ML17326A400: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17326A400
| number = ML17326A400
| title = Forwards LERs 79-061/03L-0 & 79-062/03L-0
| title = Forwards LERs 79-061/03L-0 & 79-062/03L-0
| release date = 05/31/2018
| package contents = {{Adams package content
| package contents = {{Adams package content
| number = ML17326A402
| number = ML17326A402
| issue date = 12/11/1979
| issue date = 12/11/1979
| title = Forwards LERs 79-061/03L-0 & 79-062/03L-0
| title = LER 79-062/03L-0:on 791111,inoperable Steam Flow Channel 1 Taken Out of Trip Condition During Investigation of Channel Spec Reading.Caused by Incorrect Panel Indicator Labeling. Channel Placed in Trip Mode & Labeling Corrected
| author name = DELONG S D
| author name = Delong S
| author affiliation = INDIANA MICHIGAN POWER CO.
| author affiliation = INDIANA MICHIGAN POWER CO.
| addressee name =  
| addressee name =  
Line 20: Line 21:
| number = ML17326A401
| number = ML17326A401
| issue date = 12/11/1979
| issue date = 12/11/1979
| title = Forwards LERs 79-061/03L-0 & 79-062/03L-0
| title = LER 79-061/03L-0:on 791111,during Startup,Steam Generator 4 Steam Flow Channel 1 Indicated 21% Lower than Redundant Channel.Caused by Oil Leak from Bellows to Transmitter Body Causing Drift Out of Spec.Transmitter Replaced
| author name = DELONG S D
| author name = Delong S
| author affiliation = INDIANA MICHIGAN POWER CO.
| author affiliation = INDIANA MICHIGAN POWER CO.
| addressee name =  
| addressee name =  
Line 36: Line 37:
| issue date = 12/11/1979
| issue date = 12/11/1979
| title = Forwards LERs 79-061/03L-0 & 79-062/03L-0
| title = Forwards LERs 79-061/03L-0 & 79-062/03L-0
| author name = SHALLER D V
| author name = Shaller D
| author affiliation = INDIANA MICHIGAN POWER CO.
| author affiliation = INDIANA MICHIGAN POWER CO.
| addressee name = KEPPLER J G
| addressee name = KEPPLER J G

Latest revision as of 06:03, 7 March 2020

Forwards LERs 79-061/03L-0 & 79-062/03L-0
Date released: 05/31/2018 Download: ML17326A400


LER 79-062/03L-0:on 791111,inoperable Steam Flow Channel 1 Taken Out of Trip Condition During Investigation of Channel Spec Reading.Caused by Incorrect Panel Indicator Labeling. Channel Placed in Trip Mode & Labeling Corrected
ML17326A402
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 12/11/1979
From: Delong S
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A402 (3)
LER 79-061/03L-0:on 791111,during Startup,Steam Generator 4 Steam Flow Channel 1 Indicated 21% Lower than Redundant Channel.Caused by Oil Leak from Bellows to Transmitter Body Causing Drift Out of Spec.Transmitter Replaced
ML17326A401
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 12/11/1979
From: Delong S
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A401 (1)
Forwards LERs 79-061/03L-0 & 79-062/03L-0
ML17326A399
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 12/11/1979
From: Shaller D
INDIANA MICHIGAN POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A399 (2)