ML19289F365: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19289F367 | | number = ML19289F367 | ||
| issue date = 06/04/1979 | | issue date = 06/04/1979 | ||
| title = | | title = LER 79-036/03L-0 on 790507:while Performing Visual Insp of Inaccessible Snubbers,Six Snubber Failed.Caused by Low Fluid Level.All Snubbers Disassembled,Inspected & Rebuilt | ||
| author name = Tollison A | | author name = Tollison A | ||
| author affiliation = CAROLINA POWER & LIGHT CO. | | author affiliation = CAROLINA POWER & LIGHT CO. |
Latest revision as of 04:43, 23 January 2020
Date released: 10/30/2019 | Download: ML19289F365 |
---|---|
ML19289F367 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 06/04/1979 |
From: | Tollison A CAROLINA POWER & LIGHT CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19289F367 (1) | |
ML19289F364 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 06/04/1979 |
From: | Banks H CAROLINA POWER & LIGHT CO. |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19289F364 (1) | |