ML17250A837: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
(One intermediate revision by the same user not shown) | |||
Line 6: | Line 6: | ||
| number = ML17309A114 | | number = ML17309A114 | ||
| issue date = 12/23/1980 | | issue date = 12/23/1980 | ||
| title = | | title = LER 80-010/03L-0:on 801125,pinhole Leak Found in Weld on RHR Thermowell.Caused by Poor Quality Weld.Weld Repaired | ||
| author name = | | author name = Spector S | ||
| author affiliation = ROCHESTER GAS & ELECTRIC CORP. | | author affiliation = ROCHESTER GAS & ELECTRIC CORP. | ||
| addressee name = | | addressee name = | ||
Line 22: | Line 22: | ||
| issue date = 12/23/1980 | | issue date = 12/23/1980 | ||
| title = Forwards LER 80-010/03L-0 | | title = Forwards LER 80-010/03L-0 | ||
| author name = | | author name = Maier J | ||
| author affiliation = ROCHESTER GAS & ELECTRIC CORP. | | author affiliation = ROCHESTER GAS & ELECTRIC CORP. | ||
| addressee name = GRIER B H | | addressee name = GRIER B H |
Latest revision as of 03:13, 8 March 2020
Date released: 04/30/2018 | Download: ML17250A837 |
---|---|
ML17309A114 | |
Person / Time | |
---|---|
Site: | Ginna |
Issue date: | 12/23/1980 |
From: | Spector S ROCHESTER GAS & ELECTRIC CORP. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
References | |
Download: ML17309A114 (2) | |
ML17250A836 | |
Person / Time | |
---|---|
Site: | Ginna |
Issue date: | 12/23/1980 |
From: | Maier J ROCHESTER GAS & ELECTRIC CORP. |
To: | GRIER B H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
References | |
Download: ML17250A836 (2) | |