ML19211C099: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:Chapter 5 - Cooling SystemsTable of ContentsCHAPTER 5COOLING SYSTEMSTABLE OF CONTENTSSectionTitle Page SHINE Medical Technologies5-iRev. 05a2IRRADIATION FACILITY COOLING SYSTEMS..............................................5a2.1-1 5a2.1
{{#Wiki_filter:COOLING SYSTEMS TABLE OF CONTENTS tion                                Title                                                                Page IRRADIATION FACILITY COOLING SYSTEMS .............................................. 5a2.1-1
.1  


==SUMMARY==
==SUMMARY==
DESCRIPTION .............................................................................5a2.1-15a2.2PRIMARY CLOSED LOOP COOLING SYSTEM .............................................5a2.2-15a2.2.1DESIGN BASES AND FUNCTIONAL REQUIREMENTS...............5a2.2-15a2.2.2PCLS ANALYSES ..........................................................................5a2.2-25a2.2.3INSTRUMENTATION AND CONTROL ..........................................5a2.2-35a2.2.4RADIATION MONITORS AND SAMPLING ...................................5a2.2-45a2.2.5PCLS INTERFACES ......................................................................5a2.2-45a2.2.6LEAK DETECTION .........................................................................5a2.2-5 5a2.2.7HYDROGEN LIMITS ......................................................................5a2.2-55a2.2.8TECHNICAL SPECIFICATIONS ....................................................5a2.2-55a2.3RADIOISOTOPE PROCESS FACILITY COOLING SYSTEM .........................5a2.3-15a2.3.1DESIGN BASES AND FUNCTIONAL REQUIREMENTS ..............5a2.3-15a2.3.2RPCS ANALYSES ..........................................................................5a2.3-15a2.3.3INSTRUMENTATION AND CONTROL ..........................................5a2.3-2 5a2.3.4RADIATION MONITORS AND SAMPLING ...................................5a2.3-25a2.3.5OTHER INTERFACES ...................................................................5a2.3-35a2.3.6TECHNICAL SPECIFICATIONS ....................................................5a2.3-35a2.4PROCESS CHILLED WATER SYSTEM ..........................................................5a2.4-15a2.4.1DESIGN BASIS AND FUNCTIONAL REQUIREMENTS ................5a2.4-15a2.4.2PROCESS CHILLED WATER SYSTEM ANALYSES ....................5a2.4-1 5a2.4.3INSTRUMENTATION AND CONTROL ..........................................5a2.4-1 Chapter 5 - Cooling SystemsTable of ContentsCHAPTER 5COOLING SYSTEMSTABLE OF CONTENTSSectionTitle Page SHINE Medical Technologies5-iiRev. 05a2.4.4RADIATION MONITORS AND SAMPLING ...................................5a2.4-2 5a2.4.5TECHNICAL SPECIFICATIONS ....................................................5a2.4-25a2.5PRIMARY CLOSED LOOP COOLING SYSTEM CLEANUP SIDE STREAM .................................................................................................5a2.5-15a2.5.1DESIGN BASIS AND PROCESS FUNCTIONS .............................5a2.5-15a2.5.2PCLS CLEANUP SIDE STREAM CONTROL AND INSTRUMENTATION .....................................................................5a2.5-15a2.5.3PCLS CLEANUP SIDE STREAM COMPONENTS AND LOCATIONS ...................................................................................5a2.5-15a2.5.4MAINTENANCE AND TESTING ....................................................5a2.5-25a2.5.5PREDICTING, MONITORING AND SHIELDING RADIOACTIVITY ............................................................................5a2.5-25a2.5.6TECHNICAL SPECIFICATIONS ....................................................5a2.5-35a2.6FACILITY DEMINERALIZED WATER SYSTEM .............................................5a2.6-1 5a2.7NITROGEN-16 CONTROL ..............................................................................5a2.7-15a2.8AUXILIARY SYSTEMS USING PRIMARY COOLANT  ...................................5a2.8-15a
DESCRIPTION ............................................................................. 5a2.1-1
.2  PRIMARY CLOSED LOOP COOLING SYSTEM ............................................. 5a2.2-1 5a2.2.1    DESIGN BASES AND FUNCTIONAL REQUIREMENTS ............... 5a2.2-1 5a2.2.2    PCLS ANALYSES .......................................................................... 5a2.2-2 5a2.2.3    INSTRUMENTATION AND CONTROL .......................................... 5a2.2-3 5a2.2.4    RADIATION MONITORS AND SAMPLING ................................... 5a2.2-4 5a2.2.5    PCLS INTERFACES ...................................................................... 5a2.2-4 5a2.2.6    LEAK DETECTION ......................................................................... 5a2.2-5 5a2.2.7    HYDROGEN LIMITS ...................................................................... 5a2.2-5 5a2.2.8    TECHNICAL SPECIFICATIONS .................................................... 5a2.2-5
.3  RADIOISOTOPE PROCESS FACILITY COOLING SYSTEM ......................... 5a2.3-1 5a2.3.1    DESIGN BASES AND FUNCTIONAL REQUIREMENTS .............. 5a2.3-1 5a2.3.2    RPCS ANALYSES .......................................................................... 5a2.3-1 5a2.3.3    INSTRUMENTATION AND CONTROL .......................................... 5a2.3-2 5a2.3.4    RADIATION MONITORS AND SAMPLING ................................... 5a2.3-2 5a2.3.5    OTHER INTERFACES ................................................................... 5a2.3-3 5a2.3.6    TECHNICAL SPECIFICATIONS .................................................... 5a2.3-3
.4  PROCESS CHILLED WATER SYSTEM .......................................................... 5a2.4-1 5a2.4.1    DESIGN BASIS AND FUNCTIONAL REQUIREMENTS ................ 5a2.4-1 5a2.4.2    PROCESS CHILLED WATER SYSTEM ANALYSES .................... 5a2.4-1 5a2.4.3    INSTRUMENTATION AND CONTROL .......................................... 5a2.4-1 NE Medical Technologies              5-i                                                                Rev. 0


==2.9REFERENCES==
COOLING SYSTEMS TABLE OF CONTENTS tion                                          Title                                                                Page 5a2.4.4    RADIATION MONITORS AND SAMPLING ................................... 5a2.4-2 5a2.4.5    TECHNICAL SPECIFICATIONS .................................................... 5a2.4-2
.................................................................................................5a2.9-1 5bRADIOISOTOPE PRODUCTION FACILITY COOLING SYSTEMS .....................5b-1 Chapter 5 - Cooling SystemsList of TablesLIST OF TABLES NumberTitle SHINE Medical Technologies5-iiiRev. 05a2.2-1PCLS Operating Parameters5a2.2-2PCLS Components5a2.2-3PCLS System Interfaces5a2.3-1RPCS Operating Parameters 5a2.3-2RPCS Components5a2.3-3RPCS Interfaces5a2.4-1PCHS Operating Parameters 5a2.4-2PCHS Components5a2.4-3PCHS System Interfaces5a2.6-1FDWS End Users5a2.6-2FDWS Components Chapter 5 - Cooling SystemsList of FiguresLIST OF FIGURES NumberTitle SHINE Medical Technologies5-ivRev. 05a2.1-1Cooling Systems Heat Flow Pathway Diagram5a2.2-1Primary Closed Loop Cooling System Flow Diagram5a2.3-1Radioisotope Process Facility Cooling System Flow Diagram5a2.4-1Process Chilled Water System Flow Diagram 5a2.6-1Facility Demineralized Water System Flow Diagram Chapter 5 - Cooling SystemsAcronyms and AbbreviationsACRONYMS AND ABBREVIATIONSAcronym/AbbreviationDefinition SHINE Medical Technologies5-vRev. 0
.5  PRIMARY CLOSED LOOP COOLING SYSTEM CLEANUP SIDE STREAM ................................................................................................. 5a2.5-1 5a2.5.1    DESIGN BASIS AND PROCESS FUNCTIONS ............................. 5a2.5-1 5a2.5.2    PCLS CLEANUP SIDE STREAM CONTROL AND INSTRUMENTATION ..................................................................... 5a2.5-1 5a2.5.3    PCLS CLEANUP SIDE STREAM COMPONENTS AND LOCATIONS ................................................................................... 5a2.5-1 5a2.5.4    MAINTENANCE AND TESTING .................................................... 5a2.5-2 5a2.5.5    PREDICTING, MONITORING AND SHIELDING RADIOACTIVITY ............................................................................ 5a2.5-2 5a2.5.6    TECHNICAL SPECIFICATIONS .................................................... 5a2.5-3
µmho/cmmicromho per centimeterALARAas low as reasonably achievableAr-41argon-41 ASMEAmerican Society of Mechanical EngineersBtuBritish thermal unitBtu/hrBritish thermal units per hour cmcentimeter DBTdry bulb temperatureFCASfacility compressed air systemFCHSfacility chilled water system FCRSfacility chemical reagent systemFDWSfacility demineralized water systemFPWSfacility potable water system FSTRfacility structureFVZ4facility ventilation zone 4gpmgallons per minute Chapter 5 - Cooling SystemsAcronyms and AbbreviationsACRONYMS AND ABBREVIATIONSAcronym/AbbreviationDefinition SHINE Medical Technologies5-viRev. 0hrhourHVACheating, ventilation, and air conditioningIAEAInternational Atomic Energy Agency ICBSirradiation cell biological shieldIFirradiation facilityIUirradiation unit kWkilowatt LABSquality control and analytical laboratoriesLWPSlight water pool systemMCWBmean coincident wet bulb temperature MEPSmolybdenum extraction and purification systemMMmillionN-16nitrogen-16 NDASneutron driver assembly systemNPSSnormal electrical power supply systemPCLSprimary closed loop cooling system Chapter 5 - Cooling SystemsAcronyms and AbbreviationsACRONYMS AND ABBREVIATIONSAcronym/AbbreviationDefinition SHINE Medical Technologies5-viiRev. 0PCHSprocess chilled water systemPICSprocess integrated control systemPSBprimary system boundary psipounds per square inchPVVSprocess vessel vent systemRCAradiologically controlled area ROreverse osmosis RPCSradioisotope process facility cooling systemRVZ1radiological ventilation zone 1RVZ1eradiological ventilation zone 1 exhaust subsystemRVZ1rradiological ventilation zone 1 recirculating cooling subsystemRVZ2radiological ventilation zone 2RVZ2rradiological ventilation zone 2 recirculating cooling subsystemSASSsubcritical assembly support structureSCASsubcritical assembly system Chapter 5 - Cooling SystemsAcronyms and AbbreviationsACRONYMS AND ABBREVIATIONSAcronym/AbbreviationDefinition SHINE Medical Technologies5-viiiRev. 0sccmstandard cubic centimeters per minutescfhstandard cubic feet per hourscfmstandard cubic feet per minute slpmstandard liters per minuteSRWPsolid radioactive waste processingTOGSTSV off-gas system TRPSTSV reactivity protection system TSPStarget solution preparation systemTSVtarget solution vesselUPSSuninterruptible electrical power supply system WBTwet bulb temperature Chapter 5 - Cooling Systems Summary DescriptionSHINE Medical Technologies5a2.1-1Rev. 05a2IRRADIATION FACILITY COOLING SYSTEMS5a2.1
.6  FACILITY DEMINERALIZED WATER SYSTEM ............................................. 5a2.6-1
.7  NITROGEN-16 CONTROL .............................................................................. 5a2.7-1
.8  AUXILIARY SYSTEMS USING PRIMARY COOLANT ................................... 5a2.8-1
.9  REFERENCES ................................................................................................. 5a2.9-1 RADIOISOTOPE PRODUCTION FACILITY COOLING SYSTEMS ..................... 5b-1 NE Medical Technologies                        5-ii                                                                Rev. 0
 
.2-1 PCLS Operating Parameters
.2-2 PCLS Components
.2-3 PCLS System Interfaces
.3-1 RPCS Operating Parameters
.3-2 RPCS Components
.3-3 RPCS Interfaces
.4-1 PCHS Operating Parameters
.4-2 PCHS Components
.4-3 PCHS System Interfaces
.6-1 FDWS End Users
.6-2 FDWS Components NE Medical Technologies        5-iii Rev. 0
 
.1-1 Cooling Systems Heat Flow Pathway Diagram
.2-1 Primary Closed Loop Cooling System Flow Diagram
.3-1 Radioisotope Process Facility Cooling System Flow Diagram
.4-1 Process Chilled Water System Flow Diagram
.6-1 Facility Demineralized Water System Flow Diagram NE Medical Technologies                5-iv                  Rev. 0
 
onym/Abbreviation        Definition ho/cm                      micromho per centimeter RA                        as low as reasonably achievable 1                        argon-41 ME                        American Society of Mechanical Engineers British thermal unit
/hr                        British thermal units per hour centimeter T                          dry bulb temperature AS                        facility compressed air system HS                        facility chilled water system RS                        facility chemical reagent system WS                        facility demineralized water system WS                        facility potable water system R                        facility structure 4                        facility ventilation zone 4 gallons per minute NE Medical Technologies 5-v                                      Rev. 0
 
onym/Abbreviation        Definition hour AC                        heating, ventilation, and air conditioning A                          International Atomic Energy Agency S                          irradiation cell biological shield irradiation facility irradiation unit kilowatt S                        quality control and analytical laboratories PS                        light water pool system WB                        mean coincident wet bulb temperature PS                        molybdenum extraction and purification system million 6                          nitrogen-16 AS                        neutron driver assembly system SS                        normal electrical power supply system LS                        primary closed loop cooling system NE Medical Technologies 5-vi                                          Rev. 0
 
onym/Abbreviation        Definition HS                        process chilled water system S                        process integrated control system B                          primary system boundary pounds per square inch VS                        process vessel vent system A                          radiologically controlled area reverse osmosis CS                        radioisotope process facility cooling system Z1                        radiological ventilation zone 1 Z1e                        radiological ventilation zone 1 exhaust subsystem Z1r                        radiological ventilation zone 1 recirculating cooling subsystem Z2                        radiological ventilation zone 2 Z2r                        radiological ventilation zone 2 recirculating cooling subsystem SS                        subcritical assembly support structure AS                        subcritical assembly system NE Medical Technologies 5-vii                                        Rev. 0
 
onym/Abbreviation        Definition m                          standard cubic centimeters per minute standard cubic feet per hour m                          standard cubic feet per minute m                          standard liters per minute WP                        solid radioactive waste processing GS                        TSV off-gas system PS                        TSV reactivity protection system S                        target solution preparation system target solution vessel SS                        uninterruptible electrical power supply system T                          wet bulb temperature NE Medical Technologies 5-viii                                      Rev. 0
 
.1  


==SUMMARY==
==SUMMARY==
DESCRIPTIONThe purpose of the irradiation facility (IF) cooling systems is to safely remove the fission and decay heat from the target solution and dissipate it to the environment. The primary closed loop cooling system (PCLS) removes heat from the subcritical assembly. The light water pool provides passive heat removal for the subcritical assembly and is described in detail in Section4a2.4. The radioisotope process facility cooling system (RPCS) is the secondary cooling system for the facility. See Chapter 13 for a discussion of accident scenarios.The target solution vessel (TSV) and neutron multiplier within each IU are cooled by the PCLS while the IU is in operation. The PCLS is a closed loop chilled water system that rejects heat to the RPCS, an intermediate chilled water loop, which rejects heat to the process chilled water system (PCHS). The PCHS is a closed chilled loop that rejects heat to the atmosphere by use of air-cooled chillers. Figure5a2.1-1 depicts the heat flow path from generation to the environment. The neutron driver cooling is addressed in Section4a2.3 and the recirculating heating, ventilation, and air conditioning (HVAC) fan-coil unit that is part of the radiological ventilation zone 1 recirculating cooling subsystem (RVZ1r) is discussed in Section 9a2.1
DESCRIPTION purpose of the irradiation facility (IF) cooling systems is to safely remove the fission and ay heat from the target solution and dissipate it to the environment. The primary closed loop ling system (PCLS) removes heat from the subcritical assembly. The light water pool vides passive heat removal for the subcritical assembly and is described in detail in tion 4a2.4. The radioisotope process facility cooling system (RPCS) is the secondary cooling tem for the facility. See Chapter 13 for a discussion of accident scenarios.
.The primary and secondary IF cooling systems maintain the capability to provide sufficient heat removal to support continuous operation at full licensed power as discussed in the subsequent sections.
target solution vessel (TSV) and neutron multiplier within each IU are cooled by the PCLS e the IU is in operation. The PCLS is a closed loop chilled water system that rejects heat to RPCS, an intermediate chilled water loop, which rejects heat to the process chilled water tem (PCHS). The PCHS is a closed chilled loop that rejects heat to the atmosphere by use of cooled chillers. Figure 5a2.1-1 depicts the heat flow path from generation to the environment.
Chapter 5 - Cooling SystemsSummary DescriptionSHINE Medical Technologies5a2.1-2Rev. 0Figure 5a2.1 Cooling Systems Heat Flow Pathway Diagram
neutron driver cooling is addressed in Section 4a2.3 and the recirculating heating, tilation, and air conditioning (HVAC) fan-coil unit that is part of the radiological ventilation e 1 recirculating cooling subsystem (RVZ1r) is discussed in Section 9a2.1.
primary and secondary IF cooling systems maintain the capability to provide sufficient heat oval to support continuous operation at full licensed power as discussed in the subsequent tions.
NE Medical Technologies                      5a2.1-1                                        Rev. 0
 
NE Medical Technologies 5a2.1-2 Rev. 0
.2.1      DESIGN BASES AND FUNCTIONAL REQUIREMENTS primary closed loop cooling system (PCLS) provides forced convection water cooling to the et solution vessel (TSV) and neutron multiplier during irradiation of the target solution and ediately prior to transferring target solution from the TSV to the TSV dump tank. The PCLS provides indirect cooling of the light water pool via natural convection heat transfer to the LS components submerged in the pool, as described in Subsection 4a2.7.3. The PCLS cts heat to the radioisotope process facility cooling system (RPCS). A total of eight pendent instances of PCLS are installed in the SHINE facility, one for each irradiation unit
. There are no common pressure retaining components between the instances of PCLS. The or PCLS equipment is located in the primary cooling room and the IU cell.
h instance of PCLS includes two pumps, a heat exchanger, and a cooling water clean-up stream located in the primary cooling rooms adjacent to the east side of each IU cell. In the ell, the PCLS is connected to the subcritical assembly system (SCAS) and includes an air arator, an expansion tank, and nitrogen-16 (N-16) delay tanks. Figure 5a2.2-1 provides a LS flow diagram.
process functions of the PCLS cooling system are to:
* remove heat from each TSV and neutron multiplier during full-power IU operation;
* cool the light water pool by natural convection heat transfer to PCLS components inside the light water pool;
* maintain water quality to reduce corrosion and scaling;
* limit concentrations of particulate and dissolved contaminants that could be made radioactive by neutron irradiation;
* reduce N-16 radiation exposure within the primary cooling room in support of as low as reasonably achievable (ALARA) goals; and
* remove entrained gases from the cooling water.
LS removes heat from the TSV and neutron multiplier during startup and irradiation by ulating water in an upward direction [
]PROP/ECI along the exterior surfaces of the TSV and neutron multiplier walls. The subcritical embly support structure (SASS) provides the shell side pressure boundary to direct the ling water flow past the TSV and neutron multiplier. The PCLS is attached to the SASS upper lower plenums.
LS is designed to remove a minimum of 580,000 British thermal units per hour (Btu/hr) 0 kilowatts [kW]) of heat from each IU during full-power operation and during shutdown ditions when target solution is in the TSV.
LS is designed to maintain the pressure of the cooling water in the SASS higher than the rnal pressure of the TSV. The TSV is designed and fabricated to prevent target solution from ing into the PCLS. See Section 4a2.4 for additional information related to the TSV.
PCLS cleanup side stream maintains system cooling water quality. The PCLS is designed to rate without corrosion inhibiting chemicals in the process fluid. The cleanup side stream can NE Medical Technologies                      5a2.2-1                                      Rev. 0
 
