{{#Wiki_filter:ATTACHMENT 3 WALKDOWN CHECKLISTS Status:       N U Seismic Walkdown Checklist (SWC)
{{#Wiki_filter:ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2SFC*P1B Equipment Class:     (5) Horizontal Pumps Equipment
N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SFC*P1B Equipment Class:
(5) Horizontal Pumps Equipment


== Description:==
== Description:==
SFC WATER CIRC PUMP 1B Project:   Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):       SC, 290.00 ft, ALL Manufacturer/Model:
SFC WATER CIRC PUMP 1B Project:
Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):
SC, 290.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
Anchorage
: 1. Is anchorage configuration verification required (i.e., is the item one of the 50%                     No of SWEL items requiring such verification)?
: 1.
: 2. Is the anchorage free of bent, broken, missing or loose hardware?                                 Yes
Is anchorage configuration verification required (i.e., is the item one of the 50%
: 3. Is the anchorage free of corrosion that is more than mild surface oxidation?                       Yes
of SWEL items requiring such verification)?
: 4. Is the anchorage free of visible cracks in the concrete near the anchors?                         Yes
No
: 5. Is the anchorage configuration consistent with plant documentation? (Note:               Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 2.
: 6. Based on the above anchorage evaluations, is the anchorage free of                                 Yes potentially adverse seismic conditions?
Is the anchorage free of bent, broken, missing or loose hardware?
Interaction Effects C-340
Yes
: 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
Yes
: 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
Yes
: 5.
Is the anchorage configuration consistent with plant documentation? (Note:
This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Not Applicable
: 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?
Yes Interaction Effects C-340


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2SFC*P1B Equipment Class:     (5) Horizontal Pumps Equipment
N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SFC*P1B Equipment Class:
(5) Horizontal Pumps Equipment


== Description:==
== Description:==
SFC WATER CIRC PUMP 1B
SFC WATER CIRC PUMP 1B
: 7. Are soft targets free from impact by nearby equipment or structures?                           Yes
: 7.
: 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and                   Yes masonry block walls not likely to collapse onto the equipment?
Are soft targets free from impact by nearby equipment or structures?
: 9. Do attached lines have adequate flexibility to avoid damage?                                   Yes
Yes
: 10. Based on the above seismic interaction evaluations, is equipment free of                       Yes potentially adverse seismic interaction effects?
: 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
: 9.
Do attached lines have adequate flexibility to avoid damage?
Yes
: 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
Other Adverse Conditions
: 11. Have you looked for and found no adverse seismic conditions that could                           Yes adversely affect the safety functions of the equipment?
: 11.
Comments Evaluated by:                                     George G Thomas                   Date: 08/23/12 Neda Stoeva                               08/23/12 Photos C-341
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by:
George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 Photos C-341


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E     N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:     2SFC*SOV54A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
Equipment ID No.:
2SFC*SOV54A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
SKIMMER SURGE TANK OUTLET Project:   Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):       SC, 331.00 ft, ALL Manufacturer/Model:
SKIMMER SURGE TANK OUTLET Project:
Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):
SC, 331.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
Anchorage
: 1. Is anchorage configuration verification required (i.e., is the item one of the 50%                     No of SWEL items requiring such verification)?
: 1.
: 2. Is the anchorage free of bent, broken, missing or loose hardware?                       Not Applicable
Is anchorage configuration verification required (i.e., is the item one of the 50%
: 3. Is the anchorage free of corrosion that is more than mild surface oxidation?             Not Applicable
of SWEL items requiring such verification)?
: 4. Is the anchorage free of visible cracks in the concrete near the anchors?               Not Applicable
No
: 5. Is the anchorage configuration consistent with plant documentation? (Note:               Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 2.
: 6. Based on the above anchorage evaluations, is the anchorage free of                                 Yes potentially adverse seismic conditions?
Is the anchorage free of bent, broken, missing or loose hardware?
Interaction Effects C-342
Not Applicable
: 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
: 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
: 5.
Is the anchorage configuration consistent with plant documentation? (Note:
This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Not Applicable Not Applicable Not Applicable
: 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?
Yes Interaction Effects C-342


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2SFC*SOV54A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SFC*SOV54A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
SKIMMER SURGE TANK OUTLET
SKIMMER SURGE TANK OUTLET
: 7. Are soft targets free from impact by nearby equipment or structures?                           Yes
: 7.
: 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and                 Yes masonry block walls not likely to collapse onto the equipment?
Are soft targets free from impact by nearby equipment or structures?
: 9. Do attached lines have adequate flexibility to avoid damage?                                   Yes
Yes
: 10. Based on the above seismic interaction evaluations, is equipment free of                       Yes potentially adverse seismic interaction effects?
: 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
: 9.
Do attached lines have adequate flexibility to avoid damage?
Yes
: 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
Other Adverse Conditions
: 11. Have you looked for and found no adverse seismic conditions that could                           Yes adversely affect the safety functions of the equipment?
: 11.
Comments Evaluated by:               -                    George G Thomas                   Date: 08/23/12 Neda Stoeva                               08/23/12 Photos C-343
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by:
George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 Photos C-343


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N   U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N
Equipment ID No.: 2SFC*SOV54A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SFC*SOV54A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
SKIMMER SURGE TANK OUTLET C-344
SKIMMER SURGE TANK OUTLET C-344


