ML17250A837

From kanterella
Jump to navigation Jump to search
Forwards LER 80-010/03L-0
Date released: 04/30/2018 Download: ML17250A837


LER 80-010/03L-0:on 801125,pinhole Leak Found in Weld on RHR Thermowell.Caused by Poor Quality Weld.Weld Repaired
ML17309A114
Person / Time
Site: Ginna Constellation icon.png
Issue date: 12/23/1980
From: Spector S
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML17309A114 (2)
Forwards LER 80-010/03L-0
ML17250A836
Person / Time
Site: Ginna Constellation icon.png
Issue date: 12/23/1980
From: Maier J
ROCHESTER GAS & ELECTRIC CORP.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML17250A836 (2)