PCLS piping confines the cooling water within the IU cell and within the primary cooling room ted adjacent to the IU cell. Pressure retaining components are constructed of materials that ctively resist corrosion to limit activation products that could cause increased radiation osure of personnel and surrounding equipment. Major components are constructed of tenitic stainless steel.
PCLS air separator separates entrained gases from the cooling water and directs the gases he radiological ventilation zone 1 exhaust (RVZ1e) subsystem via the PCLS expansion tank.
6 is generated in the cooling water by the neutron activation of oxygen. Section 5a2.7 vides a discussion of the treatment of N-16 in the cooling water.
rpressure protection for PCLS is provided by system design. The shutoff head of the PCLS ps is below the PCLS design pressure. The PCLS is also directly vented to RVZ1e through PCLS expansion tank.
Table 5a2.2-1 for the PCLS operating parameters. See Table 5a2.2-2 for a list of the PCLS ponents.
.2.2    PCLS ANALYSES ailed analysis of the PCLS target solution cooling performance is found in Section 4a2.7.
t transfer and temperature profiles for the neutron multiplier are found in Subsection 4a2.2.6.
tive cooling to the TSV and neutron multiplier is unavailable, irradiation of the target solution be suspended. Target solution in the TSV will be transferred from the TSV to the TSV dump
  , which is passively cooled by the light water pool. See Subsection 4a2.4.2.2 for the heat oval capacity of the light water pool. Loss of cooling design basis accidents are discussed in section 13a2.1.3.
PCLS pumps operate in parallel to provide the design flowrate to the PCLS heat exchanger.
uld one pump fail, the second pump, operating at a minimum of [
    ]PROP/ECI, provides adequate cooling to allow continuation of full-power irradiation while ntaining the bulk target solution temperature less than 176°F (80°C) within the TSV.
light water pool and TSV are located within the primary confinement, which also provides finement of the components of the PCLS located within the IU cell, as discussed in tion 6a2.2. The PCLS piping penetrations through primary confinement are located above minimum acceptable water level in the pool.
elding to protect workers and reduce dose rates to equipment is provided by the irradiation biological shield (ICBS), described in detail in Section 4a2.5.
cts resulting from a primary cooling water breach are discussed in Subsection 4a2.7.3.7.
s of primary cooling water does not result in loss of integrity of the primary system boundary B). Low cooling water flow causes an IU Cell Safety Actuation, which results in the TSV dump es opening and the target solution draining to the TSV dump tank. The thermal mass of the NE Medical Technologies                      5a2.2-2                                        Rev. 0
 
atural convection heat transfer. See Subsection 4a2.7.3.8 for further discussion on the sition from forced to natural convection.
ding of the SCAS cooling channels caused by loss of primary cooling water causes reactivity rtions as discussed in Subsection 13a2.1.2. To prevent the drainage of primary cooling water the SCAS, the SCAS is located below grade in the light water pool. Portions of the PCLS ted outside of the light water pool are above grade to prevent gravity drainage of the SCAS ling channels.
PCLS pumps draw cooling water from a line connected to the PCLS expansion tank.
ause the expansion tank is vented, a leak of the PCLS pressure boundary would result in the LS expansion tank level reducing until the PCLS return line breaks vacuum. Once the PCLS rn line breaks vacuum, the PCLS pumps cannot draw more water out of the SCAS. This ngement ensures that the PCLS pumps cannot draw the water out of the SCAS cooling nnels.
use of centrifugal pumps and an air separator prevents the PCLS from effectively voiding the ling channels by pumping air into the SCAS.
functions or leaks in the PCLS do not cause uncontrolled release of primary cooling water ide the radiologically controlled area (RCA). The facility structure (FSTR) provides barriers at s from the RCA to prevent the release of potentially contaminated water to the uncontrolled ironment.
PCLS piping penetrating confinement boundaries are provided with isolation capabilities.
ng systems that pass between confinement boundaries are equipped with either:
* a locked closed manual isolation valve, or
* an automatic isolation valve that takes the position that provides greater safety upon loss of actuating power.
nual isolation valves are maintained locked-shut for any conditions requiring confinement ndary integrity. The automatic isolation valves are closed as part of an IU Cell Safety uation if the TSV reactivity protection system (TRPS) detects a malfunction of PCLS, akage of primary cooling water into the PSB, or outleakage of target solution into the primary ling water.
.2.3      INSTRUMENTATION AND CONTROL ssure, flow, temperature, conductivity, and level instrumentation monitor the operating ameters of the PCLS.
perature instrumentation is provided to ensure the cooling water supply temperature ains within allowable limits despite variations in TSV power. Output from the temperature rumentation is used for controlling the flow of RPCS water through the PCLS heat exchanger egulate the cooling water supply temperature at the SCAS cooling water inlet.
NE Medical Technologies                    5a2.2-3                                        Rev. 0
 
rate with either one or both pumps operating.
e PCLS temperature or flowrate is outside allowable limits, the TRPS initiates an IU Cell ety Actuation, resulting in a transfer of the target solution to the TSV dump tank where it is led by natural convection to the light water pool.
ansion tank level instrumentation provides indication of loss of cooling water, such as by poration or radiolysis. Addition of makeup cooling water is a manual operation. Expansion level instrumentation can also perform a leak detection function as described in section 5a2.2.6.
ductivity instrumentation is provided to measure the conductivity of the PCLS water and nitor the performance of the PCLS cleanup side stream. Conductivity instrumentation can also orm a leak detection function as described in Subsection 5a2.2.6.
PCLS pressure, flow, temperature, and expansion tank level indications are available locally in the control room. Sampling and analysis of cooling water from the PCLS is performed lly. System operational controls are in the control room.
.2.4    RADIATION MONITORS AND SAMPLING RVZ1e line ventilating the PCLS expansion tank headspace is equipped with radiation nitors. The RVZ1e radiation monitors are intended to detect leakage of target solution or on product gases from the PSB or neutron multipliers. If radiation exceeding a predetermined oint is detected, the TRPS initiates an IU Cell Safety Actuation and the RVZ1e line is ated.
mpling and analysis of the water from the PCLS is performed to ensure that the water quality uirements are being maintained and contaminants are not present in the cooling water.
ntaining water quality ensures functional and safe operation by reducing corrosion damage scaling. See Table 5a2.2-1 for water quality requirements. Sampling of cooling water for ological contaminants is performed to detect possible leakage of target solution into the PSB.
.2.5    PCLS INTERFACES system interfaces of the PCLS are listed in Table 5a2.2-3.
PCLS cooling water is pumped through the PCLS heat exchanger, where the heat is sferred to the RPCS and subsequently transferred to the process chilled water system HS), where it is dissipated to the environment.
PCLS cooling water leaves the SCAS and enters the PCLS air separator, which allows ained radiolytic gas to separate from the cooling water. Besides hydrogen and oxygen, the dspace contains air, water vapor, and small amounts of N-16 and argon-41 (Ar-41). An rface between the RVZ1e and the expansion tank allows radiolytic gases to be purged to Z1e, preventing the buildup of hydrogen gas. Ambient air from within the primary confinement ndary is drawn through a flame arrestor and filter for sweeping of the expansion tank dspace.
NE Medical Technologies                    5a2.2-4                                      Rev. 0
 
rface with the FDWS. This prevents possibly contaminated PCLS cooling water from coming ontact with the makeup water. The backflow prevention components help ensure the ALARA elines in Chapter 11 are met.
.2.6    LEAK DETECTION k detection is provided by the PCLS expansion tank level instrumentation, TSV dump tank l instrumentation, and conductivity instrumentation. Leak detection is also provided by ation monitoring and sampling, as discussed in Subsection 5a2.2.4.
expansion tank includes level instruments that allows operators to trend levels within the LS, which can indicate slow leaks of cooling water. Additionally, level indication in the TSV p tank provides indication of inleakage of cooling water into the PSB. If inleakage into the B is detected, the TRPS initiates an IU Cell Safety Actuation.
ductivity instrumentation can detect increases in conductivity of the PCLS cooling water ulting from inleakage of target solution.
.2.7      HYDROGEN LIMITS iolysis of the primary cooling water and the light water pool water results in the generation of rogen and oxygen gases. These gases must be vented to prevent the buildup of hydrogen.
RVZ1e draws air from the primary confinement and through the PCLS expansion tank dspace to dilute hydrogen within the primary confinement and expansion tank while the LS system is required to be in operation.
ing full-power irradiation, up to approximately 0.15 standard cubic feet per hour (scfh) standard cubic centimeters per minute [sccm]) of hydrogen gas is calculated to be generated e primary cooling water and up to approximately 0.38 scfh (180 sccm) of hydrogen is ulated to be generated in the light water pool.
Z1e provides a nominal flowrate of approximately 1 standard cubic feet per minute (scfm) standard liter per minute [slpm]) to the expansion tank headspace while the PCLS system is uired to be in operation. The relatively low nominal flowrate maintains hydrogen centrations within the primary confinement and expansion tank below 1 percent by volume e minimizing release of Ar-41 to the facility stack. Rates of Ar-41 production and release are cribed in Section 11.1.
.2.8      TECHNICAL SPECIFICATIONS tain material in this section provides information that is used in the technical specifications.
includes limiting conditions for operation, setpoints, design features, and means for omplishing surveillances. In addition, significant material is also applicable to, and may be d for the bases that are described in the technical specifications.
NE Medical Technologies                    5a2.2-5                                        Rev. 0
 
Table 5a2.2 PCLS Operating Parameters PCLS Parameter                                  Nominal Values oling Medium                  Water oling Medium Makeup            Facility demineralized water system (FDWS) urce at Exchanger Duty              580,000 Btu/hr (170 kW) per irradiation unit (IU) cell oling Medium Supply            59&deg;F to 77&deg;F (15&deg;C to 25&deg;C) mperature oling Medium Flow Rate        Minimum flow rate: [                              ]PROP/ECI Nominal flow rate: [        ]PROP/ECI oling Medium Quality          Conductivity: < 5 micromho per centimeter (&#xb5;mho/cm) pH: 5.5 to 7.5 stem Type                      Forced cooling water, closed loop stem Design Pressure          100 pounds per square inch (psi) stem Design Temperature        200&deg;F (93&deg;C) aterial of Construction and    Major components are fabricated from austenitic stainless brication                      steel NE Medical Technologies                    5a2.2-6                                      Rev. 0
 
Table 5a2.2 PCLS Components Component                          Functions                      Code/Standard LS heat exchanger      Transfers heat from PCLS cooling      ASME BPVC, Section VIII, loop to the RPCS                      Division 1 (ASME, 2010)
LS expansion tank      Provides thermal expansion            ASME BPVC Section VIII, protection and pump head, and          Division 1 (ASME, 2010) facilitates cooling loop level monitoring ping components          PCLS cooling loop piping              ASME B31.3 (ASME, 2013) trogen-16 (N-16) delay  Allows for the decay of N-16 that is  ASME B31.3 (ASME, 2013) nks                      generated in the cooling water by neutron activation of oxygen and for the decay of the gaseous flow path from the PCLS air separator LS pumps                Circulates PCLS cooling water          Note(a) through system components LS instrumentation      Provides indication of PCLS            See Chapter 7 for safety-operating parameters                  related instrumentation See Note(a) for nonsafety-related instrumentation LS air separator        Allows entrained radiolytic gas to    ASME BPVC Section VIII, leave the cooling water and enter into Division 1 (ASME, 2010) the expansion tank where it is vented to prevent the buildup of hydrogen in the system LS flame arrestor with  Prevents the ignition of hydrogen in  Note(a) er                      the PCLS expansion tank if RVZ1e flow through the expansion tank is lost LS deionizer bed        Removes dissolved ions from the        Note(a)
PCLS cooling water ommercially available equipment designed to standards satisfying system operation.
NE Medical Technologies                    5a2.2-7                                    Rev. 0
 
Table 5a2.2 PCLS System Interfaces System                                      Interface Description dioisotope process        The RPCS interfaces with each of the eight instances of PCLS oling water system        inside the radiologically controlled area (RCA). Nonsafety-related PCS)                      manual isolation valves are located at the interface with PCLS.
cility demineralized      The FDWS interfaces with each of the eight PCLS cooling loops ter system (FDWS)        inside the RCA. The FDWS interfaces with the PCLS downstream of a FDWS vacuum breaker. Nonsafety-related manual isolation valves are located at the interface with PCLS.
bcritical assembly        The SCAS interfaces with the PCLS in each of the eight light water stem (SCAS)                pools located in the irradiation facility (IF).
rmal electrical power    The NPSS provides power to PCLS process skid, including pumps pply system (NPSS)        and instrumentation, located inside the IF.
interruptible electrical  The UPSS provides the PCLS safety-related instrumentation with wer supply system          electrical power during normal conditions and during and following PSS)                      design basis events.
V reactivity protection  The PCLS provides instrumentation for the TRPS to monitor stem (TRPS)                variables important to the safe operation of the PCLS. The TRPS provides controls to the PCLS components to perform safety actuations when monitored variables exceed predetermined limits.
cility compressed air      The FCAS provides compressed gas to the PCLS loop pneumatic stem (FCAS)                control mechanisms located inside the IF.
ocess integrated          The PICS monitors and controls the PCLS process parameters, ntrol system (PICS)        utilizing the instrumentation and controlled components within the IF.
diological ventilation    The RVZ1 provides an exhaust path from the headspace of each of ne 1 (RVZ1)                the eight PCLS expansion tanks. The PCLS removes radiolytic gas from the cooling water and vents it to prevent combustible gas mixtures from forming.
diological ventilation    The RVZ2 provides an indirect source of makeup air into the PCLS ne 2 (RVZ2)                expansion tanks via the supply air provided to the IF through the primary confinement.
NE Medical Technologies                      5a2.2-8                                    Rev. 0
 
NE Medical Technologies 5a2.2-9 Rev. 0
.3.1    DESIGN BASES AND FUNCTIONAL REQUIREMENTS radioisotope process facility cooling system (RPCS) removes heat generated from within the ological control area (RCA) and rejects the heat to the process chilled water system (PCHS).
RPCS is an intermediate closed-loop forced liquid cooling system that recirculates cooling er. The RPCS removes heat from the primary closed loop cooling system (PCLS), the tron driver assembly system (NDAS) cooling cabinets, the target solution vessel off-gas tem (TOGS), the recirculating heating, ventilation, and air conditioning (HVAC) fan-coil units are part of the radiological ventilation zone 1 recirculating cooling system (RVZ1r), the rculating HVAC fan-coil units that are part of the radiological ventilation zone 2 recirculating ling system (RVZ2r), the target solution preparation system (TSPS), the process vessel vent tem (PVVS), and the molybdenum extraction and purification system (MEPS). The total and placed on the RPCS by other systems is approximately 11.6 million British thermal units hour (MMBtu/hr) (3400 kilowatts [kW]). The RPCS consists of a heat exchanger, pumps, tem expansion tank, valves, instrumentation, and heat exchanger interfaces identified above.
RPCS major equipment is located in the RPCS room, within the RCA.
process functions of the RPCS are to:
* maintain higher pressure than the cooling systems served at the respective interfaces;
* remove process heat from systems served;
* maintain cooling water quality to reduce corrosion and scaling; and
* reject heat to the PCHS.
RPCS is a nonsafety-related system and is not credited with preventing or mitigating any ign basis events. See Figure 5a2.3-1 for the process flow diagram of the RPCS. See le 5a2.3-1 for the RPCS design and operating parameters. See Table 5a2.3-2 for the RPCS ponents.
.3.2    RPCS ANALYSES cooling function of the RPCS is not credited in the safety analysis for any system served by RPCS. If active cooling to the TSV and neutron multiplier is unavailable due to a loss of the CS, irradiation of the target solution will be suspended. Any target solution in the TSV will be sferred from the TSV to the TVS dump tank which is passively cooled by the light water pool.
tion 4a2.4 provides a discussion of the heat removal capacity of the light water pool. Loss of ling design basis accidents are discussed in Subsection 13a2.1.3.
essure cascade is maintained at each system heat exchanger that receives service such that RPCS cooling water is maintained at a higher pressure than those systems with the potential ontaminate the RPCS. Additionally, the PCHS is maintained at a higher pressure than the CS at the RPCS heat exchanger so that any leakage between the RPCS and the PCHS will d to leak into the RPCS.
keup water to the RPCS is from the facility demineralized water system (FDWS) as described ection 5a2.6. The RPCS piping includes backflow prevention components at the interface the FDWS. This prevents potentially contaminated RPCS cooling water from contacting the NE Medical Technologies                    5a2.3-1                                      Rev. 0
 
.3.3    INSTRUMENTATION AND CONTROL process integrated control system (PICS) monitors the RPCS pressure, flow, temperature, conductivity to ensure operation within design parameters. Instrumentation is located in the CS loop to obtain accurate system operating information. Setpoints ensure that operators are ted when operating conditions are out of specification. Pressure, flow, and temperature are nitored within the RPCS to ensure that the system is operating within design conditions. Flow trol is provided on the downstream side of each interfacing systems heat exchanger.
onductivity analyzer is located near the RPCS heat exchanger and pump to monitor the ductivity of the RPCS cooling water. If the conductivity measurement is out of system rable parameters, operators are alerted such that the appropriate corrective actions can be
: n. This protection limits corrosion and scaling damage in the RPCS system. Pressure, flow, temperature instrumentation on the supply and return lines of the RPCS can indicate a function in the system with an increase in pressure drop and/or low system flow. See le 5a2.3-1 for the RPCS operating parameters.
heat removal provided by RPCS to the PCLS is controlled by adjusting the RPCS flow rate ach heat exchanger. The RPCS flow rate is controlled on the return side of the process tem heat exchanger by means of a modulating flow control valve. This arrangement ensures the pressure differential between the RPCS and the PCLS is maintained, regardless of the ition of the temperature control valves.
.3.4    RADIATION MONITORS AND SAMPLING design of the cooling system ensures that release of radioactivity through the secondary ling system to the unrestricted environment will not lead to potential exposures to the public in ess of the requirements of 10 CFR 20 and the ALARA program guidelines. The RPCS is ntained at a higher pressure than the systems served. Furthermore, the RPCS is a closed system located inside the RCA. The facility structure (FSTR) provides barriers at exits from RCA to prevent the release of potentially contaminated cooling water to the uncontrolled ironment.
mpling and analysis of cooling water from the RPCS is performed to ensure radiological taminants are below acceptable limits. If unacceptable levels of contamination are found, the tem will be shut down and the contaminated cooling water will be purified using ion exchange
: s. Operators then inspect the malfunctioning equipment and remedy the issue accordingly.
mpling and analysis of the cooling water from the RPCS is also performed to ensure that the er quality requirements are being maintained. Maintaining cooling water quality minimizes the ential for damage due to corrosion and scaling. Table 5a2.3-1 describes the RPCS cooling er quality requirements.
NE Medical Technologies                    5a2.3-2                                      Rev. 0
 
RPCS components are listed in Table 5a2.3-2, including design codes and standards. The CS interfaces with the PCHS at the RPCS heat exchanger located within the RCA boundary.
system interfaces of the RPCS are listed in Table 5a2.3-3.
.3.6    TECHNICAL SPECIFICATIONS re are no technical specification parameters identified for the RPCS.
NE Medical Technologies                  5a2.3-3                                  Rev. 0
 
Table 5a2.3 RPCS Operating Parameters Parameter                                      Nominal Value oling Medium              Water oling Medium Makeup        FDWS urce pply Conditions            Temperature: 40&deg;F to 44&deg;F (4.5&deg;C to 6.5&deg;C) turn Conditions            Temperature: 60&deg;F to 64&deg;F (15.5&deg;C to 17.5&deg;C) sign Pressure              100 pounds per square inch (psi) sign Temperature          200&deg;F (93&deg;C) at Exchanger Duty          11.6 MMBtu/hr (3400 kW) oling Medium Flow Rate    Volumetric flow rate: < 3000 gallons per minute (gpm) oling Medium Quality      Conductivity: < 2000 &#xb5;mho/cm pH: 6 to 8.
Based on recommendations for secondary cooling water parameters in IAEA No. NP-T-5.2 (IAEA, 2011).
stem Type                  RPCS is a forced liquid, closed loop cooling system circulating water to remove heat from PCLS and other process and non-process systems via heat exchangers.
aterial of Construction    RPCS components are designed and fabricated in accordance d Fabrication              with the codes and standards listed in Table 5a2.3-2.
NE Medical Technologies                  5a2.3-4                                      Rev. 0
 
