ML16341B092: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 14: | Line 14: | ||
| document type = Updated Final Safety Analysis Report (UFSAR) | | document type = Updated Final Safety Analysis Report (UFSAR) | ||
| page count = 1 | | page count = 1 | ||
}} | |||
=Text= | |||
{{#Wiki_filter:IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERRDD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTTUUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTTRevision:16.1Table:6.2-7 Page:1 of 1SINGLE PASSIVE FAILURE ANALYSIS - EMERGENCY CORE COOLING SYSTEMRECIRCULATION PHASEFlow PathIndication of Loss of Flow PathAlternate Flow PathCOLD LEGFrom containment recirculation sump to low headcold leg injection header via the residual heatremoval pumps and the residual heat exchangers.Reduced flow in the discharge line, fromone of the residual heat exchangers (oneflow monitor in each discharge line) and/or leakage sump level alarmVia the independent identical low head flow path utilizingthe pumps second residual heat exchangerHOT LEGFrom containment recirculation sump to hot leglow - head injection header via RHR pumps andRHR heat exchangers.Same as aboveSame as aboveCOLD LEGFrom containment recirculation sump to the highhead cold leg injection header via the west residual heat removal pump, west residual heat exchanger and the safety injection pumps.Reduced flow in the discharge lines fromthe safety injection pumps (one flow monitor in each discharge line) and/or leakage sump level alarm.From containment recirculation sump to the high head coldleg injection headers via east residual heat removal pump, east residual heat exchanger and the centrifugal charging pumps cross - tie to SI pump suction.HOT LEGFrom containment recirculation sump to the highhead hot leg injection headers via west residualremoval pump, west residual heat exchanger andthe safety injection pumps.Reduced flow in the discharge lines fromthe safety injection pumps (one flowmonitor in each discharge line) and/orleakage sump level alarm.From containment spray to the high head hot leg injectionpoints via East residual heat removal heat removal pump,East residual heat exchanger and the centrifugal chargingpumps cross tie to SI Pump suction | |||
}} | }} | ||
Revision as of 14:44, 1 May 2018
Text
IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERRDD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTTUUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTTRevision:16.1Table:6.2-7 Page:1 of 1SINGLE PASSIVE FAILURE ANALYSIS - EMERGENCY CORE COOLING SYSTEMRECIRCULATION PHASEFlow PathIndication of Loss of Flow PathAlternate Flow PathCOLD LEGFrom containment recirculation sump to low headcold leg injection header via the residual heatremoval pumps and the residual heat exchangers.Reduced flow in the discharge line, fromone of the residual heat exchangers (oneflow monitor in each discharge line) and/or leakage sump level alarmVia the independent identical low head flow path utilizingthe pumps second residual heat exchangerHOT LEGFrom containment recirculation sump to hot leglow - head injection header via RHR pumps andRHR heat exchangers.Same as aboveSame as aboveCOLD LEGFrom containment recirculation sump to the highhead cold leg injection header via the west residual heat removal pump, west residual heat exchanger and the safety injection pumps.Reduced flow in the discharge lines fromthe safety injection pumps (one flow monitor in each discharge line) and/or leakage sump level alarm.From containment recirculation sump to the high head coldleg injection headers via east residual heat removal pump, east residual heat exchanger and the centrifugal charging pumps cross - tie to SI pump suction.HOT LEGFrom containment recirculation sump to the highhead hot leg injection headers via west residualremoval pump, west residual heat exchanger andthe safety injection pumps.Reduced flow in the discharge lines fromthe safety injection pumps (one flowmonitor in each discharge line) and/orleakage sump level alarm.From containment spray to the high head hot leg injectionpoints via East residual heat removal heat removal pump,East residual heat exchanger and the centrifugal chargingpumps cross tie to SI Pump suction