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2CES*RAK105 Equipment Class:     (18) Instruments on Racks Equipment
Y N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2CES*RAK105 Equipment Class:
(18) Instruments on Racks Equipment


== Description:==
== Description:==
RACK (SFC/CMS INSTRUMENTATION)
RACK (SFC/CMS INSTRUMENTATION)
Project:   Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):       SC, 261.00 ft, ALL Manufacturer/Model:
Project:
Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):
SC, 261.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
Anchorage
: 1. Is anchorage configuration verification required (i.e., is the item one of the 50%                 Yes of SWEL items requiring such verification)?
: 1.
Is anchorage configuration verification required (i.e., is the item one of the 50%
of SWEL items requiring such verification)?
DRW 12177-MS-1930
DRW 12177-MS-1930
: 2. Is the anchorage free of bent, broken, missing or loose hardware?                               Yes
: 2.
: 3. Is the anchorage free of corrosion that is more than mild surface oxidation?                     Yes
Is the anchorage free of bent, broken, missing or loose hardware?
: 4. Is the anchorage free of visible cracks in the concrete near the anchors?                       Yes
Yes Yes
: 5. Is the anchorage configuration consistent with plant documentation? (Note:                       Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 3.
: 6. Based on the above anchorage evaluations, is the anchorage free of                               Yes potentially adverse seismic conditions?
Is the anchorage free of corrosion that is more than mild surface oxidation?
Interaction Effects C-345
Yes
: 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
Yes
: 5.
Is the anchorage configuration consistent with plant documentation? (Note:
This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Yes
: 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?
Yes Interaction Effects C-345


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N   U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2CES*RAK105 Equipment Class:     (18) Instruments on Racks Equipment
N U
Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2CES*RAK105 Equipment Class:
(18) Instruments on Racks Equipment


== Description:==
== Description:==
RACK (SFC/CMS INSTRUMENTATION)
RACK (SFC/CMS INSTRUMENTATION)
: 7. Are soft targets free from impact by nearby equipment or structures?                           Yes
: 7.
: 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and                 Yes masonry block walls not likely to collapse onto the equipment?
Are soft targets free from impact by nearby equipment or structures?
: 9. Do attached lines have adequate flexibility to avoid damage?                                   Yes
Yes
: 10. Based on the above seismic interaction evaluations, is equipment free of                       Yes potentially adverse seismic interaction effects?
: 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
: 9.
Do attached lines have adequate flexibility to avoid damage?
Yes
: 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
Other Adverse Conditions
: 11. Have you looked for and found no adverse seismic conditions that could                           Yes adversely affect the safety functions of the equipment?
: 11.
Comments Evaluated by:                                   George G Thomas                   Date: 08/23/12 "XA           "    Neda Stoeva 08/23/12 Photos C-346
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by:
George G Thomas Date:
08/23/12 "XA Neda Stoeva 08/23/12 Photos C-346


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CES*RAK105 Equipment Class: (18) Instruments on Racks ipment
Equipment ID No.:
2CES*RAK105 Equipment Class:
(18) Instruments on Racks ipment


== Description:==
== Description:==
Line 116: Line 208:
C-347
C-347


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r-I N     U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r-I N U
Equipment ID No.:     2SWP*MOV17A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SWP*MOV17A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
MOTOR OPERATED GATE VALVE Project:   Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):       SC, 206.00 ft, ALL Manufacturer/Model:
MOTOR OPERATED GATE VALVE Project:
Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):
SC, 206.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
Anchorage
: 1. Is anchorage configuration verification required (i.e., is the item one of the 50%                     No of SWEL items requiring such verification)?
: 1.
: 2. Is the anchorage free of bent, broken, missing or loose hardware?                       Not Applicable
Is anchorage configuration verification required (i.e., is the item one of the 50%
: 3. Is the anchorage free of corrosion that is more than mild surface oxidation?             Not Applicable
of SWEL items requiring such verification)?
: 4. Is the anchorage free of visible cracks in the concrete near the anchors?               Not Applicable
No
: 5. Is the anchorage configuration consistent with plant documentation? (Note:               Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 2.
: 6. Based on the above anchorage evaluations, is the anchorage free of                                 Yes potentially adverse seismic conditions?
Is the anchorage free of bent, broken, missing or loose hardware?
Interaction Effects C-348
Not Applicable
: 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
: 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
: 5.
Is the anchorage configuration consistent with plant documentation? (Note:
This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Not Applicable Not Applicable Not Applicable
: 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?
Yes Interaction Effects C-348


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2SWP*MOV17A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SWP*MOV17A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
MOTOR OPERATED GATE VALVE
MOTOR OPERATED GATE VALVE
: 7. Are soft targets free from impact by nearby equipment or structures?                             Yes
: 7.
: 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and                 Yes masonry block walls not likely to collapse onto the equipment?
Are soft targets free from impact by nearby equipment or structures?
: 9. Do attached lines have adequate flexibility to avoid damage?                                   Yes
Yes
: 10. Based on the above seismic interaction evaluations, is equipment free of                       Yes potentially adverse seismic interaction effects?
: 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
: 9.
Do attached lines have adequate flexibility to avoid damage?
Yes
: 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
Other Adverse Conditions
: 11. Have you looked for and found no adverse seismic conditions that could                           Yes adversely affect the safety functions of the equipment?
: 11.
Comments Evaluated by:         "                          George G Thomas                   Date: 08/23/12 Neda Stoeva                               08/23/12 Photos C-349
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by:
George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 Photos C-349