Table 5a2.3 RPCS Components Component                        Description                    Code/Standard CS heat exchanger      Transfers heat from RPCS to PCHS.      Note(a)
CS expansion tank      Provides thermal expansion protection  Note(a) for the RPCS piping and components.
CS buffer tank        Provided to increase the system        Note(a) volume to levels required to maintain system loop times.
ping components        RPCS piping.                          ASME B31.9 (ASME, 2017)
CS pump                Circulates RPCS water through system  Note(a) components.
CS instrumentation    Provide indication of RPCS operating  Note(a) parameters (pressure, temperature, flow, and level).
ommercially available equipment designed to standards to satisfy system operation.
NE Medical Technologies                  5a2.3-5                                  Rev. 0
 
Table 5a2.3 RPCS Interfaces (Sheet 1 of 2)
System                                  Interface Description imary closed loop      The RPCS interfaces with each of the eight PCLS cooling loops inside oling system (PCLS)    the RCA. Nonsafety-related manual isolation valves are located at the interface with PCLS.
V off-gas system      Interfaces at the TOGS cooling water supply and return connections OGS)                    inside the RCA to condense water vapor and remove heat from recombiner condensers and condenser-demisters. Nonsafety-related manual isolation valves are located at the interface with TOGS.
olybdenum extraction    Interfaces at the evaporator supply and return connections inside the d purification system  RCA to facilitate condensation of water vapor. Nonsafety-related EPS)                  manual isolation valves are located at the interface with MEPS.
ocess vessel vent      Interfaces at the supply and return connections of the PVVS cooler and stem (PVVS)            condensers within the RPF section of the RCA to reduce the PVVS process temperature and relative humidity. Nonsafety-related manual isolation valves are located at the interface with PVVS.
ocess chilled water    Interfaces at the supply and return connections of the RPCS heat stem (PCHS)            exchanger inside the RCA and transfers heat from the RPCS to the PCHS so it can be released to the environment exterior to the RCA boundary. Nonsafety-related manual isolation valves are located at the interface with PCHS.
rget solution          Interfaces at the supply and return connections of the TSPS reflux eparation system        condensers inside the RCA to mitigate liquid loss during dissolution.
SPS)                    Nonsafety-related manual isolation valves are located at the interface with TSPS.
diological ventilation Interfaces at the supply and return connections of the IU supplemental ne 1 recirculating    cooling system fan coil, exterior to the primary confinement boundary, oling subsystem        inside the RCA. Nonsafety-related manual isolation valves are located VZ1r)                  at the interface with RVZ1r.
diological ventilation Interfaces at the supply and return connections of the recirculating unit ne 2 recirculating    fan coils inside the RCA. Nonsafety-related manual isolation valves are oling subsystem        located at the interface with RVZ2r.
VZ2r) cility demineralized  Interfaces upstream of the RPCS pumps inside the RCA to supply ter system (FDWS)      makeup water to the RPCS.
utron driver assembly  Interfaces with each of the nine NDAS cooling cabinets within the RCA stem (NDAS)            to remove heat from the independent NDAS cooling loops.
NE Medical Technologies                  5a2.3-6                                        Rev. 0
 
System                                  Interface Description ocess integrated      PICS monitors and controls RPCS actuators and instrumentation on ntrol system (PICS)    valves, piping, and components.
rmal electrical power The NPSS provides power to RPCS equipment and instrumentation.
pply system (NPSS)
NE Medical Technologies                  5a2.3-7                                    Rev. 0
 
NE Medical Technologies 5a2.3-8 Rev. 0
.4.1    DESIGN BASIS AND FUNCTIONAL REQUIREMENTS process chilled water system (PCHS) removes heat from the radioisotope process facility ling system (RPCS) from within the radiologically controlled area (RCA) and rejects the heat he environment. The PCHS interfaces with the RPCS heat exchanger and is comprised of ulation pumps, flow control valves, an expansion tank, a buffer tank, a glycol makeup unit, rumentation, and packaged air-cooled chillers. The PCHS is a forced liquid, convective flow, ed loop cooling system that uses air-cooled chillers to facilitate heat rejection to the ironment. The PCHS is designed to remove the total heat transfer demand placed on RPCS ther systems.
PCHS is a nonsafety-related system and is not credited with preventing or mitigating any ign basis events. Table 5a2.4-1 provides the PCHS operating parameters. Table 5a2.4-2 vides a description of PCHS components. Figure 5a2.4-1 provides a process flow diagram of PCHS.
process functions of the PCHS are to:
* remove heat from the RPCS heat exchangers;
* reject heat to the environment;
* maintain water quality to reduce corrosion and scaling; and
* prevent freezing of exterior piping and components.
PCHS is designed for local outdoor operation. The system is operated with a propylene ol/water mixture through the RPCS heat exchanger. Process generated heat is transferred the facility process systems into the RPCS inside the RCA. The RPCS transfers this cess heat to the PCHS through the RPCS heat exchanger, located inside the RCA. The HS then routes the process heat outside the RCA, and ultimately out of the facility to air-led chillers. The PCHS is provided makeup water from the facility demineralized water tem (FDWS), which is described in Section 5a2.6, and glycol through a manual fill point for mal operation. Table 5a2.4-1 describes the PCHS water quality requirements.
.4.2    PROCESS CHILLED WATER SYSTEM ANALYSES PCHS is designed to remove the total heat transfer demand placed on the RPCS by other tems of approximately 11.6 MMBtu/hr (3400 kW). The PCHS is maintained at a higher ssure than the RPCS to ensure that leakage at the system interface heat exchanger flows potentially less contaminated cooling water to potentially more contaminated cooling water.
.4.3    INSTRUMENTATION AND CONTROL PCHS provides output signals to the process integrated control system (PICS) for the nitoring of cooling water temperatures, pressures, tank level, and flow rates.
ssure, flow, tank level, and temperature measurement instrumentation are strategically ted in the PCHS cooling loop to obtain system operating information. Setpoints ensure that rators are alerted when an operating condition is out of specification. Buffer tank level oints are monitored to indicate high or low system volume conditions.
NE Medical Technologies                    5a2.4-1                                        Rev. 0
 
RPCS, transfers heat from the PCLS to the PCHS. The PCHS dissipates the heat from the CS to the environment. The RPCS is maintained at a lower pressure than PCHS at the RPCS t exchanger as such any leakage between RPCS and PCHS would tend to leak into RPCS.
PCLS, RPCS, and PCHS are closed loop systems. Samples of cooling water are analyzed contamination and conductivity. The contaminated volume of cooling water is recycled in er an on-site recycling unit or a mobile service unit. Water quality is maintained to reduce osion and scaling in the system. System cooling water level is monitored to provide indication ystem in-leakage or out-leakage. These design features ensure that radioactivity is not ased through the PCHS to the unrestricted environment and will not lead to potential osures of the public in excess of the requirements of 10 CFR 20 and the as low as reasonably ievable (ALARA) program guidelines.
system interfaces of the PCHS are listed in Table 5a2.4-3.
.4.5    TECHNICAL SPECIFICATIONS re are no technical specification parameters identified for the PCHS.
NE Medical Technologies                    5a2.4-2                                        Rev. 0
 
Table 5a2.4 PCHS Operating Parameters PCHS Parameter                                    Nominal Values oling medium                        Propylene glycol/water oling medium make-up source        FDWS with manual addition of propylene glycol pply conditions                    Temperature: 30&deg;F to 40&deg;F (-1&deg;C to 4.5&deg;C) turn conditions                    Temperature: 50&deg;F to 60&deg;F (10&deg;C to 15.5&deg;C) sign pressure                      160 psi sign temperature                    200&deg;F (93.3&deg;C) vironment                          Design dry bulb temperature (DBT) range: -10&deg;F to 91.5&deg;F (-23&deg;C to 33&deg;C) iller heat duty                    11.6 MMBtu/hr (3400 kW) oling medium flow rate              Volumetric flow rate: < 2200 gallons per minute (gpm) stem type                          PCHS is a forced liquid, closed loop cooling system circulating propylene glycol/water. The PCHS removes heat from the RPCS heat exchangers and transfer it to air-cooled chillers located outside of the facility.
aterial of construction and          PCHS components are designed and fabricated in brication                            accordance with the codes and standards listed in Table 5a2.4-2.
at dissipation                      This system dissipates heat to the environment through air-cooled chillers.
NE Medical Technologies                    5a2.4-3                                        Rev. 0
 
Table 5a2.4 PCHS Components Component                        Description                  Code/Standard HS chiller              Transfers heat from PCHS to the    Note (a) environment.
HS expansion tank        Provides thermal expansion          Note (a) protection for the PCHS piping and components.
HS buffer tank          Provided to increase the system    Note (a) volume to levels required to maintain system loop times.
HS pump                  Circulates PCHS Coolant through    Note (a) system components ping components          PCHS piping.                      ASME B31.9 (ASME, 2017) strumentation            Provide indication of PCHS          Note (a) operating parameters (pressure, temperature, flow, and level).
ommercially available equipment designed to standards to satisfy system operation.
NE Medical Technologies                  5a2.4-4                                  Rev. 0
 
Table 5a2.4 PCHS System Interfaces System                                  Interface Description dioisotope process cooling      Interfaces at the RPCS heat exchangers inside RCA.
stem (RPCS)                      The PCHS removes heat from the RCA through the RPCS heat exchangers and rejects the heat to the environment outside the RCA.
mospheric environment            Interfaces at the PCHS chillers. Transfers heat from the PCHS through air chillers to the environment outside of the RCA boundary.
NE Medical Technologies                5a2.4-5                                      Rev. 0
 
NE Medical Technologies 5a2.4-6 Rev. 0
.5.1    DESIGN BASES AND PROCESS FUNCTIONS primary closed loop cooling system (PCLS) cleanup side stream maintains the required er quality limits of the PCLS.
following are the process functions of the PCLS cleanup side stream:
* Maintain water quality to reduce corrosion and scaling; and
* Limit concentrations of particulate and dissolved contaminants that could be made radioactive by neutron irradiation to achieve as low as reasonably achievable (ALARA) goals.
PCLS cooling water is treated to meet water quality limits discussed in Table 5a2.2-1. The nup components are located on a side stream through which the PCLS diverts a portion of cooling water flow. The components that perform the PCLS cooling water treatment are ted within the PCLS cleanup side stream flow path.
PCLS cleanup side stream includes conductivity instrumentation to monitor water quality, nizer beds to remove ionic species, and filters on the inlet and outlet of the deionizer beds to ove particulates from the cooling water.
ntaining the design water quality limits corrosion damage and scaling of the PCLS, the target tion vessel (TSV), and the neutron multiplier, which are components of the subcritical embly system (SCAS). The PCLS cleanup side stream removes contaminates that could ome activated and radioactive materials from the PCLS cooling water in order to meet RA occupational exposure goals described in Section 11.1. The PCLS cleanup side stream its components are designed and selected so that malfunctions are unlikely. Malfunctions leaks in the PCLS and the PCLS cleanup side streams are addressed in Subsection 5a2.2.2.
Table 5a2.2-2 for the list of PCLS components and their functions.
PCLS cleanup side stream components are designed and fabricated in accordance with the es and standards listed in Table 5a2.2-2.
.5.2    PCLS CLEANUP SIDE STREAM CONTROL AND INSTRUMENTATION PCLS cleanup side stream instrumentation is located in the primary cooling room.
ductivity instrumentation located at the outlet of the PCLS cleanup side stream measures the ductivity within the PCLS. The pH of the PCLS cooling water is monitored through sampling he system and analysis of the cooling water is performed by the quality control and analytical ing laboratories (LABS). Pressure, flow, temperature, conductivity, and level instrumentation nitor the operating parameters of the PCLS as discussed in Subsection 5a2.2.3.
.5.3    PCLS CLEANUP SIDE STREAM COMPONENTS AND LOCATIONS PCLS cleanup side stream components are located in the primary cooling room, directly cent to the IU cells.
NE Medical Technologies                    5a2.5-1                                        Rev. 0
 
nup side stream. After the PCLS cooling water is diverted to the PCLS cleanup side stream, st flows through a pre-filter, through a deionizer bed and finally through a post-filter. Following process, the PCLS cooling water side stream is reintroduced into the PCLS main flow path r to entering the SCAS.
.5.4    MAINTENANCE AND TESTING PCLS cleanup side stream pre-filters, post-filters, and deionizer units are replaced at regular rvals in accordance with maintenance procedures. Spent filters and deionizer units are osed of as radioactive waste via the solid radioactive waste processing (SRWP) system.
her discussion of SRWP can be found in Section 9b.7. Subsection 11.2.2 addresses pliance with 10 CFR 20 and presents ALARA guidelines relative to radioactive waste control.
le 11.2-1 provides a list of solid radioactive wastes including an estimate of annual quantities erated and disposal destinations.
mpling and testing of the PCLS cooling water is performed as described in section 5a2.2.5.
ating the PCLS cleanup side stream from the associated PCLS cooling loop for maintenance poses does not disrupt irradiation unit (IU) operation or prevent safe IU shutdown.
.5.5    PREDICTING, MONITORING AND SHIELDING RADIOACTIVITY PCLS cleanup side stream components are located entirely within the primary cooling room ociated with their respective IU cell. Each primary cooling room is located within the diation cell biological shield (ICBS). The ICBS provides a barrier to protect SHINE facility sonnel, members of the public, and various components and equipment of the SHINE facility educing radiation exposure. Refer to Section 4a2.5 for information pertaining to ICBS lding requirements. Radiation monitoring of the ICBS general area is provided as discussed ection 7.7.
LS does not discharge radioactive liquid effluent from the facility; therefore, there are no liquid ent monitors. Monitoring of closed loop process cooling water systems to detect cooling er leakage between primary and secondary circuits due to failures in heat exchangers and er system boundaries is provided.
discussed in Subsection 5a2.2.2, PCLS piping penetrating confinement boundaries are vided with isolation capabilities. Automatic isolation valves on the PCLS supply and return s exiting the IU cell are closed as part of an IU Cell Safety Actuation if the TSV reactivity ection system (TRPS) detects an outleakage of target solution into the primary cooling water.
hermore, the PCLS equipment is located inside the primary cooling room and IU cell, which shielded by ICBS. These design features limit exposure of personnel to radioactivity.
PCLS is a closed loop system and is operated at a higher pressure than the TSV to reduce potential for leakage of the target solution into the PCLS in the event of a breach. In the event ressurization of the primary system boundary, potential leakage from the TSV would be tained within the PCLS. Table 11.1-9 identifies the various locations, types, and expected NE Medical Technologies                    5a2.5-2                                          Rev. 0
 
.5.6    TECHNICAL SPECIFICATIONS re are no technical specification parameters identified for the PCLS cleanup loop.
NE Medical Technologies                  5a2.5-3                                  Rev. 0
 
facility demineralized water system (FDWS) provides makeup water to the primary closed cooling system (PCLS), radioisotope process facility cooling system (RPCS), facility chilled er system (FCHS), molybdenum extraction and purification system (MEPS) hot water loop system, light water pool, and process chilled water system (PCHS). The FDWS provides a er supply to the radiological ventilation zone 2 (RVZ2) system and the facility ventilation zone VZ4) system for humidity control. The quality control and analytical testing laboratories BS) and the facility chemical reagent system (FCRS) are supplied demineralized water from FDWS. Operational cooling water loss in the PCLS and light water pool occurs gradually from olysis and evaporation. Water loss in the PCLS, RPCS, FCHS, MEPS hot water subsystem, PCHS may also occur from off-normal events such as leaks or for maintenance. Makeup the FDWS to the systems served is supplied through piping that contains backflow vention. Transfers of makeup water from the FDWS to the cooling and heating systems are ormed manually. Refer to Figure 5a2.6-1 for a flow diagram of the FDWS.
FDWS is supplied water from the facility potable water system (FPWS). The FDWS consists reverse osmosis (RO) skid located outside of the radiologically controlled area (RCA). The skid is a packaged unit that contains pre-filters, piping, valves, pumps, and RO membranes upply RO water. The RO skid is located downstream of the backflow prevention device that as the system boundary between the FPWS and the FDWS. A portion of the demineralized er processed through the RO membrane is supplied to end users outside the RCA requiring treated water with the balance supplied to the RO storage tank located inside the RCA. A ond backflow prevention device is provided at the boundary where the FDWS enters the A.
FDWS includes two 100% capacity pumps. The two pumps are supplied water from the RO age tank that has been filtered by the RO membrane on the RO skid. The pumps circulate er from the RO storage tank to a ring header inside the RCA and back to the tank. Only one p is required to be operational for system service. Recirculated water is supplied directly to users requiring RO-processed water, and through deionizers to other end users requiring nized water. Table 5a2.6-1 identifies the RO-processed and deionized water end users.
FDWS components are listed in Table 5a2.6-2, including design codes and standards.
w from the RO skid is controlled by level instrumentation in the RO storage tank. Tank level is vided with high- and low-level alarms. Pressure is monitored at the outlet of the circulation p where high- and low-level alarms are provided. Sampling and trending of the system is ormed to detect malfunctions in the deionizer units and the RO skid. Sampling and trending ve to identify when replacement or repair is necessary.
FDWS is not safety-related. On loss of normal power, the pumps will not be operational, as FDWS is not relied on to provide water on loss of normal power.
NE Medical Technologies                    5a2.6-1                                        Rev. 0
 
Table 5a2.6 FDWS End Users verse Osmosis Water End Users ility chilled water system (FCHS) ility chemical reagent system (FCRS) servicing the chemical storage room ality control and analytical testing laboratories (LABS) in the Wet and Instrument Laboratories cess chilled water system (PCHS) dioisotope process facility cooling system (RPCS) diological ventilation zone 2 (RVZ2) ility ventilation zone 4 (FVZ4) onized Water End Users molybdenum extraction and purification system (MEPS) hot water loop subsystem ility chemical reagent system (FCRS) servicing the chemical storage room ality control and analytical testing laboratories (LABS) in the Wet and Instrument Laboratories mary closed loop cooling system (PCLS) ht water pool system (LWPS)
NE Medical Technologies                    5a2.6-2                                    Rev. 0
 
Table 5a2.6 FDWS Components Component                      Description                    Code/Standard cility demineralized    The RO skid is a packaged unit that    Note(a) ter system (FDWS)      contains pre-filters, piping, valves, verse osmosis (RO)      pumps, and RO membranes.
id WS deionizer units      Provided to house deionization resins  Note(a) for the removal of contaminants and the reduction of water conductivity.
WS RO storage tank      Provided to maintain adequate RO        Note(a) system supply volumes.
WS pumps                Circulates FDWS RO water through        Note(a) system components.
ping components          FDWS piping.                            ASME B31.9 (ASME, 2011) strumentation            Provide indication of FDWS operating    Note(a) parameters (pressure, temperature, conductivity, flow, and level).
ommercially available equipment designed to standards satisfying system operation.
NE Medical Technologies                  5a2.6-3                                  Rev. 0


