partial stroke testing quarterly is possible due to design of the recirculation line.
Flow to Loop cannot be done at Power Operation because the RCS pressure is > Safety Injection Pump Shutoff Head.
ALTERNATE TESTING:
These valves will be part stroke tested quarterly per Section XI.
The method*and frequency for full stroke testinq is still under review.
The method*and frequency for full stroke testinq is still under review.
VALVE:   2SJ31 CATEGORY:   C (Check)
VALVE:
CLASS:   2 FUNCTION:   To prevent backflow into the RWST and to prevent backflow through Safety Injection Pump.
2SJ31 CATEGORY:
TEST REQUIREMENT:   Verify valve operability every three months.
C (Check)
BASIS FOR RELIEF:   Only partial stroke testing quarterly is possible due to design of the recirculation line. Flow to Loop cannot be done at Power Operation because the RCS pressure is > Safety Injection Pump Shutoff Head.
CLASS:
ALTERi~ATE TESTING:   This valve will be part stroke tested quarterly per Section XI.
2 FUNCTION:
To prevent backflow into the RWST and to prevent backflow through Safety Injection Pump.
TEST REQUIREMENT:
Verify valve operability every three months.
BASIS FOR RELIEF:
Only partial stroke testing quarterly is possible due to design of the recirculation line.
Flow to Loop cannot be done at Power Operation because the RCS pressure is > Safety Injection Pump Shutoff Head.
ALTERi~ATE TESTING:
This valve will be part stroke tested quarterly per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
VALVE:   21 - 24SJ43   (4 Valves)
VALVE:
CATEGORY:   c (Check)
21 -
CLASS:   1 FUNCTION:   To prevent backflow of water from the accumulators to the RHR Discharge Piping.
24SJ43 (4 Valves)
TEST REQUIREMENTS:     Verify valve operability every three months.
CATEGORY:
BASIS FOR RELIEF:    During Power Operation, RCS pressure is greater than RHR Pump Shutoff Head and flow cannot be established.
c (Check)
ALTERNATE TESTING:    These valves will be part stroke tested during Cold Shutdown and Refueling per Section XI.
CLASS:
1 FUNCTION:
To prevent backflow of water from the accumulators to the RHR Discharge Piping.
TEST REQUIREMENTS:
BASIS FOR RELIEF:
ALTERNATE TESTING:
Verify valve operability every three months.
During Power Operation, RCS pressure is greater than RHR Pump Shutoff Head and flow cannot be established.
These valves will be part stroke tested during Cold Shutdown and Refueling per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
Page 60 of 95                             Rev. 0
Page 60 of 95 Rev. 0  


VALVE: 21SJ44 and 22SJ44 CATEGORY: B CLASS: 3 FUNCTION: Safety Injection System Containment Sump suction valves.
VALVE:
TEST REQUIREMENTS:   Stroke time testing each three months.
21SJ44 and 22SJ44 CATEGORY:
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation because if a valve failed, containment integrity would be breached to initiate a repair to the valve and the reactor would have to be shutdown.
B CLASS:
ALTERNATE TESTING:   These valves will be tested during Cold SHutdown and Refueling per Section XI.
3 FUNCTION:
VALVE: 21 and 22SJ45 CATEGORY: B CLASS: 2 FUNCTION: Provide suction from the RHR (LPSI) pump discharge to the Safety Injection (IPSI) and Charging (HPSI) Pumps.
Safety Injection System Containment Sump suction valves.
TEST REQUIREMENTS:   Stroke time testing each three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation because the 21 and 22SJ44 must be opened to exercise these valves due to interlocks between them.
Stroke time testing each three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation because if a valve failed, containment integrity would be breached to initiate a repair to the valve and the reactor would have to be shutdown.
ALTERNATE TESTING:
These valves will be tested during Cold SHutdown and Refueling per Section XI.
VALVE:
21 and 22SJ45 CATEGORY:
B CLASS:
2 FUNCTION:
Provide suction from the RHR (LPSI) pump discharge to the Safety Injection (IPSI) and Charging (HPSI) Pumps.
TEST REQUIREMENTS:
Stroke time testing each three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation because the 21 and 22SJ44 must be opened to exercise these valves due to interlocks between them.
See relief request for 21 and 22SJ44.
See relief request for 21 and 22SJ44.
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
ALTERNATE TESTING:
VALVE: 2SJ53 CATEGORY: A CLASS: 1
These valves will be tested during Cold Shutdown and Refueling per Section XI.
~ FUNCTION: Containment Isolation for Safety Injection Test Line.
VALVE:
TEST REQUIREMENTS-   Leak Rate Testing less than each 24 months.
2SJ53 CATEGORY:
BASIS FOR RELIEF:   Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Techncial Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
1  
VALVE: 21 - 24SJ55   (4 Valves)
~
CATEGORY: C (Check)
FUNCTION:
CLASS: 1 FUNCTION: To prevent backflow from the discharge of the RHR pumps into the accumulators.
Containment Isolation for Safety Injection Test Line.
BASIS FOR RELIEF:   During Power Operation, the RCS pressure is greater than accumulator pressure.
TEST REQUIREMENTS-Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Techncial Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
21 -
24SJ55 (4 Valves)
CATEGORY:
C (Check)
CLASS:
1 FUNCTION:
To prevent backflow from the discharge of the RHR pumps into the accumulators.
BASIS FOR RELIEF:
During Power Operation, the RCS pressure is greater than accumulator pressure.
During Cold Shutdown, testing of this valve by accumulator discharge could result in low temperature over-pressurization of the RCS.
During Cold Shutdown, testing of this valve by accumulator discharge could result in low temperature over-pressurization of the RCS.
ALTERNATE TESTING:   These valves will be part stroke tested during Refueling per Section XI.
ALTERNATE TESTING:
These valves will be part stroke tested during Refueling per Section XI.
The method and frequency for full stroke testing is stil_l under review.
The method and frequency for full stroke testing is stil_l under review.
Page 61 of 95                             Rev. 0
Page 61 of 95 Rev. 0  


VALVE:   21 - 24SJ56   (4 Valves)
VALVE:
CATEGORY:   C (Check)
21 -
CLASS:   1 FUNCTION:   To prevent backflow from the RCS Cold Legs into the accumulator and RHR Pump Discharge Lines.
24SJ56 (4 Valves)
TEST REQUIREMENTS:     Verify valve operability every three months.
CATEGORY:
BASIS FOR RELIEF:     Flow cannot be established during Power Operation because the RCS pressure is greater than both the RHR Pump Shutoff Head and the accumulator pressure.
C (Check)
ALTERNATE TESTING:     These valves will be part stroke tested during Cold SHutdown and Refueling when RHR is in service, per Section XI.
CLASS:
1 FUNCTION:
To prevent backflow from the RCS Cold Legs into the accumulator and RHR Pump Discharge Lines.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Flow cannot be established during Power Operation because the RCS pressure is greater than both the RHR Pump Shutoff Head and the accumulator pressure.
ALTERNATE TESTING:
These valves will be part stroke tested during Cold SHutdown and Refueling when RHR is in service, per Section XI.
The method and frequency for full *stroke testing is still under review.
The method and frequency for full *stroke testing is still under review.
VALVE:   2SJ60 CATEGORY:   A CLASS:   1 FUNCTION:   Containment Isolation for Safety Injection Test Line.
VALVE:
TEST REQUIREMENTS:     Leak Rate Testing less than each 24 months.
2SJ60 CATEGORY:
BASIS FOR RELIEF:     Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING:     Leak Rate Test per Technical Specification 4.6.1.2.d.
1 FUNCTION:
VALVE:   2SJ69 CATEGORY:   B CLASS:   2 FUNCTION:   Provide suction to the RHR (LPSI) pumps.
Containment Isolation for Safety Injection Test Line.
TEST REQUIREMENTS:     Stroke Time Testing each three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   This is a passive valve always maintained in the open position (Technical Specification 4.5.2 requires this valve to b~ open with the power removed during Power Operation). Failure of this valve in the closed position during testing would render the RHR (LPSI) System inoperable.
Leak Rate Testing less than each 24 months.
ALTERNATE TESTING:     This valve will be tested following Cold Shutdown and Refueling per Section XI.
BASIS FOR RELIEF:
VALVE:   2SJ70 CATEGORY:   C (Check)
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
CLASS:   2 FUNCTION:   To prevent   b~ckflow from the RHR pump suction to the Refueling Water Storage Tank.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
TEST REQUIREMENTS:     Verify valve operability every three months.
ALTERNATE TESTING:
BASIS FOR RELIEF:     Only part stroke exercise is possible due to limited size of recirculation line.
Leak Rate Test per Technical Specification 4.6.1.2.d.
ALTERN1'.TE TESTING:   This valve will be part stroke_ tested quarterly per Section XI.
VALVE:
2SJ69 CATEGORY:
B CLASS:
2 FUNCTION:
Provide suction to the RHR (LPSI) pumps.
TEST REQUIREMENTS:
Stroke Time Testing each three months.
BASIS FOR RELIEF:
This is a passive valve always maintained in the open position (Technical Specification 4.5.2 requires this valve to b~ open with the power removed during Power Operation).
Failure of this valve in the closed position during testing would render the RHR (LPSI) System inoperable.
ALTERNATE TESTING:
This valve will be tested following Cold Shutdown and Refueling per Section XI.
VALVE:
2SJ70 CATEGORY:
C (Check)
CLASS:
2 FUNCTION:
To prevent b~ckflow from the RHR pump suction to the Refueling Water Storage Tank.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Only part stroke exercise is possible due to limited size of recirculation line.
ALTERN1'.TE TESTING:
This valve will be part stroke_ tested quarterly per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
Page 62 of 95                             Rev. 0
Page 62 of 95 Rev. 0  


VALVE: 2SJ23 CATEGORY: A CLASS: 1 e FUNCTION: Containment. Isolation for Safety Injection Tank Lines.
VALVE:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
2SJ23 CATEGORY:
BASIS FOR RELIEF:   Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves us_ed for containment isolation.
A CLASS:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
1 e FUNCTION:
VALVE: 2SJ135 CATEGORY: B CLASS: 1 FUNCTION: Safety Injection (IPSI) Pump Discharge to Cold Legs.
Containment. Isolation for Safety Injection Tank Lines.
TEST REQUIREMENmS:   stroke Time Testing every three months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   This valve cannot be exercised during Power Operation because if it fails shut during testing Cold Leg Injection would be isolated placing the Plant in an unsafe condition.
Leak Rate Testing less than each 24 months.
ALTERNATE TESTING:   This valve will be tested during Cold Shutdown and Refueling per Section XI.
BASIS FOR RELIEF:
VALVE: 21 - 24SJ139     (4 Valves)
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
CATEGORY: c (Check) e CLASS: 1 FUNCTION: To prevent backflow from the RCS Hot Legs. to the discharge of the Safety Injection Pumps.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves us_ed for containment isolation.
TEST REQUIREMENTS:   Verify valve operability every three months.
ALTERNATE TESTING:
BASIS FOR RELIEF:   During Power Operation, testing is not possible _since RCS pressure is greater
Leak Rate Test per Technical Specification 4.6.1.2.d.
                      .than Safety Injection Pump Shutoff Head. During Cold Shutdown, the possibility of a Low Temperature Over-Pressurization of the *RCS exists.
VALVE:
ALTERNATE TESTING:   These valves will be part stroke tested during Refueling per Section XI.
2SJ135 CATEGORY:
B CLASS:
1 FUNCTION:
Safety Injection (IPSI) Pump Discharge to Cold Legs.
TEST REQUIREMENmS:
stroke Time Testing every three months.
BASIS FOR RELIEF:
This valve cannot be exercised during Power Operation because if it fails shut during testing Cold Leg Injection would be isolated placing the Plant in an unsafe condition.
ALTERNATE TESTING:
This valve will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
21 -
24SJ139 (4 Valves)
CATEGORY:
c (Check) e CLASS:
1 FUNCTION:
To prevent backflow from the RCS Hot Legs. to the discharge of the Safety Injection Pumps.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
During Power Operation, testing is not possible _since RCS pressure is greater  
.than Safety Injection Pump Shutoff Head.
During Cold Shutdown, the possibility of a Low Temperature Over-Pressurization of the *RCS exists.
ALTERNATE TESTING:
These valves will be part stroke tested during Refueling per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
Vi\LVE: 21 - 24SJ144     (4 Valves)
Vi\\LVE:
CATEGORY: c (Check)
21 -
CLASS: 1 FUNCTION: To prevent backflow from the RCS Cold Leg to the Safety Injection Pump Discharge Lines.
24SJ144 (4 Valves)
TEST REQUIREMETNS:   Verify valve operability every three months.
CATEGORY:
BASIS FOR RELIEF:    During Power Operation testing is not possible since RCS pressure is greater than Safety Injection Pump Shutoff Head. During Cold Shutdown a low temperature over-pressurization of the RCS could occur.
c (Check)
ALTERNATE TESTING:    These valves will be part stroke tested during Refueling per Section XI.
CLASS:
1 FUNCTION:
To prevent backflow from the RCS Cold Leg to the Safety Injection Pump Discharge Lines.
TEST REQUIREMETNS:
BASIS FOR RELIEF:
ALTERNATE TESTING:
Verify valve operability every three months.
During Power Operation testing is not possible since RCS pressure is greater than Safety Injection Pump Shutoff Head.
During Cold Shutdown a low temperature over-pressurization of the RCS could occur.
These valves will be part stroke tested during Refueling per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
Page 63 of 95                             Rev. 0
Page 63 of 95 Rev. 0  


VALVE: 2SJ150 CATEGORY: c (Check)
VALVE:
CLASS: 1
2SJ150 CATEGORY:
~ FUNCTION: To prevent backflow from the RCS Cold Legs into the BIT.
c (Check)
TEST REQUIREMENTS:   Verify valve operability every three months.
CLASS:
BASIS FOR RELIEF:   a) Testing this valve during Power Operation would render the Reactor subcritical and would also violate Technical Specification LCO 3.5.4.1.
1  
b) For Modes 3 and 4, testing would also ultimately require significant RCS dilution and boric acid recovery and a low temperature over-pressur iza.tion of the RCS could occur.
~
ALTERNATE TESTING:   This valve will be tested during Cold Shutdown and Refueling per Section XI.
FUNCTION:
VALVE: 21 - 24SJ156 CATEGORY: C (Check)
To prevent backflow from the RCS Cold Legs into the BIT.
CLASS: 1 FUNCTION: To prevent backflow from the RCS Hot Legs to the Safety Injection Pump Duscharge Lines.
TEST REQUIREMENTS:
TEST REQUIREMENTS:   Verify valve operability every three months.
Verify valve operability every three months.
BASIS FOR RELIEF:   Same conditions for relief as 21 - 24SJ139;   see specific relief for those valves.
BASIS FOR RELIEF:
ALTERNATE*TESTING:   These valves will be part stroke tested during Refueling per Section XI.
a)
Testing this valve during Power Operation would render the Reactor subcritical and would also violate Technical Specification LCO 3.5.4.1.
b)
For Modes 3 and 4, testing would also ultimately require significant RCS dilution and boric acid recovery and a low temperature over-pressur iza.tion of the RCS could occur.
ALTERNATE TESTING:
This valve will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
21 -
24SJ156 CATEGORY:
C (Check)
CLASS:
1 FUNCTION:
To prevent backflow from the RCS Hot Legs to the Safety Injection Pump Duscharge Lines.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Same conditions for relief as 21 - 24SJ139; see specific relief for those valves.
ALTERNATE*TESTING:
These valves will be part stroke tested during Refueling per Section XI.
The method and frequency for full stroke testing is still under review.
The method and frequency for full stroke testing is still under review.
VALVE: 21 - 24SJ54 CATEGORY: B CLASS: 1 FUNCTION: Accumulator Outlet to the Cold Legs.
VALVE:
TEST REQUIREMENTS:   Stroke Time Testing each three months.
21 -
BASIS FOR RELIEF:   Valves cannot be exercised when the accumulators are at normal pressure and the RCS is <1000 psig to prevent a possible Low Temperature Over-pressuriza-tion of the RCS.
24SJ54 CATEGORY:
ALTERNATE TESTING:   These valves will be tested when:
B CLASS:
a) The accumulators are at normal pressure and RCS >1000 psig.
1 FUNCTION:
b) The accumulators are depressurized and the RCS is <1000 psig.
Accumulator Outlet to the Cold Legs.
Page 64 of 95                           Rev. 0
TEST REQUIREMENTS:
Stroke Time Testing each three months.
BASIS FOR RELIEF:
Valves cannot be exercised when the accumulators are at normal pressure and the RCS is <1000 psig to prevent a possible Low Temperature Over-pressuriza-tion of the RCS.
ALTERNATE TESTING:
These valves will be tested when:
a)
The accumulators are at normal pressure and RCS >1000 psig.
b)
The accumulators are depressurized and the RCS is <1000 psig.
Page 64 of 95 Rev. 0  


VALVE: 2SJ71 CATEGORY: B CLASS: 2
VALVE:
~ FUNCTION: Safety Injection System Flushing Connection.
2SJ71 CATEGORY:
TEST REQUIREMENTS: a) Valve exercising each 3 months.
B CLASS:
b) Leak Rate Testing less than each 24 months.
2  
BASIS FOR RELIEF,: a) Passive valve not required to change position to fuliill its safety function. Valve is locked shut per Technical Specification 3.6.3.1, Table
~ FUNCTION:
Safety Injection System Flushing Connection.
TEST REQUIREMENTS:
a)
Valve exercising each 3 months.
b)
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF,:
a) b)
Passive valve not required to change position to fuliill its safety function.
Valve is locked shut per Technical Specification 3.6.3.1, Table
: 3. 6-1.
: 3. 6-1.
b)  Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.*
Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.*
ALTERNATE TESTING: a) None.
ALTERNATE TESTING:
b) None.
a)
Page 65 of 95                             Rev. 0
None.
b)
None.
Page 65 of 95 Rev. 0  


DRAWING NO.           25344/240668
DRAWING NO.
                                                                      ~~~~"'--~~~~~~~~
25344/240668  
PAGE 66 of 95   Rev. 0 U)
~~~~"'--~~~~~~~~ PAGE 66 of 95 Rev. 0 U)
U)                     &#xb5;:i ll:'.l E-<
U)  
&#xb5;:i E-<
ll:'.l
::r:
::r:
u ll:'.l tl.<
ll:'.l z
zE-<
E-<
z                     z        >i         p::               z     ~
u tl.<  
VALVE                 VALVE        H
~
                                    ...... E-<         0                 0     gJ           E-<                   REMARKS H                                                                           rz..
z  
                                                                        ~*~
>i p::
E-<                                   U)
z VALVE z
NUMBER  U)
VALVE H
              ~       CATEGORY              ll:'.l      .:!!                      H    ll:'.l rLl      (NOT TO BE USED FOR RELIEF BASIS)
E-<
U)                        ll:'.l  :>          ;:J ll:'.l            8  ;:J  H      ;:J
0 0
:s CJ 8
gJ E-<
u N
REMARKS H
H U)
E-<  
                                              ~
~*~
E-< tl.<
rz..
u >i
                                                          ,ct; 8
                                                                    '    00 z  A<
U)
U)
                                                                                ~
NUMBER U)
QI   ....:i QI gJ gJ gJ A B c D E 2SS27   2   E7     x           0.38     PL             A           c       1,3, YES             <10 Sec. Ph. "A" Cont. Isol.
~
4 2SS33   2   F7     x           0.38     PL             A           c       1,3, YES             <10 Sec. Ph. "A" Cont. Isol.
CATEGORY ll:'.l H
4 2SS49   2   G7     x           0.38     PL             A           c       1,3, YES             <10 Sec. Ph. "A" Cont. Isol.
ll:'.l rLl (NOT TO BE USED FOR RELIEF BASIS)
4 2SS64   2   G7     x           0.38     PL             A           c       1,3     YES         <10 Sec. Ph. "A" Cont. Isol.
U) ll:'.l
4 21SS93 2   D7     x           0.38     GL             A           0       1,3     YES 4
;:J ll:'.l 8
22SS93 2   C7     x           0.38     GL             A           0       1,3, YES 4
;:J H
23SS93 2   B7     x           0.38     GL             A           0       1,3     YES 4
;:J
24SS93 2   A7     x           0.38     GL             A           0       1,3, YES 4
:s 8
21SS94 2   D7     x           0.50     GL             A           0       1,3, YES             <10 Sec. Ph. "A" Cont. Isol.
N
4 22SS94 2   C7     x           0.50     GL             A           0       1,3, YES
~
                                                                                                      <10 Sec. Ph. "A" Cont. Isol.
E-<
4 23SS94 2   B7     x           0.50     GL             A           0       1,3, YES
tl.<
                                                                                                      <10 Sec. Ph. "A" cont. Isol.
U) QI  
4 24SS94 2   B7     x           0.50     GL             A           0       1,3     YES
....:i QI H
                                                                                                    -<10 Sec. Ph. "A" Cont. Isol.
u >i 00
4 2SS103 2   E7     x           0.38     PL             A           c       1,3, YES             -
~ gJ gJ gJ CJ u
                                                                                                      <10 Sec. Ph. "A" Cont. Isol.
U)
4
,ct; 8 z A<
A B
c D
E 2SS27 2
E7 x
0.38 PL A
c 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2SS33 2
F7 x
0.38 PL A
c 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2SS49 2
G7 x
0.38 PL A
c 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2SS64 2
G7 x
0.38 PL A
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 21SS93 2
D7 x
0.38 GL A
0 1,3 YES 4
22SS93 2
C7 x
0.38 GL A
0 1,3, YES 4
23SS93 2
B7 x
0.38 GL A
0 1,3 YES 4
24SS93 2
A7 x
0.38 GL A
0 1,3, YES 4
21SS94 2
D7 x
0.50 GL A
0 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4 22SS94 2
C7 x
0.50 GL A
0 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4 23SS94 2
B7 x
0.50 GL A
0 1,3, YES  
<10 Sec. Ph. "A" cont. Isol.
4 24SS94 2
B7 x
0.50 GL A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2SS103 2
E7 x
0.38 PL A
c 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4  


DRAWING NO.       205344/240668                         PAGE 67 of 95     Rev. 0 U)
DRAWING NO.
Cl)                 lil                                   8 lil                 ::c       ll:l                         z 8                   u         p.,
205344/240668 PAGE 67 of 95 Rev. 0 U)
                .ci:
Cl) lil 8
z z        >t       0::         z     ~
lil
VALVE                 VALVE      H         8         0                               8                         REMARKS
::c ll:l z
                                                                          ~
8 u
0 H                                                                rr..
p.,  
                                                              . ~~
~
                                  ~
.ci:
8                              Cl)
z  
NPMB ER   Cl)
>t 0::
                &sect;!     CATEGORY               ll:l     .ci:               H     lil ll:l         (NOT TO BE USED FOR RELIEF BASIS) lil       :>
z VALVE z
                                                        ~~
VALVE H
Cl)                                                          8 :::::> H     :::::>
8 0
j   8u                  N H          ~         u >t U) Ol     ...:l Ol
0
                                                                        ~~
~
00 u                       Cl)       :>        .ci: 8   z p.,           ~~
8 REMARKS H
A B c D E 2SS104   2     F7   x           0.38     PL           A     c     1,3, YES
~
                                                                                              -<10 ~sec. Ph. "A" Cont. Isol.
8
4 2SS107   2     G7   x           0.38     PL           A     c     1,3, YES
~~
                                                                                                <10 Sec. Ph. "A" Cont. I sol.
rr..
4 2SS110   2     G7   x           0.38     PL           A     c     1,3, YES
Cl)
                                                                                                <10 Sec. Ph. "A" Cont. Isol.
NP MB ER Cl)  
4 2SS900   1     B4   x         x 0.12     NE           M     LC     1,2, YES               Print #240668 7
&sect;!
2SS901   1     B4   x         x 0.12     NE           M     LC     1,2, YES               Print #240668 7
CATEGORY ll:l  
.ci:
H lil ll:l (NOT TO BE USED FOR RELIEF BASIS)
Cl) lil  
~~
8 H
j 8
N  
~
U) Ol  
...:l Ol H
u >t 00
~~ ~~
u u
Cl)  
.ci: 8 z p.,
A B c D
E 2SS104 2
F7 x
0.38 PL A
c 1,3, YES  
<10 ~sec. Ph. "A" Cont. Isol.
4 2SS107 2
G7 x
0.38 PL A
c 1,3, YES  
<10 Sec.
Ph. "A" Cont. I sol.
4 2SS110 2
G7 x
0.38 PL A
c 1,3, YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2SS900 1
B4 x
x 0.12 NE M
LC 1,2, YES Print #240668 7
2SS901 1
B4 x
x 0.12 NE M
LC 1,2, YES Print #240668 7  


VALVE:   2SS27, 2SS33, 2SS49 and 2SS64 CATEGORY:   A CLASS:   2 e FUNCTION:   Containment Isolation Primary System Sampling System.
VALVE:
TEST REQUIREMENTS:     Leak Rate Testing less than each 24 months.
2SS27, 2SS33, 2SS49 and 2SS64 CATEGORY:
BASIS FOR RELIEF:*   Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING:     Leak Rate Test per Technical Specification 4.6.1.2.d.
2 e FUNCTION:
VALVE:   21 - 24SS94     (4 Valves)
Containment Isolation Primary System Sampling System.
CATEGORY:   A CLASS:   2 FUNCTION:   Containment Isolation for Steam   G~nerator Drain and Blowdown.
TEST REQUIREMENTS:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:   Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
BASIS FOR RELIEF:* Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
VALVE:   2SS103, 2SS104, 2SS107 and 2SS110 CATEGORY:   A e CLASS:   2 FUNCTION:   Containment Isolation Primary System Sampling System.
ALTERNATE TESTING:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
Leak Rate Test per Technical Specification 4.6.1.2.d.
BASIS FOR RELIEF:   Beacuse the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
VALVE:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
21 -
VALVE:   2SS900 and 2SS901 CATEGORY:   A/E CLASS:   1 FUNCTION:   Containment Isolation for Pressurizer Dead Weight Test.
24SS94 (4 Valves)
TEST REQUIREMENTS:   a)   Valve exercising each 3 months.
CATEGORY:
b)    Leak Rate Testing less than each 24 months.
A CLASS:
BASIS FOR RELIEF:   a)   Passive valve not required to change position to fulfill its safety function. Valve is kept locked closed per Technical Specification 3.6.3.2.d, Table 3.6-1.
2 FUNCTION:
b)   Technical Specification Table 3.6-1 exempts these valves from Leak Rate e
Containment Isolation for Steam G~nerator Drain and Blowdown.
Testing.
TEST REQUIREMENTS:
ALTERNATE TESTING:    None.
Leak Rate Testing less than each 24 months.
Page 68 of 95                             Rev. 0
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2SS103, 2SS104, 2SS107 and 2SS110 CATEGORY:
A e CLASS:
2 FUNCTION:
Containment Isolation Primary System Sampling System.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Beacuse the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2SS900 and 2SS901 CATEGORY:
A/E CLASS:
1 FUNCTION:
Containment Isolation for Pressurizer Dead Weight Test.
TEST REQUIREMENTS:
a) b)
Valve exercising each 3 months.
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
a)
Passive valve not required to change position to fulfill its safety function.
Valve is kept locked closed per Technical Specification 3.6.3.2.d, Table 3.6-1.
e ALTERNATE TESTING:
b)
Technical Specification Table 3.6-1 exempts these valves from Leak Rate Testing.
None.
Page 68 of 95 Rev. 0  


VALVE: 11 - 14SS93   (4 Valves)
I-VALVE:
CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation from Steam Generator Sampling Lines.
11 -
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
14SS93 (4 Valves)
BASIS FOR RELIEF:   Technical Specification Table 3.6-1 exempts this valve from leak rate testing.
CATEGORY:
ALTERNATE TESTING:   None.
A CLASS:
Page 69 of 95                             Rev. 0
2 FUNCTION:
Containment Isolation from Steam Generator Sampling Lines.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Technical Specification Table 3.6-1 exempts this valve from leak rate testing.
ALTERNATE TESTING:
None.
Page 69 of 95 Rev. 0  


e                                                 e                                                                 e SYSTEM     SERVICE WATER - NUC.   (SW)                     DRAWING NO.         205342
e e
                                                                          ~~~~~~~~~~~~
e SYSTEM SERVICE WATER -
PAGE  70 of 95    Rev. 0
NUC.
                                                ~
(SW)
U) ri:i zE-1 U) ri:i                      :r:  &#xb5;:i E-1                      u    p,
DRAWING NO.
                      <:i:
205342 PAGE 70 of 95 Rev. 0
z                        z    ><      0::            z          ~
~~~~~~~~~~~~  
VALVE                          VALVE        H    E-1      0              0                    E-1              REMARKS E-1                      ~   &#xb5;.,
~
                                                                            ~~
H                        ~
U)
U)
NUMBER            ~           CATEGORY                                                              (NOT TO BE USED FOR RELIEF BASIS)
U) ri:i E-1 ri:i
                                                      ~
:r:
(/)                                           <:i:                     H   &#xb5;:i   &#xb5;:i U)                             &#xb5;:i           p &#xb5;:i               E-1 :::> HO
&#xb5;:i z
                  ~
E-1 u
E-1 p,
p,
                                                      ~
~
QI u
<:i:
8 u
z 0::
N H
z VALVE z
U) u ><
VALVE H
                                                                <:i: E-1 00 z p, U)
E-1 0
                                                                                    ~~
0
                                                                                              ...:I QI
~
                                                                                              ~~
E-1 REMARKS H
B c D E 21SW2       3     A3               x     20     DCK     SA.         0         6       NO 22SW2       3     B3               x     20     DCK     SA           0         6       NO 23SW2       3     B3               x     20     DCK     SA           0         6       NO 24SW2       3     D3               x     20     DCK     SA           0         6       NO 25SW2       3     E3               x     20     DCK     SA           0         6       NO 26SW2       3     E3               x     20     DCK     SA           0         6       NO 21SW5       3     A3               x     30     DCK     SA           0         6       NO 22SW5       3     B3               x     24     DCK     SA           0         6       NO 23SW5       3     B3               x     30     DCK     SA           0         6       NO 24SW5       3     E3               x     24     DCK       SA         0         6       NO 21SW13       3     A2               x     0.75   CK       SA         0         6       NO 22SW13       3     B2               x     0.75   CK       SA         0         6       NO 23SW13       3     B2               x     0.75   CK       SA         0         6       NO 24SW13       3     02               x     0.75   CK       SA         0         6       NO 25SW13       3     E2               x     0.75   CK       SA         0         6       NO 26SW13       3     E2               x     0.75   CK       SA         0         6     NO 21SW15       3     Al           x         2     GL       A         AUTO         2     NO 22SW15       3     Bl           x         2     GL       A         AUTO         2     NO 23SW15       3     Bl           x         2     GL       A         AUTO         2     NO 24SW15       3     Dl           x         2     GL       A         AUTO         2     NO 25SW15       3     E,l           x         2     GL       A         AUTO         2     NO 26SW15       3     El           x         2     GL       A         AUTO         2     NO
~
E-1
~~  
&#xb5;.,
U)
NUMBER
(/)  
~
CATEGORY
~
<:i:
H  
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
U)  
&#xb5;:i p  
&#xb5;:i E-1 :::>
HO  
~
8 N
~
E-1 p, U) QI
...:I QI H
u ><
00
~~ ~~
u u
U)  
<:i:
E-1 z p, A
B c D
E 21SW2 3
A3 x
20 DCK SA.
0 6
NO 22SW2 3
B3 x
20 DCK SA 0
6 NO 23SW2 3
B3 x
20 DCK SA 0
6 NO 24SW2 3
D3 x
20 DCK SA 0
6 NO 25SW2 3
E3 x
20 DCK SA 0
6 NO 26SW2 3
E3 x
20 DCK SA 0
6 NO 21SW5 3
A3 x
30 DCK SA 0
6 NO 22SW5 3
B3 x
24 DCK SA 0
6 NO 23SW5 3
B3 x
30 DCK SA 0
6 NO 24SW5 3
E3 x
24 DCK SA 0
6 NO 21SW13 3
A2 x
0.75 CK SA 0
6 NO 22SW13 3
B2 x
0.75 CK SA 0
6 NO 23SW13 3
B2 x
0.75 CK SA 0
6 NO 24SW13 3
02 x
0.75 CK SA 0
6 NO 25SW13 3
E2 x
0.75 CK SA 0
6 NO 26SW13 3
E2 x
0.75 CK SA 0
6 NO 21SW15 3
Al x
2 GL A
AUTO 2
NO 22SW15 3
Bl x
2 GL A
AUTO 2
NO 23SW15 3
Bl x
2 GL A
AUTO 2
NO 24SW15 3
Dl x
2 GL A
AUTO 2
NO 25SW15 3
E,l x
2 GL A
AUTO 2
NO 26SW15 3
El x
2 GL A
AUTO 2
NO  