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N   U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N
Equipment ID No.: 2SWP*MOV17A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves ipment
U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SWP*MOV17A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves ipment


== Description:==
== Description:==
MOTOR OPERATED GATE VALVE MG_0310 C-350
MOTOR OPERATED GATE VALVE MG_0310 C-350


ATTACHMENT 3 WALKDOWN CHECKLISTS Status:       N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2CCP*MOV14A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2CCP*MOV14A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)
GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)
Project:   Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):       SC, 217.00 ft, ALL Manufacturer/Model:
Project:
Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):
SC, 217.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
Anchorage
: 1. Is anchorage configuration verification required (i.e., is the item one of the 50%                   IS0o of SWEL items requiring such verification)?
: 1.
: 2. Is the anchorage free of bent, broken, missing or loose hardware?                       Not Applicable
Is anchorage configuration verification required (i.e., is the item one of the 50%
: 3. Is the anchorage free of corrosion that is more than mild surface oxidation?             Not Applicable
IS of SWEL items requiring such verification)?
: 4. Is the anchorage free of visible cracks in the concrete near the anchors?               Not Applicable
0o
: 5. Is the anchorage configuration consistent with plant documentation? (Note:               Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 2.
: 6. Based on the above anchorage evaluations, is the anchorage free of                                 Yes potentially adverse seismic conditions?
Is the anchorage free of bent, broken, missing or loose hardware?
Interaction Effects C-351
Not Applicable
: 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
: 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
: 5.
Is the anchorage configuration consistent with plant documentation? (Note:
This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Not Applicable Not Applicable Not Applicable
: 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?
Yes Interaction Effects C-351


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:
Equipment ID No.:     2CCP*MOV14A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2CCP*MOV14A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)
GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)
: 7. Are soft targets free from impact by nearby equipment or structures?                             Yes
: 7.
: 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and                   Yes masonry block walls not likely to collapse onto the equipment?
Are soft targets free from impact by nearby equipment or structures?
: 9. Do attached lines have adequate flexibility to avoid damage?                                   Yes
Yes
: 10. Based on the above seismic interaction evaluations, is equipment free of                       Yes potentially adverse seismic interaction effects?
: 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
: 9.
Do attached lines have adequate flexibility to avoid damage?
Yes
: 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
Other Adverse Conditions
: 11. Have you looked for and found no adverse seismic conditions that could                           Yes adversely affect the safety functions of the equipment?
: 11.
Comments Evaluated by:                                 -  George G Thomas                   Date: 08/23/12 Neda Stoeva                               08/23/12 Photos C-352
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by:
George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 Photos C-352


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M   N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CCP*MOV14A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves ipment
Equipment ID No.:
2CCP*MOV14A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves ipment


== Description:==
== Description:==
Line 186: Line 339:
C-353
C-353


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r-j] N     U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r-j] N U
Equipment ID No.:     2SWP*MOV21A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SWP*MOV21A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
SWP to SFC makeup MOV Project:   Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):       SC, 291.00 ft, ALL Manufacturer/Model:
SWP to SFC makeup MOV Project:
Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):
SC, 291.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
Anchorage
: 1. Is anchorage configuration verification required (i.e., is the item one of the 50%                     No of SWEL items requiring such verification)?
: 1.
: 2. Is the anchorage free of bent, broken, missing or loose hardware?                       Not Applicable
Is anchorage configuration verification required (i.e., is the item one of the 50%
: 3. Is the anchorage free of corrosion that is more than mild surface oxidation?             Not Applicable
of SWEL items requiring such verification)?
: 4. Is the anchorage free of visible cracks in the concrete near the anchors?               Not Applicable
No
: 5. Is the anchorage configuration consistent with plant documentation? (Note:               Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 2.
: 6. Based on the above anchorage evaluations, is the anchorage free of                                 Yes potentially adverse seismic conditions?
Is the anchorage free of bent, broken, missing or loose hardware?
Interaction Effects C-354
Not Applicable
: 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
: 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
: 5.
Is the anchorage configuration consistent with plant documentation? (Note:
This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
: 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?
Not Applicable Not Applicable Not Applicable Yes Interaction Effects C-354


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC)
Equipment ID No.:     2SWP*MOV21A Equipment Class:     (8) Motor-Operated and Solenoid-Operated Valves Equipment
Equipment ID No.:
2SWP*MOV21A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves Equipment


== Description:==
== Description:==
SWP to SFC makeup MOV
SWP to SFC makeup MOV
: 7. Are soft targets free from impact by nearby equipment or structures?                             Yes
: 7.
: 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and                   Yes masonry block walls not likely to collapse onto the equipment?
Are soft targets free from impact by nearby equipment or structures?
: 9. Do attached lines have adequate flexibility to avoid damage?                                     Yes
Yes
: 10. Based on the above seismic interaction evaluations, is equipment free of                         Yes potentially adverse seismic interaction effects?
: 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
: 9.
Do attached lines have adequate flexibility to avoid damage?
Yes
: 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
Other Adverse Conditions
: 11. Have you looked for and found no adverse seismic conditions that could                             Yes adversely affect the safety functions of the equipment?
: 11.
Comments Evaluated by:                                   George G Thomas                   Date: 08/23/12 Neda Stoeva                               08/23/12 Photos C-355
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by:
George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 Photos C-355