Proprietary Information - Withheld from public disclosure under 10 CFR 2.390(a)(4)Export Controlled Information - Withheld from public disclosure under 10 CFR 2.390(a)(3)Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-1Rev. 05a2.2PRIMARY CLOSED LOOP COOLING SYSTEM5a2.2.1DESIGN BASES AND FUNCTIONAL REQUIREMENTSThe primary closed loop cooling system (PCLS) provides forced convection water cooling to the target solution vessel (TSV) and neutron multiplier during irradiation of the target solution and immediately prior to transferring target solution from the TSV to the TSV dump tank. The PCLS also provides indirect cooling of the light water pool via natural convection heat transfer to the PCLS components submerged in the pool, as described in Subsection4a2.7.3. The PCLS rejects heat to the radioisotope process facility cooling system (RPCS). A total of eight independent instances of PCLS are installed in the SHINE facility, one for each irradiation unit (IU). There are no common pressure retaining components between the instances of PCLS. The major PCLS equipment is located in the primary cooling room and the IU cell. Each instance of PCLS includes two pumps, a heat exchanger, and a cooling water clean-up side stream located in the primary cooling rooms adjacent to the east side of each IU cell. In the IU cell, the PCLS is connected to the subcritical assembly system (SCAS) and includes an air separator, an expansion tank, and nitrogen-16 (N-16) delay tanks. Figure5a2.2-1 provides a PCLS flow diagram.The process functions of the PCLS cooling system are to:*remove heat from each TSV and neutron multiplier during full-power IU operation; *cool the light water pool by natural convection heat transfer to PCLS components inside the light water pool;*maintain water quality to reduce corrosion and scaling;
Chapter 5 - Cooling Systems                                                                  Facility Demineralized Water System Figure 5a2.6 Facility Demineralized Water System Flow Diagram SHINE Medical Technologies                                5a2.6-4                                                           Rev. 0
*limit concentrations of particulate and dissolved contaminants that could be made radioactive by neutron irradiation;*reduce N-16 radiation exposure within the primary cooling room in support of as low as reasonably achievable (ALARA) goals; and*remove entrained gases from the cooling water. PCLS removes heat from the TSV and neutron multiplier during startup and irradiation by circulating water in an upward direction [        ]PROP/ECI along the exterior surfaces of the TSV and neutron multiplier walls. The subcritical assembly support structure (SASS) provides the shell side pressure boundary to direct the cooling water flow past the TSV and neutron multiplier. The PCLS is attached to the SASS upper and lower plenums. PCLS is designed to remove a minimum of 580,000 British thermal units per hour (Btu/hr) (170kilowatts [kW]) of heat from each IU during full-power operation and during shutdown conditions when target solution is in the TSV.
PCLS is designed to maintain the pressure of the cooling wa ter in the SASS higher than the internal pressure of the TSV. The TSV is designed and fabricated to prevent target solution from leaking into the PCLS. See Section 4a2.4 for additional information related to the TSV. The PCLS cleanup side stream maintains system cooling water quality. The PCLS is designed to operate without corrosion inhibiting chemicals in the process fluid. The cleanup side stream can Proprietary Information - Withheld from public disclosure under 10 CFR 2.390(a)(4)Export Controlled Information - Withheld from public disclosure under 10 CFR 2.390(a)(3)Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-2Rev. 0divert a portion of the PCLS flow to continuously remove particulates and ions from the cooling water. See Section5a2.5 for additional information related to the PCLS cleanup side stream.The PCLS piping confines the cooling water within the IU cell and within the primary cooling room located adjacent to the IU cell. Pressure retaining components are constructed of materials that effectively resist corrosion to limit activation products that could cause increased radiation exposure of personnel and surrounding equipment. Major components are constructed of austenitic stainless steel.The PCLS air separator separates entrained gases from the cooling water and directs the gases to the radiological ventilation zone 1 exhaust (RVZ1e) subsystem via the PCLS expansion tank. N-16 is generated in the cooling water by the neutron activation of oxygen. Section5a2.7 provides a discussion of the treatment of N-16 in the cooling water.Overpressure protection for PCLS is provided by system design. The shutoff head of the PCLS pumps is below the PCLS design pressure. The PCLS is also directly vented to RVZ1e through the PCLS expansion tank.
See Table5a2.2-1 for the PCLS operating parameters. See Table5a2.2-2 for a list of the PCLS components.5a2.2.2PCLS ANALYSES Detailed analysis of the PCLS target solution cooling performance is found in Section 4a2.7. Heat transfer and temperature profiles for the neutron multiplier are found in Subsection 4a2.2.6
.If active cooling to the TSV and neutron multiplier is unavailable, irradiation of the target solution will be suspended. Target solution in the TSV will be transferred from the TSV to the TSV dump tank, which is passively cooled by the light water pool. See Subsection 4a2.4.2.2 for the heat removal capacity of the light water pool. Loss of cooling design basis accidents are discussed in Subsection13a2.1.3
.Two PCLS pumps operate in parallel to provide the design flowrate to the PCLS heat exchanger. Should one pump fail, the second pump, operating at a minimum of [
        ]PROP/ECI, provides adequate cooling to allow continuation of full-power irradiation while maintaining the bulk target solution temperature less than 176&deg;F (80&deg;C) within the TSV. The light water pool and TSV are located within the primary confinement, which also provides confinement of the components of the PCLS located within the IU cell, as discussed in Section6a2.2. The PCLS piping penetrations through primary confinement are located above the minimum acceptable water level in the pool. Shielding to protect workers and reduce dose rates to equipment is provided by the irradiation cell biological shield (ICBS), described in detail in Section4a2.5. Effects resulting from a primary cooling water breach are discussed in Subsection 4a2.7.3.7. Loss of primary cooling water does not result in loss of integrity of the primary system boundary (PSB). Low cooling water flow causes an IU Cell Safety Actuation, which results in the TSV dump valves opening and the target solution draining to the TSV dump tank. The thermal mass of the Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-3Rev. 0target solution prevents boiling of the solution during the draining process. Once the target solution has drained to the TSV dump tank, the light water pool prevents the solution from boiling by natural convection heat transfer. See Subsection 4a2.7.3.8 for further discussion on the transition from forced to natural convection.Voiding of the SCAS cooling channels caused by loss of primary cooling water causes reactivity insertions as discussed in Subsection13a2.1.2. To prevent the drainage of primary cooling water from the SCAS, the SCAS is located below grade in the light water pool. Portions of the PCLS located outside of the light water pool are above grade to prevent gravity drainage of the SCAS cooling channels. The PCLS pumps draw cooling water from a line connected to the PCLS expansion tank. Because the expansion tank is vented, a leak of the PCLS pressure boundary would result in the PCLS expansion tank level reducing until the PCLS return line breaks vacuum. Once the PCLS return line breaks vacuum, the PCLS pumps cannot draw more water out of the SCAS. This arrangement ensures that the PCLS pumps cannot draw the water out of the SCAS cooling channels. The use of centrifugal pumps and an air separator prevents the PCLS from effectively voiding the cooling channels by pumping air into the SCAS.Malfunctions or leaks in the PCLS do not cause uncontrolled release of primary cooling water outside the radiologically controlled area (RCA). The facility structure (FSTR) provides barriers at exits from the RCA to prevent the release of potentially contaminated water to the uncontrolled environment. The PCLS piping penetrating confinement boundaries are provided with isolation capabilities. Piping systems that pass between confinement boundaries are equipped with either:*a locked closed manual isolation valve, or*an automatic isolation valve that takes the position that provides greater safety upon loss of actuating power.Manual isolation valves are maintained locked-shut for any conditions requiring confinement boundary integrity. The automatic isolation valves are closed as part of an IU Cell Safety Actuation if the TSV reactivity protection system (TRPS) detects a malfunction of PCLS, inleakage of primary cooling water into the PSB, or outleakage of target solution into the primary cooling water. 5a2.2.3INSTRUMENTATION AND CONTROLPressure, flow, temperature, conductivity, and level instrumentation monitor the operating parameters of the PCLS.Temperature instrumentation is provided to ensure the cooling water supply temperature remains within allowable limits despite variations in TSV power. Output from the temperature instrumentation is used for controlling the flow of RPCS water through the PCLS heat exchanger to regulate the cooling water supply temperature at the SCAS cooling water inlet.
Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-4Rev. 0Flow instrumentation is provided to monitor the flowrate of the PCLS cooling water. The PCLS is normally operated as a constant flowrate system during irradiation. However, the PCLS may operate with either one or both pumps operating. If the PCLS temperature or flowrate is outside allowable limits, the TRPS initiates an IU Cell Safety Actuation, resulting in a transfer of the target solution to the TSV dump tank where it is cooled by natural convection to the light water pool. Expansion tank level instrumentation provides indication of loss of cooling water, such as by evaporation or radiolysis. Addition of makeup cooling water is a manual operation. Expansion tank level instrumentation can also perform a leak detection function as described in Subsection5a2.2.6
.Conductivity instrumentation is provided to measure the conductivity of the PCLS water and monitor the performance of the PCLS cleanup side stream. Conductivity instrumentation can also perform a leak detection function as described in Subsection5a2.2.6
.The PCLS pressure, flow, temperature, and expansion tank level indications are available locally and in the control room. Sampling and analysis of cooling water from the PCLS is performed locally. System operational controls are in the control room. 5a2.2.4RADIATION MONITORS AND SAMPLINGThe RVZ1e line ventilating the PCLS expansion tank headspace is equipped with radiation monitors. The RVZ1e radiation monitors are intended to detect leakage of target solution or fission product gases from the PSB or neutron multipliers. If radiation exceeding a predetermined setpoint is detected, the TRPS initiates an IU Cell Safety Actuation and the RVZ1e line is isolated.Sampling and analysis of the water from the PCLS is performed to ensure that the water quality requirements are being maintained and contaminants are not present in the cooling water. Maintaining water quality ensures functional and safe operation by reducing corrosion damage and scaling. See Table5a2.2-1 for water quality requirements. Sampling of cooling water for radiological contaminants is performed to detect possible leakage of target solution into the PSB. 5a2.2.5PCLS INTERFACESThe system interfaces of the PCLS are listed in Table5a2.2-3
.The PCLS cooling water is pumped through the PCLS heat exchanger, where the heat is transferred to the RPCS and subsequently transferred to the process chilled water system (PCHS), where it is dissipated to the environment.The PCLS cooling water leaves the SCAS and enters the PCLS air separator, which allows entrained radiolytic gas to separate from the cooling water. Besides hydrogen and oxygen, the headspace contains air, water vapor, and small amounts of N-16 and argon-41 (Ar-41). An interface between the RVZ1e and the expansion tank allows radiolytic gases to be purged to RVZ1e, preventing the buildup of hydrogen gas. Ambient air from within the primary confinement boundary is drawn through a flame arrestor and filter for sweeping of the expansion tank headspace.
Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-5Rev. 0Makeup water is added manually from the facility demineralized water system (FDWS), as described in Section5a2.6. The PCLS piping includes backflow prevention components at the interface with the FDWS. This prevents possibly contaminated PCLS cooling water from coming in contact with the makeup water. The backflow prevention components help ensure the ALARA guidelines in Chapter 11 are met.5a2.2.6LEAK DETECTION Leak detection is provided by the PCLS expansion tank level instrumentation, TSV dump tank level instrumentation, and conductivity instrumentation. Leak detection is also provided by radiation monitoring and sampling, as discussed in Subsection5a2.2.4
.The expansion tank includes level instruments that allows operators to trend levels within the PCLS, which can indicate slow leaks of cooling water. Additionally, level indication in the TSV dump tank provides indi cation of inleakage of cooling water into the PSB. If inleakage into the PSB is detected, the TRPS initiate s an IU Cell Safety Actuation.Conductivity instrumentation can detect increases in conductivity of the PCLS cooling water resulting from inleakage of target solution.5a2.2.7HYDROGEN LIMITSRadiolysis of the primary cooling water and the light water pool water results in the generation of hydrogen and oxygen gases. These gases must be vented to prevent the buildup of hydrogen. The RVZ1e draws air from the primary confinement and through the PCLS expansion tank headspace to dilute hydrogen within the primary confinement and expansion tank while the PCLS system is required to be in operation. During full-power irradiation, up to approximately 0.15 standard cubic feet per hour (scfh) (70standard cubic centimeters per minute [sccm]) of hydrogen gas is calculated to be generated in the primary cooling water and up to approximately 0.38 scfh (180 sccm) of hydrogen is calculated to be generated in the light water pool.RVZ1e provides a nominal flowrate of approximately 1 standard cubic feet per minute (scfm) (28standard liter per minute [slpm]) to the expansion tank headspace while the PCLS system is required to be in operation. The relatively low nominal flowrate maintains hydrogen concentrations within the primary confinement and expansion tank below 1 percent by volume while minimizing release of Ar-41 to the facility stack. Rates of Ar-41 production and release are described in Section 11.1
.5a2.2.8TECHNICAL SPECIFICATIONS Certain material in this section provides information that is used in the technical specifications. This includes limiting conditions for operation, setpoints, design features, and means for accomplishing surveillances. In addition, significant material is also applicable to, and may be used for the bases that are described in the technical specifications.
Proprietary Information - Withheld from public disclosure under 10 CFR 2.390(a)(4)Export Controlled Information - Withheld from public disclosure under 10 CFR 2.390(a)(3)Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-6Rev. 0Table 5a2.2 PCLS Operating ParametersPCLS ParameterNominal ValuesCooling MediumWaterCooling Medium Makeup SourceFacility demineralized water system (FDWS)Heat Exchanger Duty580,000 Btu/hr (170 kW) per irradiation unit (IU) cellCooling Medium Supply Temperature59&deg;F to 77&deg;F (15&deg;C to 25&deg;C)Cooling Medium Flow RateMinimum flow rate: [                                              ]PROP/ECINominal flow rate: [              ]PROP/ECICooling Medium QualityConductivity: < 5 micromho per centimeter (&#xb5;mho/cm)pH: 5.5 to 7.5System TypeForced cooling water, closed loopSystem Design Pressure100 pounds per square inch (psi)
System Design Temperature200&deg;F (93&deg;C)Material of Construction and FabricationMajor components are fabricated from austenitic stainless steel Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-7Rev. 0a) Commercially available equipment designed to standards satisfying system operation.Table 5a2.2 PCLS ComponentsComponentFunctionsCode/StandardPCLS heat exchangerTransfers heat from PCLS cooling loop to the RPCS ASME BPVC, Section VIII, Division 1 (ASME, 2010)PCLS expansion tankProvides thermal expansion protection and pump head, and facilitates cooling loop level monitoring ASME BPVC Section VIII, Division 1 (ASME, 2010)Piping componentsPCLS cooling loop pipingASME B31.3 (ASME, 2013)Nitrogen-16 (N-16) delay tanksAllows for the decay of N-16 that is generated in the cooling water by neutron activation of oxygen and for the decay of the gaseous flow path from the PCLS air separator ASME B31.3 (ASME, 2013)PCLS pumpsCirculates PCLS cooling water through system components Note (a) PCLS instrumentationProvides indication of PCLS operating parameters See Chapter 7 for safety-related instrumentation See Note (a) for nonsafety-related instrumentationPCLS air separatorAllows entrained radiolytic gas to leave the cooling water and enter into the expansion tank where it is vented to prevent the buildup of hydrogen in the system ASME BPVC Section VIII, Division 1 (ASME, 2010)PCLS flame arrestor with filterPrevents the ignition of hydrogen in the PCLS expansion tank if RVZ1e flow through the expansion tank is lost Note (a) PCLS deionizer bedRemoves dissolved ions from the PCLS cooling water Note (a)
Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-8Rev. 0Table 5a2.2 PCLS System InterfacesSystemInterface DescriptionRadioisotope process cooling water system (RPCS)The RPCS interfaces with each of the eight instances of PCLS inside the radiologically controlled area (RCA). Nonsafety-related manual isolation valves are located at the interface with PCLS.Facility demineralized water system (FDWS)The FDWS interfaces with each of the eight PCLS cooling loops inside the RCA. The FDWS interfaces with the PCLS downstream of a FDWS vacuum breaker. Nonsafety-related manual isolation valves are located at the interface with PCLS.
Subcritical assembly system (SCAS)The SCAS interfaces with the PCLS in each of the eight light water pools located in the irradiation facility (IF). Normal electrical power supply system (NPSS)The NPSS provides power to PCLS process skid, including pumps and instrumentation, located inside the IF.Uninterruptible electrical power supply system (UPSS)The UPSS provides the PCLS safety-related instrumentation with electrical power during normal conditions and during and following design basis events. TSV reactivity protection system (TRPS)The PCLS provides instrumentation for the TRPS to monitor variables important to the safe operation of the PCLS. The TRPS provides controls to the PCLS components to perform safety actuations when monitored variables exceed predetermined limits.Facility compressed air system (FCAS)The FCAS provides compressed gas to the PCLS loop pneumatic control mechanisms located inside the IF.Process integrated control system (PICS)The PICS monitors and controls the PCLS process parameters, utilizing the instrumentation and controlled components within the IF.Radiological ventilation zone 1 (RVZ1)The RVZ1 provides an exhaust path from the headspace of each of the eight PCLS expansion tanks. The PCLS removes radiolytic gas from the cooling water and vents it to prevent combustible gas


mixtures from forming.Radiological ventilation zone 2 (RVZ2)The RVZ2 provides an indirect source of makeup air into the PCLS expansion tanks via the supply air provided to the IF through the primary confinement.
ogen-16 (N-16) is generated in the PCLS and light water pool by the neutron activation of gen. The N-16 control is provided by the primary closed loop cooling system (PCLS) delay ks. As shown in Figure 5a2.2-1, one liquid delay tank is located downstream of the air arator, in the PCLS cooling loop flow path, and the other is a gaseous delay tank located nstream of the PCLS expansion tank, inside the primary confinement boundary.
Chapter 5 - Cooling SystemsPrimary Closed Loop Cooling SystemSHINE Medical Technologies5a2.2-9Rev. 0Figure 5a2.2 Primary Closed Loop Cooling System Flow Diagram
N-16 delay tanks provide additional holdup time to allow for sufficient decay of N-16 prior to ing the shielding to meet with as low as reasonably achievable (ALARA) goals and the ation protection program. In addition, to allowing a portion of the N-16 to decay, a reduction in lding wall thickness is realized as well as a reduction in the PCLS equipment radiation rance requirements.
PCLS uses an air separator to remove entrained gases from the cooling water flow path.
PCLS air separators are vented to the headspace of the corresponding IU cell expansion inside the primary confinement boundary. The headspace of the PCLS expansion tank epts separated gases, including N-16, and directs those gases to the gaseous delay tank, ugh the primary confinement boundary, and into the radiological ventilation zone 1 exhaust Z1e). Redundant safety-related isolation valves are provided on the flow path between the eous N-16 delay tank and the RVZ1e interface with the PCLS.
section 11.1.1 provides a discussion of airborne and liquid radiation sources at the SHINE lity, including N-16.
NE Medical Technologies                    5a2.7-1                                        Rev. 0