e                                                       e                                                               e SYSTEM     SERVICE WATER - NUC.   (SW)                           DRAWING N0.~___..:2~0~5~3~4~2:_._~~~~~~       PAGE   71 of 95   Rev. 0 Cl)
e e
Cl)                     &#xb5;:i                                     E-t
e SYSTEM SERVICE WATER -
                        &#xb5;:i E-t
NUC.
::r:
(SW)
0
DRAWING N0.~___..:2~0~5~3~4~2:_._~~~~~~ PAGE 71 of 95 Rev. 0 Cl)
                                                            &#xb5;:i p.,
Cl)  
z
&#xb5;:i E-t  
                        .:i:
&#xb5;:i
z                       z        ><        i:i::     z       ~
::r:  
VALVE                           VALVE        H         E-t       0         0                   E-t               REMARKS
&#xb5;:i z
                                                                                          ~
E-t 0
                                                                            . z~~
p.,  
H                                            E-t                      Ii.. Cl)
~
NUMBER         Cl)
.:i:
[il       CATEGORY                 &#xb5;:i
z i:i::
:;:..      .:i:               H     &#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
z VALVE z
H ::::>
VALVE H
                                                                      ~ re           E-t ::::>
E-t 0
Cl)                            &#xb5;:i
0  
                  ~
~
QI
E-t REMARKS H
                                                            ~
E-t
t'l                                            ..:I QI CJ 80                      H Cl)                  ~*~     00 p.,
~~
Cl)
Ii.. Cl)
                                                                                      ~~         ~~
NUMBER Cl)
A   B c D E 21SW17       3     B3           x         30         BFY         MO       0       3       NO 22SW17       3     D3           x         30         BFY         MO       0       3       NO 22SW20       3     B3           x         24         BFY         MO       0       3       NO 24SW20       3     E3           x         24         BFY         MO       0       3       NO 21SW21       3     G6           x         8           BFY         MO       0       3       NO 22SW21       3     G6           x         8           BFY         MO       0       3       NO 21SW22       3     G6           x         24         BFY         MO       0       3       NO 22SW22       3     G6           x       24         BFY         MO       0       3       NO 21SW23       3     G6           x       24         BFY         MO       0       3       NO 22SW23       3     G6           x       24         BFY         MO       0       3       NO 21SW24       3     A2           x       4           GA         A       AUTO     2       NO 22SW24       3     B2           x       4           GA         A       AUTO     2       NO 23SW24       3     B2           x       4           GA         A       AUTO     2       NO 24SW24       3     D2           x       4           GA         A.     AUTO     2       NO 25SW24       3     E2           x       4           GA         A       AUTO     2       NO 26SW24       3     E2           x       4           GA         A       AUTO     2       NO 2SW28         3     A4           x       3           GL         A       AUTO     2       NO 21SW34       3     G7               x     6           DCK         SA       c       6       NO 22SW34       3     G7               x     6           DCK         SA       c       6       NO 21SW36       3     G7               x     6           DCK         SA       c       6       NO 22SW36       3     G7               x     6           DCK         SA       c       6       NO 21SW38       3     F7               x     6         DCK         SA       c       6       NO
[il CATEGORY  
&#xb5;:i  
.:i:
H  
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
Cl)
&#xb5;:i
~ re E-t ::::>
H
~
8 t'l
~
Cl) QI
..:I QI H  
~*~
00  
~~ ~~
CJ 0
Cl) z p.,
A B c D
E 21SW17 3
B3 x
30 BFY MO 0
3 NO 22SW17 3
D3 x
30 BFY MO 0
3 NO 22SW20 3
B3 x
24 BFY MO 0
3 NO 24SW20 3
E3 x
24 BFY MO 0
3 NO 21SW21 3
G6 x
8 BFY MO 0
3 NO 22SW21 3
G6 x
8 BFY MO 0
3 NO 21SW22 3
G6 x
24 BFY MO 0
3 NO 22SW22 3
G6 x
24 BFY MO 0
3 NO 21SW23 3
G6 x
24 BFY MO 0
3 NO 22SW23 3
G6 x
24 BFY MO 0
3 NO 21SW24 3
A2 x
4 GA A
AUTO 2
NO 22SW24 3
B2 x
4 GA A
AUTO 2
NO 23SW24 3
B2 x
4 GA A
AUTO 2
NO 24SW24 3
D2 x
4 GA A.
AUTO 2
NO 25SW24 3
E2 x
4 GA A
AUTO 2
NO 26SW24 3
E2 x
4 GA A
AUTO 2
NO 2SW28 3
A4 x
3 GL A
AUTO 2
NO 21SW34 3
G7 x
6 DCK SA c
6 NO 22SW34 3
G7 x
6 DCK SA c
6 NO 21SW36 3
G7 x
6 DCK SA c
6 NO 22SW36 3
G7 x
6 DCK SA c
6 NO 21SW38 3
F7 x
6 DCK SA c
6 NO  


DRAWING NO.         205342
DRAWING NO.
                                                                    ~~~-=--~~~~~~~~
205342  
PAGE 72 of 95   Rev. 0
~~~-=--~~~~~~~~ PAGE 72 of 95 Rev. 0  
                                        ~
~
U)
U)
U)                   J:il                                     8 J:il 8
U)
J:il 8
J:il
::r::
::r::
u J:il A.
J:il z
z
8 u
                  .::i:
A.  
z                     z      ><        P::             z       ~
~
VALVE                     VALVE        H     8         0               0                 8               REMARKS 8                       ~   rr..
.::i:
                                                                      ~~
z P::
H                     ~
z VALVE z
VALVE H
8 0
0  
~
8 REMARKS H
~
8  
~~
rr..
U)
NP MB ER Cl)
[ii CATEGORY J:il
.::i:
H J:il J:il (NOT TO BE USED FOR RELIEF BASIS)
U)
U)
NPMB ER    Cl)
J:il
[ii    CATEGORY            J:il      .::i:                    H    J:il J:il (NOT TO BE USED FOR RELIEF BASIS)
::i J:il 8
U)                          J:il  :::-      ::i J:il             8   ::i H     ::J
::i H ::J
:s tJ 8
:s 8
tJ N
N  
H U)    ~
~
8 A.
8 A.
U) Ol
...:I Ol H
u ><
u ><
                                                        .::i: 8
00
                                                                  '    00 z A.
~~ ~~
U)
tJ tJ U)
                                                                              ~~
.::i: 8 z A.
Ol  ...:I Ol
A B c D
                                                                                      ~~
E 22SW38 3
A B c D E 22SW38   3       F7         x       6       DCK       SA           c       6     NO 21SW39   3       G7       x         6       PL       A             c     3,4     NO 22SW39   3       G7       x         6       PL       A             c     3,4     NO 23SW39   3       G7       x         6       PL       A             c     3,4     NO 21SW42   3     . G9               x 6       BFY       M             c       7     NO 22SW42   3       G9               x 6       BFY       M             c       7     NO 23SW42   3       F9               x 6       BFY       M             c       7     NO 21SW44   3       G9           x     6       DCK       SA             c       6     NO 22SW44   3       G9           x     6       DCK       SA             c       6     NO 23SW44   3       F9           x     6       DCK       SA             c       6     NO 21SW47   3       G9           x     8       DCK       SA             c       6     NO 22SW47   3       G9           x     8       DCK       SA             c       6     NO 21SW49   3       FB       x         8       PL       A           AUTO     )2       NO 22SW49   3       F9       x         8       PL       A           AUTO       2     NO 21SW51   3       F6           x     16     DCK       SA             0       6     YES 22SW51   3       C6           x     16     DCK       SA             0       6     YES 21SW52   3       E6               x 16     BFY       M             LO       7     NO 22SW52   3       E6               x 16     BFY       M             LO       7     NO 21SW53   3       E6           x     10. DCK       SA           0       6     NO 22SW53   3       D6           x     10     DCK       SA           0       6     NO 21SW57   3       F7       x         10     BFY       A             0       2     NO 22SW57   3       E7       x         10     BFY       A.           0       2     NO
F7 x
6 DCK SA c
6 NO 21SW39 3
G7 x
6 PL A
c 3,4 NO 22SW39 3
G7 x
6 PL A
c 3,4 NO 23SW39 3
G7 x
6 PL A
c 3,4 NO 21SW42 3  
. G9 x
6 BFY M
c 7
NO 22SW42 3
G9 x
6 BFY M
c 7
NO 23SW42 3
F9 x
6 BFY M  
.. c 7
NO 21SW44 3
G9 x
6 DCK SA c
6 NO 22SW44 3
G9 x
6 DCK SA c
6 NO 23SW44 3
F9 x
6 DCK SA c
6 NO 21SW47 3
G9 x
8 DCK SA c
6 NO 22SW47 3
G9 x
8 DCK SA c
6 NO 21SW49 3
FB x
8 PL A
AUTO  
) 2 NO 22SW49 3
F9 x
8 PL A
AUTO 2
NO 21SW51 3
F6 x
16 DCK SA 0
6 YES 22SW51 3
C6 x
16 DCK SA 0
6 YES 21SW52 3
E6 x
16 BFY M
LO 7
NO 22SW52 3
E6 x
16 BFY M
LO 7
NO 21SW53 3
E6 x
: 10.
DCK SA 0
6 NO 22SW53 3
D6 x
10 DCK SA 0
6 NO 21SW57 3
F7 x
10 BFY A
0 2
NO 22SW57 3
E7 x
10 BFY A.
0 2
NO  


e                                                     e                                                                     e SYSTEM     SERVICE WATER - NUC.   (SW)                       DRAWING NO.           205342                       PAGE     73 of 95 Rev. 0 Ul Ul                       &#xb5;:i
e e
                        &#xb5;:i 8
e SYSTEM SERVICE WATER -
:r:
NUC.
u
(SW)
                                                          &#xb5;:i p.,
DRAWING NO.
z8
205342 PAGE 73 of 95 Rev. 0 Ul Ul  
                        .:i:
&#xb5;:i 8  
z            VALVE z      8
&#xb5;:i
                                                          ><      0::          z          ~
:r:  
VALVE                                        H                0            0                      8                    REMARKS 8                      ~    r.r..
&#xb5;:i z
                                                                              ~~
H                        ~
Ul Nl1MBER                        CATEGORY
                        ~                                          .:i:
Ul                                    &#xb5;:i                               H    &#xb5;:i  &#xb5;:i  (NOT TO BE USED FOR RELIEF BASIS)
Ul                                    :>                                :::>        :::>
                                                                    ~~
                                                  &#xb5;:i                                  8        H
:s u
8 u
8 u
N H
p.,
Ul       ~         u ><
~
                                                                    .:i: 8
.:i:
                                                                          '  00 z p.,
z 0::
Ul Qi
z VALVE z
                                                                                        ~~
VALVE H
H Qi
8 0
                                                                                                  ~~
0
A   B   c D E 23SW57         3     E7           x         10       BFY       A         0         2       NO 24SW57         3     D7           x         10       BFY       A         0         2       NO 25SW57       3     D7           x         10       BFY       A         0         2       NO 21SW5B       2     F7           x         10       BFY       A         0       3,4       NO 22SW5B       2,.. E7           x         10       BFY       A         0       3,4       NO 23SW5B       2     E7           x         10       BFY       A         0       3,4       NO 24SW5B       2     D7           x         10       BFY       A         0       3 ,4. NO 25SW5B       2     D7           x         10       BFY       A         0       3,4       NO 21SW65       3     FB           x         10       BFY       A         AUTO*       2     NO 22SW65       3     EB           x         10       BFY       A         AUTO         2     NO 23SW65       3     EB           x         10       BFY       A         AUTO         2     NO 24SW65       3     DB           x         10       BFY       A         AUTO         2     NO 25SW65       3     DB           x         10       BFY       A         AUTO         2     NO 21SW72       2     F9           x         10       BFY       A         0       3,4       NO 22SW72       2     E9           x         10       BFY       A         0       3,4       NO 23SW72       2     E9           x         10       BFY       A         0       3,4       NO 24SW72       2     D9           x         10       BFY       A         0       3,4       NO 25SW72       2     D9           x         10       BFY       A         0       3,4       NO 21SW77       3     E9               x     10       DCK       SA         0           6     NO 22SW77       3     D9               x     10       DCK       SA         0           6     NO 21SW7B       3     E9                   x 10       BFY       M         LO         7     NO 22SW7B       3     F9                   x 10       BFY       M         LO         7     NO
~
8 REMARKS H  
~
8
~~
r.r.. Ul Nl1MBER Ul
~
CATEGORY
&#xb5;:i
.:i:
H
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
Ul  
&#xb5;:i
~~
8 H
:s 8
N
~
Ul Qi H Qi H
u ><
00
~~ ~~
u u
Ul
.:i: 8 z p.,
A B c D
E 23SW57 3
E7 x
10 BFY A
0 2
NO 24SW57 3
D7 x
10 BFY A
0 2
NO 25SW57 3
D7 x
10 BFY A
0 2
NO 21SW5B 2
F7 x
10 BFY A
0 3,4 NO 22SW5B 2,..
E7 x
10 BFY A
0 3,4 NO 23SW5B 2
E7 x
10 BFY A
0 3,4 NO 24SW5B 2
D7 x
10 BFY A
0 3,4. NO 25SW5B 2
D7 x
10 BFY A
0 3,4 NO 21SW65 3
FB x
10 BFY A
AUTO*
2 NO 22SW65 3
EB x
10 BFY A
AUTO 2
NO 23SW65 3
EB x
10 BFY A
AUTO 2
NO 24SW65 3
DB x
10 BFY A
AUTO 2
NO 25SW65 3
DB x
10 BFY A
AUTO 2
NO 21SW72 2
F9 x
10 BFY A
0 3,4 NO 22SW72 2
E9 x
10 BFY A
0 3,4 NO 23SW72 2
E9 x
10 BFY A
0 3,4 NO 24SW72 2
D9 x
10 BFY A
0 3,4 NO 25SW72 2
D9 x
10 BFY A
0 3,4 NO 21SW77 3
E9 x
10 DCK SA 0
6 NO 22SW77 3
D9 x
10 DCK SA 0
6 NO 21SW7B 3
E9 x
10 BFY M
LO 7
NO 22SW7B 3
F9 x
10 BFY M
LO 7
NO  


__c_.___(_s_w~>--------------~
SYSTEM _____
SYSTEM_____s_E_R_V_I_C_E_W_A_T_E_R___-__NU                                      DRAWING NO.           205342                   PAGE  74 of 95    Rev. 0
s_E_R_V_I_C_E_W_A_T_E_R ___ -__ NU
                                                                                              ----------------------~
__ c_. ___
en Cl)                             w w
(_s_w~>--------------~ DRAWING NO.
8
205342  
----------------------~ PAGE 74 of 95 Rev. 0 en Cl) w 8
w
::r:
::r:
u w
w z
11<
8 u
z8
11<  
                                  .::i:
~
zH                              z       >t       fl'.!         z         ~
.::i:
VALVE                                         VALVE            H       8         0             0                                   REMARKS
z  
                                                                                                                ~ &#xb5;_,
>t fl'.!
8
z VALVE z
                                                                                              . ~~
VALVE H
                                                                  ~
8 0
8                                Cl)
0  
Nl'MBER           Cl)
~
                                  ~             CATEGORY                   w         .::i:                     H w w     (NOT TO BE USED FOR RELIEF BASIS) w       :::>
8 REMARKS H
                                                                                      ~~
~
Cl)                                                                                8~     H ~
8
j                                                                                 en u
~~
8u                              N H
&#xb5;_,
en
Cl)
                                                                            ~
Nl'MBER Cl)  
u >t
~
                                                                                      .::i: 8 00 z   11< ~~
CATEGORY w  
OI ,_:i
.::i:
                                                                                                                  ~~
H w w (NOT TO BE USED FOR RELIEF BASIS)
01 A B   c D E 21SW79           3         G9                   x         24         DCK       SA         0         6     YES 22SW79           3         F9                     x       24         DCK       SA         0         6     YES 21SW92           3         C6                 x           4         GL       A         AUTO       3     NO 22SW92           3         B6                 x           4         GL       A         AUTO       3     NO 23SW92           3         B6                 x           4         GL       A         AUTO       3     NO 21SW93           3           C9               x           4         GL       A         AUTO       2     NO 22SW93           3           B9               x           4         GL       A         AUTO       2     NO 23SW93           3           B9               x           4         GL       A         AUTO       2     NO 21SW99           3           BB                   x       4         DCK       SA         0         6     NO 22SW99           3           BB                   x       4         DCK       SA         0         6     NO 23SW99           3           AB                   x       4         DCK       SA         0         6     NO_
Cl) w  
21SW102           3           C9                       x   4         PL         A         LO         7     NO 22SW102           3             B9                       x   4         PL         A         LO         7     NO 23SW102           3             B9                       x   4         PL         A         LO         7     NO 2SW103           3             C9                       x   4         DIA       M         LO         7     NO 21SW122           3             D5             x           20         BFY       A         TH       3,4     NO 22SW122           3             D5             x           20         BFY       A         TH       3,4     NO 21SW127           3             D4                       x   20         BFY       M           LO         7   NO 22SW127           3             D4                       x   20         BFY       M           LO         7   NO 21SW129           3             D5             x           1.5       GL         A       AUTO       3,4   NO 22SW129           3             E5             x           2         GL         A       AUTO       3 ,4   NO 21SW134           3             E4                       x   1.5       DIA       M         L.TH.       7     NO
~~
8~ H  
~
j 8
N  
~
en OI
,_:i 01 H
u >t 00
~~ ~~
u u
en
.::i: 8 z 11<
A B c D E 21SW79 3
G9 x
24 DCK SA 0
6 YES 22SW79 3
F9 x
24 DCK SA 0
6 YES 21SW92 3
C6 x
4 GL A
AUTO 3
NO 22SW92 3
B6 x
4 GL A
AUTO 3
NO 23SW92 3
B6 x
4 GL A
AUTO 3
NO 21SW93 3
C9 x
4 GL A
AUTO 2
NO 22SW93 3
B9 x
4 GL A
AUTO 2
NO 23SW93 3
B9 x
4 GL A
AUTO 2
NO 21SW99 3
BB x
4 DCK SA 0
6 NO 22SW99 3
BB x
4 DCK SA 0
6 NO 23SW99 3
AB x
4 DCK SA 0
6 NO_
21SW102 3
C9 x
4 PL A
LO 7
NO 22SW102 3
B9 x
4 PL A
LO 7
NO 23SW102 3
B9 x
4 PL A
LO 7
NO 2SW103 3
C9 x
4 DIA M
LO 7
NO 21SW122 3
D5 x
20 BFY A
TH 3,4 NO 22SW122 3
D5 x
20 BFY A
TH 3,4 NO 21SW127 3
D4 x
20 BFY M
LO 7
NO 22SW127 3
D4 x
20 BFY M
LO 7
NO 21SW129 3
D5 x
1.5 GL A
AUTO 3,4 NO 22SW129 3
E5 x
2 GL A
AUTO 3,4 NO 21SW134 3
E4 x
1.5 DIA M
L.TH.
7 NO  


DRAWING NO.             20S342
DRAWING NO.
                                                                ~~__;:::;..;;...:....::.....:~~~~~~~
20S342  
PAGE 7S of 9S   Rev. 0
~~__;:::;..;;...:....::.....:~~~~~~~ PAGE 7S of 9S Rev. 0
(/)
(/)
(/)
(/)                  w                                         8 w
w 8
8
w
:r:
:r:
u w
w z
ill z
8 u
                <l; z                   z       ><      ~              z       ~
ill  
VALVE                 VALVE        H       8       0             0                   8                 REMARKS
~
                                                                                ~   r... (/)
<l; z  
                                                                    ~~
~
H                  ~
z VALVE z
f:-i NPMB ER   Cl)
VALVE H
                ~     CATEGORY               w       <l;                     H   w w       (NOT TO BE USED FOR RELIEF BASIS) w       :>                                :::>      :::>
8 0
                                                      ~ ~
0  
Cl)                                                              8       H j
~
                                              ~
8 REMARKS H
N u
~
8u                    H Cl) u
f:-i
                                                      <l; 8
~~
                                                            >< '    00 z ill Ul OI
r... (/)
                                                                            ~~
NP MB ER Cl)  
i-:1 OI
~
                                                                                    ~~
CATEGORY w  
A B c D E 22SW134 3     D4             x 2         DIA     M           L.TH.     7     NO 2SW137   3     ES       x         2         GL       A           AUTO     3,4     NO 2SW142   3     E4             x 2         DIA     M           L.TH.     7     NO 21SW14S 3     FS       x         l.S       GL       A           AUTO     3,4     NO 22SW14S 3     AS       x         l.S       GL       A           AUTO     3,4     NO 21SW1SO 3     F4             x l.S       DIA     M           L.TH.     7     NO 22SW1SO 3     A4             x l.S       DIA     M           L.TH.     7     NO 21SW1S3 3     GS       x         l.S       GA       A           AUTO     3,4     NO 22SW1S3 3     cs       x         l.S       GA       A           AUTO     3,4     NO 21SW1S8 3     G4             x l.S       DIA     M           L.TH.     7     NO 22SW1S8 3     C4             x l.S       DIA     M           L.TH.     7     NO 2SW163   3     GS       x         l.S       GL       A           AUTO     3,4     NO 2SW168   3     G4             x 1         DIA     M           L.TH.     7     NO 2SW169   3     BS       x         l.S       GL       A           AUTO     3,4     NO 2SW174   3     B4             x 1         DIA     M           L.TH.     7     NO 2SW17S   3     AS       x         2         GL       A           AUTO     3,4     NO 2SW180   3     A4             x 2         DIA     M           L.TH.     7     NO 2SW18S   3     cs       x         l.S       GL       A           AUTO     3,4     NO 2SW190   3     C4             x l.S       DIA     M             L.TH     7     NO 2SW191   3     BS     x         2         GL       A           AUTO     3,4     NO 2SW196   3     B4             x l.S       DIA       M           L.TH     7     NO 2SW199   3     FS     x         l.S       GA       A           AUTO     3,4     NO
<l; H
w w (NOT TO BE USED FOR RELIEF BASIS)
Cl) w  
~ ~
8 H
j 8
N  
~
Ul OI i-:1 OI H
u ><
00
~~ ~~
u u
Cl)
<l; 8 z ill A
B c D
E 22SW134 3
D4 x
2 DIA M
L.TH.
7 NO 2SW137 3
ES x
2 GL A
AUTO 3,4 NO 2SW142 3
E4 x
2 DIA M
L.TH.
7 NO 21SW14S 3
FS x
l.S GL A
AUTO 3,4 NO 22SW14S 3
AS x
l.S GL A
AUTO 3,4 NO 21SW1SO 3
F4 x
l.S DIA M
L.TH.
7 NO 22SW1SO 3
A4 x
l.S DIA M
L.TH.
7 NO 21SW1S3 3
GS x
l.S GA A
AUTO 3,4 NO 22SW1S3 3
cs x
l.S GA A
AUTO 3,4 NO 21SW1S8 3
G4 x
l.S DIA M
L.TH.
7 NO 22SW1S8 3
C4 x
l.S DIA M
L.TH.
7 NO 2SW163 3
GS x
l.S GL A
AUTO 3,4 NO 2SW168 3
G4 x
1 DIA M
L.TH.
7 NO 2SW169 3
BS x
l.S GL A
AUTO 3,4 NO 2SW174 3
B4 x
1 DIA M
L.TH.
7 NO 2SW17S 3
AS x
2 GL A
AUTO 3,4 NO 2SW180 3
A4 x
2 DIA M
L.TH.
7 NO 2SW18S 3
cs x
l.S GL A
AUTO 3,4 NO 2SW190 3
C4 x
l.S DIA M
L.TH 7
NO 2SW191 3
BS x
2 GL A
AUTO 3,4 NO 2SW196 3
B4 x
l.S DIA M
L.TH 7
NO 2SW199 3
FS x
l.S GA A
AUTO 3,4 NO  


SYSTEM e
e e
SERVICE WATER - NUC.   (SW)                   - DRAWING NO..         205342                   PAGE 76 of 95 e
SYSTEM SERVICE WATER -
Rey. 0
NUC.
                                                ~
(SW)
DRAWING NO..
205342 PAGE 76 of 95 Rey. 0  
~
(/)
(/)
(/)
(/)                      w                                     8 w                         ::r:   w                               z 8                         u     p.,
w 8
                      .:x:
w
z           VALVE z      :><      p:;         z         ~
::r:
VALVE                                         H     8       0           0                   8               REMARKS H                                         8                     ~
w z
                                                                        . z~~
8 u
                                                ~
p.,  
~
.:x:
z p:;
z VALVE z
VALVE H
8 0
0  
~
8 REMARKS H  
~
8  
~~
Ii< (/)
Ii< (/)
NPMB ER                       CATEGORY              w                                    w w
NP MB ER
(/)
(/)
(/)  5l                       w     :>
5l CATEGORY w
ici:
ici:
                                                                ~~                 8 H
H w w (NOT TO BE USED FOR RELIEF BASIS)
::J H   ::J (NOT TO BE USED FOR RELIEF BASIS)
(/)
                ~   8                                 ~
w
N                                  (/) QI   H QI H               u :><     00 g:J ~
~~
u     u                         (/)             ici: 8     p.,             ~~
8
A   B   c D E 2SW204       3     F4                   x 1.5   DIA       M       L.TH.       7     NO 2SW205       3     FS           x         2     GL       A       AUTO     3,4     NO 2SW210       3     F4                   x 1.5   DIA       M       L.TH.       7     NO 2SW213       3     AS           x         1.5   GL       A       AUTO     3,4     NO 2SW218       3     A4                   x 1.5   DIA       M       L.TH.       7     NO 21SW223     3     F9           x         10     PL       A       AUTO       2     NO 22SW223     3     E9           x         10     PL       A       AUTO       2     NO 23SW223     3     E9           x         10     PL       A       AUTO       2     NO 24SW223     3     D9           x         10     PL       A       AUTO       2     NO 25SW223     3     D9           x         10     PL       A       AUTO       2     NO 21SW305     3     F8           x         8     PL       A       AUTO       2     NO 22SW305     3     F8           x         8     PL       A       AUTO       2     NO 21SW1       3     B2                   x 20     BFY       M       LO         7     NO 22SW1       3     B2                   x 20     BFY       M       LO         7     NO 23SW1       3     C2                   x 20     BFY       M       LO         7     NO 24SW1       3     E2   I               x 20     BFY       M       LO         7     NO 25SW1       3     E2                   x 20     BFY       M       LO         7     NO 26SW1       3     F2                   x 20     BFY       M       LO         7     NO 21SW3       3     B2                   x 20     BFY       M       LO           7     NO 22SW3       3     B2                   x 20     BFY       M       LO           7     NO 23SW3       3     C2                   x 20     BFY       M       LO           7     NO 24SW3       3     E2                   x 20     BFY       M       LO           7     NO
::J H
::J  
~
8 N
~
(/) QI H QI H
u :><
00 g:J ~ ~~
u u
(/)
ici: 8 z p.,
A B c D
E 2SW204 3
F4 x
1.5 DIA M
L.TH.
7 NO 2SW205 3
FS x
2 GL A
AUTO 3,4 NO 2SW210 3
F4 x
1.5 DIA M
L.TH.
7 NO 2SW213 3
AS x
1.5 GL A
AUTO 3,4 NO 2SW218 3
A4 x
1.5 DIA M
L.TH.
7 NO 21SW223 3
F9 x
10 PL A
AUTO 2
NO 22SW223 3
E9 x
10 PL A
AUTO 2
NO 23SW223 3
E9 x
10 PL A
AUTO 2
NO 24SW223 3
D9 x
10 PL A
AUTO 2
NO 25SW223 3
D9 x
10 PL A
AUTO 2
NO 21SW305 3
F8 x
8 PL A
AUTO 2
NO 22SW305 3
F8 x
8 PL A
AUTO 2
NO 21SW1 3
B2 x
20 BFY M
LO 7
NO 22SW1 3
B2 x
20 BFY M
LO 7
NO 23SW1 3
C2 x
20 BFY M
LO 7
NO 24SW1 3
E2 I
x 20 BFY M
LO 7
NO 25SW1 3
E2 x
20 BFY M
LO 7
NO 26SW1 3
F2 x
20 BFY M
LO 7
NO 21SW3 3
B2 x
20 BFY M
LO 7
NO 22SW3 3
B2 x
20 BFY M
LO 7
NO 23SW3 3
C2 x
20 BFY M
LO 7
NO 24SW3 3
E2 x
20 BFY M
LO 7
NO  


e                                                   e                                                             e
e e
.SYSTEM       SERVICE WATER - NUC.   (SW)                   DRAWING NO.       205342
e  
                                                                          ~~~~~~~~~~~~
.SYSTEM SERVICE WATER -
PAGE 77 of 95   Rev. 0 Ul Ul                       &#xb5;.i                                   8
NUC.
                    &#xb5;.i 8
(SW)
:r:
DRAWING NO.
u
205342  
                                                        &#xb5;.i 0.
~~~~~~~~~~~~ PAGE 77 of 95 Rev. 0 Ul Ul  
z
&#xb5;.i 8  
                    .:i:
&#xb5;.i
z         VALVE z        >i       i:r:       z       ~
:r:  
VALVE                                     H         8       0           0       gJ &#xb5;.. Ul 8                REMARKS
&#xb5;.i z
                                                                          ~~
8 u
H                      ~
: 0.  
8 NlTMBER                  CATEGORY
~
                    ~                                                                              (NOT TO BE USED FOR RELIEF BASIS)
.:i:
U)                                        &#xb5;.i     .:i:                 H   &#xb5;.i   &#xb5;.i
z  
                                                                ~~
>i i:r:
Ul                              &#xb5;.i                                 8   ::i H     ::J
z VALVE z
              ~                                         ~*
VALVE H
N                                          ....:I Ol u
8 0
8u                        H Ul        :>
0 gJ 8
u >i
REMARKS H
                                                                .:i: 8
~
                                                                        '  00 z 0.
8
Ul Ol
~~
                                                                                  ~~      gJ ~
&#xb5;.. Ul NlTMBER U)
A B   c   D E 25SW3   3       E2                   x 20         BFY       M       LO       7     NO 26SW3   3       F2                   x 20         BFY       M       LO       7     NO 21SW9   3       B2                   x 1.5       DIA       M       LO       7     NO 22SW9   3       E2                   x 1.5       DIA       M       LO       7     NO 21SW33 3       G7                   x 6         BFY       M       LO       7     NO 22SW33 3       G7                   x 6         BFY       M       LO       7     NO 21SW35 3       G7                   x 6         BFY       M       LO       7     NO 22SW35 3       G7                   x 6         BFY       M       LO       7     NO 21SW37 3       G7                   x 6         BFY       M       LO       7     NO 22SW37 3       G7                   x 6         BFY       M       LO       7     NO 21SW45 3       G9                   x 6         BFY       M       LO       7     NO 22SW45 3       G9                   x 6         BFY       M       LO       7     NO 23SW45 3       G9                   x 6         BFY       M       LO       7     NO 21SW46 3       G9                   x 6         BFY       M       LO       7     NO 22SW46 3       G9                   x 6         BFY       M       LO       7     NO 23SW46 3       G9                   x 6         BFY       M       LO       7     NO 21SW50 3       F9                   x 8         BFY       M       LO       7     NO 22SW50 3       F9                   x 8         BFY       M       LO       7     NO 21SW52 3       E6                   x 10         BFY     M         LO       7     NO 22SW52 3       E6                   x 10         BFY     M         LO       7     NO 21SW54 3       F6                   x 10         BFY       M       LO       7     NO 22SW54 3       F6                   x 10         BFY     M         LO       7     NO
~
CATEGORY  
&#xb5;.i  
.:i:
H  
&#xb5;.i &#xb5;.i (NOT TO BE USED FOR RELIEF BASIS)
Ul
&#xb5;.i  
~~
8
::i H
::J  
~
8 N
~*
Ul Ol
....:I Ol H
u >i 00
~~ gJ ~
u u
Ul
.:i: 8 z 0.
A B c D
E 25SW3 3
E2 x
20 BFY M
LO 7
NO 26SW3 3
F2 x
20 BFY M
LO 7
NO 21SW9 3
B2 x
1.5 DIA M
LO 7
NO 22SW9 3
E2 x
1.5 DIA M
LO 7
NO 21SW33 3
G7 x
6 BFY M
LO 7
NO 22SW33 3
G7 x
6 BFY M
LO 7
NO 21SW35 3
G7 x
6 BFY M
LO 7
NO 22SW35 3
G7 x
6 BFY M
LO 7
NO 21SW37 3
G7 x
6 BFY M
LO 7
NO 22SW37 3
G7 x
6 BFY M
LO 7
NO 21SW45 3
G9 x
6 BFY M
LO 7
NO 22SW45 3
G9 x
6 BFY M
LO 7
NO 23SW45 3
G9 x
6 BFY M
LO 7
NO 21SW46 3
G9 x
6 BFY M
LO 7
NO 22SW46 3
G9 x
6 BFY M
LO 7
NO 23SW46 3
G9 x
6 BFY M
LO 7
NO 21SW50 3
F9 x
8 BFY M
LO 7
NO 22SW50 3
F9 x
8 BFY M
LO 7
NO 21SW52 3
E6 x
10 BFY M
LO 7
NO 22SW52 3
E6 x
10 BFY M
LO 7
NO 21SW54 3
F6 x
10 BFY M
LO 7
NO 22SW54 3
F6 x
10 BFY M
LO 7
NO  