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M   N   U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2SWP*MOV21A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves ipment
Equipment ID No.:
2SWP*MOV21A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves ipment


== Description:==
== Description:==
SWP to SFC makeup MOV C-356
SWP to SFC makeup MOV C-356


ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N   U Seismic Walkdown Checklist (SWC)
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N
Equipment ID No.: 2SWP*MOV21A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves ipment
U Seismic Walkdown Checklist (SWC)
Equipment ID No.:
2SWP*MOV21A Equipment Class:
(8) Motor-Operated and Solenoid-Operated Valves ipment


== Description:==
== Description:==
Line 231: Line 415:
ATTACHMENT 4 AREA WALK-BY CHECKLIST D
ATTACHMENT 4 AREA WALK-BY CHECKLIST D
Area Walk-By Checklists (AWCs)
Area Walk-By Checklists (AWCs)
Table D-1. Summary of Area Walk-By Checklists AWC                                                               Page No. Build.     El.                     Room-Area-Desc.
Table D-1. Summary of Area Walk-By Checklists AWC Page No.
1 CB     237'-0"     Control Building (Adj. to 2VBA*UPS2C) D-3 2 CB     261'-0"     Remote Shutdown Room                   D-6 3 CBR     261'-0"     Standby Battery Room A                 D-8 4 CSA     261'-0"     Div 1 Switchgear Room                 D-11 5 CCL     261'-0"     Control building HVAV Room             D-20 6 CSA     261'-0"     Div 3 Switchgear Room                 D-25 7 CTR     288'-0"     Cable Chase                           D-30 8 CRR     288'-0"     Relay Room                             D-37 9 CCR     306'-0"     Control Building (Adj. to 2CEC*PNL622) D-38 10 DG     261'-0"     Division 1 DG Control Room             D-44 11 DG     261'-0"     Division 3 DG Control Room             D-48 12 DG     261'-0"     Division 1 Diesel Generator           D-51 13 SW     224'-0"     Div. I Service Building Pump Bay A     D-55 14 SW     261'-0"     Div. I Service Building Pump Bay A     D-59 15 SW     261'-0"     Div. 2 Service Building Pump Bay B     D-63 16 ABN     175'-0"     RHR HX A Room & RHR Pump Room A       D-66 17 N/U     N/U         Not used                               N/A 18 SC     175'-0"     N-E Quadrant                           D-71 19 SC     175'-0"     S-E Quadrant                           D-75 20 SC     175'-0"     RCIC Room                             D-79 D-1
Build.
El.
Room-Area-Desc.
1 CB 237'-0" Control Building (Adj. to 2VBA*UPS2C)
D-3 2
CB 261'-0" Remote Shutdown Room D-6 3
CBR 261'-0" Standby Battery Room A D-8 4
CSA 261'-0" Div 1 Switchgear Room D-11 5
CCL 261'-0" Control building HVAV Room D-20 6
CSA 261'-0" Div 3 Switchgear Room D-25 7
CTR 288'-0" Cable Chase D-30 8
CRR 288'-0" Relay Room D-37 9
CCR 306'-0" Control Building (Adj. to 2CEC*PNL622)
D-38 10 DG 261'-0" Division 1 DG Control Room D-44 11 DG 261'-0" Division 3 DG Control Room D-48 12 DG 261'-0" Division 1 Diesel Generator D-51 13 SW 224'-0" Div. I Service Building Pump Bay A D-55 14 SW 261'-0" Div. I Service Building Pump Bay A D-59 15 SW 261'-0" Div. 2 Service Building Pump Bay B D-63 16 ABN 175'-0" RHR HX A Room & RHR Pump Room A D-66 17 N/U N/U Not used N/A 18 SC 175'-0" N-E Quadrant D-71 19 SC 175'-0" S-E Quadrant D-75 20 SC 175'-0" RCIC Room D-79 D-1