Chapter 5 - Cooling SystemsRadioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-1Rev. 05a2.3RADIOISOTOPE PROCESS FACILITY COOLING SYSTEM5a2.3.1DESIGN BASES AND FUNCTIONAL REQUIREMENTSThe radioisotope process facility cooling system (RPCS) removes heat generated from within the radiological control area (RCA) and rejects the heat to the process chilled water system (PCHS). The RPCS is an intermediate closed-loop forced liquid cooling system that recirculates cooling water. The RPCS removes heat from the primary closed loop cooling system (PCLS), the neutron driver assembly system (NDAS) cooling cabinets, the target solution vessel off-gas system (TOGS), the recirculating heating, ventilation, and air conditioning (HVAC) fan-coil units that are part of the radiological ventilation zone 1 recirculating cooling system (RVZ1r), the recirculating HVAC fan-coil units that are part of the radiological ventilation zone 2 recirculating cooling system (RVZ2r), the targ et solution preparati on system (TSPS), the process vessel vent system (PVVS), and the molybdenum extraction and purification system (MEPS). The total demand placed on the RPCS by other systems is approximately 11.6 million British thermal units per hour (MMBtu/hr) (3400 kilowatts [kW]). The RPCS consists of a heat exchanger, pumps, system expansion tank, valves, instrumentation, and heat exchanger interfaces identified above. The RPCS major equipment is located in the RPCS room, within the RCA. The process functions of the RPCS are to:*maintain higher pressure than the cooling systems served at the respective interfaces;*remove process heat from systems served;
primary closed loop cooling system (PCLS) provides cooling to the target solution vessel V) and the neutron multiplier. SHINE facility auxiliary systems do not utilize the PCLS for ling duty.
*maintain cooling water quality to reduce corrosion and scaling; and*reject heat to the PCHS.The RPCS is a nonsafety-related system and is not credited with preventing or mitigating any design basis events. See Figure5a2.3-1 for the process flow diagram of the RPCS. See Table5a2.3-1 for the RPCS design and operating parameters. See Table5a2.3-2 for the RPCS components.5a2.3.2RPCS ANALYSES The cooling function of the RPCS is not credited in the safety analysis for any system served by the RPCS. If active cooling to the TSV and neutron multiplier is unavailable due to a loss of the RPCS, irradiation of the target solution will be suspended. Any target solution in the TSV will be transferred from the TSV to the TVS dump tank which is passively cooled by the light water pool. Section4a2.4 provides a discussion of the heat removal capacity of the light water pool. Loss of cooling design basis accidents are discussed in Subsection 13a2.1.3
NE Medical Technologies                  5a2.8-1                                         Rev. 0
.A pressure cascade is maintained at each system heat exchanger that receives service such that the RPCS cooling water is maintained at a higher pressure than those systems with the potential to contaminate the RPCS. Additionally, the PCHS is maintained at a higher pressure than the RPCS at the RPCS heat exchanger so that any leakage between the RPCS and the PCHS will tend to leak into the RPCS. Makeup water to the RPCS is from the facilit y demineralized water system (FDWS) as described in Section5a2.6. The RPCS piping includes backflow prevention components at the interface with the FDWS. This prevents potentially contaminated RPCS cooling water from contacting the Chapter 5 - Cooling SystemsRadioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-2Rev. 0makeup water. The air-gap backflow prevention components help ensure the as low as reasonably achievable (ALARA) guidelines in Chapter 11 are met. 5a2.3.3INSTRUMENTATION AND CONTROL The process integrated control system (PICS) monitors the RPCS pressure, flow, temperature, and conductivity to ensure operation within design parameters. Instrumentation is located in the RPCS loop to obtain accurate system operating information. Setpoints ensure that operators are alerted when operating conditions are out of specification. Pressure, flow, and temperature are monitored within the RPCS to ensure that the system is operating within design conditions. Flow control is provided on the downstream side of each interfacing systems heat exchanger.A conductivity analyzer is located near the RPCS heat exchanger and pump to monitor the conductivity of the RPCS cooling water. If the conductivity measurement is out of system operable parameters, operators are alerted such that the appropriate corrective actions can be taken. This protection limits corrosion and scaling damage in the RPCS system. Pressure, flow, and temperature instrumentation on the supply and return lines of the RPCS can indicate a malfunction in the system with an increase in pressure drop and/or low system flow. See Table5a2.3-1 for the RPCS operating parameters.The heat removal provided by RPCS to the PCLS is controlled by adjusting the RPCS flow rate to each heat exchanger. The RPCS flow rate is controlled on the return side of the process system heat exchanger by means of a modulating flow control valve. This arrangement ensures that the pressure differential between the RPCS and the PCLS is maintained, regardless of the position of the temperature control valves.5a2.3.4RADIATION MONITORS AND SAMPLINGThe design of the cooling system ensures that release of radioactivity through the secondary cooling system to the unrestricted environment will not lead to potential exposures to the public in excess of the requirements of 10 CFR 20 and the ALARA program guidelines. The RPCS is maintained at a higher pressure than the systems served. Furthermore, the RPCS is a closed loop system located inside the RCA. The facility structure (FSTR) provides barriers at exits from the RCA to prevent the release of potentially contaminated cooling water to the uncontrolled environment.Sampling and analysis of cooling water from the RPCS is performed to ensure radiological contaminants are below acceptable limits. If unacceptable levels of contamination are found, the system will be shut down and the contaminated cooling water will be purified using ion exchange beds. Operators then inspect the malfunctioning equipment and remedy the issue accordingly.Sampling and analysis of the cooling water from the RPCS is also performed to ensure that the water quality requirements are being maintained. Maintaining cooling water quality minimizes the potential for damage due to corrosion and scaling. Table5a2.3-1 describes the RPCS cooling water quality requirements.
Chapter 5 - Cooling SystemsRadioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-3Rev. 05a2.3.5OTHER INTERFACESThe RPCS components are listed in Table5a2.3-2, including design codes and standards. The RPCS interfaces with the PCHS at the RPCS heat exchanger located within the RCA boundary.
The system interfaces of the RPCS are listed in Table5a2.3-3
.5a2.3.6TECHNICAL SPECIFICATIONS There are no technical specification parameters identified for the RPCS.
Chapter 5 - Cooling Systems Radioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-4Rev. 0Table 5a2.3 RPCS Operating ParametersParameterNominal ValueCooling MediumWaterCooling Medium Makeup Source FDWS Supply ConditionsTemperature: 40&deg;F to 44&deg;F (4.5&deg;C to 6.5&deg;C)Return Conditions Temperature: 60&deg;F to 64&deg;F (15.5&deg;C to 17.5&deg;C)Design Pressure100 pounds per square inch (psi) Design Temperature200&deg;F (93&deg;C)Heat Exchanger Duty11.6 MMBtu/hr (3400 kW)Cooling Medium Flow RateVolumetric flow rate: < 3000 gallons per minute (gpm)Cooling Medium Quality Conductivity: < 2000 &#xb5;mho/cmpH: 6 to 8.
Based on recommendations for secondary cooling water parameters in IAEA No. NP-T-5.2 (IAEA, 2011).System TypeRPCS is a forced liquid, closed loop cooling system circulating water to remove heat from PCLS and other process and non-process systems via heat exchangers.Material of Construction and FabricationRPCS components are designed and fabricated in accordance with the codes and standards listed in Table 5a2.3-2.
Chapter 5 - Cooling Systems Radioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-5Rev. 0a) Commercially available equipment designed to standards to satisfy system operation.Table 5a2.3 RPCS ComponentsComponentDescriptionCode/StandardRPCS heat exchangerTransfers heat from RPCS to PCHS.Note (a) RPCS expansion tankProvides thermal expansion protection for the RPCS piping and components.
Note (a) RPCS buffer tankProvided to increase the system volume to levels required to maintain system loop times.
Note (a) Piping componentsRPCS piping.ASME B31.9 (ASME, 2017)RPCS pumpCirculates RPCS water through system components.
Note (a) RPCS instrumentationProvide indication of RPCS operating parameters (pressure, temperature, flow, and level).
Note (a)
Chapter 5 - Cooling Systems Radioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-6Rev. 0Table 5a2.3 RPCS Interfaces (Sheet 1 of 2)SystemInterface DescriptionPrimary closed loop cooling system (PCLS)The RPCS interfaces with each of the eight PCLS cooling loops inside the RCA. Nonsafety-related manual isolation valves are located at the interface with PCLS.TSV off-gas system (TOGS)Interfaces at the TOGS cooling water supply and return connections inside the RCA to condense water vapor and remove heat from recombiner condensers and condenser-demisters. Nonsafety-related manual isolation valves are located at the interface with TOGS.Molybdenum extraction and purification system (MEPS)Interfaces at the evaporator supply and return connections inside the RCA to facilitate condensation of water vapor. Nonsafety-related manual isolation valves are located at the interface with MEPS.Process vessel vent system (PVVS)Interfaces at the supply and return connections of the PVVS cooler and condensers within the RPF section of the RCA to reduce the PVVS process temperature and relative humidity. Nonsafety-related manual


isolation valves are located at the interface with PVVS.Process chilled water system (PCHS)Interfaces at the supply and return connections of the RPCS heat exchanger inside the RCA and transfers heat from the RPCS to the PCHS so it can be released to the environment exterior to the RCA boundary. Nonsafety-related manual isolation valves are located at the interface with PCHS.Target solution preparation system (TSPS)Interfaces at the supply and return connections of the TSPS reflux condensers inside the RCA to mitigate liquid loss during dissolution. Nonsafety-related manual isolation valves are located at the interface with TSPS.Radiological ventilation Zone 1 recirculating cooling subsystem (RVZ1r)Interfaces at the supply and return connections of the IU supplemental cooling system fan coil, exterior to the primary confinement boundary, inside the RCA. Nonsafety-related manual isolation valves are located at the interface with RVZ1r.Radiological ventilation Zone 2 recirculating cooling subsystem (RVZ2r)Interfaces at the supply and return connections of the recirculating unit fan coils inside the RCA. Nonsafety-related manual isolation valves are located at the interface with RVZ2r.Facility demineralized water system (FDWS)Interfaces upstream of the RPCS pumps inside the RCA to supply makeup water to the RPCS.Neutron driver assembly system (NDAS)Interfaces with each of the nine NDAS cooling cabinets within the RCA to remove heat from the independent NDAS cooling loops.
RI, 2015. Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages ng the Vapor Compression Cycle, AHRI Standard 550/590 (I-P), Air-Conditioning, Heating, Refrigeration Institute, 2015.
Chapter 5 - Cooling Systems Radioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-7Rev. 0Process integrated control system (PICS)PICS monitors and controls RPCS actuators and instrumentation on valves, piping, and components.Normal electrical power supply system (NPSS)The NPSS provides power to RPCS equipment and instrumentation. Table 5a2.3 RPCS Interfaces (Sheet 2 of 2)SystemInterface Description Chapter 5 - Cooling SystemsRadioisotope Process Facility Cooling SystemSHINE Medical Technologies5a2.3-8Rev. 0Figure 5a2.3 Radioisotope Process Facility Cooling System Flow Diagram Chapter 5 - Cooling SystemsProcess Chilled Water SystemSHINE Medical Technologies5a2.4-1Rev. 05a2.4PROCESS CHILLED WATER SYSTEM5a2.4.1DESIGN BASIS AND FUNCTIONAL REQUIREMENTSThe process chilled water system (PCHS) removes heat from the radioisotope process facility cooling system (RPCS) from within the radiologically controlled area (RCA) and rejects the heat to the environment. The PCHS interfaces with the RPCS heat exchanger and is comprised of circulation pumps, flow control valves, an expansion tank, a buffer tank, a glycol makeup unit, instrumentation, and packaged air-cooled chillers. The PCHS is a forced liquid, convective flow, closed loop cooling system that uses air-cooled chillers to facilitate heat rejection to the environment. The PCHS is designed to remove the total heat transfer demand placed on RPCS by other systems. The PCHS is a nonsafety-related system and is not credited with preventing or mitigating any design basis events. Table5a2.4-1 provides the PCHS operating parameters. Table5a2.4-2 provides a description of PCHS components. Figure5a2.4-1 provides a process flow diagram of the PCHS.The process functions of the PCHS are to:*remove heat from the RPCS heat exchangers;*reject heat to the environment;*maintain water quality to reduce corrosion and scaling; and
ME, 2010. Rules for Construction of Pressure Vessels, ASME Boiler and Pressure Vessel e, VIII, Division 1, American Society of Mechanical Engineers, 2010.
*prevent freezing of exterior piping and components.The PCHS is designed for local outdoor operation. The system is operated with a propylene glycol/water mixture through the RPCS heat exchanger. Process generated heat is transferred from the facility process systems into the RPCS inside the RCA. The RPCS transfers this process heat to the PCHS through the RPCS heat exchanger, located inside the RCA. The PCHS then routes the process heat outside the RCA, and ultimately out of the facility to air-cooled chillers. The PCHS is provided makeup water from the facility demineralized water system (FDWS), which is described in Section5a2.6, and glycol through a manual fill point for normal operation. Table5a2.4-1 describes the PCHS water quality requirements.5a2.4.2PROCESS CHILLED WATER SYSTEM ANALYSES The PCHS is designed to remove the total heat transfer demand placed on the RPCS by other systems of approximately 11.6 MMBtu/hr (3400 kW). The PCHS is maintained at a higher pressure than the RPCS to ensure that leakage at the system interface heat exchanger flows from potentially less contaminated cooling water to potentially more contaminated cooling water.5a2.4.3INSTRUMENTATION AND CONTROLThe PCHS provides output signals to the process integrated control system (PICS) for the monitoring of cooling water temperatures, pressures, tank level, and flow rates. Pressure, flow, tank level, and temperature measurement instrumentation are strategically located in the PCHS cooling loop to obtain system operating information. Setpoints ensure that operators are alerted when an operating condition is out of specification. Buffer tank level setpoints are monitored to indicate high or low system volume conditions.
ME, 2013. Process Piping, ASME Code for Pressure Piping, B31, ASME B31.3-2012, erican Society of Mechanical Engineers, 2013.
Chapter 5 - Cooling SystemsProcess Chilled Water SystemSHINE Medical Technologies5a2.4-2Rev. 05a2.4.4RADIATION MONITORS AND SAMPLINGThe RPCS, transfers heat from the PCLS to the PCHS. The PCHS dissipates the heat from the RPCS to the environment. The RPCS is maintained at a lower pressure than PCHS at the RPCS heat exchanger as such any leakage between RPCS and PCHS would tend to leak into RPCS. The PCLS, RPCS, and PCHS are closed loop systems. Samples of cooling water are analyzed for contamination and conductivity. The contaminated volume of cooling water is recycled in either an on-site recycling unit or a mobile service unit. Water quality is maintained to reduce corrosion and scaling in the system. System cooling water level is monitored to provide indication of system in-leakage or out-leakage. These design features ensure that radioactivity is not released through the PCHS to the unrestricted environment and will not lead to potential exposures of the public in excess of the requirements of 10 CFR 20 and the as low as reasonably achievable (ALARA) program guidelines. The system interfaces of the PCHS are listed in Table5a2.4-3
ME, 2017. Building Services Piping, ASME Code for Pressure Piping, B31, ME B31.9-2017, American Society of Mechanical Engineers, 2017.
.5a2.4.5TECHNICAL SPECIFICATIONSThere are no technical specification parameters identified for the PCHS.
A, 2011. Good Practices for Water Quality Management in Research Reactors and Spent l Storage Facilities, IAEA Nuclear Energy Series No. NP-T-5.2, International Atomic Energy ncy, 2011.
Chapter 5 - Cooling SystemsProcess Chilled Water SystemSHINE Medical Technologies5a2.4-3Rev. 0Table 5a2.4 PCHS Operating ParametersPCHS ParameterNominal ValuesCooling mediumPropylene glycol/waterCooling medium make-up sourceFDWS with manual addition of propylene glycolSupply conditionsTemperature: 30&deg;F to 40&deg;F (-1&deg;C to 4.5&deg;C)Return conditions Temperature: 50&deg;F to 60&deg;F (10&deg;C to 15.5&deg;C)Design pressure160 psi Design temperature200&deg;F (93.3&deg;C)EnvironmentDesign dry bulb temperature (DBT) range: -10&deg;F to 91.5&deg;F (-23&deg;C to 33&deg;C)Chiller heat duty11.6 MMBtu/hr (3400 kW)
NE Medical Technologies                    5a2.9-1                                   Rev. 0
Cooling medium flow rateVolumetric flow rate: < 2200 gallons per minute (gpm)System type PCHS is a forced liquid, closed loop cooling system circulating propylene glycol/water. The PCHS removes heat from the RPCS heat exchangers and transfer it to air-cooled chillers located outside of the facility.Material of construction and fabricationPCHS components are designed and fabricated in accordance with the codes and standards listed in Table5a2.4-2. Heat dissipation This system dissipates heat to the environment through air-cooled chillers.
Chapter 5 - Cooling Systems Process Chilled Water SystemSHINE Medical Technologies5a2.4-4Rev. 0a) Commercially available equipment designed to standards to satisfy system operation.Table 5a2.4 PCHS ComponentsComponentDescriptionCode/StandardPCHS chillerTransfers heat from PCHS to the environment.Note (a)PCHS expansion tankProvides thermal expansion protection for the PCHS piping and components.Note (a)PCHS buffer tankProvided to increase the system volume to levels required to maintain system loop times.Note (a)PCHS pumpCirculates PCHS Coolant through system components Note (a)Piping componentsPCHS piping.ASME B31.9 (ASME, 2017)InstrumentationProvide indication of PCHS operating parameters (pressure, temperature, flow, and level). Note (a)
Chapter 5 - Cooling SystemsProcess Chilled Water SystemSHINE Medical Technologies5a2.4-5Rev. 0Table 5a2.4 PCHS System InterfacesSystemInterface DescriptionRadioisotope process cooling system (RPCS)Interfaces at the RPCS heat exchangers inside RCA. The PCHS removes heat from the RCA through the RPCS heat exchangers and rejects the heat to the environment outside the RCA. Atmospheric environmentInterfaces at the PCHS chillers. Transfers heat from the PCHS through air chillers to the environment outside of the RCA boundary.
Chapter 5 - Cooling SystemsProcess Chilled Water SystemSHINE Medical Technologies5a2.4-6Rev. 0Figure 5a2.4 Process Chilled Water System Flow Diagram Chapter 5 - Cooling Systems Primary Closed Loop Cooling System Cleanup Side StreamSHINE Medical Technologies5a2.5-1Rev. 05a2.5PRIMARY CLOSED LOOP COOLING SYSTEM CLEANUP SIDE STREAM5a2.5.1DESIGN BASES AND PROCESS FUNCTIONSThe primary closed loop cooling system (PCLS) cleanup side stream maintains the required water quality limits of the PCLS.The following are the process functions of the PCLS cleanup side stream:*Maintain water quality to reduce corrosion and scaling; and *Limit concentrations of particulate and dissolved contaminants that could be made radioactive by neutron irradiation to achieve as low as reasonably achievable (ALARA) goals.The PCLS cooling water is treated to meet water quality limits discussed in Table5a2.2-1. The cleanup components are located on a side stream through which the PCLS diverts a portion of the cooling water flow
. The components that perform the PCLS cooling water treatment are located within the PCLS cleanup side stream flow path.The PCLS cleanup side stream includes conductivity instrumentation to monitor water quality, deionizer beds to remove ionic species, and filters on the inlet and outlet of the deionizer beds to remove particulates from the cooling water.Maintaining the design water quality limits corrosion damage and scaling of the PCLS, the target solution vessel (TSV), and the neutron multiplier, which are components of the subcritical assembly system (SCAS). The PCLS cleanup side stream removes contaminates that could become activated and radioactive materials from the PCLS cooling water in order to meet ALARA occupational exposure goals described in Section11.1. The PCLS cleanup side stream and its components are designed and selected so that malfunctions are unlikely. Malfunctions and leaks in the PCLS and the PCLS cleanup side streams are addressed in Subsection5a2.2.2
.See Table5a2.2-2 for the list of PCLS components and their functions.The PCLS cleanup side stream components are designed and fabricated in accordance with the codes and standards listed in Table5a2.2-2
.5a2.5.2PCLS CLEANUP SIDE STREAM CONTROL AND INSTRUMENTATIONThe PCLS cleanup side stream instrumentation is located in the primary cooling room.Conductivity instrumentation located at the outlet of the PCLS cleanup side stream measures the conductivity within the PCLS. The pH of the PCLS cooling water is monitored through sampling of the system and analysis of the cooling water is performed by the quality control and analytical testing laboratories (LABS)
. Pressure, flow, temperature, conductivity, and level instrumentation monitor the operating parameters of the PCLS as discussed in Subsection5a2.2.3. 5a2.5.3PCLS CLEANUP SIDE STREAM COMPONENTS AND LOCATIONS The PCLS cleanup side stream components are located in the primary cooling room, directly adjacent to the IU cells.
Chapter 5 - Cooling Systems Primary Closed Loop Cooling System Cleanup Side StreamSHINE Medical Technologies5a2.5-2Rev. 0Flow to the PCLS cleanup side stream is diverted after it exits the PCLS heat exchanger. Flow through the PCLS cleanup side stream is adjusted by means of a flow control valve in the PCLS cleanup side stream. After the PCLS cooling water is diverted to the PCLS cleanup side stream, it first flows through a pre-filter, through a deionizer bed and finally through a post-filter. Following this process, the PCLS cooling water side stream is reintroduced into the PCLS main flow path prior to entering the SCAS.5a2.5.4MAINTENANCE AND TESTINGThe PCLS cleanup side stream pre-filters, post-filters
, and deionizer units are replaced at regular intervals in accordance with maintenance procedures. Spent filters and deionizer units are disposed of as radioactive waste via the solid radioactive waste processing (SRWP) system. Further discussion of SRWP can be found in Section 9b.7
. Subsection 11.2.2 addresses compliance with 10 CFR 20 and presents ALARA guidelines relative to radioactive waste control. Table11.2-1 provides a list of solid radioactive wastes including an estimate of annual quantities generated and disposal destinations.Sampling and testing of the PCLS cooling water is performed as described in Subsection5a2.2.5
.Isolating the PCLS cleanup side stream from the associated PCLS cooling loop for maintenance purposes does not disrupt irradiation unit (IU) operation or prevent safe IU shutdown.5a2.5.5PREDICTING, MONITORING AND SHIELDING RADIOACTIVITYThe PCLS cleanup side stream components are located entirely within the primary cooling room associated with their respective IU cell. Each primary cooling room is located within the irradiation cell biological shield (ICBS). The ICBS provides a barrier to protect SHINE facility personnel, members of the public, and various components and equipment of the SHINE facility by reducing radiation exposure. Refer to Section4a2.5 for information pertaining to ICBS shielding requirements. Radiation monitoring of the ICBS general area is provided as discussed in Section 7.7
.PCLS does not discharge radioactive liquid effluent from the facility; therefore, there are no liquid effluent monitors. Monitoring of closed loop process cooling water systems to detect cooling water leakage between primary and secondary circuits due to failures in heat exchangers and other system boundaries is provided. As discussed in Subsection5a2.2.2, PCLS piping penetrating confinement boundaries are provided with isolation capabilities. Automatic isolation valves on the PCLS supply and return lines exiting the IU cell are closed as part of an IU Cell Safety Actuation if the TSV reactivity protection system (TRPS) detects an outleakage of target solution into the primary cooling water. Furthermore, the PCLS equipment is located inside the primary cooling room and IU cell, which are shielded by ICBS. These design features limit exposure of personnel to radioactivity. The PCLS is a closed loop system and is operated at a higher pressure than the TSV to reduce the potential for leakage of the target solution into the PCLS in the event of a breach. In the event of pressurization of the primary system boundary, potential leakage from the TSV would be contained within the PCLS. Table 11.1-9 identifies the various locations, types, and expected Chapter 5 - Cooling Systems Primary Closed Loop Cooling System Cleanup Side StreamSHINE Medical Technologies5a2.5-3Rev. 0doses from liquid radioactive sources. Section5a2.7 provides a discussion pertaining to control of nitrogen-16.5a2.5.6TECHNICAL SPECIFICATIONS There are no technical specification parameters identified for the PCLS cleanup loop.
Chapter 5 - Cooling Systems Facility Demineralized Water SystemSHINE Medical Technologies5a2.6-1Rev. 05a2.6FACILITY DEMINERALIZED WATER SYSTEMThe facility demineralized water system (FDWS) provides makeup water to the primary closed loop cooling system (PCLS), radioisotope process fa cility cooling system (RPCS), facility chilled water system (FCHS), molybdenum extraction and purification system (MEPS) hot water loop subsystem, light water pool, and process chilled water system (PCHS). The FDWS provides a water supply to the radiological ventilation zone 2 (RVZ2) system and the facility ventilation zone 4 (FVZ4) system for humidity control. The quality control and analytical testing laboratories (LABS) and the facility chemical reagent system (FCRS) are suppl ied demineralized water from the FDWS. Operational cooling water loss in the PCLS and light water pool occurs gradually from radiolysis and evaporation. Wate r loss in the PCLS, RPCS, FCHS, MEPS hot water subsystem, and PCHS may also occur from off-normal events such as leaks or for maintenance. Makeup from the FDWS to the systems served is supplied through piping that contains backflow prevention. Transfers of makeup water from the FDWS to the cooling and heating systems are performed manually. Refer to Figure5a2.6-1 for a flow diagram of the FDWS.The FDWS is supplied water from the facility potable water system (FPWS). The FDWS consists of a reverse osmosis (RO) skid located outside of the radiologically controlled area (RCA). The RO skid is a packaged unit that contains pre-filters, piping, valves, pumps, and RO membranes to supply RO water. The RO skid is located downstream of the backflow prevention device that acts as the system boundary between the FPWS and the FDWS. A portion of the demineralized water processed through the RO membrane is supplied to end users outside the RCA requiring RO treated water with the balance supplied to the RO storage tank located inside the RCA. A second backflow prevention device is provided at the boundary where the FDWS enters the RCA. The FDWS includes two 100% capacity pumps. The two pumps are supplied water from the RO storage tank that has been filtered by the RO membrane on the RO skid. The pumps circulate water from the RO storage tank to a ring header inside the RCA and back to the tank. Only one pump is required to be operational for system service. Recirculated water is supplied directly to end users requiring RO-processed water, and through deionizers to other end users requiring deionized water. Table5a2.6-1 identifies the RO-processed and deionized water end users.The FDWS components are listed in Table5a2.6-2, including design codes and standards.Flow from the RO skid is controlled by level instrumentation in the RO storage tank. Tank level is provided with high- and low-level alarms. Pressure is monitored at the outlet of the circulation pump where high- and low-level alarms are provided. Sampling and trending of the system is performed to detect malfunctions in the deionizer units and the RO skid. Sampling and trending serve to identify when replacement or repair is necessary.The FDWS is not safety-related. On loss of normal power, the pumps will not be operational, as the FDWS is not relied on to provide water on loss of normal power.
Chapter 5 - Cooling SystemsFacility Demineralized Water SystemSHINE Medical Technologies5a2.6-2Rev. 0Table 5a2.6 FDWS End UsersReverse Osmosis Water End UsersFacility chilled water system (FCHS)
Facility chemical reagent system (FCRS) servicing the chemical storage roomQuality control and analytical testing laboratories (LABS) in the Wet and Instrument LaboratoriesProcess chilled water system (PCHS)
Radioisotope process facility cooling system (RPCS)Radiological ventilation zone 2 (RVZ2)Facility ventilation zone 4 (FVZ4)Deionized Water End UsersThe molybdenum extraction and purification system (MEPS) hot water loop subsystemFacility chemical reagent system (FCRS) servicing the chemical storage roomQuality control and analytical testing laboratories (LABS) in the Wet and Instrument Laboratories Primary closed loop cooling system (PCLS)
Light water pool system (LWPS)
Chapter 5 - Cooling SystemsFacility Demineralized Water SystemSHINE Medical Technologies5a2.6-3Rev. 0a) Commercially available equipment designed to standards satisfying system operation.Table 5a2.6 FDWS ComponentsComponentDescriptionCode/StandardFacility demineralized water system (FDWS) reverse osmosis (RO) skid The RO skid is a packaged unit that contains pre-filters, piping, valves, pumps, and RO membranes.
Note (a) FDWS deionizer units Provided to house deionization resins for the removal of contaminants and the reduction of water conductivity.
Note (a) FDWS RO storage tank Provided to maintain adequate RO system supply volumes.
Note (a) FDWS pumps Circulates FDWS RO water through system components.
Note (a) Piping components FDWS piping. ASME B31.9 (ASME, 2011) Instrumentation Provide indication of FDWS operating parameters (pressure, temperature, conductivity, flow, and level).
Note (a)
Chapter 5 - Cooling Systems  Facility Demineralized Water System SHINE Medical Technologies5a2.6-4Rev. 0Figure 5a2.6 Facility Demineralized Water System Flow Diagram Chapter 5 - Cooling Systems Nitrogen-16 ControlSHINE Medical Technologies5a2.7-1Rev. 05a2.7NITROGEN-16 CONTROLNitrogen-16 (N-16) is generated in the PCLS and light water pool by the neutron activation of oxygen. The N-16 control is provided by the primary closed loop cooling system (PCLS) delay tanks. As shown in Figure5a2.2-1, one liquid delay tank is located downstream of the air separator, in the PCLS cooling loop flow path, and the other is a gaseous delay tank located downstream of the PCLS expansion tank, inside the primary confinement boundary. The N-16 delay tanks provide additional holdup time to allow for sufficient decay of N-16 prior to exiting the shielding to meet with as low as reasonably achievable (ALARA) goals and the radiation protection program. In addition, to allowing a portion of the N-16 to decay, a reduction in shielding wall thickness is realized as well as a reduction in the PCLS equipment radiation tolerance requirements. The PCLS uses an air separator to remove entrained gases from the cooling water flow path. The PCLS air separators are vented to the headspace of the corresponding IU cell expansion tank inside the primary confinement boundary. The headspace of the PCLS expansion tank accepts separated gases, including N-16, and directs those gases to the gaseous delay tank, through the primary confinement boundary, and into the radiological ventilation zone 1 exhaust (RVZ1e). Redundant safety-related isolation valves are provided on the flow path between the gaseous N-16 delay tank and the RVZ1e interface with the PCLS. Subsection 11.1.1 provides a discussion of airborne and liquid radiation sources at the SHINE facility, including N-16.
Chapter 5 - Cooling Systems Auxiliary Systems Using Primary CoolantSHINE Medical Technologies5a2.8-1Rev. 05a2.8AUXILIARY SYSTEMS USING PRIMARY COOLANT The primary closed loop cooling system (PCLS) provides cooling to the target solution vessel (TSV) and the neutron multiplier. SHINE facility auxiliary systems do not utilize the PCLS for cooling duty.
Chapter 5 - Cooling Systems ReferencesSHINE Medical Technologies5a2.9-1Rev. 05a