e                                                   e                                                             e SYSTEM     SERVICE WATER - NUC.   (SW)                     DRAWING NO.         205342                   PAGE   7B of 95     Rev. 0 U)
e e
U)                     ril                                   8 ril 8
e SYSTEM SERVICE WATER -
NUC.
(SW)
DRAWING NO.
205342 PAGE 7B of 95 Rev. 0 U)
U) ril 8
ril
::r:
::r:
u ril p.,
ril z
z VALVE
8 u
                      ~
p.,  
z         VALVE z      ><        P::       z       ~
~
H       8         0         0
~
                                                                                    ~
z P::
8                 REMARKS H
z VALVE z
                                                                          ~~
VALVE H
8                      ri. U)
8 0
Nl1MBER     Cl)
0  
                      ~         CATEGORY             ril
~
:;:..      ~                 H   ILi ILi   (NOT TO BE USED FOR RELIEF BASIS)
8 REMARKS H
U)                           ril                                   :::>      :::>
8
                                                                ~~
~~
8       H 8u                              ~
ri. U)
:'.&sect;                         N                                 U) Ol   ...:l Ol H                 u >< 00 u                           U)                 ~   8   z p., ~~      ~~
Nl1MBER Cl)  
A   B   c D E 23SW54     3     E6                 x 10       BFY       M       LO       7     NO 24SW54     3     E6                 x 10       BFY       M       LO       7     NO 25SW54     3     D6                 x 10       BFY       M       LO       7     NO 21SW60     2     FB                 x 10       BFY       M       L.TH. 7     NO 22SW60     2     FB                 x 10       BFY       M       L.TH. 7     NO 23SW60     2     EB                 x 10       BFY       M       L.TH. 7     NO 24SW60     2     EB                 x 10       BFY       M       L.TH. 7     NO 25SW60     2     DB                 x 10       BFY       M       L.TH. 7     NO 21SW66     3     FB                 x 2         DIA       M       LO       7     NO 22SW66     3     EB                 x 2         DIA       M       LO       7     NO 23SW66     3     EB                 x 2         DIA       M       LO       7     NO 24SW66     3     DB                 x 2         DIA       M       LO       7     NO 25SW66     3     DB                 x 2         DIA       M       LO       7     NO 21SW71     3       F9                 x 2         DIA       M       LO       7     NO 22SW71     3     E9                 x 2         DIA       M       LO       7     NO 23SW71     3     E9                 x 2         DIA       M       LO       7     NO 24SW71     3       D9                 x 2         DIA         M       LO       7     NO 25SW71     3       D9                 x 2         DIA         M       LO       7     NO 21SW76     3       FlO               x 10       BFY         M       LO       7     NO 22SW76     3       FlO               x 10       BFY         M       LO       7     NO 23sw76     3       ElO               x 10       BFY         M       LO       7     NO 24SW76     3       DlO               x 10       BFY         M       LO       7     NO 25SW76     3       DlO               x 10       BFY         M       LO       7     NO
~
CATEGORY ril  
~
H ILi ILi (NOT TO BE USED FOR RELIEF BASIS)
U) ril  
~~
8 H
:'.&sect; 8
N  
~
U) Ol  
...:l Ol H
u ><
00  
~~ ~~
u u
U)  
~ 8 z p.,
A B c D
E 23SW54 3
E6 x
10 BFY M
LO 7
NO 24SW54 3
E6 x
10 BFY M
LO 7
NO 25SW54 3
D6 x
10 BFY M
LO 7
NO 21SW60 2
FB x
10 BFY M
L.TH.
7 NO 22SW60 2
FB x
10 BFY M
L.TH.
7 NO 23SW60 2
EB x
10 BFY M
L.TH.
7 NO 24SW60 2
EB x
10 BFY M
L.TH.
7 NO 25SW60 2
DB x
10 BFY M
L.TH.
7 NO 21SW66 3
FB x
2 DIA M
LO 7
NO 22SW66 3
EB x
2 DIA M
LO 7
NO 23SW66 3
EB x
2 DIA M
LO 7
NO 24SW66 3
DB x
2 DIA M
LO 7
NO 25SW66 3
DB x
2 DIA M
LO 7
NO 21SW71 3
F9 x
2 DIA M
LO 7
NO 22SW71 3
E9 x
2 DIA M
LO 7
NO 23SW71 3
E9 x
2 DIA M
LO 7
NO 24SW71 3
D9 x
2 DIA M
LO 7
NO 25SW71 3
D9 x
2 DIA M
LO 7
NO 21SW76 3
FlO x
10 BFY M
LO 7
NO 22SW76 3
FlO x
10 BFY M
LO 7
NO 23sw76 3
ElO x
10 BFY M
LO 7
NO 24SW76 3
DlO x
10 BFY M
LO 7
NO 25SW76 3
DlO x
10 BFY M
LO 7
NO  


DRAWING N0.~__..2~0~5~3~4~2.___~~~~~~~         PAGE   79 of 95   Rev. 0 (I)
DRAWING N0.~__..2~0~5~3~4~2.___~~~~~~~ PAGE 79 of 95 Rev. 0 (I)
(I)                 &#xb5;:i                                       8
(I)  
                &#xb5;:i E-<
&#xb5;:i 8  
:r:
&#xb5;:i
:r:  
&#xb5;:i z
E-<
u
u
                                                &#xb5;:i 11.
: 11.  
z
~
              .:i:
.:i:
zH                    z         :><      ~           z       ~
z  
VALVE                 VALVE        H         E-<     0           0       gJ       E-<               REMARKS E-<
~
                                                                  . ~~
z VALVE z
                                    ~
VALVE H
Ii<   (I)
E-<
Nl'MBER   (I)
0 0
              &sect;     CATEGORY               . &#xb5;:i     .:i:                 H &#xb5;:i   &#xb5;:i   (NOT TO BE USED FOR RELIEF BASIS)
gJ E-<
                                                        ~~              8 ::J (I)                       &#xb5;:i                                         H     ::J j   8                   N
REMARKS H
:;1     u :><
~
(I) QI ...:I QI 00
E-<  
                                                                          ~ gJ H
~~
(.) (.)                 en         :>      .:i: E-<   z 11.         ~~
Ii< (I)
A B c D E 21SW90   3     E6             x 4         DIA         M         LO       7     NO 22SW90   3     C6             x 4         DIA         M         LO       7     NO 21SW91   3     C6             x 4         DIA         M         LO       7     NO 22SW91   3     C6             x 4         DIA         M         LO       7     NO 23SW91   3     B6             x 4         DIA         M         LO       7     NO 21SW102 3     ClO             x 4         DIA         M         LO       7     NO 22SW102 3     ClO             x 4         DIA         M         LO       7     NO 23SW102 3     BlO             x 4         DIA         M         LO       7     NO 2SW103   3     ClO             x 4         DIA         M         LO       7     NO 2SW120   3     B9             x 4         DIA         M         LO       7     NO 21SW121 3     E6             x 20         BFY         M         LO       7     NO 22SW121 3     E6             x 20         BFY         M         LO       7     NO                 /
Nl'MBER (I)  
21SW127 3     E4             x 20         BFY         M         L.TH. 7     NO 22SW127 3     E4             x 20         BFY         M         L.TH. 7     NO 21SW128 3     E6             x 1.5       DIA         M         LO       7     NO 22SW128 3     D6             x 2         DIA         M         LO       7     NO 21SW134 3     E4             x 1.5       DIA         M         L.TH. 7     NO 22SW134 3     D4             x 2         DIA         M         L.TH. 7   NO 21SW135 3     E4             x 1.5       DIA         M         LO       7   NO       "
&sect; CATEGORY  
22SW135 3     D4             x 2         DIA       *M         LO       7   NO 2SW136   3     E6             x 2         DIA         M         LO       7   NO 2SW142   3     E4             x 2         DIA         M         LO       7   NO
. &#xb5;:i  
.:i:
H  
&#xb5;:i &#xb5;:i (NOT TO BE USED FOR RELIEF BASIS)
(I)  
&#xb5;:i  
~~
8
::J H
::J j
8 N
:;1 (I) QI  
...:I QI H
u :><
00  
~ gJ  
~~
(.)
(.)
en  
.:i: E-<
z 11.
A B c D
E 21SW90 3
E6 x
4 DIA M
LO 7
NO 22SW90 3
C6 x
4 DIA M
LO 7
NO 21SW91 3
C6 x
4 DIA M
LO 7
NO 22SW91 3
C6 x
4 DIA M
LO 7
NO 23SW91 3
B6 x
4 DIA M
LO 7
NO 21SW102 3
ClO x
4 DIA M
LO 7
NO 22SW102 3
ClO x
4 DIA M
LO 7
NO 23SW102 3
BlO x
4 DIA M
LO 7
NO 2SW103 3
ClO x
4 DIA M
LO 7
NO 2SW120 3
B9 x
4 DIA M
LO 7
NO 21SW121 3
E6 x
20 BFY M
LO 7
NO 22SW121 3
E6 x
20 BFY M
LO 7
NO  
/
21SW127 3
E4 x
20 BFY M
L.TH.
7 NO 22SW127 3
E4 x
20 BFY M
L.TH.
7 NO 21SW128 3
E6 x
1.5 DIA M
LO 7
NO 22SW128 3
D6 x
2 DIA M
LO 7
NO 21SW134 3
E4 x
1.5 DIA M
L.TH.
7 NO 22SW134 3
D4 x
2 DIA M
L.TH.
7 NO 21SW135 3
E4 x
1.5 DIA M
LO 7
NO 22SW135 3
D4 x
2 DIA  
*M LO 7
NO 2SW136 3
E6 x
2 DIA M
LO 7
NO 2SW142 3
E4 x
2 DIA M
LO 7
NO  


SYSTEM;..._______S_E_R_V_I_C_E_W_A_T_E_R__-__NU
SYSTEM;..._ ______
__C_.__~(_S_W~)______________                    205342                     PAGE   80 of 95   Rev. 0
S_E_R_V_I_C_E_W_A_T_E_R __ -__ NU
                                                                      ~
__ C_. __ ~(_S_W~) ____________ __
Ul Ul                                   J:il                           8 J:il                                 ::r: J:il                     :z; 8                                     u     p.,
205342 PAGE 80 of 95 Rev. 0  
~
Ul Ul J:il 8
J:il
::r:
J:il
:z; 8
u p.,  
~
ici:
ici:
z z    :>t ll::       z       ~
z
VALVE                                           VALVE              H
:>t ll::
                                                                      ..._,  8   0           0       gJ       8                 REMARKS r...
z VALVE z
                                                                                            ~~
VALVE H
H                                                8                            Ul Nl'MBER             CJ) fi               CATEGORY                   J:il ici:                 H   J:il J:il (NOT TO BE USED FOR RELIEF BASIS)
8 0
Ul                                                   ::>
0 gJ 8
                                                                                  ~~
REMARKS H
J:il                        8   :J H :J
8
:su        8 u
~~
N H
r... Ul Nl'MBER CJ) fi CATEGORY J:il ici:
Ul    ~    u :>t ici: 8
H J:il J:il (NOT TO BE USED FOR RELIEF BASIS)
                                                                                        '  00 z p.,
Ul J:il
Ul QI
~~
                                                                                                  ~ gJ
8 :J H :J
                                                                                                          ,_:i QI gJ ~
:s 8
A   B   c     D E 2SW143           3           E4                             x   2       DIA   M       LO       7     NO 21SW144           3           F6                             x   1.5     DIA   M       LO       7     NO 22SW144           3           B6                             x   1.5     DIA   M       LO       7     NO 21SW150           3           F4                             x   1.5     DIA   M       L.TH. 7     NO 22SW150           3           B4                             x   1.5     DIA   M       L.TH. 7     NO 21SW151           3*         F4                             x   1.5     DIA   M       LO       7     NO 22SW151           3           B4                             x   1.5     DIA   M       LO       7     NO 21SW152           3           G6                             x   1.5     DIA   M       LO       7     NO 22SW152           3           D6                             x   1.5     DIA   M       LO       7     NO 21SW159       ' 3             G4                             x   1.5     DIA   M       LO       7     NO 22SW159           3           D4                             x   1.5     DIA   M       LO       7     NO 2SW160           3           B6                             x   2       DIA   M       LO       7     NO 2SW162           3           F6                             x   3       DIA   M       LO       7     NO 2SW168           3           G4                             x   1.5     DIA   M       L.TH. 7     NO 2SW174           3           C4                             x   1.5     DIA   M       L.TH. 7     NO 2SW180           3           B4                             x   2       DIA   M       L.TH. 7     NO 2SW181           3           F4                             x   3       DIA   M       LO       7     NO 2SW184           3           C6                             x   2       DIA   M       LO       7     NO 2SW197           3           C4                             x   2       DIA   M       LO       7     NO 2SW198           3           F6                           x   1.5     DIA   M       LO       7     NO 2SW211           3           F4                           x   2       DIA   M       LO       7     NO 2SW220           3           B4                           x   2       DIA   M       LO       7     NO
N  
~
Ul QI
,_:i QI H
u :>t 00
~ gJ gJ ~
u u
Ul ici: 8 z p.,
A B c D E 2SW143 3
E4 x
2 DIA M
LO 7
NO 21SW144 3
F6 x
1.5 DIA M
LO 7
NO 22SW144 3
B6 x
1.5 DIA M
LO 7
NO 21SW150 3
F4 x
1.5 DIA M
L.TH.
7 NO 22SW150 3
B4 x
1.5 DIA M
L.TH.
7 NO 21SW151 3*
F4 x
1.5 DIA M
LO 7
NO 22SW151 3
B4 x
1.5 DIA M
LO 7
NO 21SW152 3
G6 x
1.5 DIA M
LO 7
NO 22SW152 3
D6 x
1.5 DIA M
LO 7
NO 21SW159  
' 3 G4 x
1.5 DIA M
LO 7
NO 22SW159 3
D4 x
1.5 DIA M
LO 7
NO 2SW160 3
B6 x
2 DIA M
LO 7
NO 2SW162 3
F6 x
3 DIA M
LO 7
NO 2SW168 3
G4 x
1.5 DIA M
L.TH.
7 NO 2SW174 3
C4 x
1.5 DIA M
L.TH.
7 NO 2SW180 3
B4 x
2 DIA M
L.TH.
7 NO 2SW181 3
F4 x
3 DIA M
LO 7
NO 2SW184 3
C6 x
2 DIA M
LO 7
NO 2SW197 3
C4 x
2 DIA M
LO 7
NO 2SW198 3
F6 x
1.5 DIA M
LO 7
NO 2SW211 3
F4 x
2 DIA M
LO 7
NO 2SW220 3
B4 x
2 DIA M
LO 7
NO  


SYSTEM____~S~E~R~V~I~C~E~W~A~T~E~R'----N~U~C~.--~(S~W~)'--------------~     DRAWING NO. 205342                       PAGE  81 of 95    Rev. 0
SYSTEM ____ ~S~E~R~V~I~C~E~W~A~T~E~R'----N~U~C~.--~(S~W~)'--------------~ DRAWING NO.
                                                                                        ----------------------~               ---------------------
205342  
CJ)
----------------------~
CJ)                                 &#xb5;:i                                 8 lil 8
PAGE 81 of 95 Rev. 0 CJ)
:r:
CJ)  
u
&#xb5;:i 8
                                                                        &#xb5;:i p..
lil
z
:r:  
                            .:i:
&#xb5;:i z
z                                   z       :><      ~          z       ~
8 u
VALVE                                   VALVE                H       8       0         0                 8               REMARKS H                                 .._,              8                   ~   rr..
p..  
                                                                                      . ~~
~
.:i:
z  
~
z VALVE z
VALVE H
8 0
0  
~
8 REMARKS H
8  
~~
rr..
CJ)
CJ)
NUMBER                                 CATEGORY                                                                (NOT TO BE USED FOR RELIEF BASIS) 5l                                                   ~~:><
NUMBER CJ) 5l CATEGORY
CJ)                                                  &#xb5;:i                         H   lil lil CJ)                                         &#xb5;:i     !>                      E-1 ::::> H ::::>
&#xb5;:i  
                  ~       8u                                          ~
~~
N                                CJ) QI   ,_:i QI H               u       00 u                                           CJ)             ~ E-1   z p.. ~~        ~~
H lil lil (NOT TO BE USED FOR RELIEF BASIS)
A   B   c   D   E 2SW308         3         Bl             x               8       PL       A       AUTO       3     NO 2SW311         3         Gl             x               8       PL       A       AUTO       3     NO
CJ)  
&#xb5;:i E-1 H  
~
8 N
~
CJ) QI  
,_:i QI H
u :><
00  
~~ ~~
u u
CJ)  
~ E-1 z p..
A B c D
E 2SW308 3
Bl x
8 PL A
AUTO 3
NO 2SW311 3
Gl x
8 PL A
AUTO 3
NO  


VALVE:   2lSW51 and 22SW51 CATEGORY:   c (Check)
VALVE:
CLASS: 3 FUNCTION:   To prevent backflow from the Containment Fan Coil Units into the Nuclear Service Water Header.
2lSW51 and 22SW51 CATEGORY:
TEST REQUIREMENTS:   Verify valve operability every three months.
c (Check)
BASIS FOR RELIEF:   Testing these valves requires isolating service water to 2 Fan Coil Units.
CLASS:
3 FUNCTION:
To prevent backflow from the Containment Fan Coil Units into the Nuclear Service Water Header.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
Testing these valves requires isolating service water to 2 Fan Coil Units.
This places the Plant in a limiting condition for operation (Technical Specification 3.6.2.3).
This places the Plant in a limiting condition for operation (Technical Specification 3.6.2.3).
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
ALTERNATE TESTING:
VALVE: 21SW79 and 22SW79 CATEGORY:   C (Check)
These valves will be tested during Cold Shutdown and Refueling per Section XI.
CLASS: 3 FUNCTION:   Service Water over-load discharge check valves.
VALVE:
TEST REQUIREMENTS:   Verify valve operability every three months.
21SW79 and 22SW79 CATEGORY:
BASIS FOR RELIEF:   These valves cannot be exercised during Power Operation because both Nuclear Headers are required (Technical Specification 3.7.4.1). If the valve were to fail shut the Plant would have to shutdown.
C (Check)
ALTERNATE TESTING:   These valves will be tested during Cold Shutdown and Refueling per Section XI.
CLASS:
Page 82 of 95                             Rev. 0
3 FUNCTION:
Service Water over-load discharge check valves.
TEST REQUIREMENTS:
Verify valve operability every three months.
BASIS FOR RELIEF:
These valves cannot be exercised during Power Operation because both Nuclear Headers are required (Technical Specification 3.7.4.1).
If the valve were to fail shut the Plant would have to shutdown.
ALTERNATE TESTING:
These valves will be tested during Cold Shutdown and Refueling per Section XI.
Page 82 of 95 Rev. 0  


DRAWING N0.~_2_0~5~3~3~3'----~~~~~~~             PAGE   83 of 95   Rev. 0
DRAWING N0.~_2_0~5~3~3~3'----~~~~~~~ PAGE 83 of 95 Rev. 0  
                                  ~
~
en en                 &#xb5;:i                                   E-t
en en  
                &#xb5;:i               ::r: &#xb5;:i                             z E-t               u     p.,
&#xb5;:i E-t  
              .:i:
&#xb5;:i
zH      VALVE z   >t       0::           z       ~
::r:  
VALVE                             H     E-t     0             0                   E-t             REMARKS
&#xb5;:i z
                                                                          ~   Ii< en
E-t u
                                                              ~~
p.,  
                                  ~
~
E-t Nl'MBER               CATEGORY                                                          (NOT TO BE USED FOR RELIEF BASIS)
.:i:
              ~                                 ..i::
z  
Cl)                            &#xb5;:i                             H   ril ril en                             :>
>t 0::
                                                  ~     re ril                              E-t D   HD
z VALVE z
:su  8 u
VALVE H
t'J H
E-t 0
en    ~        u >t
0  
                                                  ..i:: E-t
~
                                                            ' 00 z p.,
E-t REMARKS H
en Ol
~
                                                                    ~~
E-t
                                                                              ....:l Ol
~~
                                                                              ~~
Ii< en Nl'MBER Cl)  
A   B c D E 2SF22   2     Bl     x         x 3     DIA       M           LC     1,3 YES 7
~
2SF36   2     A2     x         x 2     DIA       M           LC     1,3 YES 7
CATEGORY
&#xb5;:i  
..i::
H ril ril (NOT TO BE USED FOR RELIEF BASIS) en ril
~ re E-t D HD
:s 8
t'J  
~
en Ol
....:l Ol H
u >t 00
~~ ~~
u u
en
..i:: E-t z p.,
A B c D
E 2SF22 2
Bl x
x 3
DIA M
LC 1,3 YES 7
2SF36 2
A2 x
x 2
DIA M
LC 1,3 YES 7  


VALVE: 2SF22 and 2SF36 CATEGORY: A/E CLASS: 2 e FUNCTION: Containment Isolation (outside containment) of Spent Fuel Cooling Lines to Reactor Cavity.
VALVE:
TEST REQUIREMENTS: a)   Valve exercising every three months.
2SF22 and 2SF36 CATEGORY:
b)   Leak Rate Testing less than each 24 months.
A/E CLASS:
BASIS FOR RELIEF: a)   Passive valve not required to change position to fulfill its safety function. Valve is kept locked closed per Technical Specification 3.6.3.1, Table 3.6-1.
2 e FUNCTION:
b)   Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.
Containment Isolation (outside containment) of Spent Fuel Cooling Lines to Reactor Cavity.
ALTERNATE TESTING: a)   None.
TEST REQUIREMENTS:
b)   None.
a)
Page 84 of 95                             Rev. 0
Valve exercising every three months.
b)
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
a)
Passive valve not required to change position to fulfill its safety function.
Valve is kept locked closed per Technical Specification 3.6.3.1, Table 3.6-1.
b)
Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.
ALTERNATE TESTING:
a)
None.
b)
None.
Page 84 of 95 Rev. 0  


SYSTEM~~S_T_A_T_I_O_N~A_I_R~(_C_OMP~RE~s_s_E_D~A_I_R_)~_(_S_A_)~~~~~         DRAWING N0.~~2_0_5_3_1_7~~~~~~~~                                 85 of 95   Rev. 0
SYSTEM~~S_T_A_T_I_O_N~A_I_R~(_C_OMP~RE~s_s_E_D~A_I_R_)~_(_S_A_)~~~~~ DRAWING N0.~~2_0_5_3_1_7~~~~~~~~
85 of 95 Rev. 0
[/)
[/)
[/)
[/)                              ll:'.l                                           8 ll:'.l                           ::r::
ll:'.l 8
u ll:'.l                                   z
ll:'.l
                            ~
::r::
r:i..
ll:'.l z  
VALVE z       :><        0::               z         ~
~
VALVE                                                     H       8           0                 0                     8                   REMARKS H                                                                                 ~   r:r.. [/)
u r:i..  
                                                                                                  ~~
~
                                                            ~
VALVE z
8 NUMBER           ti)
0::
                            ~           CATEGORY                     ll:'.l
z VALVE H
:;:.
8 0
                                                                                  .:i::                       H   ll:'.l ll:'.l (NOT TO BE USED FOR RELIEF BASIS)
0  
[/)                                     ll:'.l               :::> ll:'.l           8   :::> H     :::>
~
::&sect;     0
8 REMARKS H  
                                                                      ~
~
N                    8     r:i..             ti) Ol   ....:I Ol 0                               H                   u     :><   I 00 u       u                               [/)                 .:i:: 8       z r:i.. ~~        ~~
8
A   B   c   D   E 2SA118         2       B6           x             x     3         GA         M               LC       1,3 YES 7
~~
                                                                                                                                                                    ;
r:r.. [/)
NUMBER ti)  
~
CATEGORY ll:'.l  
.:i::
H ll:'.l ll:'.l (NOT TO BE USED FOR RELIEF BASIS)
[/)
ll:'.l
:::> ll:'.l 8
H
::&sect; 0
N
~
8 r:i..
I ti) Ol  
....:I Ol 0
H u :><
00  
~~ ~~
u u
[/)  
.:i:: 8 z r:i..
A B c D E 2SA118 2
B6 x
x 3
GA M
LC 1,3 YES 7  


VALVE:* 2SA118 CATEGORY: A/E CLASS: 2 FUNCTION: Containment Isolation of Station Air System.
VALVE:*
TEST REQUIREMENTS: a) Valve exercising every three months.
2SA118 CATEGORY:
b) Leak Rate Testing less than each 24 months.
A/E CLASS:
BASIS FOR RELIEF: a) Passive valve not required to change position to fulfill its safety function. Valve is locked closed per Technical Specification 3.6.3.1, Table 3. 6-1.
2 FUNCTION:
b) Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing ALTERNATE TESTING: a) None b) None.
Containment Isolation of Station Air System.
Page 86 of 95                             Rev. 0
TEST REQUIREMENTS:
a)
Valve exercising every three months.
b)
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
a)
Passive valve not required to change position to fulfill its safety function.
Valve is locked closed per Technical Specification 3.6.3.1, Table 3. 6-1.
b)
Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing ALTERNATE TESTING:
a)
None b)
None.
Page 86 of 95 Rev. 0  