ATTACHMENT 4 AREA WALK-BY CHECKLIST Table D-1. Summary of Area Walk-By Checklists AWC                                                                 Page No. Build.     El.                     Room-Area-Desc.
ATTACHMENT 4 AREA WALK-BY CHECKLIST Table D-1. Summary of Area Walk-By Checklists AWC Page No.
21 ABS     175'-0"     RHR HX B Room                             D-82 22 ABN     196'-0"     RHR HX A Room by MOV 9A                   D-85 23 SC     196'-0"     S-E Quadrant                             D-87 24 SC     196'-0"     North Side                               D-89 25 ABN     215'-0"     Aux Building North                       D-92 26 SC     215'-0"     N-W Quadrant                             D-95 27 SC     215'-0"     S-W Quadrant                             D-98 28 ABN     240'-0"     Aux Building North                       D-103 29 SC     240'-0"     S-E Quadrant                             D-108 30 SC     240'-0"     N-E Quadrant                             D-113 31 SC     261'-0"     S-W Quadrant (Ground Level)               D-117 32 SC     261'-0"     N-W Quadrant (Ground Level).             D-123 33 SC     289'-0"     N-E Quadrant                             D-129 34 SC     289'-0"     N-W Quadrant                             D-136 35 SC     289'-0"     S-E Quadrant                             D-137 36 SC     289'-0"     Spent Fuel Pool Pump Room                 D-142 37 SC     306'-0"     West Side (Adj. to 2GTS*AOV101)           D-144 38 SC     308'-0"     N-W Quadrant (Adj. to 2SFC*SOV54A)       D-146 39 SG     261'-0"     Standby Gas Building A                   D-148 40 PT     255'-0"     Pipe Tunnel (Adj. to 2SWP*MOV599)         D-150 41 SC     184'-0"     RCIC Room (by Valves 21CS*115, 120 & 150) D-153 D-2
Build.
El.
Room-Area-Desc.
21 ABS 175'-0" RHR HX B Room D-82 22 ABN 196'-0" RHR HX A Room by MOV 9A D-85 23 SC 196'-0" S-E Quadrant D-87 24 SC 196'-0" North Side D-89 25 ABN 215'-0" Aux Building North D-92 26 SC 215'-0" N-W Quadrant D-95 27 SC 215'-0" S-W Quadrant D-98 28 ABN 240'-0" Aux Building North D-103 29 SC 240'-0" S-E Quadrant D-108 30 SC 240'-0" N-E Quadrant D-113 31 SC 261'-0" S-W Quadrant (Ground Level)
D-117 32 SC 261'-0" N-W Quadrant (Ground Level).
D-123 33 SC 289'-0" N-E Quadrant D-129 34 SC 289'-0" N-W Quadrant D-136 35 SC 289'-0" S-E Quadrant D-137 36 SC 289'-0" Spent Fuel Pool Pump Room D-142 37 SC 306'-0" West Side (Adj. to 2GTS*AOV101)
D-144 38 SC 308'-0" N-W Quadrant (Adj. to 2SFC*SOV54A)
D-146 39 SG 261'-0" Standby Gas Building A D-148 40 PT 255'-0" Pipe Tunnel (Adj. to 2SWP*MOV599)
D-150 41 SC 184'-0" RCIC Room (by Valves 21CS*115, 120 & 150)
D-153 D-2


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
Location (Bldg, Elev, Room/Area):
Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                           Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
It was noted that 2 VBA *XD2Canchorbolts not aligned,see pictures. - This is not a concern.
It was noted that 2 VBA *XD2C anchor bolts not aligned, see pictures. - This is not a concern.
: 2. Does anchorage of equipment in the area appear to be free of significant                           Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                     Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                   Yes that could cause a fire in the area?
: 5.
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-3
D-3


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area):     Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
U Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                               Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
Comments Evaluated by:
* George G Thomas                   Date:   08/23/12 Neda Stoeva                                    08/23/12 MG_0794                                                   MG_0795 D-4
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0794 MG_0795 D-4


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
Location (Bldg, Elev, Room/Area):
Mr. n7Cl                                             Mr. f7Q7 Mr. n7QR                                             Mr. n7QQ D-5
Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
Mr. n7Cl Mr. f7Q7 Mr. n7QR Mr. n7QQ D-5


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
Location (Bldg, Elev, Room/Area):
MG_0800                                                     MG_0801 Status: YE   U Area Walk-By Checklist (AWC)
Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
Location (Bldg, Elev, Room/Area):     Area 02 - CB, 261'-0" - Remote Shutdown Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
MG_0800 MG_0801 Status:
YE U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 02 - CB, 261'-0" - Remote Shutdown Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                           Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                           Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                     Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                   Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                   Yes that could cause a fire in the area?
: 5.
D-6
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes Yes Yes Yes Yes D-6


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area): Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
U Area Walk-By Checklist (AWC)
: 7. Does it appear that the area is free of potentially adverse seismic interactions                   No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Location (Bldg, Elev, Room/Area):
An interactionwith the display monitorand cabinet set up next to the panel in the room was noted. Addressed in MASP N2-121 1, Seismic Eval # 650. Also, lights have open "S"hooks behind Panel2CES*PNL405. Open 'S' hooks were addressedin CR-2012-008907.
Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)
: 8. Have you looked for and found no other seismic conditions that could                             Yes adversely affect the safety functions of the equipment in the area?
: 7.
Comments Evaluated by:                                 -- George G Thomas                   Date: 08/23/12 Neda Stoeva                             08/23/12 MG_0891                                                     MG_0892 D-7
Does it appear that the area is free of potentially adverse seismic interactions No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
An interaction with the display monitor and cabinet set up next to the panel in the room was noted. Addressed in MASP N2-121 1, Seismic Eval # 650. Also, lights have open "S" hooks behind Panel 2CES*PNL405. Open 'S' hooks were addressed in CR-2012-008907.
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:  
-- George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 MG_0891 MG_0892 D-7


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mi N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mi N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 03 - CBR, 261'-0" - Standby Battery Room A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Location (Bldg, Elev, Room/Area):
Area 03 - CBR, 261'-0" - Standby Battery Room A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
Yes
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
: 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                     Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes Yes Yes
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
: 4.
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 5.
D-8
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes
: 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes D-8