==2.9REFERENCES==
NE cooling systems are integrated throughout the facility as described in Section 5a2. The oisotope process facility cooling system is described in Section 5a2.3.
AHRI, 2015. Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle, AHRI Standard 550/590 (I-P), Air-Conditioning, Heating, and Refrigeration Institute, 2015.ASME, 2010. Rules for Construction of Pressure Vessels, ASME Boiler and Pressure Vessel Code, VIII, Division 1, American Society of Mechanical Engineers, 2010.ASME, 2013. Process Piping, ASME Code for Pressure Piping, B31, ASME B31.3-2012, American Society of Mechanical Engineers, 2013.ASME, 2017. Building Services Piping, ASME Code for Pressure Piping, B31, ASMEB31.9-2017, American Society of Mechanical Engineers, 2017.IAEA, 2011. Good Practices for Water Quality Management in Research Reactors and Spent Fuel Storage Facilities, IAEA Nucl ear Energy Series No. NP-T-5.2, International Atomic Energy Agency, 2011.
NE Medical Technologies                    5b-1                                        Rev. 0}}
Chapter 5 - Cooling Systems Radioisotope Production Facilit y Cooling SystemsSHINE Medical Technologies5b-1Rev. 05bRADIOISOTOPE PRODUCTION FACILITY COOLING SYSTEMSSHINE cooling systems are integrated throughout the facility as described in Section5a2. The radioisotope process facility cooling system is described in Section5a2.3
.}}

Latest revision as of 13:06, 19 October 2019

Shine Medical Technologies, LLC, Final Safety Analysis Report, Chapter 5, Cooling Systems
ML19211C099
Person / Time
Site: SHINE Medical Technologies
Issue date: 07/17/2019
From:
SHINE Medical Technologies
To:
Office of Nuclear Reactor Regulation
References
2019-SMT-0054
Download: ML19211C099 (44)


Text

COOLING SYSTEMS TABLE OF CONTENTS tion Title Page IRRADIATION FACILITY COOLING SYSTEMS .............................................. 5a2.1-1

.1

SUMMARY

DESCRIPTION ............................................................................. 5a2.1-1

.2 PRIMARY CLOSED LOOP COOLING SYSTEM ............................................. 5a2.2-1 5a2.2.1 DESIGN BASES AND FUNCTIONAL REQUIREMENTS ............... 5a2.2-1 5a2.2.2 PCLS ANALYSES .......................................................................... 5a2.2-2 5a2.2.3 INSTRUMENTATION AND CONTROL .......................................... 5a2.2-3 5a2.2.4 RADIATION MONITORS AND SAMPLING ................................... 5a2.2-4 5a2.2.5 PCLS INTERFACES ...................................................................... 5a2.2-4 5a2.2.6 LEAK DETECTION ......................................................................... 5a2.2-5 5a2.2.7 HYDROGEN LIMITS ...................................................................... 5a2.2-5 5a2.2.8 TECHNICAL SPECIFICATIONS .................................................... 5a2.2-5

.3 RADIOISOTOPE PROCESS FACILITY COOLING SYSTEM ......................... 5a2.3-1 5a2.3.1 DESIGN BASES AND FUNCTIONAL REQUIREMENTS .............. 5a2.3-1 5a2.3.2 RPCS ANALYSES .......................................................................... 5a2.3-1 5a2.3.3 INSTRUMENTATION AND CONTROL .......................................... 5a2.3-2 5a2.3.4 RADIATION MONITORS AND SAMPLING ................................... 5a2.3-2 5a2.3.5 OTHER INTERFACES ................................................................... 5a2.3-3 5a2.3.6 TECHNICAL SPECIFICATIONS .................................................... 5a2.3-3

.4 PROCESS CHILLED WATER SYSTEM .......................................................... 5a2.4-1 5a2.4.1 DESIGN BASIS AND FUNCTIONAL REQUIREMENTS ................ 5a2.4-1 5a2.4.2 PROCESS CHILLED WATER SYSTEM ANALYSES .................... 5a2.4-1 5a2.4.3 INSTRUMENTATION AND CONTROL .......................................... 5a2.4-1 NE Medical Technologies 5-i Rev. 0

COOLING SYSTEMS TABLE OF CONTENTS tion Title Page 5a2.4.4 RADIATION MONITORS AND SAMPLING ................................... 5a2.4-2 5a2.4.5 TECHNICAL SPECIFICATIONS .................................................... 5a2.4-2

.5 PRIMARY CLOSED LOOP COOLING SYSTEM CLEANUP SIDE STREAM ................................................................................................. 5a2.5-1 5a2.5.1 DESIGN BASIS AND PROCESS FUNCTIONS ............................. 5a2.5-1 5a2.5.2 PCLS CLEANUP SIDE STREAM CONTROL AND INSTRUMENTATION ..................................................................... 5a2.5-1 5a2.5.3 PCLS CLEANUP SIDE STREAM COMPONENTS AND LOCATIONS ................................................................................... 5a2.5-1 5a2.5.4 MAINTENANCE AND TESTING .................................................... 5a2.5-2 5a2.5.5 PREDICTING, MONITORING AND SHIELDING RADIOACTIVITY ............................................................................ 5a2.5-2 5a2.5.6 TECHNICAL SPECIFICATIONS .................................................... 5a2.5-3

.6 FACILITY DEMINERALIZED WATER SYSTEM ............................................. 5a2.6-1

.7 NITROGEN-16 CONTROL .............................................................................. 5a2.7-1

.8 AUXILIARY SYSTEMS USING PRIMARY COOLANT ................................... 5a2.8-1

.9 REFERENCES ................................................................................................. 5a2.9-1 RADIOISOTOPE PRODUCTION FACILITY COOLING SYSTEMS ..................... 5b-1 NE Medical Technologies 5-ii Rev. 0

.2-1 PCLS Operating Parameters

.2-2 PCLS Components

.2-3 PCLS System Interfaces

.3-1 RPCS Operating Parameters

.3-2 RPCS Components

.3-3 RPCS Interfaces

.4-1 PCHS Operating Parameters

.4-2 PCHS Components

.4-3 PCHS System Interfaces

.6-1 FDWS End Users

.6-2 FDWS Components NE Medical Technologies 5-iii Rev. 0

.1-1 Cooling Systems Heat Flow Pathway Diagram

.2-1 Primary Closed Loop Cooling System Flow Diagram

.3-1 Radioisotope Process Facility Cooling System Flow Diagram

.4-1 Process Chilled Water System Flow Diagram

.6-1 Facility Demineralized Water System Flow Diagram NE Medical Technologies 5-iv Rev. 0

onym/Abbreviation Definition ho/cm micromho per centimeter RA as low as reasonably achievable 1 argon-41 ME American Society of Mechanical Engineers British thermal unit

/hr British thermal units per hour centimeter T dry bulb temperature AS facility compressed air system HS facility chilled water system RS facility chemical reagent system WS facility demineralized water system WS facility potable water system R facility structure 4 facility ventilation zone 4 gallons per minute NE Medical Technologies 5-v Rev. 0

onym/Abbreviation Definition hour AC heating, ventilation, and air conditioning A International Atomic Energy Agency S irradiation cell biological shield irradiation facility irradiation unit kilowatt S quality control and analytical laboratories PS light water pool system WB mean coincident wet bulb temperature PS molybdenum extraction and purification system million 6 nitrogen-16 AS neutron driver assembly system SS normal electrical power supply system LS primary closed loop cooling system NE Medical Technologies 5-vi Rev. 0

onym/Abbreviation Definition HS process chilled water system S process integrated control system B primary system boundary pounds per square inch VS process vessel vent system A radiologically controlled area reverse osmosis CS radioisotope process facility cooling system Z1 radiological ventilation zone 1 Z1e radiological ventilation zone 1 exhaust subsystem Z1r radiological ventilation zone 1 recirculating cooling subsystem Z2 radiological ventilation zone 2 Z2r radiological ventilation zone 2 recirculating cooling subsystem SS subcritical assembly support structure AS subcritical assembly system NE Medical Technologies 5-vii Rev. 0

onym/Abbreviation Definition m standard cubic centimeters per minute standard cubic feet per hour m standard cubic feet per minute m standard liters per minute WP solid radioactive waste processing GS TSV off-gas system PS TSV reactivity protection system S target solution preparation system target solution vessel SS uninterruptible electrical power supply system T wet bulb temperature NE Medical Technologies 5-viii Rev. 0

.1

SUMMARY

DESCRIPTION purpose of the irradiation facility (IF) cooling systems is to safely remove the fission and ay heat from the target solution and dissipate it to the environment. The primary closed loop ling system (PCLS) removes heat from the subcritical assembly. The light water pool vides passive heat removal for the subcritical assembly and is described in detail in tion 4a2.4. The radioisotope process facility cooling system (RPCS) is the secondary cooling tem for the facility. See Chapter 13 for a discussion of accident scenarios.

target solution vessel (TSV) and neutron multiplier within each IU are cooled by the PCLS e the IU is in operation. The PCLS is a closed loop chilled water system that rejects heat to RPCS, an intermediate chilled water loop, which rejects heat to the process chilled water tem (PCHS). The PCHS is a closed chilled loop that rejects heat to the atmosphere by use of cooled chillers. Figure 5a2.1-1 depicts the heat flow path from generation to the environment.

neutron driver cooling is addressed in Section 4a2.3 and the recirculating heating, tilation, and air conditioning (HVAC) fan-coil unit that is part of the radiological ventilation e 1 recirculating cooling subsystem (RVZ1r) is discussed in Section 9a2.1.

primary and secondary IF cooling systems maintain the capability to provide sufficient heat oval to support continuous operation at full licensed power as discussed in the subsequent tions.

NE Medical Technologies 5a2.1-1 Rev. 0

NE Medical Technologies 5a2.1-2 Rev. 0

.2.1 DESIGN BASES AND FUNCTIONAL REQUIREMENTS primary closed loop cooling system (PCLS) provides forced convection water cooling to the et solution vessel (TSV) and neutron multiplier during irradiation of the target solution and ediately prior to transferring target solution from the TSV to the TSV dump tank. The PCLS provides indirect cooling of the light water pool via natural convection heat transfer to the LS components submerged in the pool, as described in Subsection 4a2.7.3. The PCLS cts heat to the radioisotope process facility cooling system (RPCS). A total of eight pendent instances of PCLS are installed in the SHINE facility, one for each irradiation unit

. There are no common pressure retaining components between the instances of PCLS. The or PCLS equipment is located in the primary cooling room and the IU cell.

h instance of PCLS includes two pumps, a heat exchanger, and a cooling water clean-up stream located in the primary cooling rooms adjacent to the east side of each IU cell. In the ell, the PCLS is connected to the subcritical assembly system (SCAS) and includes an air arator, an expansion tank, and nitrogen-16 (N-16) delay tanks. Figure 5a2.2-1 provides a LS flow diagram.

process functions of the PCLS cooling system are to:

  • remove heat from each TSV and neutron multiplier during full-power IU operation;
  • cool the light water pool by natural convection heat transfer to PCLS components inside the light water pool;
  • maintain water quality to reduce corrosion and scaling;
  • limit concentrations of particulate and dissolved contaminants that could be made radioactive by neutron irradiation;
  • reduce N-16 radiation exposure within the primary cooling room in support of as low as reasonably achievable (ALARA) goals; and
  • remove entrained gases from the cooling water.

LS removes heat from the TSV and neutron multiplier during startup and irradiation by ulating water in an upward direction [

]PROP/ECI along the exterior surfaces of the TSV and neutron multiplier walls. The subcritical embly support structure (SASS) provides the shell side pressure boundary to direct the ling water flow past the TSV and neutron multiplier. The PCLS is attached to the SASS upper lower plenums.

LS is designed to remove a minimum of 580,000 British thermal units per hour (Btu/hr) 0 kilowatts [kW]) of heat from each IU during full-power operation and during shutdown ditions when target solution is in the TSV.

LS is designed to maintain the pressure of the cooling water in the SASS higher than the rnal pressure of the TSV. The TSV is designed and fabricated to prevent target solution from ing into the PCLS. See Section 4a2.4 for additional information related to the TSV.

PCLS cleanup side stream maintains system cooling water quality. The PCLS is designed to rate without corrosion inhibiting chemicals in the process fluid. The cleanup side stream can NE Medical Technologies 5a2.2-1 Rev. 0

PCLS piping confines the cooling water within the IU cell and within the primary cooling room ted adjacent to the IU cell. Pressure retaining components are constructed of materials that ctively resist corrosion to limit activation products that could cause increased radiation osure of personnel and surrounding equipment. Major components are constructed of tenitic stainless steel.

PCLS air separator separates entrained gases from the cooling water and directs the gases he radiological ventilation zone 1 exhaust (RVZ1e) subsystem via the PCLS expansion tank.