SYSTEM:__~VE_;;_;_N~T_I_LA~TI_O_N~C_O_N_T_A_I_NME~N_T~_<~v_c_>~~~~~~~                         205338                         PAGE   87 of 95   Rev. 0
SYSTEM:__~VE_;;_;_N~T_I_LA~TI_O_N~C_O_N_T_A_I_NME~N_T~_<~v_c_>~~~~~~~
                                                                                                                                  ~~~~~~~~~~-
205338 PAGE 87 of 95 Rev. 0  
Ul Ul       !                      ll:l                                 E-t ll:l                             :i::     ll:l                         z E-t                             u       Pl
~~~~~~~~~~-
                              .:i:
Ul Ul ll:l E-t ll:l
z z       ><  ~              z       ~
:i::
VALVE                                   VALVE              H       E-t 0             0                   E-t                 REMARKS
ll:l z
                                                                                                    ~   r:r..
E-t u
                                                                                          ~~
Pl  
H                               ~
~
E-t                                Ul CATEGORY                                                                    (NOT TO BE USED FOR RELIEF BASIS)
.:i:
                                                                            ~ re
z  
                                                                        ~
~
NUMBER            Ul Ul     5l                              ll:l                             E-t H
z VALVE z
                                                                                                    !:)
VALVE H
ll:l ll:l H     !:)
E-t 0
:&sect;                                                             ,                  H QI u
0  
8u                              N H
~
Ul u ><
E-t REMARKS H
                                                                            .:i: E-t 00 z Pl Ul QI
~
                                                                                                ~~ *~ ~
E-t
B   c   D   E 2VC1             2         El         x                 36       BFY       A     c       1,3     YES
~~
                                                                                                                    -<2 Sec. Cont. Purge 4
r:r.. Ul NUMBER Ul 5l CATEGORY
2VC2             2         El         x                 36       BFY       A     c       1,3     YES 2VC3             2         E2         x                 36       BFY       A     c       1,3     YES 4
~  
2VC4             2         El         x                 36       BFY       A     c       1,3     YES
~ re H
                                                                                                                    -<2 Sec. Cont. Purge 4
ll:l ll:l (NOT TO BE USED FOR RELIEF BASIS)
2VC5             2         Dl         x                 10       BFY       A     c       1,3     YES
Ul ll:l E-t !:)
                                                                                                                    <2 Sec. Cont. Press/Vac. Relief 4
H  
2VC6             2         Dl         x                 10       BFY       A     C.     1,3     YES 4
!:)
2VC7             2         C2         x                 0.75     GL         A     AUTO   1,3     YES
:&sect; 8
                                                                                                                    -<2 Sec. Cont. Atmos. Sample 4
N Ul QI H QI H
2VC8             2         Cl         x                 0.75     GL         A     AUTO   1,3     YES
u ><
                                                                                                                    <2 Sec. Cont. Atmos. Sample 4
00
2VC9             2         C2           x               0.75     GL         A     c       3,4     NO 2VC10           2         Cl           x               0.75     GL         A     c       3,4     NO 2VC11           2         B2         x                 0.75     GL         A     AUTO   1,3     YES         <2 Sec. Cont. Atmos. Sample 4
~~ *~ ~
2VC12           2         Bl         x                 0.75     GL         A     AUTO   1,3     YES         <2 Sec. Cont. Atmos. Sample 4
u u
2VC13           2         B2           x               0.75     GL         A     c       3,4     NO 2VC14           2         Bl           x               0.75     GL         A     c       3,4     NO
Ul
.:i: E-t z Pl A
B c
D E
2VC1 2
El x
36 BFY A
c 1,3 YES  
<2 Sec. Cont. Purge 4
2VC2 2
El x
36 BFY A
c 1,3 YES 2VC3 2
E2 x
36 BFY A
c 1,3 YES 4
2VC4 2
El x
36 BFY A
c 1,3 YES  
<2 Sec. Cont. Purge 4
2VC5 2
Dl x
10 BFY A
c 1,3 YES  
<2 Sec. Cont. Press/Vac. Relief 4
2VC6 2
Dl x
10 BFY A
C.
1,3 YES 4
2VC7 2
C2 x
0.75 GL A
AUTO 1,3 YES  
<2 Sec. Cont. Atmos. Sample 4
2VC8 2
Cl x
0.75 GL A
AUTO 1,3 YES  
<2 Sec. Cont. Atmos. Sample 4
2VC9 2
C2 x
0.75 GL A
c 3,4 NO 2VC10 2
Cl x
0.75 GL A
c 3,4 NO 2VC11 2
B2 x
0.75 GL A
AUTO 1,3 YES  
<2 Sec. Cont. Atmos. Sample 4
2VC12 2
Bl x
0.75 GL A
AUTO 1,3 YES  
<2 Sec. Cont. Atmos. Sample 4
2VC13 2
B2 x
0.75 GL A
c 3,4 NO 2VC14 2
Bl x
0.75 GL A
c 3,4 NO  


VALVE: 2VC1, 2VC4, 2VCS CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Containment Purge (2VC1 and 4) and Pressure Vacuum Relief (2VC5)
VALVE:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
2VC1, 2VC4, 2VCS CATEGORY:
BASIS FOR RELIEF: a) Valve is passive during.Power Operation. This valve cannot be opened during Power Operation per Technical Specification 3.6.i.7.
A CLASS:
b) Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This tests meets the intent of ASME B&PV Code, Section XI for category A valves used for containment isolation.
2 FUNCTION:
ALTERNATE TESTING: a)   These valves will be tested during Cold Shutdown and Refueling per Section XI.
Containment Isolation for Containment Purge (2VC1 and 4) and Pressure Vacuum Relief (2VC5)
b)   Leak Rate Test per Technical Specification 4.6.1.2.d.
TEST REQUIREMENTS:
VALVE: 2VC2, 2VC3, 2VC6 CATEGORY: A CLASS: 2
Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.
  *FUNCTION: Containment Isolation (inside containment) for Containment Purge (2VC2, 3) and Pressure Vacuum Relief (2VC6).
BASIS FOR RELIEF:
TEST REQUIREMENTS: Leak Rate Testing less than 24 months; Stroke Time Testing each three months; Fail safe Testing each three months.
a)
BASIS FOR RELIEF: a) These valves are passive during Power Operation. They cannot be opened per Technical Specification 3.6.1.7.
Valve is passive during.Power Operation.
e                     b) Due to the physical arrangement of these valves a test in the direction of accident flow is not possible. Also, because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This valve cannot be opened during Power Operation per Technical Specification 3.6.i.7.
b)
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This tests meets the intent of ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
a)
These valves will be tested during Cold Shutdown and Refueling per Section XI.
b)
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2VC2, 2VC3, 2VC6 CATEGORY:
A CLASS:
2  
*FUNCTION:
Containment Isolation (inside containment) for Containment Purge (2VC2, 3) and Pressure Vacuum Relief (2VC6).
TEST REQUIREMENTS:
Leak Rate Testing less than 24 months; Stroke Time Testing each three months; Fail safe Testing each three months.
BASIS FOR RELIEF:
a)
These valves are passive during Power Operation.
They cannot be opened per Technical Specification 3.6.1.7.
e b)
Due to the physical arrangement of these valves a test in the direction of accident flow is not possible.
Also, because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used *for containment isolation.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used *for containment isolation.
ALTERNATE TESTING: a)   These valves will be tested during Cold Shutdown and Refueling per Section XI.
ALTERNATE TESTING:
b)   They will be tested in the opposite direction of flow when the 2VC2, 2VC3, and 2VCS are tested in accordance with Technical Specification 4.6.1.2.d.
a)
VALVE: 2VC7 and 2VC8 CATEGORY: A CLASS: 2 FUNCTION: Containment Isolation for Containment Atmospheric Sampling.
These valves will be tested during Cold Shutdown and Refueling per Section XI.
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
b)
BASIS FOR RELIEF: Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME. B&PV Code, Section XI for category A valves used for containment isolation.
They will be tested in the opposite direction of flow when the 2VC2, 2VC3, and 2VCS are tested in accordance with Technical Specification 4.6.1.2.d.
ALTERNATE TESTING: a)   These valves will be tested during Cold Shutdown and Refueling per Section XI.
VALVE:
b)  Leak Rate Test per Technical Specification 4.6.1.2.d.
2VC7 and 2VC8 CATEGORY:
Page 88 of 95                             Rev. 0
A CLASS:
2 FUNCTION:
Containment Isolation for Containment Atmospheric Sampling.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME. B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
a) b)
These valves will be tested during Cold Shutdown and Refueling per Section XI.
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 88 of 95 Rev. 0  


VALVE: 2VC11 and 2VC12 CATEGORY: A CLASS: 2
VALVE:
~ FUNCTION: Containment Isolation for Containment Atmospheric Sampling.
2VC11 and 2VC12 CATEGORY:
TEST REQUIREMENTS: Leak Rate Testing less than each 24 months.
A CLASS:
BASIS FOR RELIEF: Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
2  
ALTERNATE TESTING: Leak Rate Test per Technical Specification 4.6.l.2.d.
~
Page 89 of 95                             Rev. 0
FUNCTION:
Containment Isolation for Containment Atmospheric Sampling.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.l.2.d.
Page 89 of 95 Rev. 0  


SYSTEM   WASTE DISPOSAL - LIQUID   (WL)                                       205339                             PAGE         90 of 95                   Rev. 0
SYSTEM WASTE DISPOSAL -
                                                                                                                          ~--=-=-....::.=:.......::_=;_~--=.;.::,..;,_.:_...::_
LIQUID (WL) 205339 PAGE 90 of 95 Rev. 0  
(/)
~--=-=-....::.=:.......::_=;_~--=.;.::,..;,_.:_...::_
(/)                      '1:J                                    E-<
                        &#xb5;:i                      ::r:    '1:J                          :z; E-<                      u        Ai
                        .:i:
:z;
:z;      ><  i:i::            :z;      ~
VALVE                            VALVE        H
                                                ....... E-<  0                0        gJ        E-<                        REMARKS
                                                                            ~~
H                                      E-<                            ~    (/)
Nl'MBER        (/)
                        ~          CATEGORY              '1:J .:i:                      H    '1:J '1:J      (NOT TO BE USED FOR RELIEF BASIS)
                                                &#xb5;:)      :>                        E-< p
                                                              ~~
(/)                                                                        HP
                  ~
                                                          ~
N                                  (/) QI  H QI u
8 u
H
(/)
(/)
(/)
'1:J E-<
&#xb5;:i
::r:
'1:J
:z; E-<
u Ai
~
.:i:
:z; i:i::
:z; VALVE
:z; VALVE H
E-<
0 0
gJ E-<
REMARKS H
E-<
~~
~ (/)
Nl'MBER
(/)
~
CATEGORY
'1:J
.:i:
H
'1:J '1:J (NOT TO BE USED FOR RELIEF BASIS)
(/)
&#xb5;:)
~~
E-< p HP
~
8 N
~
(/) QI H QI H
u ><
u ><
                                                              .:i: E-<
00
                                                                        '  00
~ gJ lli ~
:z; Ai   ~ gJ    lli  ~
u u
B c D E 2WL12         2       D7     x           3         DIA         A   AUTO     1,3     YES
(/)
                                                                                                        -<10 Sec. Ph. "A" Cont. Isol.
.:i: E-<
4 2WL13         2       D7     x           3         DIA         A   0         1,3     YES
:z; Ai A
                                                                                                        <10 Sec. Ph. "A" Cont. Isol.
B c D
4 2WL16         2       D6     x           3         GL           A   c         1,3     YES
E 2WL12 2
                                                                                                        <10 Sec. Ph. "A" Cont. Isol.
D7 x
4 2WL17         2       D6     x           3         GL           A   c         1,3     YES
3 DIA A
                                                                                                        <10 Sec. Ph. "A" Cont. Isol.
AUTO 1,3 YES  
4 2WL96       2       F7     x           0.75     DIA         A   AUTO     1,3     YES
<10 Sec. Ph. "A" Cont. Isol.
                                                                                                          <10 Sec. Ph. ""A" Cont. Isol.
4 2WL13 2
4 2WL97       2       F7     x           0.75     DIA         A   AUTO     1,3     YES
D7 x
                                                                                                          <10 Sec. Ph. "A" Cont. Isol.
3 DIA A
4 x                                                                            Sec. Ph. "A" Cont. Isol*.
0 1,3 YES  
2WL98       2       F7                 1         DIA         A   0         1,3     YES
<10 Sec. Ph. "A" Cont. Isol.
                                                                                                        -<10 4
4 2WL16 2
x                                                                            Sec. Ph. "A" Cont. Isol.
D6 x
2WL99       2       F7                 1         DIA         A   0         1,3 4
3 GL A
YES
c 1,3 YES  
                                                                                                        -<10 x                                                                                      "A" Cont. Isol.
<10 Sec. Ph. "A" Cont. Isol.
2WL108       2       F7                 1         DIA         A   0         1,3     YES
4 2WL17 2
                                                                                                          -<10 Sec. Ph.
D6 x
4 2WL190       2       E7     x         x 3         DIA         M   LC       1,3     YES 7
3 GL A
2WL191       2         E7     x         x 3         DIA         M   LC       1,3     YES 7
c 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2WL96 2
F7 x
0.75 DIA A
AUTO 1,3 YES  
<10 Sec. Ph. ""A" Cont. Isol.
4 2WL97 2
F7 x
0.75 DIA A
AUTO 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2WL98 2
F7 x
1 DIA A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol*.
4 2WL99 2
F7 x
1 DIA A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2WL108 2
F7 x
1 DIA A
0 1,3 YES  
<10 Sec. Ph. "A" Cont. Isol.
4 2WL190 2
E7 x
x 3
DIA M
LC 1,3 YES 7
2WL191 2
E7 x
x 3
DIA M
LC 1,3 YES 7  


VALVE: 2WL96 and 2WL97 CATEGORY:   A CLASS: 2
VALVE:
* FUNCTION:   Containment Isolation for line from Reactor Coolant Drai~ Tank to Gas Analyzer.
2WL96 and 2WL97 CATEGORY:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
A CLASS:
BASIS FOR RELIEF:   Because the safety-related function of these valves is containment isolation,.
2
they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, section XI for category A valves used for containment isolation.
* FUNCTION:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
Containment Isolation for line from Reactor Coolant Drai~ Tank to Gas Analyzer.
VALVE: 2WL98, 2WL99 and 2WL108 CATEGORY:   A CLASS: 2 FUNCTION:   Containment Isolation from/to Pressurizer Relief Tank to Waste Gas Header and from Nitrogen Header.
TEST REQUIREMENTS:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:   Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
BASIS FOR RELIEF:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
Because the safety-related function of these valves is containment isolation,.
VALVE: 2WL12 and 2WL13 CATEGORY:   A CLASS: 2 FUNCTION:   Containment Isolation from Reactor Drain Tank Pumps to Waste Holdup Tanks.
they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
This test meets the intent of the ASME B&PV Code, section XI for category A valves used for containment isolation.
BASIS FOR RELIEF:   Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE: 2WL16 and 2WL17 CATEGORY:   A CLASS: 2 FUNCTION:   Containment Isolation from Containment Sump Pumps to Waste Holdup Tanks.
VALVE:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
2WL98, 2WL99 and 2WL108 CATEGORY:
BASIS FOR RELIEF:   Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
2 FUNCTION:
Page 91 of 95                             Rev. 0
Containment Isolation from/to Pressurizer Relief Tank to Waste Gas Header and from Nitrogen Header.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2WL12 and 2WL13 CATEGORY:
A CLASS:
2 FUNCTION:
Containment Isolation from Reactor Drain Tank Pumps to Waste Holdup Tanks.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2WL16 and 2WL17 CATEGORY:
A CLASS:
2 FUNCTION:
Containment Isolation from Containment Sump Pumps to Waste Holdup Tanks.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 91 of 95 Rev. 0  


VALVE: 2WL190 and 2WL191 CATEGORY: A/E CLASS: 2 FUNCTION: Containment Isolation (inside containment) of Lines from Reactor Cavity to Spent Fu.el Cooling Pump.
VALVE:
TEST REQUIREMENTS: a)   Valve exercising every three months.
2WL190 and 2WL191 CATEGORY:
b)   Leak Rate Testing less than each 24 months.
A/E CLASS:
BASIS FOR RELIEF: a) Passive valve not required to change position to fulfill its safety function Valve is kept lock shut per Technical Specification 3.6.3.2.d, Table
2 FUNCTION:
Containment Isolation (inside containment) of Lines from Reactor Cavity to Spent Fu.el Cooling Pump.
TEST REQUIREMENTS:
a)
Valve exercising every three months.
b)
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
a)
Passive valve not required to change position to fulfill its safety function Valve is kept lock shut per Technical Specification 3.6.3.2.d, Table
: 3. 6-1.
: 3. 6-1.
b) Technical Specification Table 3.6-1 exempts this valve from Leak Rate Test.
b)
ALTERNATE TESTING: a)   None.
Technical Specification Table 3.6-1 exempts this valve from Leak Rate Test.
b)   None.
ALTERNATE TESTING:
Page 92 of 95                             Rev. 0
a)
None.
b)
None.
Page 92 of 95 Rev. 0  


SYSTEM.~__w_A_T_E_R
SYSTEM.~ __ w_A_T_E_R __ RE c_o_VE __
__RE
RY ____
__c_o_VE
cw_R_-_c_v_c_> ________________ __ DRAWING NO.
__RY ____
2o533o/2o53ol
cw_R_-_c_v_c_>__________________          DRAWING NO.         2 o 533 o/ 2 o 53 ol                . PAGE   93 of 95     Rev. 0
. PAGE 93 of 95 Rev. 0  
                                                                                              ~~------------------~                         ---------------------
~~------------------~
Cl)
Cl)
C/l                               lil                                         8 ril 8
C/l lil 8
ril
::x::
::x::
u ril 0..
ril z
z ici:
8 u
z                                 z        >t       0::             z         ~
0..  
VALVE                                         VALVE          H       8         0               0                   8                     REMARKS H                               ........                                      ~
~
                                                                                                ~~
ici:
8                              Ji:. C/l NUMBER           C/l
z  
                              ~               CATEGORY                 lil       ici:                     H     ri:I ri:I     (NOT TO BE USED FOR RELIEF BASIS)
>t 0::
                                                                          ~
z VALVE z
C/l
VALVE H
                                                                                    ~
8 0
lil
0  
                    ~         8CJ                                N H                 u >t re I 00 8
~
C/l QI H
8 REMARKS H
H QI CJ                                           C/l               ici: 8       z 0.   ~~        ~~
8
A     B c D E 2WR80           2           Gl           x             3           DIA             A     0         1,3       YES       <10 Sec. Ph. "A" Cont. Isol~
~~
4                   (Print #205301) 2WR81           2           G2           x     x       3         CK             SA   c         1,6       YES         (Print #205301)
Ji:. C/l NUMBER C/l  
~
CATEGORY lil ici:
H ri:I ri:I (NOT TO BE USED FOR RELIEF BASIS)
C/l lil
~  
~ re 8
H
~
8 N
I C/l QI H QI H
u >t 00  
~~ ~~
CJ CJ C/l ici: 8 z 0.
A B c D E 2WR80 2
Gl x
3 DIA A
0 1,3 YES  
<10 Sec. Ph. "A" Cont.
Isol~
4 (Print #205301) 2WR81 2
G2 x
x 3
CK SA c
1,6 YES (Print #205301)  


VALVE:   2WR80 CATEGORY:   A CLASS:   2 FUNCTION:   Containment Isolation for Water to Pressurizer Relief Tank and Reactor Coolant Pump Seal Head Tanks.
VALVE:
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
2WR80 CATEGORY:
BASIS FOR RELIEF:   Because the safety-related function of this valve is containment isolation, it will be leak tested in accorda~ce with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
A CLASS:
* ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
2 FUNCTION:
VALVE: 2WL81 CATEGORY: A/C CLASS: 2 FUNCTION: Containment Isolation for Water to Pressurizer Relief Tank and Reactor Coolant Pump Seal Head Tanks.
Containment Isolation for Water to Pressurizer Relief Tank and Reactor Coolant Pump Seal Head Tanks.
TEST REQUIREMENTS:   Leak Rate Testing less than each 24 months.
TEST REQUIREMENTS:
BASIS FOR RELIEF:   Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J. This test meets the intent of the ASME B&PV Code, Section XI for category A valves used .for containment isolation.
Leak Rate Testing less than each 24 months.
ALTERNATE TESTING:   Leak Rate Test per Technical Specification 4.6.1.2.d.
BASIS FOR RELIEF:
Page 94 of 95                             Rev. 0
Because the safety-related function of this valve is containment isolation, it will be leak tested in accorda~ce with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
VALVE:
2WL81 CATEGORY:
A/C CLASS:
2 FUNCTION:
Containment Isolation for Water to Pressurizer Relief Tank and Reactor Coolant Pump Seal Head Tanks.
TEST REQUIREMENTS:
Leak Rate Testing less than each 24 months.
BASIS FOR RELIEF:
Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.
This test meets the intent of the ASME B&PV Code, Section XI for category A valves used.for containment isolation.
ALTERNATE TESTING:
Leak Rate Test per Technical Specification 4.6.1.2.d.
Page 94 of 95 Rev. 0  


PART 3 PIPE SCHEDULES (CLASSIFICATION)
PART 3 PIPE SCHEDULES (CLASSIFICATION)
SCHED.       CLASS SCHED.       CLASS     SCHED.     CLASS SCHED. CLASS AF                   cs                       -RHR             WL & WG S4A             3   SOA             3         SlA         2   S3A       3 S4B           NONE   SOB             3         SlB         2   S3B       3 S4C             3   soc             2                       S3C       3 S4D             3   SOD             3         SJ             S3D       3 S4E             3                             49A         3 S3E       3 CA                       49B         2 S3F
SCHED.
                        -                                                    3 BF                   38A             2         49C         2 S3G       3 16.A           2   38B             3         49D         3 S3H       2 16B         NONE   38C         NONE         49E         2 S3J       2 38D         NONE         49F         2 S3K       3 BR, eve & WR                                 49G         2 S3L       3 48A             2   DR & NT                   49H         2 S3M       2 48B             2   20A             2                         S3N       3 48C             2   20B             2         SS             S30       3 48D             2                             S6A         2 48E             2   FP                       S6B         3 48F             2   27A             2         S6C         2 48G             2   27B             3         S6D         3 48H             2   27C             3         S6E         2 48I             2   27D           NONE 48J             2   27E           NONE         SW 48K             2                             27A         2 48L             2   GB                         27B         3 48M             2   S9A             2         27C         3 48N             2   S9B           NONE         27D       NONE 480             2   S9C           NONE         27E       NONE 48P             3   S9D           NONE 48R             2   S9E           NONE         SF 48S             2   S9F           NONE         SSA         3 SSB         3 CH                 MS                         SSC         2 27A             2   12A             2 27B             3   12B           NONE         SA 27C             3   12C             3         32A         2 27D           NONE 12D             3         32B       NONE 27E           NONE                           32C       NONE RC, PR                     32D       NONE cc       *-        44A             1 S2A             3   44B             1 S2B             2   44C             2 S2C             3   44D             2 S2D             2   44E             2
CLASS SCHED.
.e Page 9S of 9S                   Rev. 0}}
CLASS SCHED.
CLASS SCHED.
CLASS AF cs RHR WL & WG S4A 3
SOA 3
SlA 2
S3A 3
S4B NONE SOB 3
SlB 2
S3B 3
S4C 3
soc 2
S3C 3
S4D 3
SOD 3
SJ S3D 3
S4E 3
49A 3
S3E 3
CA 49B 2
S3F 3
BF 38A 2
49C 2
S3G 3
16.A 2
38B 3
49D 3
S3H 2
16B NONE 38C NONE 49E 2
S3J 2
38D NONE 49F 2
S3K 3
BR, eve & WR 49G 2
S3L 3
48A 2
DR & NT 49H 2
S3M 2
48B 2
20A 2
S3N 3
48C 2
20B 2
SS S30 3
48D 2
S6A 2
48E 2
FP S6B 3
48F 2
27A 2
S6C 2
48G 2
27B 3
S6D 3
48H 2
27C 3
S6E 2
48I 2
27D NONE 48J 2
27E NONE SW 48K 2
27A 2
48L 2
GB 27B 3
48M 2
S9A 2
27C 3
48N 2
S9B NONE 27D NONE 480 2
S9C NONE 27E NONE 48P 3
S9D NONE 48R 2
S9E NONE SF 48S 2
S9F NONE SSA 3
SSB 3
CH MS SSC 2
27A 2
12A 2
27B 3
12B NONE SA 27C 3
12C 3
32A 2
27D NONE 12D 3
32B NONE 27E NONE 32C NONE RC, PR 32D NONE cc 44A 1
S2A 3
44B 1
S2B 2
44C 2
S2C 3
44D 2
S2D 2
44E 2  
.e Page 9S of 9S Rev. 0}}

Latest revision as of 05:43, 6 January 2025

Forwards Revised Pump & Valve Test Program.Program Revised to Incorporate Comments & Revisions Discussed at 800130-31 Meeting W/Nrc.Program for Commercial Phase Will Be Submitted 90 Days Prior to Commercial Operation
ML18082A312
Person / Time
Site: Salem PSEG icon.png
Issue date: 04/23/1980
From: Mittl R
Public Service Enterprise Group
To: Parr O
Office of Nuclear Reactor Regulation
Shared Package
ML18082A314 List:
References
NUDOCS 8005070216
Download: ML18082A312 (95)


Text

PART 1 PUMP TESTING PROGRAM The following pumps will be tested in accordance with Article IWP,Section XI of the ASME Boiler and Pressure Vessel Code.

PUMP DRAWING NUMBER Auxiliary Feed 21, 22, and 23 205336 Boric Acid Transfer 21 and 22 205328 Chilled Water 21 and 22 205316 Charging 23 205328 Charging and Safety Injection 21 and 22 205328 and 205334 Containment Spray 21 and 22 205335 Component Cooling 21, 22 and 23 205331 Residual Heat Removal 21 and 22 205332 Safety Injection 21 and 22 205334 Service Water 21, 22, 23, 24, 25 205342 and 26 Page 1 of 95 Rev. 0

PART 2 VALVE TESTING PROGRAM INDEX ITEM

1.

Abbreviations

2.

Key to Test Requirement

3.

Operational Modes

4.

List of Effective Pages

5.

Valve Listings and Relief Requests by Systems Auxiliary Feed System (AF)

Steam Generator Feed Pump and Condensate (BF)

Chemical and Volume Control (CVC-OPS)

Chilled Water (CH)

Component Cooling (CC)

Containment Spray (CS)

Control Air (CA)

Demineralized Water - Restricted (DR)

Fire Protection (FP)

Fuel Transfer System Steam Generator Drain and Blowdown (GB)

Main Steam (MS)

Nitrogen (NT)

Reactor Coolant (RC, PR)

Residual Heat Removal (RH)

Safety Injection (SJ)

Sampling (SS)

Service Water (SW)

Spent Fuel Cooling (SF)

Station Air (Compressed Air -

SA)

Ventilation Containment (VC)

Waste Disposal Liquid (WL)

Water Recovery (WR-CVC)

Page 2 of 95 PAGE NUMBER 3

5 6

7 8

13 15 24 25 30 33 35 37 39 40 42 47 49 51 54 66 70 83 85 87 90 93 Rev. 0

PART 2 ITEM 1 ABBREVIATIONS

1.

Valve Identification AF Auxiliary Feed BF Stearn Generator Feed CVC Chemical and Volume Control CH Chilled Water CC Component Cooling CS Containment Spray CA Control Air DR Dernineralized Water - Restricted Area FP Fire Protection Fuel Transfer System GB Stearn Generator Drain and Blowdown MS Main Stearn NT Nitrogen RC,PR Reactor Coolant, Pressurizer Relief RH Residual Heat Removal SJ Safety Injection SS Sampling SW Service Water - Nuclear SF Spent Fuel Cooling SA Station Air (Compressed Air)

VC Ventilation Containment WL WasteDisposal - Liquid WR Water Recovery (Chemical and Volume Control)

2.

Valve Type BFY Butterfly CK Check DIA Diaphragm DCK Double Check GA Gate GL Globe NE Needle PL Plug REL Relief SAF Safety SCK Stop Check 3 WAY Page 3 of 95 Rev. 0

PART 2 ITEM 1 Actuator Type A

Air HYD Hydraulic M

Manual MO Motor Operated SA Self Actuated SOL Solenoid STM Steam H/S Hydraulic and Steam

4.

Normal Position AUTO Automatic C

Closed COOL Ported to Coolers LC Locked Closed LO Locked Open L.TH.

Locked Throttled MOD Modulating O

Open PER Stop Check with Valve Stem Backed Off.

REG Regulating TH Throttled VCT Ported to the Volume Control Tank Page 4 of 95 Rev. 0

PART 2 ITEM 2 KEY TO TEST REQUIREMENTS

1.

Category "A" leak rate test per Section XI, Article IWV-3420.

2.

Category "B" exercising test per Section XI, Article IWV-3410, for manual valves.

3.

Category "A" and "B" exercising test per Section XI, Article IWV-3410 and Stroke Time measurement Test per Section XI, Article 3410(c).

4.

Category "A" and "B" fail-safe tests per Section XI, Article 3410(e)

5.

Category "C" (Safety/Relief) valve tests per Section XI, Article 3510.

6.

Category "C" (Check) valve tests per Section XI, Article 3520.

Category "E" (Locked) valve verification per Section XI, Article 3700.

NOTE:

There are no Category "D" valves at Salem 2 that require testing per Section XI.

Page 5 of 95 Rev. 0

MODE

  1. l.
2.
3.
4.
5.
6.

NOTES:

PART 2 ITEM 3 OPERATIONAL MODES REACTIVITY

% RATED AVERAGE COOLANT CONDITION, Keff THERMAL POWER*

TEMPERATURE POWER OPERATION

>0.99

>5%

>350°F STARTUP

>0.99

<5%

>35.0°F HOT STANDBY

<0.99 0

>350°F HOT SHUTDOWN

<0.99 0

3S0°F > T

> 200°F

<200°F avg COLD SHUTDOWN

<0.99 0

REFUELING **

<0.95 0

<140°F For purpose of the IST, modes 1-4 shall be grouped together and referred to as Power Operation.

Excluding decay heat.

Reactor vessel head unbolted or removed and fuel in the vessel.

Page 6 of 95 Rev. 0

March 11, 1980 PART 2 ITEM 4 LIST OF EFFECTIVE PAGES Pages 1 -

95 Page 7 of 95 Rev. 0 Rev. 0

SYSTEM AUXILIARY FEED (AF)

DRAWING NO.

205336 PAGE B of 95 Rev. 0

~~~~~~~--~~~~

~

(/)

(/)

w 8

w

r:

w z

8 u

p.,

~

.:i:

z i:i::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

i:r.. (/)

Nl1MBER

(/)

~

CATEGORY w

.:i:

H w w (NOT TO BE USED FOR RELIEF BASIS)

(/)

w

~~

8 H ::>

j 8

N

~

Ul OI

..:l OI H

u ><

00

~~ ~~

u u

(/)

.:i: 8 z p.,

A B c D

E 21AF4 3

Dl x

6 CK SA c

6 YES 22AF4 3

D3 x

6 CK SA c

6 YES 23AF4 3

D5 x

B CK SA c

6 YES 21AFB 3

E2 x

4, CK SA c

6 YES 22AFB 3

E4 x

4 CK SA c

6 YES 23AFB 3

E6 x

6 CK SA c

6

-YES 21AF11 3

E6 x

4 PL A

MOD 3,4 NO 22AF11 3

F6 x

4 PL A

MOD 3,4 NO 23AF11 3

F6 x

4 PL A

MOD 3,4 NO 24AF11 3

G6 x

4 PL A

MOD 3,4 NO 21AF21 3

GS x

4 GL A

MOD 3,4 NO 22AF21 3

FS x

4 GL A

MOD 3,4 NO 23AF21 3

FS x

4 GL A

MOD 3,4 NO 24AF21 3

F3 x

4 GL A

MOD 3,4 NO 21AF23 3

GB x

x 4

SCK SA/M PER 6,7 YES (Val. Wheel LO) 22AF23 3

GB x

x 4

SCK SA/M PER 6,7 YES (Val. Wheel LO)*

23AF23 3

FB x

x 4

SCK SA/M PER 6,7 YES.