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area):     Area 03 - CBR, 261'-0" - Standby Battery Room A
U Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                           Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Comments Evaluated by:                                   George G Thomas                 Date: 08/23/12 Neda Stoeva                              08/23/12 MG_0811                                                   MG_0812 D-9
Area 03 - CBR, 261'-0" - Standby Battery Room A
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0811 MG_0812 D-9


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 03 - CBR, 261'-0" - Standby Battery Room A Mr. OR1i                                           MG_0814 MG_0815 D-10
Location (Bldg, Elev, Room/Area):
Area 03 - CBR, 261'-0" - Standby Battery Room A Mr. OR1i MG_0814 MG_0815 D-10


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y [-j U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 04 - CSA, 261'-0" - Div 1 Switchgear Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Y [-j U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 04 - CSA, 261'-0" - Div 1 Switchgear Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (ifvisible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                     Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
A potentialinteraction with the SwitchgearJack (a long hooked metal rod) was hooked to a basket behind Panel 2EJS*USI that could fall during an earthquake was noted. Jack issue addressedin TrainingReview Request TRR-2012-483. Also, lights have open "S" hooks above Panel 2EHS*MCCI03C were identified. Open 'S' hooks were addressedin CR-2012-D-11
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
: 7.
Does it appear that the area is free of potentially adverse seismic interactions No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
A potential interaction with the Switchgear Jack (a long hooked metal rod) was hooked to a basket behind Panel 2EJS*USI that could fall during an earthquake was noted. Jack issue addressed in Training Review Request TRR-2012-483. Also, lights have open "S" hooks above Panel 2EHS*MCCI03C were identified. Open 'S' hooks were addressed in CR-2012-D-11


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y W U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 04 - CSA, 261'-0" - Div 1 Switchgear Room 008907.
Y W U Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                           Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Comments Evaluated by:                                   George G Thomas                 Date: 08/23/12 Neda Stoeva                                08/23/12 MG_0825                                                   MG_0826 D-12
Area 04 - CSA, 261'-0" - Div 1 Switchgear Room 008907.
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0825 MG_0826 D-12


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y [-N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
MG 0829                                 Mr WinA D-13
Y [-N U
Area Walk-By Checklist (AWC)
MG 0829 Mr WinA D-13


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y W U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0831                                               MG_0832 MG 0833                                             Mr nA4A MG_0845                                             MG_0846 D-14
Y W U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0831 MG_0832 MG 0833 Mr nA4A MG_0845 MG_0846 D-14


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: YE   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: YE U
Area Walk-By Checklist (AWC)
Mr 08AN D-1 5
Mr 08AN D-1 5


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y W U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0866                                             MG_0868 MG_0871                                             MG_0872 D-16
Y W U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0866 MG_0868 MG_0871 MG_0872 D-16


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y r-] U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 04 - CSA, 261'-0" - Div I Switcl IInM9 Mr. nRA7 M(, 08T7                                           Mr, 0n7R D-17
Y r-] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 04 - CSA, 261'-0" - Div I Switcl IInM9 Mr. nRA7 M(,
08T7 Mr, 0n7R D-17


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y 7N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 04 - CSA, 261'-0" - Div I Switchgear Room MG_0877                                             MG_0878 Mr. 0R79                                             M. nfRRn MG_0894                                             MG_0895 D-18
Y 7N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 04 - CSA, 261'-0" - Div I Switchgear Room MG_0877 MG_0878 Mr. 0R79 M.
nfRRn MG_0894 MG_0895 D-18


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y [-* U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0896 D-1 9
Y [-* U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0896 D-1 9


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: T] N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: T] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 05 - CCL, 261'-0" - Control building HVAV Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Location (Bldg, Elev, Room/Area):
Area 05 - CCL, 261'-0" - Control building HVAV Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                       Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1.
: 2. Does anchorage of equipment in the area appear to be free of significant                       Yes degraded conditions?
Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
: 2.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                     Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-20
D-20


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: 7 N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 05 - CCL, 261'-0" - Control building HVAV Room It was noted that a ladder was not laterallyrestrainedand could hit SWP piping and valves during a strong earthquake. Ladder has since been removed.
7 N
: 8. Have you looked for and found no other seismic conditions that could                         Yes adversely affect the safety functions of the equipment in the area?
U Area Walk-By Checklist (AWC)
Comments Evaluated by:                           --      George G Thomas                 Date: 08/23/12 Neda Stoeva                              08/23/12 MG_0748                                                   MG_0749 D-21
Location (Bldg, Elev, Room/Area):
Area 05 - CCL, 261'-0" - Control building HVAV Room It was noted that a ladder was not laterally restrained and could hit SWP piping and valves during a strong earthquake. Ladder has since been removed.
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0748 MG_0749 D-21


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 05 - CCL, 261'-0" - Control building HVAV Room Mr. n75fn                                             Mr, n751 E     m M(* fl7R                                             M   n f7R1 D-22
Location (Bldg, Elev, Room/Area):
Area 05 - CCL, 261'-0" - Control building HVAV Room Mr. n75fn Mr, n751 E
m M(* fl7R M
n f7R1 D-22


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 05 - CCL, 261'-0" - Control building HVAV Room MG_0756                                             MG_0757 MG_0760                                             MG_0761 D-23
Location (Bldg, Elev, Room/Area):
Area 05 - CCL, 261'-0" - Control building HVAV Room MG_0756 MG_0757 MG_0760 MG_0761 D-23