6 is generated in the cooling water by the neutron activation of oxygen. Section 5a2.7 vides a discussion of the treatment of N-16 in the cooling water.

rpressure protection for PCLS is provided by system design. The shutoff head of the PCLS ps is below the PCLS design pressure. The PCLS is also directly vented to RVZ1e through PCLS expansion tank.

Table 5a2.2-1 for the PCLS operating parameters. See Table 5a2.2-2 for a list of the PCLS ponents.

.2.2 PCLS ANALYSES ailed analysis of the PCLS target solution cooling performance is found in Section 4a2.7.

t transfer and temperature profiles for the neutron multiplier are found in Subsection 4a2.2.6.

tive cooling to the TSV and neutron multiplier is unavailable, irradiation of the target solution be suspended. Target solution in the TSV will be transferred from the TSV to the TSV dump

, which is passively cooled by the light water pool. See Subsection 4a2.4.2.2 for the heat oval capacity of the light water pool. Loss of cooling design basis accidents are discussed in section 13a2.1.3.

PCLS pumps operate in parallel to provide the design flowrate to the PCLS heat exchanger.

uld one pump fail, the second pump, operating at a minimum of [

]PROP/ECI, provides adequate cooling to allow continuation of full-power irradiation while ntaining the bulk target solution temperature less than 176°F (80°C) within the TSV.

light water pool and TSV are located within the primary confinement, which also provides finement of the components of the PCLS located within the IU cell, as discussed in tion 6a2.2. The PCLS piping penetrations through primary confinement are located above minimum acceptable water level in the pool.

elding to protect workers and reduce dose rates to equipment is provided by the irradiation biological shield (ICBS), described in detail in Section 4a2.5.

cts resulting from a primary cooling water breach are discussed in Subsection 4a2.7.3.7.

s of primary cooling water does not result in loss of integrity of the primary system boundary B). Low cooling water flow causes an IU Cell Safety Actuation, which results in the TSV dump es opening and the target solution draining to the TSV dump tank. The thermal mass of the NE Medical Technologies 5a2.2-2 Rev. 0

atural convection heat transfer. See Subsection 4a2.7.3.8 for further discussion on the sition from forced to natural convection.

ding of the SCAS cooling channels caused by loss of primary cooling water causes reactivity rtions as discussed in Subsection 13a2.1.2. To prevent the drainage of primary cooling water the SCAS, the SCAS is located below grade in the light water pool. Portions of the PCLS ted outside of the light water pool are above grade to prevent gravity drainage of the SCAS ling channels.

PCLS pumps draw cooling water from a line connected to the PCLS expansion tank.

ause the expansion tank is vented, a leak of the PCLS pressure boundary would result in the LS expansion tank level reducing until the PCLS return line breaks vacuum. Once the PCLS rn line breaks vacuum, the PCLS pumps cannot draw more water out of the SCAS. This ngement ensures that the PCLS pumps cannot draw the water out of the SCAS cooling nnels.

use of centrifugal pumps and an air separator prevents the PCLS from effectively voiding the ling channels by pumping air into the SCAS.

functions or leaks in the PCLS do not cause uncontrolled release of primary cooling water ide the radiologically controlled area (RCA). The facility structure (FSTR) provides barriers at s from the RCA to prevent the release of potentially contaminated water to the uncontrolled ironment.

PCLS piping penetrating confinement boundaries are provided with isolation capabilities.

ng systems that pass between confinement boundaries are equipped with either:

  • a locked closed manual isolation valve, or
  • an automatic isolation valve that takes the position that provides greater safety upon loss of actuating power.

nual isolation valves are maintained locked-shut for any conditions requiring confinement ndary integrity. The automatic isolation valves are closed as part of an IU Cell Safety uation if the TSV reactivity protection system (TRPS) detects a malfunction of PCLS, akage of primary cooling water into the PSB, or outleakage of target solution into the primary ling water.

.2.3 INSTRUMENTATION AND CONTROL ssure, flow, temperature, conductivity, and level instrumentation monitor the operating ameters of the PCLS.

perature instrumentation is provided to ensure the cooling water supply temperature ains within allowable limits despite variations in TSV power. Output from the temperature rumentation is used for controlling the flow of RPCS water through the PCLS heat exchanger egulate the cooling water supply temperature at the SCAS cooling water inlet.

NE Medical Technologies 5a2.2-3 Rev. 0

rate with either one or both pumps operating.

e PCLS temperature or flowrate is outside allowable limits, the TRPS initiates an IU Cell ety Actuation, resulting in a transfer of the target solution to the TSV dump tank where it is led by natural convection to the light water pool.

ansion tank level instrumentation provides indication of loss of cooling water, such as by poration or radiolysis. Addition of makeup cooling water is a manual operation. Expansion level instrumentation can also perform a leak detection function as described in section 5a2.2.6.

ductivity instrumentation is provided to measure the conductivity of the PCLS water and nitor the performance of the PCLS cleanup side stream. Conductivity instrumentation can also orm a leak detection function as described in Subsection 5a2.2.6.

PCLS pressure, flow, temperature, and expansion tank level indications are available locally in the control room. Sampling and analysis of cooling water from the PCLS is performed lly. System operational controls are in the control room.

.2.4 RADIATION MONITORS AND SAMPLING RVZ1e line ventilating the PCLS expansion tank headspace is equipped with radiation nitors. The RVZ1e radiation monitors are intended to detect leakage of target solution or on product gases from the PSB or neutron multipliers. If radiation exceeding a predetermined oint is detected, the TRPS initiates an IU Cell Safety Actuation and the RVZ1e line is ated.

mpling and analysis of the water from the PCLS is performed to ensure that the water quality uirements are being maintained and contaminants are not present in the cooling water.

ntaining water quality ensures functional and safe operation by reducing corrosion damage scaling. See Table 5a2.2-1 for water quality requirements. Sampling of cooling water for ological contaminants is performed to detect possible leakage of target solution into the PSB.

.2.5 PCLS INTERFACES system interfaces of the PCLS are listed in Table 5a2.2-3.

PCLS cooling water is pumped through the PCLS heat exchanger, where the heat is sferred to the RPCS and subsequently transferred to the process chilled water system HS), where it is dissipated to the environment.

PCLS cooling water leaves the SCAS and enters the PCLS air separator, which allows ained radiolytic gas to separate from the cooling water. Besides hydrogen and oxygen, the dspace contains air, water vapor, and small amounts of N-16 and argon-41 (Ar-41). An rface between the RVZ1e and the expansion tank allows radiolytic gases to be purged to Z1e, preventing the buildup of hydrogen gas. Ambient air from within the primary confinement ndary is drawn through a flame arrestor and filter for sweeping of the expansion tank dspace.

NE Medical Technologies 5a2.2-4 Rev. 0

rface with the FDWS. This prevents possibly contaminated PCLS cooling water from coming ontact with the makeup water. The backflow prevention components help ensure the ALARA elines in Chapter 11 are met.

.2.6 LEAK DETECTION k detection is provided by the PCLS expansion tank level instrumentation, TSV dump tank l instrumentation, and conductivity instrumentation. Leak detection is also provided by ation monitoring and sampling, as discussed in Subsection 5a2.2.4.

expansion tank includes level instruments that allows operators to trend levels within the LS, which can indicate slow leaks of cooling water. Additionally, level indication in the TSV p tank provides indication of inleakage of cooling water into the PSB. If inleakage into the B is detected, the TRPS initiates an IU Cell Safety Actuation.

ductivity instrumentation can detect increases in conductivity of the PCLS cooling water ulting from inleakage of target solution.

.2.7 HYDROGEN LIMITS iolysis of the primary cooling water and the light water pool water results in the generation of rogen and oxygen gases. These gases must be vented to prevent the buildup of hydrogen.

RVZ1e draws air from the primary confinement and through the PCLS expansion tank dspace to dilute hydrogen within the primary confinement and expansion tank while the LS system is required to be in operation.

ing full-power irradiation, up to approximately 0.15 standard cubic feet per hour (scfh) standard cubic centimeters per minute [sccm]) of hydrogen gas is calculated to be generated e primary cooling water and up to approximately 0.38 scfh (180 sccm) of hydrogen is ulated to be generated in the light water pool.

Z1e provides a nominal flowrate of approximately 1 standard cubic feet per minute (scfm) standard liter per minute [slpm]) to the expansion tank headspace while the PCLS system is uired to be in operation. The relatively low nominal flowrate maintains hydrogen centrations within the primary confinement and expansion tank below 1 percent by volume e minimizing release of Ar-41 to the facility stack. Rates of Ar-41 production and release are cribed in Section 11.1.

.2.8 TECHNICAL SPECIFICATIONS tain material in this section provides information that is used in the technical specifications.

includes limiting conditions for operation, setpoints, design features, and means for omplishing surveillances. In addition, significant material is also applicable to, and may be d for the bases that are described in the technical specifications.

NE Medical Technologies 5a2.2-5 Rev. 0

Table 5a2.2 PCLS Operating Parameters PCLS Parameter Nominal Values oling Medium Water oling Medium Makeup Facility demineralized water system (FDWS) urce at Exchanger Duty 580,000 Btu/hr (170 kW) per irradiation unit (IU) cell oling Medium Supply 59°F to 77°F (15°C to 25°C) mperature oling Medium Flow Rate Minimum flow rate: [ ]PROP/ECI Nominal flow rate: [ ]PROP/ECI oling Medium Quality Conductivity: < 5 micromho per centimeter (µmho/cm) pH: 5.5 to 7.5 stem Type Forced cooling water, closed loop stem Design Pressure 100 pounds per square inch (psi) stem Design Temperature 200°F (93°C) aterial of Construction and Major components are fabricated from austenitic stainless brication steel NE Medical Technologies 5a2.2-6 Rev. 0

Table 5a2.2 PCLS Components Component Functions Code/Standard LS heat exchanger Transfers heat from PCLS cooling ASME BPVC,Section VIII, loop to the RPCS Division 1 (ASME, 2010)

LS expansion tank Provides thermal expansion ASME BPVC Section VIII, protection and pump head, and Division 1 (ASME, 2010) facilitates cooling loop level monitoring ping components PCLS cooling loop piping ASME B31.3 (ASME, 2013) trogen-16 (N-16) delay Allows for the decay of N-16 that is ASME B31.3 (ASME, 2013) nks generated in the cooling water by neutron activation of oxygen and for the decay of the gaseous flow path from the PCLS air separator LS pumps Circulates PCLS cooling water Note(a) through system components LS instrumentation Provides indication of PCLS See Chapter 7 for safety-operating parameters related instrumentation See Note(a) for nonsafety-related instrumentation LS air separator Allows entrained radiolytic gas to ASME BPVC Section VIII, leave the cooling water and enter into Division 1 (ASME, 2010) the expansion tank where it is vented to prevent the buildup of hydrogen in the system LS flame arrestor with Prevents the ignition of hydrogen in Note(a) er the PCLS expansion tank if RVZ1e flow through the expansion tank is lost LS deionizer bed Removes dissolved ions from the Note(a)

PCLS cooling water ommercially available equipment designed to standards satisfying system operation.

NE Medical Technologies 5a2.2-7 Rev. 0

Table 5a2.2 PCLS System Interfaces System Interface Description dioisotope process The RPCS interfaces with each of the eight instances of PCLS oling water system inside the radiologically controlled area (RCA). Nonsafety-related PCS) manual isolation valves are located at the interface with PCLS.

cility demineralized The FDWS interfaces with each of the eight PCLS cooling loops ter system (FDWS) inside the RCA. The FDWS interfaces with the PCLS downstream of a FDWS vacuum breaker. Nonsafety-related manual isolation valves are located at the interface with PCLS.

bcritical assembly The SCAS interfaces with the PCLS in each of the eight light water stem (SCAS) pools located in the irradiation facility (IF).

rmal electrical power The NPSS provides power to PCLS process skid, including pumps pply system (NPSS) and instrumentation, located inside the IF.

interruptible electrical The UPSS provides the PCLS safety-related instrumentation with wer supply system electrical power during normal conditions and during and following PSS) design basis events.

V reactivity protection The PCLS provides instrumentation for the TRPS to monitor stem (TRPS) variables important to the safe operation of the PCLS. The TRPS provides controls to the PCLS components to perform safety actuations when monitored variables exceed predetermined limits.

cility compressed air The FCAS provides compressed gas to the PCLS loop pneumatic stem (FCAS) control mechanisms located inside the IF.

ocess integrated The PICS monitors and controls the PCLS process parameters, ntrol system (PICS) utilizing the instrumentation and controlled components within the IF.

diological ventilation The RVZ1 provides an exhaust path from the headspace of each of ne 1 (RVZ1) the eight PCLS expansion tanks. The PCLS removes radiolytic gas from the cooling water and vents it to prevent combustible gas mixtures from forming.

diological ventilation The RVZ2 provides an indirect source of makeup air into the PCLS ne 2 (RVZ2) expansion tanks via the supply air provided to the IF through the primary confinement.

NE Medical Technologies 5a2.2-8 Rev. 0

NE Medical Technologies 5a2.2-9 Rev. 0

.3.1 DESIGN BASES AND FUNCTIONAL REQUIREMENTS radioisotope process facility cooling system (RPCS) removes heat generated from within the ological control area (RCA) and rejects the heat to the process chilled water system (PCHS).

RPCS is an intermediate closed-loop forced liquid cooling system that recirculates cooling er. The RPCS removes heat from the primary closed loop cooling system (PCLS), the tron driver assembly system (NDAS) cooling cabinets, the target solution vessel off-gas tem (TOGS), the recirculating heating, ventilation, and air conditioning (HVAC) fan-coil units are part of the radiological ventilation zone 1 recirculating cooling system (RVZ1r), the rculating HVAC fan-coil units that are part of the radiological ventilation zone 2 recirculating ling system (RVZ2r), the target solution preparation system (TSPS), the process vessel vent tem (PVVS), and the molybdenum extraction and purification system (MEPS). The total and placed on the RPCS by other systems is approximately 11.6 million British thermal units hour (MMBtu/hr) (3400 kilowatts [kW]). The RPCS consists of a heat exchanger, pumps, tem expansion tank, valves, instrumentation, and heat exchanger interfaces identified above.

RPCS major equipment is located in the RPCS room, within the RCA.

process functions of the RPCS are to:

  • maintain higher pressure than the cooling systems served at the respective interfaces;
  • remove process heat from systems served;
  • maintain cooling water quality to reduce corrosion and scaling; and
  • reject heat to the PCHS.

RPCS is a nonsafety-related system and is not credited with preventing or mitigating any ign basis events. See Figure 5a2.3-1 for the process flow diagram of the RPCS. See le 5a2.3-1 for the RPCS design and operating parameters. See Table 5a2.3-2 for the RPCS ponents.

.3.2 RPCS ANALYSES cooling function of the RPCS is not credited in the safety analysis for any system served by RPCS. If active cooling to the TSV and neutron multiplier is unavailable due to a loss of the CS, irradiation of the target solution will be suspended. Any target solution in the TSV will be sferred from the TSV to the TVS dump tank which is passively cooled by the light water pool.

tion 4a2.4 provides a discussion of the heat removal capacity of the light water pool. Loss of ling design basis accidents are discussed in Subsection 13a2.1.3.

essure cascade is maintained at each system heat exchanger that receives service such that RPCS cooling water is maintained at a higher pressure than those systems with the potential ontaminate the RPCS. Additionally, the PCHS is maintained at a higher pressure than the CS at the RPCS heat exchanger so that any leakage between the RPCS and the PCHS will d to leak into the RPCS.

keup water to the RPCS is from the facility demineralized water system (FDWS) as described ection 5a2.6. The RPCS piping includes backflow prevention components at the interface the FDWS. This prevents potentially contaminated RPCS cooling water from contacting the NE Medical Technologies 5a2.3-1 Rev. 0

.3.3 INSTRUMENTATION AND CONTROL process integrated control system (PICS) monitors the RPCS pressure, flow, temperature, conductivity to ensure operation within design parameters. Instrumentation is located in the CS loop to obtain accurate system operating information. Setpoints ensure that operators are ted when operating conditions are out of specification. Pressure, flow, and temperature are nitored within the RPCS to ensure that the system is operating within design conditions. Flow trol is provided on the downstream side of each interfacing systems heat exchanger.

onductivity analyzer is located near the RPCS heat exchanger and pump to monitor the ductivity of the RPCS cooling water. If the conductivity measurement is out of system rable parameters, operators are alerted such that the appropriate corrective actions can be

n. This protection limits corrosion and scaling damage in the RPCS system. Pressure, flow, temperature instrumentation on the supply and return lines of the RPCS can indicate a function in the system with an increase in pressure drop and/or low system flow. See le 5a2.3-1 for the RPCS operating parameters.

heat removal provided by RPCS to the PCLS is controlled by adjusting the RPCS flow rate ach heat exchanger. The RPCS flow rate is controlled on the return side of the process tem heat exchanger by means of a modulating flow control valve. This arrangement ensures the pressure differential between the RPCS and the PCLS is maintained, regardless of the ition of the temperature control valves.

.3.4 RADIATION MONITORS AND SAMPLING design of the cooling system ensures that release of radioactivity through the secondary ling system to the unrestricted environment will not lead to potential exposures to the public in ess of the requirements of 10 CFR 20 and the ALARA program guidelines. The RPCS is ntained at a higher pressure than the systems served. Furthermore, the RPCS is a closed system located inside the RCA. The facility structure (FSTR) provides barriers at exits from RCA to prevent the release of potentially contaminated cooling water to the uncontrolled ironment.

mpling and analysis of cooling water from the RPCS is performed to ensure radiological taminants are below acceptable limits. If unacceptable levels of contamination are found, the tem will be shut down and the contaminated cooling water will be purified using ion exchange

s. Operators then inspect the malfunctioning equipment and remedy the issue accordingly.

mpling and analysis of the cooling water from the RPCS is also performed to ensure that the er quality requirements are being maintained. Maintaining cooling water quality minimizes the ential for damage due to corrosion and scaling. Table 5a2.3-1 describes the RPCS cooling er quality requirements.

NE Medical Technologies 5a2.3-2 Rev. 0

RPCS components are listed in Table 5a2.3-2, including design codes and standards. The CS interfaces with the PCHS at the RPCS heat exchanger located within the RCA boundary.

system interfaces of the RPCS are listed in Table 5a2.3-3.

.3.6 TECHNICAL SPECIFICATIONS re are no technical specification parameters identified for the RPCS.

NE Medical Technologies 5a2.3-3 Rev. 0

Table 5a2.3 RPCS Operating Parameters Parameter Nominal Value oling Medium Water oling Medium Makeup FDWS urce pply Conditions Temperature: 40°F to 44°F (4.5°C to 6.5°C) turn Conditions Temperature: 60°F to 64°F (15.5°C to 17.5°C) sign Pressure 100 pounds per square inch (psi) sign Temperature 200°F (93°C) at Exchanger Duty 11.6 MMBtu/hr (3400 kW) oling Medium Flow Rate Volumetric flow rate: < 3000 gallons per minute (gpm) oling Medium Quality Conductivity: < 2000 µmho/cm pH: 6 to 8.

Based on recommendations for secondary cooling water parameters in IAEA No. NP-T-5.2 (IAEA, 2011).

stem Type RPCS is a forced liquid, closed loop cooling system circulating water to remove heat from PCLS and other process and non-process systems via heat exchangers.

aterial of Construction RPCS components are designed and fabricated in accordance d Fabrication with the codes and standards listed in Table 5a2.3-2.

NE Medical Technologies 5a2.3-4 Rev. 0

Table 5a2.3 RPCS Components Component Description Code/Standard CS heat exchanger Transfers heat from RPCS to PCHS. Note(a)

CS expansion tank Provides thermal expansion protection Note(a) for the RPCS piping and components.

CS buffer tank Provided to increase the system Note(a) volume to levels required to maintain system loop times.

ping components RPCS piping. ASME B31.9 (ASME, 2017)

CS pump Circulates RPCS water through system Note(a) components.

CS instrumentation Provide indication of RPCS operating Note(a) parameters (pressure, temperature, flow, and level).

ommercially available equipment designed to standards to satisfy system operation.

NE Medical Technologies 5a2.3-5 Rev. 0

Table 5a2.3 RPCS Interfaces (Sheet 1 of 2)

System Interface Description imary closed loop The RPCS interfaces with each of the eight PCLS cooling loops inside oling system (PCLS) the RCA. Nonsafety-related manual isolation valves are located at the interface with PCLS.