(Val. Wheel LO) 24AF23 3

FB x

x 4

SCK SA/M PER 6,7 YES (Val. Wheel LO) 2AF42 3

C6 x 2.5 GA M

LO 7

NO 2AF99 3

C2 x

0.75 REL SA c

5 NO 2AF103 3

D7 x

2 GL M

LO 7

NO 2AF104 3

D7 x 0.75 GL M

LO 7

NO

e e

e SYSTEM AUXILIARY FEED (AF)

DRAWING N0.___.:2~0~S~3~3~6=--~~~~~~~~ PAGE 9 of 9S Rev. 0

~

en en w

8 w

r::

w z

8 u

p..

~

.:i; z

>t

~

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

8

~~

ri. U)

NttMBER U)

~

CATEGORY w

~ w H

w w (NOT TO BE USED FOR RELIEF BASIS)

U) w 8

i H
J

~

8 N

~

8 p...

en 01 H OI H

u >t 00

~~ ~~

u u

en

.:i; 8 z p..

A B c D

E 2AF10S 3

D7 x

0.7S GL M

LO 7

NO 2AF106 3

D7 x

0.7S GL M

LO 7

NO 2AF128 3

D7 x

l.S REL SA c

s NO 21AFS2 3

El x

6 PL A

c 3

NO 22AFS2 3

E3 x

6 PL A

c 3

NO 23AFS2 3

ES x

8 PL A

c 3

NO 21AFS3 3

El x

6 CK SA c

6 YES 22AFS3 3

E3 x

6 CK SA c

6 YES 23AF53 3

ES x

8 CK SA c

6 YES 21AF3 3

Dl x

6 GA M

LO 7

NO 22AF3 3

D3 x

6 GA M

LO 7

NO 23AF3 3

DS x

8 GA M

LO 7

NO 21AF20 3

GS x

4 GA M

LO 7

NO 22AF20 3

GS x

4 GA M

LO 7

NO 23AF20 3

FS x

4 GA M

LO 7

NO 24AF20 3

F3 x

4 GA M

LO 7

NO 21AF22 3

G6 x

4 GA M

LO 7

NO 22AF22 3

G6 x

4 GA M

LO 7

NO 23AF22 3

F6 x

4 GA M

LO 7

NO 24AF22 3

F4 x

4 GA M

LO 7

NO 2AF1 3

Bl x

10 GA M

LO 7

NO 21AF10 3

G6 x

4 GA M

LO 7

NO

DRAWING N0.~~~2~0~5~3~3~6~~~~~~-

PAGE 10 of 95 Rev. 0 U)

Cl.l w

E-i w

r:

w z

E-i

(.)

0.

~

-=i:

z i:x:

z VP.I.NE z

VALVE H

E-i 0

0

~

E-i REMARKS H

E-i

~~

µ.,

Cl.l Nl'MBER Cl.l

~

CATEGORY w

-=i:

H w w (NOT TO BE USED FOR RELIEF BASIS)

Cl.l w

> w E-i :::>

H

s 8

N

~

E-i 0..

Cl.l QI

!-=I QI H

(.) ><

00

~~ ~~

(.)

(.)

Cl.l

-=i: E-i z 0.

A B c D

E 22AF10 3

G6 x

4 GA M

LO 7

NO 23AF10 3

F6 x

4 GA M

LO 7

NO 24AF10 3

F6 x

4 GA M

LO 7

NO 21AF86 3

G6 x

4 GA M

LO 7

NO 22AF86 3

G6 x

4 GA M

LO 7

NO 23AF86 3

F6 x

4 GA M

LO 7

NO 23AF86 3

F6 x

4 GA M

LO 7

NO

~

VALVE:

21, 22AF4 CATEGORY:

C (Check)

CLASS:

3 FUNCTION:

To ensure proper directional flow through 21 and 22 Auxiliary Feed Pumps.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be full stroke exercised during Power Operation without thermal shocking feed nozzles.

The normal feed path to the Stearn Generators (SGs) is the only available full flow path for testing.

ALTERNATE TESTING:

These valves are partial stroked through the recirc path during Power Operation and Cold Shutdown.

These valves will be manually full stroke exercised per section XI during Refueling.

VALVE:

23AF4 CATEGORY:

C (Check)

CLASS:

3 FUNCTION:

To ensure proper directional flow through #23 Auxiliary Feed Pump.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

This valve cannot be full stroke exercised during Power Operation without thermal shocking. the feed nozzles.

The normal feed path to the SGs is the only available full flow path.

The valve cannot be tested in Cold Shutdown or Refueling because steam must be available to drive the turbine to operate the #23 Auxiliary Feed Pump to exercise 23AF4.

ALTERNATE TESTING:

This valve is partial stroked through the recirc path during Power Operation.

This valve will be manually full stroke exercised per Section XI during Refueling.

VALVE:

21AF8 and 22AF8 CATEGORY:

C (Check)

CLASS:

3 FUNCTION:

Prevent backflow through #21 and #22 Auxiliary Feed Pumps.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation because of thermal shock to feed nozzles on the SGs.

ALTERNATE TESTING:

These valves will be part stroke tested in Cold Shutdown.

These valves will be manually full stroke exercised per Section XI during Refuelins.

VALVE:

23AF8 CATEGORY:

C (Check)

CLASS:

3 FUNCTION:

Prevent backflow through #23 Auxiliary Feed Pump.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

This valve cannot be tested during Power Operation without thermal shocking the feed nozzles on the SGs.

It cannot be flow tested during Cold Shutdown or Refueling because there is no steam available to drive the # 3 Auxiliary Feed Pump Turbine.

ALTERNATE TESTING:

This valve will be manually full stroke exercised per Section XI during Refueling.

Page 11 of 95 Rev. 0

VALVE:

21 -

24AF23 (4 Valves)

CATEGORY:

C/E (Check)

CLASS:

3 FUNCTION:

To prevent backflow of; Stearn Generator water into the Auxiliary Feed System.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Sarne conditions as 21 -

22AF8.

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

21, 22 and 23AF53 CATEGORY:

C (Check)

CLASS:

3 FUNCTION:

To prevent water from the normal suction of the Auxiliary Feed Pumps from bypassing the pump and going into the Dernineralized Water System.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

The line in which this valve is installed is maintained empty and vented to the atmosphere.

We do not fill tnis line except in need as it is routed through a vital relay room and a leak would cause extensive damage and trip the reactor.

ALTERNATE TESTING:

These valves will be manually stroke exercised per Section XI during Refueling.

Page 12 of 95 Rev. 0

SYSTEM:....__S_T_E_AM G_E_N_E_RA_T_O_R_F_E_E_D_AN_D_C;....O_N_D_E_N_S_A_T_E_,,_(B_F__,).___

DRAWING N0._--=2~0~5~3~0~2:.__ ___________ ~ PAGE 13 of 95 Rev. 0

~

Ul Ul w

8 w

r:

w z

8 u

p..

~

<t:

z 0::

z VALVE z

VALVE H

8 0

0 gj 8

REMARKS H

~

8

~~

~ Ul NP MB ER Cl)

~

CATEGORY w

<t:

H w w (NOT TO BE USED FOR RELIEF BASIS)

Cl) w

> w 8

H

s 8

N

~

8 Pl Cl) QI

,_::i QI H

u :><

00

~ gj gj ~

u u

Ul

<t: 8 z p..

A B

c D E 21BF22 2

E7 x

x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO) 22BF22 2

E9 x

x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO) 2~BF22 2

EB x

x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO) 24BF22 2

EB x

x 14 SCK SA/M PER 6,7 YES (Hand Wheel LO)

VALVE:

21 -

24BF22 (4 Valves)

CATEGORY:

C/E (Check)

CLASS:

2 FUNCTION:

To prevent backflow of SG water when Main Feed is secured.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation because 3 loop operation is not permitted.

A Plant trip would be required to exercise these valves to their safety-related position.

ALTERNATE TESTING:

Valve function will be verified during Cold Shutdown and Refueling per Section XI.

Page 14 of 95 Rev. 0

SYSTEM~~-C_H_EM~IC_A_L~A_N_D~V_O_L_U_ME~_C_O_N_T_R_O_L__..(_cv_c_s_-_O_P_S_)'--~~ DRAWING NO.

20S328 PAGE lS of 9S Rev. 0 U)

U)

µ:i 8

µ:i

r:

µ:i z

8 u

A.

~

.:i:

z n::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

8

~~

r..

U)

Nl'MBER en

~

CATEGORY

µ:i

.:i:

H

µ:i <i:l (NOT TO BE USED FOR RELIEF BASIS) en

µ:i

~~

8

i H
i
s 8

N

~

UJ OI H OI H

u ><

00

~~ ~~

u u

U)

.:i: 8 z A.

A B

c D E 2CV3 2

C8 x

2 PL A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2CV4 2

C8 x

2 PL A

0 1,3 YES

<10 Sec. Ph. "A" cont. Isol.

4 2CVS 2

C8 x

2 PL A

0 143 YES

<10 Sec. Ph. "A" Cont. Isol.

2CV6 2

C9 x

2 REL SA c

s NO 2CV7 2

C6 x

2 PL A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2CV40 2

C4 x

4 GA MO 0

3 YES 2CV41 2

C4 x

4 GA MO 0

3 YES 2CV42 2

C4 x

4 CK SA 0

6 YES 2CV43 2

B4 x

0.7S REL SA c

s NO 2CV47 2

AS x

4 CK SA c

6 YES 2CVS2 2

AS x

4 CK SA c

6 YES 2CVSS 2

A6 x

3 PL A

TH 3

NO 2CV63 2

A6 x

3 CK SA 0

6 NO 2CV68

.l.

B8 x

3 GA MO 0

1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

2CV69 1

B8 x

3 GA MO 0

1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

2CV74 1

B8 x

x 3

CK SA c

6 YES 2CV9S 3

BS x

3 GL M

LC 7

NO 21CV98 2

E6 x

x 1 NE M

L.TH.

1,2 YES 7

SYSTEM CHEMICAL AND VOLUME CONTROL (CVCS-OPS)

~~-"""~=.;;.::.=--=;.=.._;,.,c~;;.;;..;;;;;;;........;:~'-'=.=.;;;;""-'~~__.;;.~-'--~~

DRAWING NO.

205328

~~~...::...:::-=-=..:::..:::~~~~~~ PAGE 16 of 95 Rev. 0

~

U)

CJ) w E-<

w

i::

w z

E-<

u P<

~

.:i; z

P::

z VALVE z

VALVE H

E-<

0 0

~

E-<

REMARKS H

E-<

~~

r:r..

CJ)

NUMBER CJ)

~

CATEGORY w

.:i; H

WW (NOT TO BE USED FOR RELIEF BASIS)

CJ) w

~~

E-t ::i H ::J

s 8

N

~

CJ) ()I

,_:i OI H

u ><

00

~~ ~~

u u

CJ)

.:i; E-<

z P<

A B c D

E 22CV98 2

E6 x

x 1

NE M

L.TH.

1,2 YES 7

23CV99 2

D6 x

x 1

NE M

L.TH.

1,2 YES 7

24CV98 2

C6 x

x 1

NE M

L.TH.

1,2 YES 7

21CV99 2

D7 x

2 CK SA 0

6 YES 22CV99 2

D7 x

2 CK SA 0

6 YES 23CV99 2

D7 x

2 CK SA 0

6 YES 24CV99 2

D7 x

2 CK SA 0

6 YES 2CV116 2

D6 x

4 GA MO 0

1 YES

<10 Sec. Ph. "A" Cont. Isol.

2CV131 2

CB x

1 PL A

c 3,4 NO 2CV132 2

C7 x

1 PL A

c 3,4 NO 2CV134 2

C7 x

1 3 WAY A

VCT 3

NO 2CV135 2

A4 x

2 CK SA c

6 NO 2CV137 2

A4 x

2 CK SA c

6 NO 2CV139 2

C4 x

2 GL MO 0

3 NO 2CV140 2

C4 x

2 GL MO 0

3 NO 2CV141 2

A6 x

0.75 REL SA c

5 NO 2CV147 2

Fl x

2 CK SA c

6 NO 21CV151 2

Dl x

2 DIA M

LC 7

NO 22CV151 2

Dl x

2 DIA M

LC 7

NO 21CV154 2

El x

2 CK SA c

6 NO

e e

e SYSTEM CHEMICAL AND VOLUME CONTROL (CVC-OPS)

DRAWING NO..

205328 PAGE J7 of 95 ReY* 0 U)

U) r:Ll 8

r:Ll

r:

r:Ll z

8 u

11<

~

i<I; z

P::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

rr..

U)

NV MEER U)

[ii CATEGORY r:Ll i<I; H

r:Ll r:Ll (NOT TO BE USED FOR RELIEF BASIS)

U) r:Ll

~~

E-l ::i H

J

~

8 N

~

U) QI

,_:i QI H

u ::...

00

~~ ~~

u u

U) i<I; 8 z 11<

A B c D

E 22CV154 2

El x

2 CK SA c

6 NO.

21CV156 2

El x

2 DIA M

c 2

NO 22CV156 2

El x

2 DIA M

c 2

NO 21CV160 2

Fl x

2 PL A

c 3

NO 22CV160 2

Fl x

2 PL A.

c 3

NO 2CV172 2

E2 x

2 PL A

AUTO 3

NO 2CV173 2

D2 x

2 CK SA c

6 NO 2CV175 2

E3 x

2 GL MO c

3 NO 2CV176 2

E3 x

2 CK SA c

6 YES 2CV179 2

F3 x

2 PL A

AUTO 3

NO 2CV180 2

F3 x

2 CK SA c

6 NO 2CV181 2

G3 x

2 DIA A

AUTO 3,4 NO 2CV185 2

D3 x

2 DIA A

AUTO 3,4 NO 2CV196 2

D4 x

1 CK SA 0

6 YES 2CV241 2

G4 x

3 REL SA c

5 NO 2CV278 2

C8 x

1 PL A

c 3,4 NO 2CV284 2

D6 x

4 GA MO 0

1 YES

<10 Sec. Ph. "A" Cont. Isol.

2CV44 2

B4 x

6 GA M

LO 7

NO 2CV49 2

A4 x

6 GA M

LO 7

NO 2CV48 1

B6 x

4 GA M

LO 7

NO 2CV53 1

A6 x

4 GA M

LO 7

NO 2CV54 1

A6 x

3 GL M

LO 7

NO

SYSTEM~~~C=H=E=M=I~C=AL=-~AN~D_V~O=L=U=ME-=-~C~O=N=T=R~O=L..__~~~~~~~ DRAWING N0.~~2~0=5=3=2=8'--~~~~~~~ PAGE 18 of 95 Rev. O Ul Ul w

8 w

r:

r:a z

8 u

P<

~

,:i:

z

>i ii:::

z VALVE z

VALVE H

8 0

0 gJ 8

REMARKS H

8

~~

r... Ul Nl'MBER Ul

§ CATEGORY w

,:i:

H w r:a (NOT TO BE USED FOR RELIEF BASIS)

Ul w

~~

8 H

j 8

N

~

I Ul OI

..:IOI H

u >i 00 g:1 gJ

~~

u u

Ul

,:i: 8 z P<

A B c D

E 2CV56 1

A6 x

3 GL M

LO 7

NO 2CV296 2

ca x

x 0.-75 CK SA 0

1,6 YES

VALVE:

2CV3, 2CV4, 2CV5 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Reactor Coolant Letdown.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

)

BASIS FOR RELIEF:

Because the* safety-related function of these valves is containment isolation they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI, for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CV7 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Reactor Coolant Letdown Line.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.

BASIS FOR RELIEF:

a)

This valve cannot be exercised during Power Operation because this would isolate normal letdown flow through the Regenerative Heat Exchanger causing the injection of cold water into the RCS resulting in thermal cycling of injection nozzles and possible cracking damage.

b)

Because the safety-related function of this valve is containment ALTERNATE TESTING:

a) b)

VALVE:

2CV40 and 2CV41 CATEGORY:

B CLASS:

2 isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI, for category A valves used for containment isolation.

Testing will be performed during Cold Shutdown and Refueling per Section XI.

Leak Rate Test per Technical Specification 4.6.1.2.d.

FUNCTION:

Volume Control Tank Outlet isolation valves.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

Closing these valves during Power Operation requires lining up the alternate source of water from the Refueling Water Storage Tank to the suction of the Charging Pumps.

This is 2,000 ppm borated water which would render the reactor subcritical.

ALTERNATE TESTING:

Testing will be performed during Cold Shutdown and Refueling per section XI.

Page 19 of 95 Rev. 0

VALVE:

2CV42 CATEGORY:

c (Check)

CLASS:

2 FUNCTION:'

To prevent backf low into the Volume Control Tank from the suction of the Charging Pumps.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

This valve cannot be exercised during Power Operation.

Exercising (closing) would result in a loss of normal make-up to the RCS, Pressurizer Level Control. and RCP Seal Flow.

This would require a reactor trip.

Use of the only alternate suction for the Charging Pumps, the RWST, which is water borated to % 2000 ppm, would result in a Reactor Shutdown.

ALTERNATE TESTING:

This valve will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2CV68 and 2CV69 CATEGORY:

A CLASS:

1 FUNCTION:

Containment Isolation from Charging Pumps to Regenative Heat Exchanger.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; stroke Time Testing each three months; Fail Safe Testing each three months.

BASIS FOR RELIEF:

a)

Thse valves cannot be exercised during Power Operation.

If these valves failed shut during testing loss of Pressurizer Level Control would result requir.ing a Reactor Trip.

b)

Beacuse the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

~

ALTERNATE TESTING:

a)

These valves will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CV74 CATEGORY:

A/C (Check)

CLASS:

1 FUNCTION:

To ensure proper direction flow through the Regenerative Heat Exchanger.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; verify valve operability every three months.

(

BASIS FOR RELIEF:

a)

Shutting this valve during Power Operation would cause a loss of Pressurizing Level Control and a Reactor Trip would result.

b)

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI; for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

This valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 20 of 95 Rev. 0

VALVE:

21 -

24CV99 (4 Valves)

CATEGORY:

C (Check)

CLASS:

2

~

FUNCTION:

To ensure proper flow direction through Reactor Coolant Pump Seals.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation without securing seal water to a RCP resulting in a loss of a RCP requiring a Reactor Trip.

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2CV116 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Reactor Coolant Pump seal water return line.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.

BASIS FOR RELIEF:

a)

These valves cannot be exercised during Power Operation.

Shutting these valves would cause a RCP trip which would then cause a Reactor Trip.

b)

Beacuse the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.. This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

This valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CV176 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To ensure proper flow direction in the Rapid Boration Line.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Testing during Power Operation would cause a loss in Reactor Power due to high boron injection.

ALTERNATE TESTING:

This valve will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2CV196 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent backflow of water from the Charging Pump suction into the Chemical Addition Tank.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

This valve is a category c passive valve not required to change position to perform its safety-related function.

ALTERNATE TESTING:

None.

Page 21 of 95 Rev. 0

VALVE:

2CV284 CATEGORY:

A CLASS:

2

~

FUNC~ION: Containment Isolation from Reactor Coolant Pump Seal Water Return Line.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.

BASIS FOR RELIEF:

a)

Seal return line cannot be isolated during Power Operation without tripping a RCP which will cause a Reator Trip.

b)

Beacuse the safety-related function of this valve is containment isolation, it will be tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,.Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

This valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CV47, 2CV52 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent backflow through the #21 and #22 Charging/Safety Injection (HPSI) Pumps.

TEST REQUIREMENTS:

BASIS FOR RELIEF:

ALTERNATE TESTING:

VALVE:

2CV296 Verify valve operability every three months.

Valve cannot be full stroke exercised during Power Operation due to limited size of Letdown Line.

This valve will be part stroke tested quarterly per Section XI.

The method and frequency for full stroke testing is still under review.

CATEGORY:

A/C (Check)

CLASS:

2 FUNCTION:

Overpressure protection for Containment Isolation Piping.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Verify valve operability every three months.

BASIS FOR RELIEF:

a)

This valve cannot be shut without shutting 2CV284.

See relief request for 2CV284.

b)

Beacuse the safety-related function of this valve is containment isolation, it will be tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

This valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 22 of 95 Rev. 0

VALVE:

21 -

24CV98 (4 Valves)

CATEGORY:

A/E CLASS:

2 FUNCTION:

Throttle Valve for RCP seal flow.

TEST REQUIREMENTS:

a)

Valve exercising each three months.

b)

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

a)

Valves cannot be shut during Power Operation without causing a loss of seal flow to a RCP.

This would cause a RCP trip which would cause a R~actor Trip.

b)

Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.

ALTERNATE TESTING:

a)

Valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

None.

Page 23 of 95 Rev. 0

SYSTEM~~-C_H_I_L_LE_D~W_A_T_E_R~(_C_H_)~~~~~~~~~~~~

205316 PAGE 24 of 95 Rev. 0

~

U)

U) w E-1 w

r:

w z

E-1 u

0.

~

ici::

z

!>I

~

z VALVE z

VALVE H

E-1 0

0

~

E-1 REMARKS H

~

E-1

~~

r:r..

U)

NUMBER l'J)

CATEGORY w

ici::

H WW (NOT TO BE USED FOR RELIEF BASIS)

U) w

i w E-1 ::i H
J
'.§ 8

N

~

E-1 0.

Ul OI

...:IOI H

u !>I 00

~~ ~~

u u

U) ici::

E-1 z 0.

A B c D

E 21CH13 3

D2 x

4 CK SA c

6 NO 22CH13 3

D3 x

4 CK SA c

6 NO 2CH30 3

F4 x

3 GL A

0 3,4 NO 2CH74 3

C3 x

3 3 WAY A

COOL 3,4 NO 2CH143 3

Dl x

0.75 REL SA c

5 NO 2CH151 3

F4 x

3 GL A

0 3,4 NO 2CH168 3

Bl x

1.5 PL A

c 3,4 NO

SYSTEM~ __

c_o_M_P_O_N_E_N_T_C_O_O_L_I_N_G __ (~c_c~>--------------------~ DRAWING NO.

205331


=;...;;....;;;-=....=:..;;;;;_ __________

~ PAGE 25 of 95 Rev. 0

~

(/)

(/)

li:i 8

li:i

.r:

li:i z

8 u

11<

~

.:i:

z p:;

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

rr.. (/)

NllMBER ti)

&]

CATEGORY li:i

.:i:

H li:i li:i (NOT TO BE USED FOR RELIEF BASIS)

(/)

li:i

J li:i 8
J

. H

J j

8 N

~

8 11<.

(/) ()j

,_:i Ol H

u :><

00

~~ ~~

u u

(/)

.:i: 8 z 11<

A B c D.E 21CC1 3

F2 x

12 CK SA 0

6 NO 22CC1 3

E2 x

12 CK SA 0

6 NO 23CC1 3

E2 x

12 CK SA 0

6 NO 21CC14 3

E9 x

1 REL SA c

5 NO 22CC14 3

F9 x

1 REL SA c

5 NO 21CC15 3

E9 x

12 BFY M

L.TH.

7 NO 22CC15 3

F9 x

12 BFY M

L.TH.

7 NO 21CC16 3

E9 x

12 GA MO c

2 NO 22CC16 3

F9 x

12 GA MO c

2 NO 21CC23 3

GB x

1 GL M

L.TH.

7 NO 22CC23 3

FB x

1 GL M

L.TH.

7 NO 2CC26 3

G6 x

1 GL M

L.TH.

7 NO 2CC29 3

E7 x

1 GL M

L.TH.

7 NO 2CC37 3

El x

10 BFY M

L.TH.

7

  • No 2CC75 3

C2 x

0.75 REL SA c

5 NO 2CC78 3

C2 x

3 GL M

L.TH.

7 NO 2CC100 3

F7 x

1 GL M

L.TH.

7 NO 2CC103 3

GS x

1 GL M

L.TH.

7 NO 2CC107 3

F7 x

2 GL M

L.TH.

7 NO 2CC113 2

B7 x

3 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

2CC117 2

B7 x

6 GA MO 0

1,3 YES

<10 Sec. Ph. "B" Cont. Isol.

2CC118 2

B7 x

6 GA MO 0

1,3 YES

<:10 Sec. Ph. "B" Cont. Isol.

COMPONENT COOLING (CC)

DRAWING NO.

205331 PAGE 26 of 95 Rev. 0 Cl)

CJ) w 8

w

r:

ril z

8 u

lli

~

!<I; z

0:

z VALVE z

VALVE H

8 0

0

~

E-!

REMARKS H

8

~~

Ii. CJ)

NUMBER CJ)

~

CATEGORY r.LI

!<I; H

ril r.LI (NOT TO BE USED FOR RELIEF BASIS)

CJ) r.LI

~ re E-! ::i H ::i

s 8

N

~

CJ) QI

...:I QI H

CJ ><

00

~~ ~~

u u

CJ)

!<I; 8

z lli A

B c D

E 2CC131 2

B7 x

3 GA MO 0

1,3 YES

<10 Sec. Ph. "B" Cont. Isol.

2CC136 2

A7 x

6 GA MO 0

1,3 YES

<10 Sec. Ph. "B" Cont. Isol.

2CC138.

3 El x

0.75 REL SA*

c 5

NO 2CC147 3

Gl x

3 SAF SA c

5 NO 2CC187 2

B7 x

6 GA MO 0

1,3 YES

<10 Sec. Ph. "B" Cont. Isol.

2CC190 2

B7 x

3 GA MO 0

i,3 YES

<10 Sec. Ph. "B" Cont. Isol.

2CC215 2

B6 x

3 PL A

0 1,3 YES

<10 Sec. Ph. "A" Corit. Isol.

4 2CC317 3

E6 x

1 CK SA 0

6 NO 2CC318 3

FS x

1 GL M

LC 7

NO 2CC320 3

GS x

1 CK SA 0

6 NO 2CC186 2

C7 x

x 0.75 CK SA 0

1,6 YES 2CC208 2

B7 x

x 0.75 CK SA 0

1,6 YES

VALVE:

2CC113 CATEGORY:

A CLASS:

2 e FUNCTION:

Containment Isolation from outlet of Excess Letdown Heat Exchanger.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CC117 and 2CC118 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Component Cooling to and return from the Reactor Coolant Pumps.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.

BASIS FOR RELIEF:

a)

These valves cannot be exercised during Power Operation because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a Reactor Trip.

ALTERNATE TESTING:

b)

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV code,Section XI for category A valves used for containment isolation.

a)

These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CC131 and 2CC136 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Component Cooling to and return from the Reactor Coolant Pumps.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.

BASIS FOR RELIEF:

a)

These valves cannot be exercised during Power Operation because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a reactor trip.

b)

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 27 of 95 Rev. 0

VALVE:

2CC187 and 2CC190 CATEGORY:

A CLASS:

2 FUNCTION:

  • I ConFairunent Isolation for Component Cooling to and from the Reactor Coolant Pump.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months.

BASIS FOR RELIEF:

a)

These valves cannot be exercised during Power Operations because if the valves failed shut a loss of RCP cooling would occur requiring the RCP be secured and thus requiring a Reactor Trip.

b)

Because the safety-rela-t;.ed function of these valves is contairunent isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for contairunent isolation.

ALTERNATE TESTING:

a)

These valves will be tested during Cold Shutdown and Refueling per Section XI when RCPs can be secured.

bl Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CC186 CATEGORY:

A/C (Check)

CLASS:

2 FUNCTION:

Overpressure protection for contairunent isolation piping.

TEST REQUIREMENTS:

a)

Verify valve operability every three months.

b)

Leak Rate Testing less than each 24 months.

~BASIS FOR RELIEF:

a)

Valve cannot be shut without shutting 2CC187.

See relief_request for 2CC187.

e*

b)

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for contairunent isolation.

ALTERNATE TESTING:

a)

This valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2CC208 CATEGORY:

A/C (Check)

CLASS:

2 FUNCTION:

Overpressure protection for contairunent isolation piping.

TEST REQUIREMENTS:

a)

Verify valve operability every three months.

b)

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

a)

Valve cannot be shut with out shutting 2CC190.

See relief request for 1CC190.

b)

ALTERNATE TESTING:

a)

Because the safety-related function of this valve is contairunent isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for contairunent isolation.

This valve will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 28 of 95 Rev. 0

VALVE:

2CC215

\\

CATEGORY:

A CLASS:

2

~

FUNCTION:

Containment Isolation.

Inlet to Excess Letdown Heat Exchanger.

TEST REQUIREMENTS:

Leak Rate Testing less tha.n each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI, for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 29 of 95 Rev. 0

CONTAINMENT SPRAY DRAWING NO.

20S33S PAGE 30 of 9S Rev. 0

~~~~~~~~~~~~

Ul U)

J:xl 8

J:xl

r:

J:xl z

8 u

p..