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Elev, Room/Area): Area 05 - CCL, 261'-0" - Control buildii MG_0764                                           MG_0765 D-24
U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area 05 - CCL, 261'-0" - Control buildii MG_0764 MG_0765 D-24


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M   N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 06 - CSA, 261'-0" - Div 3 Switchgear Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Location (Bldg, Elev, Room/Area):
Area 06 - CSA, 261'-0" - Div 3 Switchgear Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes Yes
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
Yes Yes Yes
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 5.
D-25
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes
: 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes D-25


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 06 - CSA, 261'-0" - Div 3 Switchgear Room
Y N U Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                           Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Comments Evaluated by:                                 - George G Thomas                   Date: 08/23/12 (iv4                   Neda Stoeva                               08/23/12 MG_0774                                                   MG_0775 D-26
Area 06 - CSA, 261'-0" - Div 3 Switchgear Room
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
- George G Thomas Date:
08/23/12 (iv4 Neda Stoeva 08/23/12 MG_0774 MG_0775 D-26


I ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F-] N   U Area Walk-By Checklist (AWC)
I ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F-] N U
Elev, Room/Area): Area 06 - CSA, 261'-0" - Div 3 Switct MG_0777 MG_0776 D-27
Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area 06 - CSA, 261'-0" - Div 3 Switct MG_0777 MG_0776 D-27


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Elev, Room/Area): Area 06 - CSA, 261'-0" - Div 3 Switchgear Room MG_0778 MG_0780                                           MG_0781 D-28
U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area 06 - CSA, 261'-0" - Div 3 Switchgear Room MG_0778 MG_0780 MG_0781 D-28


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
MG 0783 MG_0784                                 MG_0785 D-29
U Area Walk-By Checklist (AWC)
MG 0783 MG_0784 MG_0785 D-29


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [-* N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [-* N U
Location (Bldg, Elev, Room/Area):     Area 07 - CTR, 288'-0" - Cable Chase Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 07 - CTR, 288'-0" - Cable Chase Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                     Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-30
D-30


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 07 - CTR, 288'-0" - Cable Chase
N U Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                     Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Comments Evaluated by:                                   George G Thomas               Date: 08/23/12 Neda Stoeva                           08/23/12 D-31
Area 07 - CTR, 288'-0" - Cable Chase
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Date:
08/23/12 Neda Stoeva 08/23/12 D-31


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area): Area 07 - CTR, 288'-0" - Cable Chase MG_0717 MG_0718 D-32
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 07 - CTR, 288'-0" - Cable Chase MG_0717 MG_0718 D-32


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 07 - CTR, 288'-0" - Cable Chase MG_0720 MG_0721                                               MG_0722 D-33
Location (Bldg, Elev, Room/Area):
Area 07 - CTR, 288'-0" - Cable Chase MG_0720 MG_0721 MG_0722 D-33


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Elev, Room/Area): Area 07 - CTR, 288'-0" - Cable Chase MG_0725                                           MG_0726 D-34
Elev, Room/Area):
Area 07 - CTR, 288'-0" - Cable Chase MG_0725 MG_0726 D-34


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 07 - CTR, 288'-0" - Cable Chase MG_0727 MG_0728 D-35
Y N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 07 - CTR, 288'-0" - Cable Chase MG_0727 MG_0728 D-35


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mf N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mf N U Area Walk-By Checklist (AWC)
Elev, Room/Area): Area 07 - CTR, 288'-0" - Cable Chase MG_0729 D-36
Elev, Room/Area):
Area 07 - CTR, 288'-0" - Cable Chase MG_0729 D-36


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y   E   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 08 - CRR, 288'-0" - Relay Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Y E U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 08 - CRR, 288'-0" - Relay Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                       Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes Yes
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       No interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes
Lighting has open S-hooks near panls 828 and 896. This has been addressedin CR-2012-008907.
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
Lighting has open S-hooks near panls 828 and 896. This has been addressed in CR-2012-008907.
: 7. Does it appear that the area is free of potentially adverse seismic interactions                   No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 5.
D-37
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
No Yes
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
: 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes No D-37


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y l   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 08 - CRR, 288'-0" - Relay Room It was noted that temporary carts should be addressedfor potential interactions. This has been addressed in Training Review Request TRR-2012-483 and CR-2012-008949.
Y l U
: 8. Have you looked for and found no other seismic conditions that could                       Yes adversely affect the safety functions of the equipment in the area?
Area Walk-By Checklist (AWC)
Comments Evaluated by:                         --        George G Thomas             Date: 08/23/12 Neda Stoeva                          08/23/12 MG_0706                                                   MG_0707 D-38
Location (Bldg, Elev, Room/Area):
Area 08 - CRR, 288'-0" - Relay Room It was noted that temporary carts should be addressed for potential interactions. This has been addressed in Training Review Request TRR-2012-483 and CR-2012-008949.
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0706 MG_0707 D-38


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y WI U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y WI U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 08 - CRR, 288'-0" - Relay Room Mr 0708                                             MG 0709 MG_0710                                             MG_0711 D-39
Location (Bldg, Elev, Room/Area):
Area 08 - CRR, 288'-0" - Relay Room Mr 0708 MG 0709 MG_0710 MG_0711 D-39