V off-gas system Interfaces at the TOGS cooling water supply and return connections OGS) inside the RCA to condense water vapor and remove heat from recombiner condensers and condenser-demisters. Nonsafety-related manual isolation valves are located at the interface with TOGS.

olybdenum extraction Interfaces at the evaporator supply and return connections inside the d purification system RCA to facilitate condensation of water vapor. Nonsafety-related EPS) manual isolation valves are located at the interface with MEPS.

ocess vessel vent Interfaces at the supply and return connections of the PVVS cooler and stem (PVVS) condensers within the RPF section of the RCA to reduce the PVVS process temperature and relative humidity. Nonsafety-related manual isolation valves are located at the interface with PVVS.

ocess chilled water Interfaces at the supply and return connections of the RPCS heat stem (PCHS) exchanger inside the RCA and transfers heat from the RPCS to the PCHS so it can be released to the environment exterior to the RCA boundary. Nonsafety-related manual isolation valves are located at the interface with PCHS.

rget solution Interfaces at the supply and return connections of the TSPS reflux eparation system condensers inside the RCA to mitigate liquid loss during dissolution.

SPS) Nonsafety-related manual isolation valves are located at the interface with TSPS.

diological ventilation Interfaces at the supply and return connections of the IU supplemental ne 1 recirculating cooling system fan coil, exterior to the primary confinement boundary, oling subsystem inside the RCA. Nonsafety-related manual isolation valves are located VZ1r) at the interface with RVZ1r.

diological ventilation Interfaces at the supply and return connections of the recirculating unit ne 2 recirculating fan coils inside the RCA. Nonsafety-related manual isolation valves are oling subsystem located at the interface with RVZ2r.

VZ2r) cility demineralized Interfaces upstream of the RPCS pumps inside the RCA to supply ter system (FDWS) makeup water to the RPCS.

utron driver assembly Interfaces with each of the nine NDAS cooling cabinets within the RCA stem (NDAS) to remove heat from the independent NDAS cooling loops.

NE Medical Technologies 5a2.3-6 Rev. 0

System Interface Description ocess integrated PICS monitors and controls RPCS actuators and instrumentation on ntrol system (PICS) valves, piping, and components.

rmal electrical power The NPSS provides power to RPCS equipment and instrumentation.

pply system (NPSS)

NE Medical Technologies 5a2.3-7 Rev. 0

NE Medical Technologies 5a2.3-8 Rev. 0

.4.1 DESIGN BASIS AND FUNCTIONAL REQUIREMENTS process chilled water system (PCHS) removes heat from the radioisotope process facility ling system (RPCS) from within the radiologically controlled area (RCA) and rejects the heat he environment. The PCHS interfaces with the RPCS heat exchanger and is comprised of ulation pumps, flow control valves, an expansion tank, a buffer tank, a glycol makeup unit, rumentation, and packaged air-cooled chillers. The PCHS is a forced liquid, convective flow, ed loop cooling system that uses air-cooled chillers to facilitate heat rejection to the ironment. The PCHS is designed to remove the total heat transfer demand placed on RPCS ther systems.

PCHS is a nonsafety-related system and is not credited with preventing or mitigating any ign basis events. Table 5a2.4-1 provides the PCHS operating parameters. Table 5a2.4-2 vides a description of PCHS components. Figure 5a2.4-1 provides a process flow diagram of PCHS.

process functions of the PCHS are to:

  • remove heat from the RPCS heat exchangers;
  • reject heat to the environment;
  • maintain water quality to reduce corrosion and scaling; and
  • prevent freezing of exterior piping and components.

PCHS is designed for local outdoor operation. The system is operated with a propylene ol/water mixture through the RPCS heat exchanger. Process generated heat is transferred the facility process systems into the RPCS inside the RCA. The RPCS transfers this cess heat to the PCHS through the RPCS heat exchanger, located inside the RCA. The HS then routes the process heat outside the RCA, and ultimately out of the facility to air-led chillers. The PCHS is provided makeup water from the facility demineralized water tem (FDWS), which is described in Section 5a2.6, and glycol through a manual fill point for mal operation. Table 5a2.4-1 describes the PCHS water quality requirements.

.4.2 PROCESS CHILLED WATER SYSTEM ANALYSES PCHS is designed to remove the total heat transfer demand placed on the RPCS by other tems of approximately 11.6 MMBtu/hr (3400 kW). The PCHS is maintained at a higher ssure than the RPCS to ensure that leakage at the system interface heat exchanger flows potentially less contaminated cooling water to potentially more contaminated cooling water.

.4.3 INSTRUMENTATION AND CONTROL PCHS provides output signals to the process integrated control system (PICS) for the nitoring of cooling water temperatures, pressures, tank level, and flow rates.

ssure, flow, tank level, and temperature measurement instrumentation are strategically ted in the PCHS cooling loop to obtain system operating information. Setpoints ensure that rators are alerted when an operating condition is out of specification. Buffer tank level oints are monitored to indicate high or low system volume conditions.

NE Medical Technologies 5a2.4-1 Rev. 0

RPCS, transfers heat from the PCLS to the PCHS. The PCHS dissipates the heat from the CS to the environment. The RPCS is maintained at a lower pressure than PCHS at the RPCS t exchanger as such any leakage between RPCS and PCHS would tend to leak into RPCS.

PCLS, RPCS, and PCHS are closed loop systems. Samples of cooling water are analyzed contamination and conductivity. The contaminated volume of cooling water is recycled in er an on-site recycling unit or a mobile service unit. Water quality is maintained to reduce osion and scaling in the system. System cooling water level is monitored to provide indication ystem in-leakage or out-leakage. These design features ensure that radioactivity is not ased through the PCHS to the unrestricted environment and will not lead to potential osures of the public in excess of the requirements of 10 CFR 20 and the as low as reasonably ievable (ALARA) program guidelines.

system interfaces of the PCHS are listed in Table 5a2.4-3.

.4.5 TECHNICAL SPECIFICATIONS re are no technical specification parameters identified for the PCHS.

NE Medical Technologies 5a2.4-2 Rev. 0

Table 5a2.4 PCHS Operating Parameters PCHS Parameter Nominal Values oling medium Propylene glycol/water oling medium make-up source FDWS with manual addition of propylene glycol pply conditions Temperature: 30°F to 40°F (-1°C to 4.5°C) turn conditions Temperature: 50°F to 60°F (10°C to 15.5°C) sign pressure 160 psi sign temperature 200°F (93.3°C) vironment Design dry bulb temperature (DBT) range: -10°F to 91.5°F (-23°C to 33°C) iller heat duty 11.6 MMBtu/hr (3400 kW) oling medium flow rate Volumetric flow rate: < 2200 gallons per minute (gpm) stem type PCHS is a forced liquid, closed loop cooling system circulating propylene glycol/water. The PCHS removes heat from the RPCS heat exchangers and transfer it to air-cooled chillers located outside of the facility.

aterial of construction and PCHS components are designed and fabricated in brication accordance with the codes and standards listed in Table 5a2.4-2.

at dissipation This system dissipates heat to the environment through air-cooled chillers.

NE Medical Technologies 5a2.4-3 Rev. 0

Table 5a2.4 PCHS Components Component Description Code/Standard HS chiller Transfers heat from PCHS to the Note (a) environment.

HS expansion tank Provides thermal expansion Note (a) protection for the PCHS piping and components.

HS buffer tank Provided to increase the system Note (a) volume to levels required to maintain system loop times.

HS pump Circulates PCHS Coolant through Note (a) system components ping components PCHS piping. ASME B31.9 (ASME, 2017) strumentation Provide indication of PCHS Note (a) operating parameters (pressure, temperature, flow, and level).

ommercially available equipment designed to standards to satisfy system operation.

NE Medical Technologies 5a2.4-4 Rev. 0

Table 5a2.4 PCHS System Interfaces System Interface Description dioisotope process cooling Interfaces at the RPCS heat exchangers inside RCA.

stem (RPCS) The PCHS removes heat from the RCA through the RPCS heat exchangers and rejects the heat to the environment outside the RCA.

mospheric environment Interfaces at the PCHS chillers. Transfers heat from the PCHS through air chillers to the environment outside of the RCA boundary.

NE Medical Technologies 5a2.4-5 Rev. 0

NE Medical Technologies 5a2.4-6 Rev. 0

.5.1 DESIGN BASES AND PROCESS FUNCTIONS primary closed loop cooling system (PCLS) cleanup side stream maintains the required er quality limits of the PCLS.

following are the process functions of the PCLS cleanup side stream:

  • Maintain water quality to reduce corrosion and scaling; and
  • Limit concentrations of particulate and dissolved contaminants that could be made radioactive by neutron irradiation to achieve as low as reasonably achievable (ALARA) goals.

PCLS cooling water is treated to meet water quality limits discussed in Table 5a2.2-1. The nup components are located on a side stream through which the PCLS diverts a portion of cooling water flow. The components that perform the PCLS cooling water treatment are ted within the PCLS cleanup side stream flow path.

PCLS cleanup side stream includes conductivity instrumentation to monitor water quality, nizer beds to remove ionic species, and filters on the inlet and outlet of the deionizer beds to ove particulates from the cooling water.

ntaining the design water quality limits corrosion damage and scaling of the PCLS, the target tion vessel (TSV), and the neutron multiplier, which are components of the subcritical embly system (SCAS). The PCLS cleanup side stream removes contaminates that could ome activated and radioactive materials from the PCLS cooling water in order to meet RA occupational exposure goals described in Section 11.1. The PCLS cleanup side stream its components are designed and selected so that malfunctions are unlikely. Malfunctions leaks in the PCLS and the PCLS cleanup side streams are addressed in Subsection 5a2.2.2.

Table 5a2.2-2 for the list of PCLS components and their functions.

PCLS cleanup side stream components are designed and fabricated in accordance with the es and standards listed in Table 5a2.2-2.

.5.2 PCLS CLEANUP SIDE STREAM CONTROL AND INSTRUMENTATION PCLS cleanup side stream instrumentation is located in the primary cooling room.

ductivity instrumentation located at the outlet of the PCLS cleanup side stream measures the ductivity within the PCLS. The pH of the PCLS cooling water is monitored through sampling he system and analysis of the cooling water is performed by the quality control and analytical ing laboratories (LABS). Pressure, flow, temperature, conductivity, and level instrumentation nitor the operating parameters of the PCLS as discussed in Subsection 5a2.2.3.

.5.3 PCLS CLEANUP SIDE STREAM COMPONENTS AND LOCATIONS PCLS cleanup side stream components are located in the primary cooling room, directly cent to the IU cells.

NE Medical Technologies 5a2.5-1 Rev. 0

nup side stream. After the PCLS cooling water is diverted to the PCLS cleanup side stream, st flows through a pre-filter, through a deionizer bed and finally through a post-filter. Following process, the PCLS cooling water side stream is reintroduced into the PCLS main flow path r to entering the SCAS.

.5.4 MAINTENANCE AND TESTING PCLS cleanup side stream pre-filters, post-filters, and deionizer units are replaced at regular rvals in accordance with maintenance procedures. Spent filters and deionizer units are osed of as radioactive waste via the solid radioactive waste processing (SRWP) system.

her discussion of SRWP can be found in Section 9b.7. Subsection 11.2.2 addresses pliance with 10 CFR 20 and presents ALARA guidelines relative to radioactive waste control.

le 11.2-1 provides a list of solid radioactive wastes including an estimate of annual quantities erated and disposal destinations.

mpling and testing of the PCLS cooling water is performed as described in section 5a2.2.5.

ating the PCLS cleanup side stream from the associated PCLS cooling loop for maintenance poses does not disrupt irradiation unit (IU) operation or prevent safe IU shutdown.

.5.5 PREDICTING, MONITORING AND SHIELDING RADIOACTIVITY PCLS cleanup side stream components are located entirely within the primary cooling room ociated with their respective IU cell. Each primary cooling room is located within the diation cell biological shield (ICBS). The ICBS provides a barrier to protect SHINE facility sonnel, members of the public, and various components and equipment of the SHINE facility educing radiation exposure. Refer to Section 4a2.5 for information pertaining to ICBS lding requirements. Radiation monitoring of the ICBS general area is provided as discussed ection 7.7.

LS does not discharge radioactive liquid effluent from the facility; therefore, there are no liquid ent monitors. Monitoring of closed loop process cooling water systems to detect cooling er leakage between primary and secondary circuits due to failures in heat exchangers and er system boundaries is provided.

discussed in Subsection 5a2.2.2, PCLS piping penetrating confinement boundaries are vided with isolation capabilities. Automatic isolation valves on the PCLS supply and return s exiting the IU cell are closed as part of an IU Cell Safety Actuation if the TSV reactivity ection system (TRPS) detects an outleakage of target solution into the primary cooling water.

hermore, the PCLS equipment is located inside the primary cooling room and IU cell, which shielded by ICBS. These design features limit exposure of personnel to radioactivity.

PCLS is a closed loop system and is operated at a higher pressure than the TSV to reduce potential for leakage of the target solution into the PCLS in the event of a breach. In the event ressurization of the primary system boundary, potential leakage from the TSV would be tained within the PCLS. Table 11.1-9 identifies the various locations, types, and expected NE Medical Technologies 5a2.5-2 Rev. 0

.5.6 TECHNICAL SPECIFICATIONS re are no technical specification parameters identified for the PCLS cleanup loop.

NE Medical Technologies 5a2.5-3 Rev. 0

facility demineralized water system (FDWS) provides makeup water to the primary closed cooling system (PCLS), radioisotope process facility cooling system (RPCS), facility chilled er system (FCHS), molybdenum extraction and purification system (MEPS) hot water loop system, light water pool, and process chilled water system (PCHS). The FDWS provides a er supply to the radiological ventilation zone 2 (RVZ2) system and the facility ventilation zone VZ4) system for humidity control. The quality control and analytical testing laboratories BS) and the facility chemical reagent system (FCRS) are supplied demineralized water from FDWS. Operational cooling water loss in the PCLS and light water pool occurs gradually from olysis and evaporation. Water loss in the PCLS, RPCS, FCHS, MEPS hot water subsystem, PCHS may also occur from off-normal events such as leaks or for maintenance. Makeup the FDWS to the systems served is supplied through piping that contains backflow vention. Transfers of makeup water from the FDWS to the cooling and heating systems are ormed manually. Refer to Figure 5a2.6-1 for a flow diagram of the FDWS.

FDWS is supplied water from the facility potable water system (FPWS). The FDWS consists reverse osmosis (RO) skid located outside of the radiologically controlled area (RCA). The skid is a packaged unit that contains pre-filters, piping, valves, pumps, and RO membranes upply RO water. The RO skid is located downstream of the backflow prevention device that as the system boundary between the FPWS and the FDWS. A portion of the demineralized er processed through the RO membrane is supplied to end users outside the RCA requiring treated water with the balance supplied to the RO storage tank located inside the RCA. A ond backflow prevention device is provided at the boundary where the FDWS enters the A.

FDWS includes two 100% capacity pumps. The two pumps are supplied water from the RO age tank that has been filtered by the RO membrane on the RO skid. The pumps circulate er from the RO storage tank to a ring header inside the RCA and back to the tank. Only one p is required to be operational for system service. Recirculated water is supplied directly to users requiring RO-processed water, and through deionizers to other end users requiring nized water. Table 5a2.6-1 identifies the RO-processed and deionized water end users.

FDWS components are listed in Table 5a2.6-2, including design codes and standards.

w from the RO skid is controlled by level instrumentation in the RO storage tank. Tank level is vided with high- and low-level alarms. Pressure is monitored at the outlet of the circulation p where high- and low-level alarms are provided. Sampling and trending of the system is ormed to detect malfunctions in the deionizer units and the RO skid. Sampling and trending ve to identify when replacement or repair is necessary.

FDWS is not safety-related. On loss of normal power, the pumps will not be operational, as FDWS is not relied on to provide water on loss of normal power.

NE Medical Technologies 5a2.6-1 Rev. 0

Table 5a2.6 FDWS End Users verse Osmosis Water End Users ility chilled water system (FCHS) ility chemical reagent system (FCRS) servicing the chemical storage room ality control and analytical testing laboratories (LABS) in the Wet and Instrument Laboratories cess chilled water system (PCHS) dioisotope process facility cooling system (RPCS) diological ventilation zone 2 (RVZ2) ility ventilation zone 4 (FVZ4) onized Water End Users molybdenum extraction and purification system (MEPS) hot water loop subsystem ility chemical reagent system (FCRS) servicing the chemical storage room ality control and analytical testing laboratories (LABS) in the Wet and Instrument Laboratories mary closed loop cooling system (PCLS) ht water pool system (LWPS)

NE Medical Technologies 5a2.6-2 Rev. 0

Table 5a2.6 FDWS Components Component Description Code/Standard cility demineralized The RO skid is a packaged unit that Note(a) ter system (FDWS) contains pre-filters, piping, valves, verse osmosis (RO) pumps, and RO membranes.

id WS deionizer units Provided to house deionization resins Note(a) for the removal of contaminants and the reduction of water conductivity.

WS RO storage tank Provided to maintain adequate RO Note(a) system supply volumes.

WS pumps Circulates FDWS RO water through Note(a) system components.

ping components FDWS piping. ASME B31.9 (ASME, 2011) strumentation Provide indication of FDWS operating Note(a) parameters (pressure, temperature, conductivity, flow, and level).

ommercially available equipment designed to standards satisfying system operation.

NE Medical Technologies 5a2.6-3 Rev. 0

Chapter 5 - Cooling Systems Facility Demineralized Water System Figure 5a2.6 Facility Demineralized Water System Flow Diagram SHINE Medical Technologies 5a2.6-4 Rev. 0

ogen-16 (N-16) is generated in the PCLS and light water pool by the neutron activation of gen. The N-16 control is provided by the primary closed loop cooling system (PCLS) delay ks. As shown in Figure 5a2.2-1, one liquid delay tank is located downstream of the air arator, in the PCLS cooling loop flow path, and the other is a gaseous delay tank located nstream of the PCLS expansion tank, inside the primary confinement boundary.

N-16 delay tanks provide additional holdup time to allow for sufficient decay of N-16 prior to ing the shielding to meet with as low as reasonably achievable (ALARA) goals and the ation protection program. In addition, to allowing a portion of the N-16 to decay, a reduction in lding wall thickness is realized as well as a reduction in the PCLS equipment radiation rance requirements.

PCLS uses an air separator to remove entrained gases from the cooling water flow path.

PCLS air separators are vented to the headspace of the corresponding IU cell expansion inside the primary confinement boundary. The headspace of the PCLS expansion tank epts separated gases, including N-16, and directs those gases to the gaseous delay tank, ugh the primary confinement boundary, and into the radiological ventilation zone 1 exhaust Z1e). Redundant safety-related isolation valves are provided on the flow path between the eous N-16 delay tank and the RVZ1e interface with the PCLS.

section 11.1.1 provides a discussion of airborne and liquid radiation sources at the SHINE lity, including N-16.

NE Medical Technologies 5a2.7-1 Rev. 0

primary closed loop cooling system (PCLS) provides cooling to the target solution vessel V) and the neutron multiplier. SHINE facility auxiliary systems do not utilize the PCLS for ling duty.

NE Medical Technologies 5a2.8-1 Rev. 0

RI, 2015. Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages ng the Vapor Compression Cycle, AHRI Standard 550/590 (I-P), Air-Conditioning, Heating, Refrigeration Institute, 2015.

ME, 2010. Rules for Construction of Pressure Vessels, ASME Boiler and Pressure Vessel e, VIII, Division 1, American Society of Mechanical Engineers, 2010.

ME, 2013. Process Piping, ASME Code for Pressure Piping, B31, ASME B31.3-2012, erican Society of Mechanical Engineers, 2013.

ME, 2017. Building Services Piping, ASME Code for Pressure Piping, B31, ME B31.9-2017, American Society of Mechanical Engineers, 2017.

A, 2011. Good Practices for Water Quality Management in Research Reactors and Spent l Storage Facilities, IAEA Nuclear Energy Series No. NP-T-5.2, International Atomic Energy ncy, 2011.

NE Medical Technologies 5a2.9-1 Rev. 0

NE cooling systems are integrated throughout the facility as described in Section 5a2. The oisotope process facility cooling system is described in Section 5a2.3.

NE Medical Technologies 5b-1 Rev. 0