~

i<l!

z IZ

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

E-!

~~

rz.. en Nl'MBER en

~

CATEGORY J:xl i<l!

H J:xl J:xl (NOT TO BE USED FOR RELIEF BASIS)

Ul J:xl J:xl 8

H j

8 N

~

8 p...

en QI

,_::i QI H

u ><

00

~~ ~~

u u

Ul i<l! 8

z p..

A B c D

E 21CS2 3

F4 x

8 GA MO c

3 NO 22CS2 3

E4 x

8 GA MO c

3 NO 21CS4 2

FS x

8 CK SA c

6 YES 22CS4 2

ES x

8 CK SA c

6 YES 21CSS 2

F6 x

0.7S REL SA c

s NO 22CSS 2

E6 x

0.7S REL SA c

s NO 2CS14 3

C4 x

3 GA MO LO 7

NO 2CS16 3

DS x

3 GA MO c

3 NO 2CS17 3

DS x

3 GA MO c

3 NO 21CS21 3

FS x

3 CK SA c

6 YES 22CS21 3

ES x

3 CK SA c

6 YES 2CS26 3

C3 x

0.7S REL SA c

s NO 21CS36 2

F6 x

8 GA MO c

3 YES 22CS36 2

D6 x

8 GA MO c

3 YES 21CS47 2

F6 x 0.7S GL M

LO 7

NO 22CS47 2

D6 x 0.7S GL M

LO 7

NO 21CS48 2

F6 x

8 CK SA c

6 YES 22CS48 2

E6 x

8 CK SA c

6 YES 21CS1 1

G2 x

10 GA M

LO 7

NO 22CS1 1

E2

  • X 10 GA M

LO 7

NO 21CS11 1

F4 x

2 GL M

LO 7

NO 22CS11 1

F4 x

2 GL M

LC 7

NO

e e

e SYSTEM CONTAINMENT SPRAY DRAWING NO.

20533S

~~~~~~~~~~~~ PAGE 31 of 95 Rev. 0 CJ)

CJ) l'.Ll 8

l'.Ll

r:

l'.Ll z

8 CJ p,

~

.:i:

z IZ z

VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~*~

µ..

CJ)

NtTMBER CJ)

~

CATEGORY l'.Ll

.:i:

H l'.Ll l'.Ll (NOT TO BE USED FOR RELIEF BASIS)

CJ) l'.Ll

~

~~

8 H

§ 8

N CJ) QI H QI H

CJ ><

00

~~ ~~

u u

CJ)

.:i: 8 z p, A

B c D

E 2CS35 1

B2 x. 2 GL M

LC 7

NO 21CS44 2

G7 x

8 GA M

LC 7

NO 22CS44 2

E7 x

8 GA M

LC 7

NO 21CS6 2

G7 x *s GA M

LO 7

NO 22CS6 2

E7 x

8 GA M

LO 7

NO 21CS20 2

GS x

3.

DIA M

LO 7

NO 22CS20 2

FS x

3 DIA M

LO 7

NO 2CS31 2

DS x

3 CK M

LC 7

NO

VALVE:

21CS4 and 22CS4 CATEGORY:

c (Check)

CLASS:

2 FUNCTION:

To provide directional flow of water into the containment spray headers.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation or Cold Shutdown without spraying down the containment, causing equipment and lagging damage requiring extensive clean-up and repair.

The full flow test connection is connected to the refueling cavity and can only be used during Refueling.

ALTERNATE TESTING:

These valves will be tested during Refueling per Section XI.

VALVE:

21CS48 and 22CS48 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To provide proper directional flow of water into the Containment Spray Headers.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation or Cold Shutdown without spraying down the containment, causing equipment and lagging damage requiring extensive clean-up and repair.

The full flow test connection is connected to the refueling cavity and can only be used during Refueling.

ALTERNATE TESTING:

These valves will be tested during Refueling per Section XI.

VALVE:

21 and 22CS21 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent backflow into the spray additive tank.

The safety-related position is open to allow the caustic solution in the Spray Additive Tank to be educted into the C.S. System and sprayed into the containment.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Only partial stroke is possible due to the limited size of the recirc line.

ALTERNATE TESTING:

These valves will be part st.eke tested quarterly per Section XI.

The method and frequency for full stroke testing is still under review.

VALVE:

21 and 22CS36 CATEGORY:

B CLASS:

2 FUNCTION:

To allow the RHR (LPSI) pumps to pump into the CS System when in recirculation mode.

TEST REQUIREMENTS:

Valve exercising each three months; Stroke Time Testing each three months.

BASIS FOR RELIEF:

The valve will be tested during Power Operation.

However, it cannot be opened when the RHR System is in service without spraying down the Containment, causing equipment and lagging damage requiring extensive clean-up and repair.

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI when the RHR system is not in service.

Page 32 of 95 Rev. O

SYSTEM;__ ____

c_o_N_T_R~O_L_A_I_R __ (_c_A_) __________ ~----------~ DRAWING NO.

205347 PAGE 33 of 95 Rev. 0

(/)

(/)

ril 8

ril

r:

ril z

8 u

ti.

~

,:(

z

~

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

8

~ ~*

rr.. (/)

Nl'MBER

(/)

§ CATEGORY ril

,:(

H ril ril (NOT TO BE USED FOR RELIEF BASIS)

(/)

ril

~ re E-1::>

HP j

8 N

~

(/) QI

,_::i QI H

u :>!

00

~~ ~ gi CJ CJ

(/)

,:( E-1 z ti.

A B c

D *E 21CA330 2

B5 x

2 GA A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 22CA330 2

B5 x

2 GA A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4

VALVE:

21CA330 and 22CA330 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Containment Control Air Headers.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical SPecifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for the containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 34 of 95 Rev. 0

SYSTEM DEMINERALIZED WATER -

RESTRICTED AREA (DR)

DRAWING NO.

205246

~~.;::_:_.=.....::....:.~~~~~~~~ PAGE 35 of 95 Rev. 0

~

U)

U)

IL!

8 fil

r:

IL!

z 8

u Pi

~

.:i:

z IZ z

VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~§ Ii< Cl)

NUMBER Cl)

~

CATEGORY IL!

.:i:

H IL! IL!

(NOT TO BE USED FOR RELIEF BASIS)

U)

µ:i

~

IL!

8

i H
J j

8 N

~

Pi U) QI

,_:i QI H

u ><

00

~~ ~~

u u

U)

.:i: 8 z Pi, A

B c D

E 2DR29 2

D2 x

4 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4

VALVE:

2DR29 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation valve for Containment Demineralized Water Header.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 36 of 95 Rev. 0

SYSTEM-___;;F_I_RE P_~_O_TE_C_T_I_O_N __________________________ ~

205222 PAGE 37 of 95 Rev. 0 Cl)

Cl) lil 8

lil

r:

lil z

8 u

p..

~

.:i:

z*

>t n::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

r:r..

Cl)

NUMBER Cl)

§ CATEGORY lil

~ re H

lil lil (NOT TO BE USED FOR RELIEF BASIS)

.Cl) lil

~

8

i H ::>
§ 8

N Ul OI

..:! OI H

u >t 00

~~ ~~

u u

Cl)

.:i: 8 z p..

A B c D E 2FP147 2

B3 x

4 PL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4

VALVE:

1FP147 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation valve for Containment Fire Protection Header.

TEST REQUIREMENTS:

Leak Rate Tes.ting less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Pµge 38 of 95 Rev. 0

DRAWING NO.

NO PIPING DIAGRAM PAGE 39 of 95 Rev. 0 Ul Ul

µ:i 8

µ:i

i::

µ:i

z 8

u p..

gj

,:(

z

~

z VALVE

z VALVE H

8 0

0

~

8 REMARICS H

8

~~

rr.. Ul Nl'MBER Ul

~

CATEGORY

µ:i

@ µ:i H

µ:i

µ:i (NOT TO BE USED FOR RELIEF BASIS)

Ul

µ:i 8

H j

8 N

~

8 p..

Ul QI

....:I QI H

u ><

00

~~ ~~

u u

Ul

,:( 8

z p..

A B c D E Fuel Trans 3

N/A x

12 GA M

LC 7

NO Containment Secondary Isolation Tube IV (Primary is blank flange)

SYSTEM;..__.;.;;S~T_E_AM __

G_EN_E_RA_T_O_R_D_RA_I_N_AN_D_B_L_O_WD_O_WN_"""'(_G_B~) __ DRAWING NO.

205325


~-~ PAGE 40 of 95 Rev. 0 U)

U) li'l 8

li'l

r:

li'l z

8 u

p.,

~

!Cl!

z P:

z VALVE z

VALVE H

8 0

0 gJ 8

REMARKS H

~

8

~~

µ,

U)

NUMBER U)

~

CATEGORY li'l

3 li'l H

li'l li'l (NOT TO BE USED FOR RELIEF BASIS)

U) li'l

~

8P HP

s 8

t'I 8

p.,.

U) QI H QI H

u ><

00

~ gJ

~ gJ u

u U)

!Cl! 8 z p.,

A B c D E 21GB4 2

D4 x

3 PL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 22GB4 2

D4 x

3 PL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4*

23GB4 2

D4 x

3 PL A

c 1,3 YES

<10 Sec. Ph. "A" Cont.. Isol.

4 24GB4 2

D4 x

3 PL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4

VALVE:

21 -

24GB4 (4 Valves)

CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation of Steam Generator Drain and Blowdown Lines.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.*

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 41 of 95 Rev. 0

e e

e SYSTEM MAIN STEAM (MS)

DRAWING NO.

205303

~~~~~~~~~~~~ PAGE 42 of 95 Rev. O U)

U) rzl 8

rzl

r:

rzl z

8 u

A<

~

.:i:

z 0::

z VALVE z

VALVE H

8 0

0 gj 8

REMARKS H

~

8 i~

r.. U)

NUMBER Cl)

~

CATEGORY rzl

.:i:

H rLI rLI (NOT TO BE USED FOR RELIEF BASIS)

U) w

> rLI 8

H j

8 N

~

8 A<.

U) ()I

,_:i OI H

u ><

00

~ gj

~~

u u

U)

.:i: 8 z A<

A B

c D

E 21MS7 2

F2 x

2 GA A

c 3,4 NO 22MS7 2

C2 x

2 GA A

c 3,4 NO 23MS7 2

E2 x

2 GA A

c 3,4 NO 24MS7 2

D2 x

2 GA A

c 3,4 NO 21MS11 2

E2 x

6 SAF SA c

5 NO 22MS11 2

D2 x

6 SAF

  • SA c

5 NO 23MS11 2

F2 x

6 SAF SA c

5 NO 24MS11 2

C2 x

6 SAF SA c

5 NO 21MS12 2

E2 x

6 SAF SA c

5 NO 22MS12 2

D2 x

6 SAF SA c

5 NO 23MS12 2

F2 x

6 SAF SA c

5 NO 24MS12 2

C2 x

6 SAF SA

' c.

5 NO 21MS13 2

E2 x

6 SAF SA c

5 NO 22MS13 2

D2 x

6 SAF SA c

5 NO 23MS13 2

F2 x

6 SAF SA c

5 NO 24MS13 2

C2 x

6 SAF SA c

5 NO 21MS14 2

E2 x

6 SAF SA c

5 NO 22MS14 2

D2 x

6 SAF SA c

5 NO 23MS14 2

F2 x

6 SAF SA c

5 NO 24MS14 2

C2 x

.6 SAF SA c

5 NO 21MS15 2

E2 x

6 SAF SA c

5 NO 22MS15 2

D2 x

6 SAF SA c

5 NO

SYSTEM MAIN STEAM (MS)

DRAWING N0.~-=20~5~3~0~3::;__~~~~~~~ PAGE 43 of 95 Rev. 0

~

U)

U)

µ:i E-<

µ:i

r:

µ:i z

E-<

u 11<

~

<l; z

p:;

z VALVE z

VALVE H

E-<

0 0

~

E-<

REMARKS H

~

E-<

~~

µ.,

U)

NUMBER U)

CATEGORY

µ:i

<l; H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

U)

µ:i

µ:i E-< :::>

H j

8 N

~

t; g:.

U) QI

,_:i QI H

00

~~ ~~

u u

U)

<l; E-<

z 11<

A B c 0

E 23MS15 2

F2 x

6 SAF SA c

5 NO 24MS15 2

C2 x

6 SAF SA c

5 NO 21MS18 2

F2 x

3 GA A

c 3,4 NO 22MS18 2

C2 x

3 GA A

c 3,4 NO 23MS18 2

E2 x

3 GA A

c 3,4 NO 24MS18 2

D2 x

3 GA A

c 3,4 NO 21MS45 2

Fl x

6 GA M

LO 7

NO 23MS45 2

El x

6 GA M

LO 7

NO 21MS46 2

G2 x

6 CK SA c

6 NO 23MS46 2

G2 x

6 CK SA c

6 NO 2MS52 3

G3 x

4 BFY SOL 0

2 YES 2MS53 3

G3 x

4 GA A

0 2

YES 2MS132 2

G2 x

6 GA A

c 3,4 NO 21MS167 2

F2 x

32 GA H/S 0

3 YES

<5 Sec.

22MS167 2

C2 x

32 GA H/S 0

3 YES

<5 Sec.

23MS167 2

02 x

32 GA H/S 0

3 YES

<5 Sec.

24MS167 2

E2 x

32 GA H/S 0

3 YES

<5 Sec.

21MS169 2

F2 x

2 GA A

c 3,4 YES 22MS169 2

C2 x

2 GA A

c 3,4 YES 23MS169 2

02 x

2 GA A

c 3,4 YES 24MS169 2

E2 x

2 GA A

c 3,4 YES 21MS171 2

F2 x

2 GA A

c 3,4 YES

SYSTEM.~--MA~I_N........;:;S~T~E_AM~--=-(M~S~)~~----~~--~~--~----

DRAWING NO.

205303

~----------~--------~ PAGE 44 of 95 Rev. 0 Cl)

Cl) l:il E-l l:il

r:

l:il z

E-l u

ii.

~

ice z

P::

z VALVE z

VALVE H

E-l 0

0

~

E-l REMARKS H

~

E-l

~~

Iii Cl)

NUMBER Cl)

§ CATEGORY l:il ice H

l:il l:il (NOT TO BE USED FOR RELIEF BASIS)

Cl) l:il

i l:il E-l ::i H
i

~

8 N

~

E-l ii..

Ul OI

,..:i OI H

u ><

00 g:J ~ ~~

CJ CJ Cl) ice E-l z ii.

A B c D

E 22MS171 2

C2 x

2 GA A

c 3,4 YES 23MS171 2

D2

  • x 2

GA A

c 3,4 YES 24MS171 2

E2 x

2 GA A

c 3,4 YES 21MS168 NONE F3 x

4 3-WAY SOL 3

YES

  • Open to both ports 11 -

14MS169 and 22MS168 NONE E3 x

4 3-WAY SOL 3

YES 11 -

14MS171 23MS168 NONE C3 x

4 3-WAY

  • SOL 3

YES 24MS168 NONE B3 x

4 3-WAY SOL 3

YES

VALVE:

2MS52 CATEGORY:

B CLASS:

2 FUNCTION:

Steam shutoff for the 13AF Pump Turbine to drive the pump.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

This is a passive valve.

It is always in the position required to allow the pump to operate during an indident.

ALTERNATE TESTING:

None.

VALVE:

2MS53 CATEGORY:

B CLASS:

2 FUNCTION:

To regulate the steam flow to the 13AF Pump Turbine t_o maintain a constant pump speed.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

This is a Turbine Governor Valve - stroke time does not provide any data on valve degradation.

ALTERNATE TESTING:

Proper system operation during monthly testing of 23 Auxiliary Feedwater Pump will verify proper valve operation.

VALVE:

21 -

24MS167 (4 Valves)

CATEGORY:

B CLASS:

2 FUNCTION:

Main Stearn Isolation Valves.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation.

Shutting one valve will cause a Stearn Flow/Feed Flow mismatch in the corresponding SG because the Stearn Flow would go to zero.

This would cause a reactor trip.

ALTERNATE TESTING:

These valves will be tested following Cold Shutdown and Refueling per Section XI.

VALVE:

21 -

24MS169 and 21 -

24MS171 (8 Valves)

CATEGORY:

B CLASS:

2 FUNCTION:

Opening these valves is the back-up method of shutting the Main Stearn Stop Valves (MS167 's).

TEST REQUIREMENTS:

Stroke Time Testing each three months.;

Fail Safe Testing each three months.

BASIS FOR RELIEF:

Testing of one of these valves will result in the closure of the corresponding Main Stearn Stop (21 -

24MS167).

See relief for 21 -

24MS167.

ALTERNATE TESTING:

These valves will be tested following Cold SHutdown and Refueling per Section XI.

Page 45 of 95 Rev. 0

VALVE:

21 -

24MS168 CATEGORY:

B CLASS:

NONE e FUNCTION:

Three way valve used to direct steam in the closing of 21 - 24MS167 to vent through 21 - 2 4MS169 and 21 -

24MS171.

TEST REQUIREMENTS:

Stro~e Time Testing each three months.

BASIS FOR RELIEF:

This is a passive valve always maintained in its safety-related position (i.e. open to the MS169s and MS17ls).

ALTERNATE TESTING:

None.

\\

Page 46 of 95 Rev. 0

SYSTEM NITROGEN (NT)

DRAWING NO.

205301 and 205334 PAGE 47 of 95 Rev. 0

(/)

(/)

ril 8

ril

r:

ril z

8 u

c:i..

~

.:i:

z r::i::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

rr.. (/)

(NOT TO BE NUMBER

[/)

fil CATEGORY ril

.:i:

H ril ril USED FOR RELIEF BASIS)

[/)

ril

~~

8 H::::;

j 8

N

~

[/) ()j

,.:i Ol H

u :><

00

~~ ~~

CJ u

Ul

.:i: 8 z c:i..

A B c D

E 2NT25 2

Gl x

0.*75 DA A

c 1,3 YES

<10 sec. Ph. "A" Cont. Isol.

4

/

(Print #205301, RC System) 2NT26 2

G2 x

x 0.75 CK SA c

1,6 YES (Print #205301, RC System) 2NT32 2

G3 x

1 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 (Print #205334, SJ System)

VALVE:

2NT25 CATEGORY:

A CLASS:

3

~

FUNCTION:

Containment Isolation of Nitrogen Supply to Pressurize Relief Tank.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2NT32 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation of Nitrogen Supply to the Safety Injection Accumulators.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technjcal Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2NT26 CATEGORY:

A/C (Check) e CLASS:

2 FUNCTION:

Containment Isolation of Nitrogen Supply to the Pressurizer Relief Tank.

TEST REQUIREMENTS:

Verify valve operability every three months; Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

This valve has no position indication and is located inside the containment.

This valve can only be verified shut during Refueling.

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

Valve operability will be verified per Section XI during Leak Rate *Test at Refueling.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 48 of 95 Rev. 0

SYSTEM REACTOR COOLANT/PRESSURIZER (RC, PR, PS)

DRAWING NO. ~~~~~~~~~~~~

205301 PAGE 49 of 95 Rev. 0 Cl)

Cl)

µ:i E-<

µ:i

r:

µ:i z

E-<

u ii.

~

.:i:

z

~

z VALVE.
z VALVE H

E-<

0 0

~

E-<

REMARKS H

~

E-<

~~

Ii<

Cl)

NUMBER Cl)

CATEGORY

µ:i

.:i:

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

Cl)

µ:i

J µ
i E-< ;:J H
J
s 8

N

~

E-< ii.

Cl) QI

..:l QI H

u ><

00

~~ ~~

u u

Cl)

.:i: E-<

z ii.

A B c D

E 2PR1 1

B2 x

3 PL A

c 3

NO 2PR2 1

B2 x

3 PL A

c 3

NO 2PR3 1

C2 x

6 REL SA c

5 NO 2PR4 1

C2 x

6 REL SA c

5 NO 2PR5 1

C2 x

6 REL SA c

5 NO 2PR6 1

B2 x

3 GA MO 0

3 NO 2PR7 1

B2 x

3 GA MO 0

3 NO 2PR15 2

G6 x

0.75 DIA A

c 2

NO 2PR17 2

G2 x

0.38 PL A

AUTO 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2PR18 2

Gl x

0.38 PL A

AUTO 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2PR25 2

G2 x

4 CK SA c

6 NO 2PR47 1

C2 x

3 PL SOL c

3 NO 2PR48 1

C2 x

3 PL SOL c

3 NO 2PS2 1

B3 x 0.75 GL M

L.TH.

7 NO 2PS4 1

B3 x 0.75 GL M

L.TH.

7 NO

VALVE:

2 PRl 7 and 2 PR18 CATEGORY:

A CLASS:

2

~

FUNCTION:

Containment Isolation Pressurizer Relief Tank to Gas Analyzer Sample Line.

TEST REQUIREMENTS:

Because the safety related function of these valves is containment isolation, they will be leak tested in accordance with Techn~cal Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code, Section Xi for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 50 of 95 Rev. 0

RESIDUAL HEAT REMOVAL (RHR) 20S332 PAGE Sl of 9S Rev. 0 Ul Ul

~

8

~

r:

~

z 8

u 11<

~

~

z p.::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

Ji.. Ul Nl'MBER Ul

~

CATEGORY

~

~

H

~ ~

(NOT TO BE USED FOR RELIEF BASIS)

Ul

~

J ~

8

J H
J j

8 N

~

8 11<

Ul Ol

...:l Ol H

u ><

00

~~ ~~

u u

Ul

~ 8 z 11<

A B c D

E 2RH1 1

DB x

14 GA MO c

3 YES 2RH2 1

D7 x

14 GA MO c

3 YES 2RH3 2

D7 x

3 REL SA c

s NO 21RH4 2

El x

14 GA MO 0

3 NO 22RH4 2

Cl x

14 GA MO 0

3 NO 21RHB 2

E2 x

8 CK SA c

6 YES 22RHB 2

B3 x

8 CK.

SA c

6 YES 21RH12 2

D4 x

8 GA M

LC 7

NO 22RH12 2

B4 x

8 GA M

LC 7

NO 21RH18 2

ES x

8 BFY A

TH 3,4 NO 22RH18 2

BS x

8 BFY A

TH 3,4 NO 21RH19 2

DS x

8 GA MO 0

3 NO 22RH19 2

D6 x

8 GA MO 0

3 NO 2RH20 2

DS x

8 BFY A

c 3,4 NO 2RH2S 2

F7 x

0.7S REL SA c

s NO 2RH26 1

F7 x

12 GA MO c

3 YES 23RH27 1

.F7 x

8 CK SA c

6 YES 24RH27 1

F7 x

8 CK SA c

6 YES 21RH29 2

F3

}

2 GL MO AUTO 3

NO 22RH29 2

B3

}

2 GL MO AUTO 3

NO 21RH36 2

El x

0.7S GL M

LO 7

NO 22RH36 2

Cl x 0.7S GL M

LO 7

NO

SYSTEM.~~-RE_S_I_D_U_AL~_H_E_A_T~RE~M_O_V_AL~__.;.(_RR_R-'-)~~~~~~~

20S332 PAGE S2 of 9S Rev. 0 Ul Ul

µ:i 8

µ:i

r::

µ:i z

8 u

0.

~

-=i:

z IZ z

VALVE z

VALVE H

8 0

0

&l 8

REMARKS H

8

~E rr.. Ul NllMBER Cf)

~

CATEGORY

~

-=i:

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

Ul

µ:i

~ ~

8

i Hp
s 8

N

~

I Cf) QI

,_:i QI H

u ><

00

~~ ~~

u u

Cf)

-=i: 8 z 0.

A B c D

E 21RR37 2

E4 x

0.7S GL M

LO 7

NO 22RR37 2

B4 x

0.7S GL M

LO 7

NO 21RR38 2

E3 x

0.7S GL M

LO 7

NO 22RR38 2

B4 x

0.7S GL M

LO 7

NO 21RR39 2

E4 x

0.7S GL M

LO 7

NO 22RR39 2

B4 x

0.7S GL M

LO 7

NO 21RR40 2

DS x

0.7S GL M

LO 7

NO 22RR40 2

DS x

0.7S GL M

LO 7

NO 2RR41 2

D6 x

0.7S GL M

LO 7

NO 2RR42 2

D7 x

0.7S GL M

LO 7

NO 2RR43 2

D8 x

0.7S GL M

LO 7

NO 21RR10 2

E4 x

8 GA M

LO 7

NO 22RR10 2

B4 x

8 GA M

LO 7

NO 21RR14 2

ES x

8 GA M

LO 7

NO 22RR14 2

BS x

8 GA M

LO 7

NO 2RR21 2

D7 x

8 GA M

LC 7

NO

I I

VALVE:

2RH1 and 2RH2 CATEGORY:

B CLASS:

1 FUNCTION:

Residual Heat Removal pressure isolations from the Hotleg on the #21 Loop.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

These valves cannot be tested during Power Operati0n because they are pressure interlocked and cannot be opened with RCS > 415 psig.

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2RH26 CATEGORY:

B CLASS:

1 FUNCTION:

Residual Heat Isolation from the Hot Legs of the #23 and #24 Loops.

TEST REQUIREMENTS:

Stroke Time Testinq each three months.

BASIS FOR RELIEF:

This valve cannot be exercised during Power Operation because valve is shut with power removed (per Technical Specification 4.5.2) to prevent over-pressurization of the RHR System (low pressure SI System).

Also, if the valve failed open, flow would be diverted from the injection flow path.

ALTERNATE TESTING:

This valve will be tested following Cold Shutdown and Refueling per Section XI.

VALVE:

23RH27 and 24RH27 CATEGORY:

c (Check)

CLASS:

1 FUNCTION:

To prevent Reactor Coolant Backflow into the Residual Heat Removal System.

TEST REQUIREMENTS:

This is a passive valve.

During an incident LPSI is through another path, therefore exercising is not required.

ALTERNATE TESTING:

None.

VALVE:

21RH8 and 22RHB CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent backflow through the RHR (LPSI) pumps.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves can only be part stroke exersiced during Power Operation due to

  • the limited size of the recirc line.

To full stroke exercise these valves at Power Operation requires opening the 1RH21.

Should this valve fail while open or should an incident occur while testing, too much water would be diverted from the LPSI to provide sufficie~t coolinq.

ALTERNATE TESTING:

This valve will be full stroke exercised during Cold Shutdown and Refueling per Section XI.

Page 53 of 95 Rev. 0

SYSTEM~~S_AF

__ E_T_Y;__I_N_J_E_C_T_I_ON ____ ~(S_J~).___ ________ ~~----~ DRAWING NO.

20S334

~--------------------~ PAGE S4 of 9S Rev. 0 U)

U)

µ:i E-t

µ:i

r:

µ:i z

E-t u

11<

~

i:i:

z

>i r::i::

z VALVE z

VALVE H

E-t 0

0

~

E-t REMARKS H

~

E-t

~ ~.

Ii< U)

NUMBER

. U)

§ CATEGORY

µ:i i:i:

H WW (NOT TO BE USED FOR RELIEF BASIS)

U) w

~

~~

E-l :::i H

j 8

N U) ()I

,_:i OI H

u ><

00

~~ ~~

u u

U) i:i: E-t z 11<

A B c D

E 2SJ1 2

B2 x

8 GA MO c

3 YES 2SJ2 2

B2 x

8 GA MO c

3 YES 2SJ3 2

B2 x

8 CK SA c

6 YES 2SJ4 2

C4 x

4 GA MO c

3 YES 2SJS 2

C4 x

4 GA MO c

3 YES 2SJ10 2

D4 x

0.7S REL SA c

s NO 2SJ12 1

cs x

4 GA MO c

3 NO.

2SJ13 1

cs x

4 GA MO c

3 NO 21SJ16 1

B6 x l.S GL M

L.TH.

7 NO 22SJ16 1

B6 x l.S GL M

L.TH.

7 NO 23SJ16 1

B6 x l.S GL M

L.TH.

7 NO 24SJ16 1

B6 x l.S GL M

L.TH.

7 NO 21SJ17 1

B7 x

l.S CK SA c

6 YES 22SJ17 1

B7 x

l.S CK SA c

6 YES 23SJ17 1

B7 x

l.S CK SA c

6 YES 24SJ17 1

B7 x

l.S CK SA c

6 YES 21SJ29 3

F6 x

1 SAF SA c

s NO 22SJ29 3

F7 x

1 SAF SA c

s NO 23SJ29 3

FB x

1 SAF SA c

s NO 24SJ29 3

F9 x

1 SAF SA c

s NO 2SJ30 2

Fl

x 8

GA MO 0

3 YES 2SJ31 2

Fl x

8 CK SA c

6 YES

SYSTEM~~S_AF~E_T_Y~I_N~J_E_C_T_I~O~N~~(S~J"'-'-)~~~~~~~~~~ DRAWING N0.~-2~0~5~3~3~4"'--~~~~~~~ PAGE 55 of 95 Rev. 0 Cl)

Cl) w E-<

w

r:

li'.I z

E-<

u 11<

~

~

z

>i P::

z VALVE z

VALVE H

E-<

0 0

~

E-<

REMARKS H

E-<

~~

r:r..

Cl)

NUMBER Cl)

§ CATEGORY li'.I

~

H li'.I w (NOT TO BE USED FOR RELIEF BASIS)

Cl) w

J w E-l ;
J H
J
'.S 8

N

~

E-l 11<.

Cll OI

...:! OI H

u >i 00

~~ ~~

u u

Cl)

~ E-<

z 11<

A B c D

E 2SJ32 2

F2 x

0.75 REL SA c

5 NO 21SJ33 2

Fl x

6 GA MO 0

3 NO 22SJ33 2

F2 x

6 GA MO 0

3 NO 21SJ34 2

E2 x

4 CK SA c

6 YES 22SJ34 2

E3 x

4 CK SA c

6 YES 21SJ39 2

E4 x

0.75 REL SA c

5 NO 22SJ39 2

E4 x

0.75 REL SA c

5 NO 21SJ40 1

F4 x

4 GA MO c

3 NO 22SJ40 1

F3 x

4 GA MO c

3 NO 21SJ43 1

D6 x

6 CK SA c

6 YES 22SJ43 1

D7 x

6 CK SA c

6 YES 23SJ43 1

D8 x

6 CK SA c

6 YES 24SJ43 1

D9 x

6 CK SA c

6 YES 21SJ44 2

A6 x

14 GA MO c

3 YES 22SJ44 2

A6 x

14 GA MO c

3 YES 21SJ45 2

F3 x

8 GA MO c

3 YES 22SJ45 2

D2 x

8 GA MO c

3 YES 21SJ48 2

G4 x

2 REL SA c

5 NO 22SJ48 2

F4 x

2 REL SA c

5 NO 21SJ49 1

G4 x

8 GA MO 0

3 NO 22SJ49 1

F4 x

8 GA MO 0

3 NO 2SJ53 1

F5 x

0.75 GL A

c i,3 YES

< lOSec. Ph. "A" Cont. Isol.

e e

e SYSTEM SAFETY INJECTION (SJ)

DRAWING NO.

205334 PAGE 56 of 95 ReY* 0 ti) ti) ri:l 8

ri:l

x:

ri:l z

8 u

(1,

~

~

z

>t p:;

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

~ ti)

NtTMBER (Jl

~

CATEGORY ri:l

~

H ri:l ri:l (NOT TO BE USED FOR RELIEF BASIS)

(Jl ri:l

J ri
l 8
J H
J
s 8

N

~

8 (1,

Ul OI

....:JOI H

u :>t 00

~~ ~~

CJ u

(Jl

~ 8 z (1, A

B c D

E 21SJ55 1

E6 x

10 CK SA c

6 YES 22SJ55 1

E7 x

10 CK SA c

6 YES 23SJ55 1

EB x

10 CK SA c

6 YES 24SJ55 1

E9 x

10 CK SA c

6 YES 21SJ56 1

D7 x

10 CK SA c

6 YES 22SJ56 1

DB x

10 CK SA c

6 YES 23SJ56 1

09 x

10 CK SA c

6 YES 24SJ56 1

010 x

10 CK SA c

6 YES 2SJ60 1

E4 x

0.75 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 21SJ64 2

E2 x

0.75 CK SA*

c 6

NO 22SJ64 2

E3 x

0.75 CK SA c

6 NO 2SJ67 2

Dl x

2 GL MO 0

3 NO 2SJ6B 2

Dl x

2 GL MO 0

3 NO 2SJ69 2

Gl x

12 GA MO 0

3 YES 2SJ70 2

Gl x

12 CK SA c

6 YES 2SJ71 2

C4 x

x 1

GL M

LC 1,2 YES 7

2SJ75 2

05 x

1 GL M

LO 7

NO 2SJ7B 2

04 x

1 GL A

0 2

NO 2SJ79 2

04 x

1 GL A

0 2

NO 2SJB7 3

Bl x

3 CK SA c

6 NO 21SJ93 3

F6 x

1 GL A

c 3,4 NO

DRAWING N0.~~~20~5~3~3~4=-~~~~~~~ PAGE 57 of 95 Rev. 0

~

U)

U) w E-t w

r:

w z

E-t u

11<

~

.::i:

z

~

z VALVE z

VALVE H

E-t 0

0

~

E-t REMARKS H

~

E-t

~~

µ, U)

NtTMBER*

U)

~

CATEGORY w

.::i:

H WW (NOT TO BE USED FOR RELIEF BASIS)

U) w

> w E-t :::>

H

~

8 N

~

E-t 11<

Ul OI

...:IOI H

u ><

00

~~ ~~

u u

U)

.::i: E-t z 11<

A B c D

E 22SJ93 3

F7 x

1 GL A

c 3,4 NO 23SJ93 3

FB x

1 GL A

c 3,4 NO 24SJ93 3

pg x

1 GL A

c 3,4 NO 2SJ10B 2

B4 x

1 GL A

0 3,4 NO 21SJ113 2

Dl x

4 GA MO c

3 NO 22SJ113 2

Dl x

4 GA MO c

3 NO 2SJ114 2

D2 x

6 DIA M

LO 7

NO 21SJ116 2

E2 x 0.75 GL M

LO 7

NO 22SJ116 2

C2 x 0.75 GL M

LO 7

NO 2SJ123 1

FS x

0.75 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol 4

21SJ126 3

A6 x 0.75 GL M

LO 7

NO 22SJ126 3

AS x 0.75 GL M

LO 7

NO 21SJ134 2

F4 x

4 GA MO 0

3 NO 22SJ134 2

F4 x

4 GA MO 0

3 NO 2SJ135 1

F4 x

4 GA MO 0

3 YES 21SJ13B 1

GB x

2 GL M

L.TH.

7 NO 22SJ13B 1

GB x

2 GL M

L.TH.

7 NO 23SJ13B 1

G7 x

2 GL M

L.TH.

7 NO 24SJ13B 1

G6 x

2 GL M

L.TH.

7 NO 21SJ139 1

FB x

2 CK SA c

6 YES 22SJ139 1

FB x

2 CK SA c

6 YES

SYSTEM:__ __ S_AF

__ E_T_Y __

I_N_J_E_C_T_I_ON __ _:...(S_J_)'----~--~----------~ DRAWING NO.

205334


=~::....;:..;;:..=...--~--~--~~ PAGE 5.8 of 95 Rev. O U)

U)

µ:i 8

µ:i

r:

µ:i z

8 u

p.,

i:i::

~

~

z z

VALVE z

VALVE H

8 0

0 8

. REMARKS H

~

8

~~

Ii< U)

Nl1MBER U)

~

CATEGORY

µ:i

~

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

U)

µ:i

> µ
i 8

H

s 8

t'J

~

8 p.,

U) QI

,_:i QI H

u ><

00

~~ ~~

~

u U)

~ 8 z p.,

A B c D

E 23SJ139 1

G7 x

2 CK SA c

6 YES 24SJ139 1

GG x

2 CK SA c

6 YES 21SJ143 1

EG x

2 GL M

L.TH.

7 NO 22SJ143 1

E7 x

2 GL M

L.TH.

7 NO 23SJ143 1

EB x

2 GL M

L.TH.

7 NO 24SJ143 1

E9 x

2 GL M

L.TH.

7 NO 21SJ144 1

EG x

2 CK SA c

6 YES 22SJ144 1

E7

/

x 2

CK SA c

6 YES 23SJ144 1

EB \\

x 2

CK SA c

6 YES

  • 24SJ144 1

E9 x

2 CK SA c

6 YES 2SJ150 1

BS x

3 CK SA c

6 YES 21SJ156 1

GB x

6 CK SA c

6 YES 22SJ156 1

GB x

6 CK SA c

6 YES 23SJ156 1

GG x

6 CK SA c

6 YES 24SJ156 1

GG x

6 CK SA c

6 YES 2SJ167 2

p4*

x 0.75 REL SA c

5 NO 21SJ35 2

D3 x

4 GA M

0 7

NO 22SJ35 2:

D5 x

4 GA M

0 7

NO 21SJ54 1

D7 x

10 GA MO 0

3 YES 22SJ54 1

DB x

10 GA MO 0

3 YES 23SJ54 1

D9 x

10 GA MO 0

3 YES 24SJ54 1

DlO x

10 GA MO 0

3 YES

VALVE:

2SJ1 and 2SJ2 CATEGORY:

B CLASS:

2 FUNCTION:

These valves isolate the Refueling Water Storage Tank from the suction of the Charging Pumps.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation without injecting 2000 ppm boron into the RCS resulting in a Reactor Shutdown.

ALTERNf.TE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2SJ3 CATEGORY:

C (Check)

CALSS:

2 FUNCTION:

To prevent backflow of the Volume Control System into the Refueling water Storage Tank.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

In order to test this valve lSJl or 1SJ2 must be opened.

See the specific relief for opening these valves.

ALTERNATE TESTING:

This valve will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2SJ4 and 2SJ5 CATEGORY:

B CLASS:

2 FUNCTION:

Boron Injection Tank inlet valves.

TEST REQUIREMENTS:

Strok Time Testing each three months.

BASIS FOR RELIEF:

Opening these valves during Power Operation would dilute the BIT below 20,100 ppm boron; the concentration required by Technical Specification 3.5.4.1 to insure safe Plant shutdown of the reactor during an incident.

ALTERN~TE TESTING:

These valves will be tested durinq Cold Shutdown and Refueling per Section XI.

VALVE:

21 -

24SJ17 (4 Valves)

CATEGORY:

c (Check)

CLASS:

1 FUNCTION:

To prevent backflow from the RCS Cold Legs into the Safety Injection System.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

a)

For Power Operation, testing would require pumping 2,000 ppm borated water into the RCS.

This would render the Reactor subcritical and would also violate Technical Specification LCO 3.5.4.1.

b)

For Cold Shutdown, testing would ultimately require significant RCS dilution a.nd boric acid recovery operation.

It would also present a possible low-temperature RCS over-pressurization and would violate Technical Specification 3.5.4.1 and certain operating procedures.

ALTERNATE TESTING:

This valve will be tested during Refuelin9 per Section XI.

Page 59 of 95 Rev. 0

VALVE:

2SJ30 CATEGORY:

B CLASS:

2

~

FUNCTION:

Isolate S.I. Pump suctions from the Refueling water Storage Tank.

TEST REQUIREMENTS:

Time Stroke Testing each three months.

BASIS FOR RELIEF:

Stroking this valve requires isolating the suctions of both Safety Injection Pumps from the RWST.

Failure of this valve would disable both ECCS trains and render the Plant in a lesser condition of safety during Power Operation.

ALTERNATE TESTING:

This valve will be tested during Cold SHutdown and Refueling per Section XI.

VALVE:

21SJ34 and 22SJ34 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent backflow through Safety Injection Pumps.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Only partial stroke testing quarterly is possible due to design of the recirculation line.

Flow to Loop cannot be done at Power Operation because the RCS pressure is > Safety Injection Pump Shutoff Head.

ALTERNATE TESTING:

These valves will be part stroke tested quarterly per Section XI.

The method*and frequency for full stroke testinq is still under review.

VALVE:

2SJ31 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent backflow into the RWST and to prevent backflow through Safety Injection Pump.

TEST REQUIREMENT:

Verify valve operability every three months.

BASIS FOR RELIEF:

Only partial stroke testing quarterly is possible due to design of the recirculation line.

Flow to Loop cannot be done at Power Operation because the RCS pressure is > Safety Injection Pump Shutoff Head.

ALTERi~ATE TESTING:

This valve will be part stroke tested quarterly per Section XI.

The method and frequency for full stroke testing is still under review.

VALVE:

21 -

24SJ43 (4 Valves)

CATEGORY:

c (Check)

CLASS:

1 FUNCTION:

To prevent backflow of water from the accumulators to the RHR Discharge Piping.

TEST REQUIREMENTS:

BASIS FOR RELIEF:

ALTERNATE TESTING:

Verify valve operability every three months.

During Power Operation, RCS pressure is greater than RHR Pump Shutoff Head and flow cannot be established.

These valves will be part stroke tested during Cold Shutdown and Refueling per Section XI.

The method and frequency for full stroke testing is still under review.

Page 60 of 95 Rev. 0

VALVE:

21SJ44 and 22SJ44 CATEGORY:

B CLASS:

3 FUNCTION:

Safety Injection System Containment Sump suction valves.

TEST REQUIREMENTS:

Stroke time testing each three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation because if a valve failed, containment integrity would be breached to initiate a repair to the valve and the reactor would have to be shutdown.

ALTERNATE TESTING:

These valves will be tested during Cold SHutdown and Refueling per Section XI.

VALVE:

21 and 22SJ45 CATEGORY:

B CLASS:

2 FUNCTION:

Provide suction from the RHR (LPSI) pump discharge to the Safety Injection (IPSI) and Charging (HPSI) Pumps.

TEST REQUIREMENTS:

Stroke time testing each three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation because the 21 and 22SJ44 must be opened to exercise these valves due to interlocks between them.

See relief request for 21 and 22SJ44.

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

2SJ53 CATEGORY:

A CLASS:

1

~

FUNCTION:

Containment Isolation for Safety Injection Test Line.

TEST REQUIREMENTS-Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Techncial Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

21 -

24SJ55 (4 Valves)

CATEGORY:

C (Check)

CLASS:

1 FUNCTION:

To prevent backflow from the discharge of the RHR pumps into the accumulators.

BASIS FOR RELIEF:

During Power Operation, the RCS pressure is greater than accumulator pressure.

During Cold Shutdown, testing of this valve by accumulator discharge could result in low temperature over-pressurization of the RCS.

ALTERNATE TESTING:

These valves will be part stroke tested during Refueling per Section XI.

The method and frequency for full stroke testing is stil_l under review.

Page 61 of 95 Rev. 0

VALVE:

21 -

24SJ56 (4 Valves)

CATEGORY:

C (Check)

CLASS:

1 FUNCTION:

To prevent backflow from the RCS Cold Legs into the accumulator and RHR Pump Discharge Lines.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Flow cannot be established during Power Operation because the RCS pressure is greater than both the RHR Pump Shutoff Head and the accumulator pressure.

ALTERNATE TESTING:

These valves will be part stroke tested during Cold SHutdown and Refueling when RHR is in service, per Section XI.

The method and frequency for full *stroke testing is still under review.

VALVE:

2SJ60 CATEGORY:

A CLASS:

1 FUNCTION:

Containment Isolation for Safety Injection Test Line.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2SJ69 CATEGORY:

B CLASS:

2 FUNCTION:

Provide suction to the RHR (LPSI) pumps.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

This is a passive valve always maintained in the open position (Technical Specification 4.5.2 requires this valve to b~ open with the power removed during Power Operation).

Failure of this valve in the closed position during testing would render the RHR (LPSI) System inoperable.

ALTERNATE TESTING:

This valve will be tested following Cold Shutdown and Refueling per Section XI.

VALVE:

2SJ70 CATEGORY:

C (Check)

CLASS:

2 FUNCTION:

To prevent b~ckflow from the RHR pump suction to the Refueling Water Storage Tank.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Only part stroke exercise is possible due to limited size of recirculation line.

ALTERN1'.TE TESTING:

This valve will be part stroke_ tested quarterly per Section XI.

The method and frequency for full stroke testing is still under review.

Page 62 of 95 Rev. 0

VALVE:

2SJ23 CATEGORY:

A CLASS:

1 e FUNCTION:

Containment. Isolation for Safety Injection Tank Lines.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves us_ed for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2SJ135 CATEGORY:

B CLASS:

1 FUNCTION:

Safety Injection (IPSI) Pump Discharge to Cold Legs.

TEST REQUIREMENmS:

stroke Time Testing every three months.

BASIS FOR RELIEF:

This valve cannot be exercised during Power Operation because if it fails shut during testing Cold Leg Injection would be isolated placing the Plant in an unsafe condition.

ALTERNATE TESTING:

This valve will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

21 -

24SJ139 (4 Valves)

CATEGORY:

c (Check) e CLASS:

1 FUNCTION:

To prevent backflow from the RCS Hot Legs. to the discharge of the Safety Injection Pumps.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

During Power Operation, testing is not possible _since RCS pressure is greater

.than Safety Injection Pump Shutoff Head.

During Cold Shutdown, the possibility of a Low Temperature Over-Pressurization of the *RCS exists.

ALTERNATE TESTING:

These valves will be part stroke tested during Refueling per Section XI.

The method and frequency for full stroke testing is still under review.

Vi\\LVE:

21 -

24SJ144 (4 Valves)

CATEGORY:

c (Check)

CLASS:

1 FUNCTION:

To prevent backflow from the RCS Cold Leg to the Safety Injection Pump Discharge Lines.

TEST REQUIREMETNS:

BASIS FOR RELIEF:

ALTERNATE TESTING:

Verify valve operability every three months.

During Power Operation testing is not possible since RCS pressure is greater than Safety Injection Pump Shutoff Head.

During Cold Shutdown a low temperature over-pressurization of the RCS could occur.

These valves will be part stroke tested during Refueling per Section XI.

The method and frequency for full stroke testing is still under review.

Page 63 of 95 Rev. 0

VALVE:

2SJ150 CATEGORY:

c (Check)

CLASS:

1

~

FUNCTION:

To prevent backflow from the RCS Cold Legs into the BIT.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

a)

Testing this valve during Power Operation would render the Reactor subcritical and would also violate Technical Specification LCO 3.5.4.1.

b)

For Modes 3 and 4, testing would also ultimately require significant RCS dilution and boric acid recovery and a low temperature over-pressur iza.tion of the RCS could occur.

ALTERNATE TESTING:

This valve will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

21 -

24SJ156 CATEGORY:

C (Check)

CLASS:

1 FUNCTION:

To prevent backflow from the RCS Hot Legs to the Safety Injection Pump Duscharge Lines.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Same conditions for relief as 21 - 24SJ139; see specific relief for those valves.

ALTERNATE*TESTING:

These valves will be part stroke tested during Refueling per Section XI.

The method and frequency for full stroke testing is still under review.

VALVE:

21 -

24SJ54 CATEGORY:

B CLASS:

1 FUNCTION:

Accumulator Outlet to the Cold Legs.

TEST REQUIREMENTS:

Stroke Time Testing each three months.

BASIS FOR RELIEF:

Valves cannot be exercised when the accumulators are at normal pressure and the RCS is <1000 psig to prevent a possible Low Temperature Over-pressuriza-tion of the RCS.

ALTERNATE TESTING:

These valves will be tested when:

a)

The accumulators are at normal pressure and RCS >1000 psig.

b)

The accumulators are depressurized and the RCS is <1000 psig.

Page 64 of 95 Rev. 0

VALVE:

2SJ71 CATEGORY:

B CLASS:

2

~ FUNCTION:

Safety Injection System Flushing Connection.

TEST REQUIREMENTS:

a)

Valve exercising each 3 months.

b)

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF,:

a) b)

Passive valve not required to change position to fuliill its safety function.

Valve is locked shut per Technical Specification 3.6.3.1, Table

3. 6-1.

Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.*

ALTERNATE TESTING:

a)

None.

b)

None.

Page 65 of 95 Rev. 0

DRAWING NO.

25344/240668

~~~~"'--~~~~~~~~ PAGE 66 of 95 Rev. 0 U)

U)

µ:i E-<

ll:'.l

r:

ll:'.l z

E-<

u tl.<

~

z

>i p::

z VALVE z

VALVE H

E-<

0 0

gJ E-<

REMARKS H

E-<

~*~

rz..

U)

NUMBER U)

~

CATEGORY ll:'.l H

ll:'.l rLl (NOT TO BE USED FOR RELIEF BASIS)

U) ll:'.l

J ll
'.l 8
J H
J
s 8

N

~

E-<

tl.<

U) QI

....:i QI H

u >i 00

~ gJ gJ gJ CJ u

U)

,ct; 8 z A<

A B

c D

E 2SS27 2

E7 x

0.38 PL A

c 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4 2SS33 2

F7 x

0.38 PL A

c 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4 2SS49 2

G7 x

0.38 PL A

c 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4 2SS64 2

G7 x

0.38 PL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 21SS93 2

D7 x

0.38 GL A

0 1,3 YES 4

22SS93 2

C7 x

0.38 GL A

0 1,3, YES 4

23SS93 2

B7 x

0.38 GL A

0 1,3 YES 4

24SS93 2

A7 x

0.38 GL A

0 1,3, YES 4

21SS94 2

D7 x

0.50 GL A

0 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4 22SS94 2

C7 x

0.50 GL A

0 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4 23SS94 2

B7 x

0.50 GL A

0 1,3, YES

<10 Sec. Ph. "A" cont. Isol.

4 24SS94 2

B7 x

0.50 GL A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2SS103 2

E7 x

0.38 PL A

c 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4

DRAWING NO.

205344/240668 PAGE 67 of 95 Rev. 0 U)

Cl) lil 8

lil

c ll:l z

8 u

p.,

~

.ci:

z

>t 0::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

rr..

Cl)

NP MB ER Cl)

§!

CATEGORY ll:l

.ci:

H lil ll:l (NOT TO BE USED FOR RELIEF BASIS)

Cl) lil

~~

8 H

j 8

N

~

U) Ol

...:l Ol H

u >t 00

~~ ~~

u u

Cl)

.ci: 8 z p.,

A B c D

E 2SS104 2

F7 x

0.38 PL A

c 1,3, YES

<10 ~sec. Ph. "A" Cont. Isol.

4 2SS107 2

G7 x

0.38 PL A

c 1,3, YES

<10 Sec.

Ph. "A" Cont. I sol.

4 2SS110 2

G7 x

0.38 PL A

c 1,3, YES

<10 Sec. Ph. "A" Cont. Isol.

4 2SS900 1

B4 x

x 0.12 NE M

LC 1,2, YES Print #240668 7

2SS901 1

B4 x

x 0.12 NE M

LC 1,2, YES Print #240668 7

VALVE:

2SS27, 2SS33, 2SS49 and 2SS64 CATEGORY:

A CLASS:

2 e FUNCTION:

Containment Isolation Primary System Sampling System.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:* Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

21 -

24SS94 (4 Valves)

CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Steam G~nerator Drain and Blowdown.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2SS103, 2SS104, 2SS107 and 2SS110 CATEGORY:

A e CLASS:

2 FUNCTION:

Containment Isolation Primary System Sampling System.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Beacuse the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2SS900 and 2SS901 CATEGORY:

A/E CLASS:

1 FUNCTION:

Containment Isolation for Pressurizer Dead Weight Test.

TEST REQUIREMENTS:

a) b)

Valve exercising each 3 months.

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

a)

Passive valve not required to change position to fulfill its safety function.

Valve is kept locked closed per Technical Specification 3.6.3.2.d, Table 3.6-1.

e ALTERNATE TESTING:

b)

Technical Specification Table 3.6-1 exempts these valves from Leak Rate Testing.

None.

Page 68 of 95 Rev. 0

I-VALVE:

11 -

14SS93 (4 Valves)

CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation from Steam Generator Sampling Lines.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Technical Specification Table 3.6-1 exempts this valve from leak rate testing.

ALTERNATE TESTING:

None.

Page 69 of 95 Rev. 0

e e

e SYSTEM SERVICE WATER -

NUC.

(SW)

DRAWING NO.

205342 PAGE 70 of 95 Rev. 0

~~~~~~~~~~~~

~

U)

U) ri:i E-1 ri:i

r:

µ:i z

E-1 u

p,

~

<:i:

z 0::

z VALVE z

VALVE H

E-1 0

0

~

E-1 REMARKS H

~

E-1

~~

µ.,

U)

NUMBER

(/)

~

CATEGORY

~

<:i:

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

U)

µ:i p

µ:i E-1 :::>

HO

~

8 N

~

E-1 p, U) QI

...:I QI H

u ><

00

~~ ~~

u u

U)

<:i:

E-1 z p, A

B c D

E 21SW2 3

A3 x

20 DCK SA.

0 6

NO 22SW2 3

B3 x

20 DCK SA 0

6 NO 23SW2 3

B3 x

20 DCK SA 0

6 NO 24SW2 3

D3 x

20 DCK SA 0

6 NO 25SW2 3

E3 x

20 DCK SA 0

6 NO 26SW2 3

E3 x

20 DCK SA 0

6 NO 21SW5 3

A3 x

30 DCK SA 0

6 NO 22SW5 3

B3 x

24 DCK SA 0

6 NO 23SW5 3

B3 x

30 DCK SA 0

6 NO 24SW5 3

E3 x

24 DCK SA 0

6 NO 21SW13 3

A2 x

0.75 CK SA 0

6 NO 22SW13 3

B2 x

0.75 CK SA 0

6 NO 23SW13 3

B2 x

0.75 CK SA 0

6 NO 24SW13 3

02 x

0.75 CK SA 0

6 NO 25SW13 3

E2 x

0.75 CK SA 0

6 NO 26SW13 3

E2 x

0.75 CK SA 0

6 NO 21SW15 3

Al x

2 GL A

AUTO 2

NO 22SW15 3

Bl x

2 GL A

AUTO 2

NO 23SW15 3

Bl x

2 GL A

AUTO 2

NO 24SW15 3

Dl x

2 GL A

AUTO 2

NO 25SW15 3

E,l x

2 GL A

AUTO 2

NO 26SW15 3

El x

2 GL A

AUTO 2

NO

e e

e SYSTEM SERVICE WATER -

NUC.

(SW)

DRAWING N0.~___..:2~0~5~3~4~2:_._~~~~~~ PAGE 71 of 95 Rev. 0 Cl)

Cl)

µ:i E-t

µ:i

r:

µ:i z

E-t 0

p.,

~

.:i:

z i:i::

z VALVE z

VALVE H

E-t 0

0

~

E-t REMARKS H

E-t

~~

Ii.. Cl)

NUMBER Cl)

[il CATEGORY

µ:i

.:i:

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

Cl)

µ:i

~ re E-t ::::>

H

~

8 t'l

~

Cl) QI

..:I QI H

~*~

00

~~ ~~

CJ 0

Cl) z p.,

A B c D

E 21SW17 3

B3 x

30 BFY MO 0

3 NO 22SW17 3

D3 x

30 BFY MO 0

3 NO 22SW20 3

B3 x

24 BFY MO 0

3 NO 24SW20 3

E3 x

24 BFY MO 0

3 NO 21SW21 3

G6 x

8 BFY MO 0

3 NO 22SW21 3

G6 x

8 BFY MO 0

3 NO 21SW22 3

G6 x

24 BFY MO 0

3 NO 22SW22 3

G6 x

24 BFY MO 0

3 NO 21SW23 3

G6 x

24 BFY MO 0

3 NO 22SW23 3

G6 x

24 BFY MO 0

3 NO 21SW24 3

A2 x

4 GA A

AUTO 2

NO 22SW24 3

B2 x

4 GA A

AUTO 2

NO 23SW24 3

B2 x

4 GA A

AUTO 2

NO 24SW24 3

D2 x

4 GA A.

AUTO 2

NO 25SW24 3

E2 x

4 GA A

AUTO 2

NO 26SW24 3

E2 x

4 GA A

AUTO 2

NO 2SW28 3

A4 x

3 GL A

AUTO 2

NO 21SW34 3

G7 x

6 DCK SA c

6 NO 22SW34 3

G7 x

6 DCK SA c

6 NO 21SW36 3

G7 x

6 DCK SA c

6 NO 22SW36 3

G7 x

6 DCK SA c

6 NO 21SW38 3

F7 x

6 DCK SA c

6 NO

DRAWING NO.

205342

~~~-=--~~~~~~~~ PAGE 72 of 95 Rev. 0

~

U)

U)

J:il 8

J:il

r::

J:il z

8 u

A.

~

.::i:

z P::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

rr..

U)

NP MB ER Cl)

[ii CATEGORY J:il

.::i:

H J:il J:il (NOT TO BE USED FOR RELIEF BASIS)

U)

J:il

i J:il 8
i H ::J
s 8

N

~

8 A.

U) Ol

...:I Ol H

u ><

00

~~ ~~

tJ tJ U)

.::i: 8 z A.

A B c D

E 22SW38 3

F7 x

6 DCK SA c

6 NO 21SW39 3

G7 x

6 PL A

c 3,4 NO 22SW39 3

G7 x

6 PL A

c 3,4 NO 23SW39 3

G7 x

6 PL A

c 3,4 NO 21SW42 3

. G9 x

6 BFY M

c 7

NO 22SW42 3

G9 x

6 BFY M

c 7

NO 23SW42 3

F9 x

6 BFY M

.. c 7

NO 21SW44 3

G9 x

6 DCK SA c

6 NO 22SW44 3

G9 x

6 DCK SA c

6 NO 23SW44 3

F9 x

6 DCK SA c

6 NO 21SW47 3

G9 x

8 DCK SA c

6 NO 22SW47 3

G9 x

8 DCK SA c

6 NO 21SW49 3

FB x

8 PL A

AUTO

) 2 NO 22SW49 3

F9 x

8 PL A

AUTO 2

NO 21SW51 3

F6 x

16 DCK SA 0

6 YES 22SW51 3

C6 x

16 DCK SA 0

6 YES 21SW52 3

E6 x

16 BFY M

LO 7

NO 22SW52 3

E6 x

16 BFY M

LO 7

NO 21SW53 3

E6 x

10.

DCK SA 0

6 NO 22SW53 3

D6 x

10 DCK SA 0

6 NO 21SW57 3

F7 x

10 BFY A

0 2

NO 22SW57 3

E7 x

10 BFY A.

0 2

NO

e e

e SYSTEM SERVICE WATER -

NUC.

(SW)

DRAWING NO.

205342 PAGE 73 of 95 Rev. 0 Ul Ul

µ:i 8

µ:i

r:

µ:i z

8 u

p.,

~

.:i:

z 0::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

r.r.. Ul Nl1MBER Ul

~

CATEGORY

µ:i

.:i:

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

Ul

µ:i

~~

8 H

s 8

N

~

Ul Qi H Qi H

u ><

00

~~ ~~

u u

Ul

.:i: 8 z p.,

A B c D

E 23SW57 3

E7 x

10 BFY A

0 2

NO 24SW57 3

D7 x

10 BFY A

0 2

NO 25SW57 3

D7 x

10 BFY A

0 2

NO 21SW5B 2

F7 x

10 BFY A

0 3,4 NO 22SW5B 2,..

E7 x

10 BFY A

0 3,4 NO 23SW5B 2

E7 x

10 BFY A

0 3,4 NO 24SW5B 2

D7 x

10 BFY A

0 3,4. NO 25SW5B 2

D7 x

10 BFY A

0 3,4 NO 21SW65 3

FB x

10 BFY A

AUTO*

2 NO 22SW65 3

EB x

10 BFY A

AUTO 2

NO 23SW65 3

EB x

10 BFY A

AUTO 2

NO 24SW65 3

DB x

10 BFY A

AUTO 2

NO 25SW65 3

DB x

10 BFY A

AUTO 2

NO 21SW72 2

F9 x

10 BFY A

0 3,4 NO 22SW72 2

E9 x

10 BFY A

0 3,4 NO 23SW72 2

E9 x

10 BFY A

0 3,4 NO 24SW72 2

D9 x

10 BFY A

0 3,4 NO 25SW72 2

D9 x

10 BFY A

0 3,4 NO 21SW77 3

E9 x

10 DCK SA 0

6 NO 22SW77 3

D9 x

10 DCK SA 0

6 NO 21SW7B 3

E9 x

10 BFY M

LO 7

NO 22SW7B 3

F9 x

10 BFY M

LO 7

NO

SYSTEM _____

s_E_R_V_I_C_E_W_A_T_E_R ___ -__ NU

__ c_. ___

(_s_w~>--------------~ DRAWING NO.

205342


~ PAGE 74 of 95 Rev. 0 en Cl) w 8

w

r:

w z

8 u

11<

~

.::i:

z

>t fl'.!

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

µ_,

Cl)

Nl'MBER Cl)

~

CATEGORY w

.::i:

H w w (NOT TO BE USED FOR RELIEF BASIS)

Cl) w

~~

8~ H

~

j 8

N

~

en OI

,_:i 01 H

u >t 00

~~ ~~

u u

en

.::i: 8 z 11<

A B c D E 21SW79 3

G9 x

24 DCK SA 0

6 YES 22SW79 3

F9 x

24 DCK SA 0

6 YES 21SW92 3

C6 x

4 GL A

AUTO 3

NO 22SW92 3

B6 x

4 GL A

AUTO 3

NO 23SW92 3

B6 x

4 GL A

AUTO 3

NO 21SW93 3

C9 x

4 GL A

AUTO 2

NO 22SW93 3

B9 x

4 GL A

AUTO 2

NO 23SW93 3

B9 x

4 GL A

AUTO 2

NO 21SW99 3

BB x

4 DCK SA 0

6 NO 22SW99 3

BB x

4 DCK SA 0

6 NO 23SW99 3

AB x

4 DCK SA 0

6 NO_

21SW102 3

C9 x

4 PL A

LO 7

NO 22SW102 3

B9 x

4 PL A

LO 7

NO 23SW102 3

B9 x

4 PL A

LO 7

NO 2SW103 3

C9 x

4 DIA M

LO 7

NO 21SW122 3

D5 x

20 BFY A

TH 3,4 NO 22SW122 3

D5 x

20 BFY A

TH 3,4 NO 21SW127 3

D4 x

20 BFY M

LO 7

NO 22SW127 3

D4 x

20 BFY M

LO 7

NO 21SW129 3

D5 x

1.5 GL A

AUTO 3,4 NO 22SW129 3

E5 x

2 GL A

AUTO 3,4 NO 21SW134 3

E4 x

1.5 DIA M

L.TH.

7 NO

DRAWING NO.

20S342

~~__;:::;..;;...:....::.....:~~~~~~~ PAGE 7S of 9S Rev. 0

(/)

(/)

w 8

w

r:

w z

8 u

ill

~

<l; z

~

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

f:-i

~~

r... (/)

NP MB ER Cl)

~

CATEGORY w

<l; H

w w (NOT TO BE USED FOR RELIEF BASIS)

Cl) w

~ ~

8 H

j 8

N

~

Ul OI i-:1 OI H

u ><

00

~~ ~~

u u

Cl)

<l; 8 z ill A

B c D

E 22SW134 3

D4 x

2 DIA M

L.TH.

7 NO 2SW137 3

ES x

2 GL A

AUTO 3,4 NO 2SW142 3

E4 x

2 DIA M

L.TH.

7 NO 21SW14S 3

FS x

l.S GL A

AUTO 3,4 NO 22SW14S 3

AS x

l.S GL A

AUTO 3,4 NO 21SW1SO 3

F4 x

l.S DIA M

L.TH.

7 NO 22SW1SO 3

A4 x

l.S DIA M

L.TH.

7 NO 21SW1S3 3

GS x

l.S GA A

AUTO 3,4 NO 22SW1S3 3

cs x

l.S GA A

AUTO 3,4 NO 21SW1S8 3

G4 x

l.S DIA M

L.TH.

7 NO 22SW1S8 3

C4 x

l.S DIA M

L.TH.

7 NO 2SW163 3

GS x

l.S GL A

AUTO 3,4 NO 2SW168 3

G4 x

1 DIA M

L.TH.

7 NO 2SW169 3

BS x

l.S GL A

AUTO 3,4 NO 2SW174 3

B4 x

1 DIA M

L.TH.

7 NO 2SW17S 3

AS x

2 GL A

AUTO 3,4 NO 2SW180 3

A4 x

2 DIA M

L.TH.

7 NO 2SW18S 3

cs x

l.S GL A

AUTO 3,4 NO 2SW190 3

C4 x

l.S DIA M

L.TH 7

NO 2SW191 3

BS x

2 GL A

AUTO 3,4 NO 2SW196 3

B4 x

l.S DIA M

L.TH 7

NO 2SW199 3

FS x

l.S GA A

AUTO 3,4 NO

e e

SYSTEM SERVICE WATER -

NUC.

(SW)

DRAWING NO..

205342 PAGE 76 of 95 Rey. 0

~

(/)

(/)

w 8

w

r:

w z

8 u

p.,

~

.:x:

z p:;

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

Ii< (/)

NP MB ER

(/)

5l CATEGORY w

ici:

H w w (NOT TO BE USED FOR RELIEF BASIS)

(/)

w

~~

8

J H
J

~

8 N

~

(/) QI H QI H

u :><

00 g:J ~ ~~

u u

(/)

ici: 8 z p.,

A B c D

E 2SW204 3

F4 x

1.5 DIA M

L.TH.

7 NO 2SW205 3

FS x

2 GL A

AUTO 3,4 NO 2SW210 3

F4 x

1.5 DIA M

L.TH.

7 NO 2SW213 3

AS x

1.5 GL A

AUTO 3,4 NO 2SW218 3

A4 x

1.5 DIA M

L.TH.

7 NO 21SW223 3

F9 x

10 PL A

AUTO 2

NO 22SW223 3

E9 x

10 PL A

AUTO 2

NO 23SW223 3

E9 x

10 PL A

AUTO 2

NO 24SW223 3

D9 x

10 PL A

AUTO 2

NO 25SW223 3

D9 x

10 PL A

AUTO 2

NO 21SW305 3

F8 x

8 PL A

AUTO 2

NO 22SW305 3

F8 x

8 PL A

AUTO 2

NO 21SW1 3

B2 x

20 BFY M

LO 7

NO 22SW1 3

B2 x

20 BFY M

LO 7

NO 23SW1 3

C2 x

20 BFY M

LO 7

NO 24SW1 3

E2 I

x 20 BFY M

LO 7

NO 25SW1 3

E2 x

20 BFY M

LO 7

NO 26SW1 3

F2 x

20 BFY M

LO 7

NO 21SW3 3

B2 x

20 BFY M

LO 7

NO 22SW3 3

B2 x

20 BFY M

LO 7

NO 23SW3 3

C2 x

20 BFY M

LO 7

NO 24SW3 3

E2 x

20 BFY M

LO 7

NO

e e

e

.SYSTEM SERVICE WATER -

NUC.

(SW)

DRAWING NO.

205342

~~~~~~~~~~~~ PAGE 77 of 95 Rev. 0 Ul Ul

µ.i 8

µ.i

r:

µ.i z

8 u

0.

~

.:i:

z

>i i:r:

z VALVE z

VALVE H

8 0

0 gJ 8

REMARKS H

~

8

~~

µ.. Ul NlTMBER U)

~

CATEGORY

µ.i

.:i:

H

µ.i µ.i (NOT TO BE USED FOR RELIEF BASIS)

Ul

µ.i

~~

8

i H
J

~

8 N

~*

Ul Ol

....:I Ol H

u >i 00

~~ gJ ~

u u

Ul

.:i: 8 z 0.

A B c D

E 25SW3 3

E2 x

20 BFY M

LO 7

NO 26SW3 3

F2 x

20 BFY M

LO 7

NO 21SW9 3

B2 x

1.5 DIA M

LO 7

NO 22SW9 3

E2 x

1.5 DIA M

LO 7

NO 21SW33 3

G7 x

6 BFY M

LO 7

NO 22SW33 3

G7 x

6 BFY M

LO 7

NO 21SW35 3

G7 x

6 BFY M

LO 7

NO 22SW35 3

G7 x

6 BFY M

LO 7

NO 21SW37 3

G7 x

6 BFY M

LO 7

NO 22SW37 3

G7 x

6 BFY M

LO 7

NO 21SW45 3

G9 x

6 BFY M

LO 7

NO 22SW45 3

G9 x

6 BFY M

LO 7

NO 23SW45 3

G9 x

6 BFY M

LO 7

NO 21SW46 3

G9 x

6 BFY M

LO 7

NO 22SW46 3

G9 x

6 BFY M

LO 7

NO 23SW46 3

G9 x

6 BFY M

LO 7

NO 21SW50 3

F9 x

8 BFY M

LO 7

NO 22SW50 3

F9 x

8 BFY M

LO 7

NO 21SW52 3

E6 x

10 BFY M

LO 7

NO 22SW52 3

E6 x

10 BFY M

LO 7

NO 21SW54 3

F6 x

10 BFY M

LO 7

NO 22SW54 3

F6 x

10 BFY M

LO 7

NO

e e

e SYSTEM SERVICE WATER -

NUC.

(SW)

DRAWING NO.

205342 PAGE 7B of 95 Rev. 0 U)

U) ril 8

ril

r:

ril z

8 u

p.,

~

~

z P::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

8

~~

ri. U)

Nl1MBER Cl)

~

CATEGORY ril

~

H ILi ILi (NOT TO BE USED FOR RELIEF BASIS)

U) ril

~~

8 H

'.§ 8

N

~

U) Ol

...:l Ol H

u ><

00

~~ ~~

u u

U)

~ 8 z p.,

A B c D

E 23SW54 3

E6 x

10 BFY M

LO 7

NO 24SW54 3

E6 x

10 BFY M

LO 7

NO 25SW54 3

D6 x

10 BFY M

LO 7

NO 21SW60 2

FB x

10 BFY M

L.TH.

7 NO 22SW60 2

FB x

10 BFY M

L.TH.

7 NO 23SW60 2

EB x

10 BFY M

L.TH.

7 NO 24SW60 2

EB x

10 BFY M

L.TH.

7 NO 25SW60 2

DB x

10 BFY M

L.TH.

7 NO 21SW66 3

FB x

2 DIA M

LO 7

NO 22SW66 3

EB x

2 DIA M

LO 7

NO 23SW66 3

EB x

2 DIA M

LO 7

NO 24SW66 3

DB x

2 DIA M

LO 7

NO 25SW66 3

DB x

2 DIA M

LO 7

NO 21SW71 3

F9 x

2 DIA M

LO 7

NO 22SW71 3

E9 x

2 DIA M

LO 7

NO 23SW71 3

E9 x

2 DIA M

LO 7

NO 24SW71 3

D9 x

2 DIA M

LO 7

NO 25SW71 3

D9 x

2 DIA M

LO 7

NO 21SW76 3

FlO x

10 BFY M

LO 7

NO 22SW76 3

FlO x

10 BFY M

LO 7

NO 23sw76 3

ElO x

10 BFY M

LO 7

NO 24SW76 3

DlO x

10 BFY M

LO 7

NO 25SW76 3

DlO x

10 BFY M

LO 7

NO

DRAWING N0.~__..2~0~5~3~4~2.___~~~~~~~ PAGE 79 of 95 Rev. 0 (I)

(I)

µ:i 8

µ:i

r:

µ:i z

E-<

u

11.

~

.:i:

z

~

z VALVE z

VALVE H

E-<

0 0

gJ E-<

REMARKS H

~

E-<

~~

Ii< (I)

Nl'MBER (I)

§ CATEGORY

. µ:i

.:i:

H

µ:i µ:i (NOT TO BE USED FOR RELIEF BASIS)

(I)

µ:i

~~

8

J H
J j

8 N

1 (I) QI

...:I QI H

u :><

00

~ gJ

~~

(.)

(.)

en

.:i: E-<

z 11.

A B c D

E 21SW90 3

E6 x

4 DIA M

LO 7

NO 22SW90 3

C6 x

4 DIA M

LO 7

NO 21SW91 3

C6 x

4 DIA M

LO 7

NO 22SW91 3

C6 x

4 DIA M

LO 7

NO 23SW91 3

B6 x

4 DIA M

LO 7

NO 21SW102 3

ClO x

4 DIA M

LO 7

NO 22SW102 3

ClO x

4 DIA M

LO 7

NO 23SW102 3

BlO x

4 DIA M

LO 7

NO 2SW103 3

ClO x

4 DIA M

LO 7

NO 2SW120 3

B9 x

4 DIA M

LO 7

NO 21SW121 3

E6 x

20 BFY M

LO 7

NO 22SW121 3

E6 x

20 BFY M

LO 7

NO

/

21SW127 3

E4 x

20 BFY M

L.TH.

7 NO 22SW127 3

E4 x

20 BFY M

L.TH.

7 NO 21SW128 3

E6 x

1.5 DIA M

LO 7

NO 22SW128 3

D6 x

2 DIA M

LO 7

NO 21SW134 3

E4 x

1.5 DIA M

L.TH.

7 NO 22SW134 3

D4 x

2 DIA M

L.TH.

7 NO 21SW135 3

E4 x

1.5 DIA M

LO 7

NO 22SW135 3

D4 x

2 DIA

NO 2SW136 3

E6 x

2 DIA M

LO 7

NO 2SW142 3

E4 x

2 DIA M

LO 7

NO

SYSTEM;..._ ______

S_E_R_V_I_C_E_W_A_T_E_R __ -__ NU

__ C_. __ ~(_S_W~) ____________ __

205342 PAGE 80 of 95 Rev. 0

~

Ul Ul J:il 8

J:il

r:

J:il

z; 8

u p.,

~

ici:

z

>t ll::

z VALVE z

VALVE H

8 0

0 gJ 8

REMARKS H

8

~~

r... Ul Nl'MBER CJ) fi CATEGORY J:il ici:

H J:il J:il (NOT TO BE USED FOR RELIEF BASIS)

Ul J:il

~~

8 :J H :J

s 8

N

~

Ul QI

,_:i QI H

u :>t 00

~ gJ gJ ~

u u

Ul ici: 8 z p.,

A B c D E 2SW143 3

E4 x

2 DIA M

LO 7

NO 21SW144 3

F6 x

1.5 DIA M

LO 7

NO 22SW144 3

B6 x

1.5 DIA M

LO 7

NO 21SW150 3

F4 x

1.5 DIA M

L.TH.

7 NO 22SW150 3

B4 x

1.5 DIA M

L.TH.

7 NO 21SW151 3*

F4 x

1.5 DIA M

LO 7

NO 22SW151 3

B4 x

1.5 DIA M

LO 7

NO 21SW152 3

G6 x

1.5 DIA M

LO 7

NO 22SW152 3

D6 x

1.5 DIA M

LO 7

NO 21SW159

' 3 G4 x

1.5 DIA M

LO 7

NO 22SW159 3

D4 x

1.5 DIA M

LO 7

NO 2SW160 3

B6 x

2 DIA M

LO 7

NO 2SW162 3

F6 x

3 DIA M

LO 7

NO 2SW168 3

G4 x

1.5 DIA M

L.TH.

7 NO 2SW174 3

C4 x

1.5 DIA M

L.TH.

7 NO 2SW180 3

B4 x

2 DIA M

L.TH.

7 NO 2SW181 3

F4 x

3 DIA M

LO 7

NO 2SW184 3

C6 x

2 DIA M

LO 7

NO 2SW197 3

C4 x

2 DIA M

LO 7

NO 2SW198 3

F6 x

1.5 DIA M

LO 7

NO 2SW211 3

F4 x

2 DIA M

LO 7

NO 2SW220 3

B4 x

2 DIA M

LO 7

NO

SYSTEM ____ ~S~E~R~V~I~C~E~W~A~T~E~R'----N~U~C~.--~(S~W~)'--------------~ DRAWING NO.

205342


~

PAGE 81 of 95 Rev. 0 CJ)

CJ)

µ:i 8

lil

r:

µ:i z

8 u

p..

~

.:i:

z

~

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

8

~~

rr..

CJ)

NUMBER CJ) 5l CATEGORY

µ:i

~~

H lil lil (NOT TO BE USED FOR RELIEF BASIS)

CJ)

µ:i E-1 H

~

8 N

~

CJ) QI

,_:i QI H

u :><

00

~~ ~~

u u

CJ)

~ E-1 z p..

A B c D

E 2SW308 3

Bl x

8 PL A

AUTO 3

NO 2SW311 3

Gl x

8 PL A

AUTO 3

NO

VALVE:

2lSW51 and 22SW51 CATEGORY:

c (Check)

CLASS:

3 FUNCTION:

To prevent backflow from the Containment Fan Coil Units into the Nuclear Service Water Header.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

Testing these valves requires isolating service water to 2 Fan Coil Units.

This places the Plant in a limiting condition for operation (Technical Specification 3.6.2.3).

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

VALVE:

21SW79 and 22SW79 CATEGORY:

C (Check)

CLASS:

3 FUNCTION:

Service Water over-load discharge check valves.

TEST REQUIREMENTS:

Verify valve operability every three months.

BASIS FOR RELIEF:

These valves cannot be exercised during Power Operation because both Nuclear Headers are required (Technical Specification 3.7.4.1).

If the valve were to fail shut the Plant would have to shutdown.

ALTERNATE TESTING:

These valves will be tested during Cold Shutdown and Refueling per Section XI.

Page 82 of 95 Rev. 0

DRAWING N0.~_2_0~5~3~3~3'----~~~~~~~ PAGE 83 of 95 Rev. 0

~

en en

µ:i E-t

µ:i

r:

µ:i z

E-t u

p.,

~

.:i:

z

>t 0::

z VALVE z

VALVE H

E-t 0

0

~

E-t REMARKS H

~

E-t

~~

Ii< en Nl'MBER Cl)

~

CATEGORY

µ:i

..i::

H ril ril (NOT TO BE USED FOR RELIEF BASIS) en ril

~ re E-t D HD

s 8

t'J

~

en Ol

....:l Ol H

u >t 00

~~ ~~

u u

en

..i:: E-t z p.,

A B c D

E 2SF22 2

Bl x

x 3

DIA M

LC 1,3 YES 7

2SF36 2

A2 x

x 2

DIA M

LC 1,3 YES 7

VALVE:

2SF22 and 2SF36 CATEGORY:

A/E CLASS:

2 e FUNCTION:

Containment Isolation (outside containment) of Spent Fuel Cooling Lines to Reactor Cavity.

TEST REQUIREMENTS:

a)

Valve exercising every three months.

b)

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

a)

Passive valve not required to change position to fulfill its safety function.

Valve is kept locked closed per Technical Specification 3.6.3.1, Table 3.6-1.

b)

Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing.

ALTERNATE TESTING:

a)

None.

b)

None.

Page 84 of 95 Rev. 0

SYSTEM~~S_T_A_T_I_O_N~A_I_R~(_C_OMP~RE~s_s_E_D~A_I_R_)~_(_S_A_)~~~~~ DRAWING N0.~~2_0_5_3_1_7~~~~~~~~

85 of 95 Rev. 0

[/)

[/)

ll:'.l 8

ll:'.l

r::

ll:'.l z

~

u r:i..

~

VALVE z

0::

z VALVE H

8 0

0

~

8 REMARKS H

~

8

~~

r:r.. [/)

NUMBER ti)

~

CATEGORY ll:'.l

.:i::

H ll:'.l ll:'.l (NOT TO BE USED FOR RELIEF BASIS)

[/)

ll:'.l

> ll:'.l 8

H

§ 0

N

~

8 r:i..

I ti) Ol

....:I Ol 0

H u :><

00

~~ ~~

u u

[/)

.:i:: 8 z r:i..

A B c D E 2SA118 2

B6 x

x 3

GA M

LC 1,3 YES 7

VALVE:*

2SA118 CATEGORY:

A/E CLASS:

2 FUNCTION:

Containment Isolation of Station Air System.

TEST REQUIREMENTS:

a)

Valve exercising every three months.

b)

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

a)

Passive valve not required to change position to fulfill its safety function.

Valve is locked closed per Technical Specification 3.6.3.1, Table 3. 6-1.

b)

Technical Specification Table 3.6-1 exempts this valve from Leak Rate Testing ALTERNATE TESTING:

a)

None b)

None.

Page 86 of 95 Rev. 0

SYSTEM:__~VE_;;_;_N~T_I_LA~TI_O_N~C_O_N_T_A_I_NME~N_T~_<~v_c_>~~~~~~~

205338 PAGE 87 of 95 Rev. 0

~~~~~~~~~~-

Ul Ul ll:l E-t ll:l

i::

ll:l z

E-t u

Pl

~

.:i:

z

~

z VALVE z

VALVE H

E-t 0

0

~

E-t REMARKS H

~

E-t

~~

r:r.. Ul NUMBER Ul 5l CATEGORY

~

~ re H

ll:l ll:l (NOT TO BE USED FOR RELIEF BASIS)

Ul ll:l E-t !:)

H

!:)

§ 8

N Ul QI H QI H

u ><

00

~~ *~ ~

u u

Ul

.:i: E-t z Pl A

B c

D E

2VC1 2

El x

36 BFY A

c 1,3 YES

<2 Sec. Cont. Purge 4

2VC2 2

El x

36 BFY A

c 1,3 YES 2VC3 2

E2 x

36 BFY A

c 1,3 YES 4

2VC4 2

El x

36 BFY A

c 1,3 YES

<2 Sec. Cont. Purge 4

2VC5 2

Dl x

10 BFY A

c 1,3 YES

<2 Sec. Cont. Press/Vac. Relief 4

2VC6 2

Dl x

10 BFY A

C.

1,3 YES 4

2VC7 2

C2 x

0.75 GL A

AUTO 1,3 YES

<2 Sec. Cont. Atmos. Sample 4

2VC8 2

Cl x

0.75 GL A

AUTO 1,3 YES

<2 Sec. Cont. Atmos. Sample 4

2VC9 2

C2 x

0.75 GL A

c 3,4 NO 2VC10 2

Cl x

0.75 GL A

c 3,4 NO 2VC11 2

B2 x

0.75 GL A

AUTO 1,3 YES

<2 Sec. Cont. Atmos. Sample 4

2VC12 2

Bl x

0.75 GL A

AUTO 1,3 YES

<2 Sec. Cont. Atmos. Sample 4

2VC13 2

B2 x

0.75 GL A

c 3,4 NO 2VC14 2

Bl x

0.75 GL A

c 3,4 NO

VALVE:

2VC1, 2VC4, 2VCS CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Containment Purge (2VC1 and 4) and Pressure Vacuum Relief (2VC5)

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months; Stroke Time Testing each three months; Fail Safe Testing each three months.

BASIS FOR RELIEF:

a)

Valve is passive during.Power Operation.

This valve cannot be opened during Power Operation per Technical Specification 3.6.i.7.

b)

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This tests meets the intent of ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a)

These valves will be tested during Cold Shutdown and Refueling per Section XI.

b)

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2VC2, 2VC3, 2VC6 CATEGORY:

A CLASS:

2

  • FUNCTION:

Containment Isolation (inside containment) for Containment Purge (2VC2, 3) and Pressure Vacuum Relief (2VC6).

TEST REQUIREMENTS:

Leak Rate Testing less than 24 months; Stroke Time Testing each three months; Fail safe Testing each three months.

BASIS FOR RELIEF:

a)

These valves are passive during Power Operation.

They cannot be opened per Technical Specification 3.6.1.7.

e b)

Due to the physical arrangement of these valves a test in the direction of accident flow is not possible.

Also, because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used *for containment isolation.

ALTERNATE TESTING:

a)

These valves will be tested during Cold Shutdown and Refueling per Section XI.

b)

They will be tested in the opposite direction of flow when the 2VC2, 2VC3, and 2VCS are tested in accordance with Technical Specification 4.6.1.2.d.

VALVE:

2VC7 and 2VC8 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Containment Atmospheric Sampling.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME. B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

a) b)

These valves will be tested during Cold Shutdown and Refueling per Section XI.

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 88 of 95 Rev. 0

VALVE:

2VC11 and 2VC12 CATEGORY:

A CLASS:

2

~

FUNCTION:

Containment Isolation for Containment Atmospheric Sampling.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR50, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.l.2.d.

Page 89 of 95 Rev. 0

SYSTEM WASTE DISPOSAL -

LIQUID (WL) 205339 PAGE 90 of 95 Rev. 0

~--=-=-....::.=:.......::_=;_~--=.;.::,..;,_.:_...::_

(/)

(/)

'1:J E-<

µ:i

r:

'1:J

z; E-<

u Ai

~

.:i:

z; i:i::
z; VALVE
z; VALVE H

E-<

0 0

gJ E-<

REMARKS H

E-<

~~

~ (/)

Nl'MBER

(/)

~

CATEGORY

'1:J

.:i:

H

'1:J '1:J (NOT TO BE USED FOR RELIEF BASIS)

(/)

µ:)

~~

E-< p HP

~

8 N

~

(/) QI H QI H

u ><

00

~ gJ lli ~

u u

(/)

.:i: E-<

z; Ai A

B c D

E 2WL12 2

D7 x

3 DIA A

AUTO 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL13 2

D7 x

3 DIA A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL16 2

D6 x

3 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL17 2

D6 x

3 GL A

c 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL96 2

F7 x

0.75 DIA A

AUTO 1,3 YES

<10 Sec. Ph. ""A" Cont. Isol.

4 2WL97 2

F7 x

0.75 DIA A

AUTO 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL98 2

F7 x

1 DIA A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol*.

4 2WL99 2

F7 x

1 DIA A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL108 2

F7 x

1 DIA A

0 1,3 YES

<10 Sec. Ph. "A" Cont. Isol.

4 2WL190 2

E7 x

x 3

DIA M

LC 1,3 YES 7

2WL191 2

E7 x

x 3

DIA M

LC 1,3 YES 7

VALVE:

2WL96 and 2WL97 CATEGORY:

A CLASS:

2

  • FUNCTION:

Containment Isolation for line from Reactor Coolant Drai~ Tank to Gas Analyzer.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation,.

they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code, section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2WL98, 2WL99 and 2WL108 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation from/to Pressurizer Relief Tank to Waste Gas Header and from Nitrogen Header.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2WL12 and 2WL13 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation from Reactor Drain Tank Pumps to Waste Holdup Tanks.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFR, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2WL16 and 2WL17 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation from Containment Sump Pumps to Waste Holdup Tanks.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of these valves is containment isolation, they will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 91 of 95 Rev. 0

VALVE:

2WL190 and 2WL191 CATEGORY:

A/E CLASS:

2 FUNCTION:

Containment Isolation (inside containment) of Lines from Reactor Cavity to Spent Fu.el Cooling Pump.

TEST REQUIREMENTS:

a)

Valve exercising every three months.

b)

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

a)

Passive valve not required to change position to fulfill its safety function Valve is kept lock shut per Technical Specification 3.6.3.2.d, Table

3. 6-1.

b)

Technical Specification Table 3.6-1 exempts this valve from Leak Rate Test.

ALTERNATE TESTING:

a)

None.

b)

None.

Page 92 of 95 Rev. 0

SYSTEM.~ __ w_A_T_E_R __ RE c_o_VE __

RY ____

cw_R_-_c_v_c_> ________________ __ DRAWING NO.

2o533o/2o53ol

. PAGE 93 of 95 Rev. 0

~~------------------~

Cl)

C/l lil 8

ril

x::

ril z

8 u

0..

~

ici:

z

>t 0::

z VALVE z

VALVE H

8 0

0

~

8 REMARKS H

8

~~

Ji:. C/l NUMBER C/l

~

CATEGORY lil ici:

H ri:I ri:I (NOT TO BE USED FOR RELIEF BASIS)

C/l lil

~

~ re 8

H

~

8 N

I C/l QI H QI H

u >t 00

~~ ~~

CJ CJ C/l ici: 8 z 0.

A B c D E 2WR80 2

Gl x

3 DIA A

0 1,3 YES

<10 Sec. Ph. "A" Cont.

Isol~

4 (Print #205301) 2WR81 2

G2 x

x 3

CK SA c

1,6 YES (Print #205301)

VALVE:

2WR80 CATEGORY:

A CLASS:

2 FUNCTION:

Containment Isolation for Water to Pressurizer Relief Tank and Reactor Coolant Pump Seal Head Tanks.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accorda~ce with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

VALVE:

2WL81 CATEGORY:

A/C CLASS:

2 FUNCTION:

Containment Isolation for Water to Pressurizer Relief Tank and Reactor Coolant Pump Seal Head Tanks.

TEST REQUIREMENTS:

Leak Rate Testing less than each 24 months.

BASIS FOR RELIEF:

Because the safety-related function of this valve is containment isolation, it will be leak tested in accordance with Technical Specifications and 10CFRSO, Appendix J.

This test meets the intent of the ASME B&PV Code,Section XI for category A valves used.for containment isolation.

ALTERNATE TESTING:

Leak Rate Test per Technical Specification 4.6.1.2.d.

Page 94 of 95 Rev. 0

PART 3 PIPE SCHEDULES (CLASSIFICATION)

SCHED.

CLASS SCHED.

CLASS SCHED.

CLASS SCHED.

CLASS AF cs RHR WL & WG S4A 3

SOA 3

SlA 2

S3A 3

S4B NONE SOB 3

SlB 2

S3B 3

S4C 3

soc 2

S3C 3

S4D 3

SOD 3

SJ S3D 3

S4E 3

49A 3

S3E 3

CA 49B 2

S3F 3

BF 38A 2

49C 2

S3G 3

16.A 2

38B 3

49D 3

S3H 2

16B NONE 38C NONE 49E 2

S3J 2

38D NONE 49F 2

S3K 3

BR, eve & WR 49G 2

S3L 3

48A 2

DR & NT 49H 2

S3M 2

48B 2

20A 2

S3N 3

48C 2

20B 2

SS S30 3

48D 2

S6A 2

48E 2

FP S6B 3

48F 2

27A 2

S6C 2

48G 2

27B 3

S6D 3

48H 2

27C 3

S6E 2

48I 2

27D NONE 48J 2

27E NONE SW 48K 2

27A 2

48L 2

GB 27B 3

48M 2

S9A 2

27C 3

48N 2

S9B NONE 27D NONE 480 2

S9C NONE 27E NONE 48P 3

S9D NONE 48R 2

S9E NONE SF 48S 2

S9F NONE SSA 3

SSB 3

CH MS SSC 2

27A 2

12A 2

27B 3

12B NONE SA 27C 3

12C 3

32A 2

27D NONE 12D 3

32B NONE 27E NONE 32C NONE RC, PR 32D NONE cc 44A 1

S2A 3

44B 1

S2B 2

44C 2

S2C 3

44D 2

S2D 2

44E 2

.e Page 9S of 9S Rev. 0