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: YEE U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: YEE U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)
Location (Bldg, Elev, Room/Area):
Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)
Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
It was noted that there was not much that could be seen due to the finished floor.
It was noted that there was not much that could be seen due to the finished floor.
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
It was noted that the eggcrate diffusers were not clipped in and could adversely effect the Operatorsduring an earthquake. This was addressed in CR-2012-007408.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
It was noted that the eggcrate diffusers were not clipped in and could adversely effect the Operators during an earthquake. This was addressed in CR-2012-007408.
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
D-40
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes Yes Yes Yes Yes D-40


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y 7N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)
Y 7N U
: 7. Does it appear that the area is free of potentially adverse seismic interactions                     No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Area Walk-By Checklist (AWC)
It was noted that temporary equipment (cadillac- core test cabinet)should be stored away from panels. Procedurefolders are mounted on panels - CR-2012-8947 was issued. Perplant personnel- temporary equpiment is allowed per the work processes with appropriaterestncationincluding Work In Progress'identificationto an open WO and properrestraints(chocks, etc.) -
Location (Bldg, Elev, Room/Area):
Also addressedthrough TRR-2012-483 and CR-2012-008949.
Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)
: 8. Have you looked for and found no other seismic conditions that could                               Yes adversely affect the safety functions of the equipment in the area?
: 7.
Comments Evaluated by:                                 --  George G Thomas                   Date: 08/23/12 Neda Stoeva 08/23/12 MG_0669                                                     MG_0670 D-41
Does it appear that the area is free of potentially adverse seismic interactions No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
It was noted that temporary equipment (cadillac - core test cabinet) should be stored away from panels. Procedure folders are mounted on panels - CR-2012-8947 was issued. Per plant personnel-temporary equpiment is allowed per the work processes with appropriate restncation including Work In Progress' identification to an open WO and proper restraints (chocks, etc.) -
Also addressed through TRR-2012-483 and CR-2012-008949.
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0669 MG_0670 D-41


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y r-* U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y r-* U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)
Location (Bldg, Elev, Room/Area):
MG 0672 MG_0673                                             MG_0674 D-42
Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)
MG 0672 MG_0673 MG_0674 D-42


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y -N- U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y -N-U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 09 - CCR,
Location (Bldg, Elev, Room/Area):
                                                        .A Mr. flR7r                                           MG_0676 MG_0677 D-43
Area 09 - CCR,
.A MG_0676 Mr. flR7r MG_0677 D-43


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 10 - DG, 261'-0" - Division 1 DG Control Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Location (Bldg, Elev, Room/Area):
Area 10 - DG, 261'-0" - Division 1 DG Control Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
It was noted that the lights can swing during an earthquake,but were deemed not damaging. However, one light has an open 'S' hook and may fall during an earthquake, this was addressedin CR-2012-006758.
It was noted that the lights can swing during an earthquake, but were deemed not damaging. However, one light has an open 'S' hook and may fall during an earthquake, this was addressed in CR-2012-006758.
: 4. Does it appear that the area is free of potentially adverse seismic spatial                     Yes interactions with other equipment in the area .(e.g., ceiling tiles and lighting)?
: 4.
It was noted there was an unanchoreddesk in the room but not close enough to equipment to impact it during an earthquake. This has been addressedin Training Review Request TRR-2012-483. Also, lights in area need to have hooks closed. This was addressedin CR 2012-006758.
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area.(e.g., ceiling tiles and lighting)?
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
It was noted there was an unanchored desk in the room but not close enough to equipment to impact it during an earthquake. This has been addressed in Training Review Request TRR-2012-483. Also, lights in area need to have hooks closed. This was addressed in CR 2012-006758.
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
D-44
D-44


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):       Area 10 - DG, 261'-0" - Division 1 DG Control Room
N U
: 7. Does it appear that the area is free of potentially adverse seismic interactions               Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                           Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Comments Evaluated by:                               "-  George G Thomas                   Date: 08/23/12
Area 10 - DG, 261'-0" - Division 1 DG Control Room
                                  "            Neda  Stoeva 08/23/12 MG_0047                                                     MG_0048 D-45
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0047 MG_0048 D-45


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area): Area 10 - DG, 261'-0"- Division 1 DG Control Room M. nnAAQ                                           MU nMrn urn   _n-A                                           Mr. nnrr D-46
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 10 - DG, 261'-0"- Division 1 DG Control Room M.
nnAAQ MU nMrn urn
_n-A Mr. nnrr D-46


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 10 - DG, 261'-0" - Division 1 DG Control Room MG_0056                                             MG_0057 MG_0058 D-47
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 10 - DG, 261'-0" - Division 1 DG Control Room MG_0056 MG_0057 MG_0058 D-47


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M   N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area):     Area 11 - DG, 261'-0" - Division 3 DG Control Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 11 - DG, 261'-0" - Division 3 DG Control Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
Yes
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
: 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes
: 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
It was noted that there was an unanchored desk by PNL-413, 3' away. This would not interact with the panel.
It was noted that there was an unanchored desk by PNL-413, 3' away. This would not interact with the panel.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
: 5.
It was noted that light can swing and impact PNL 411. Furtherreview indicated there were no relays in the panels and it was determined that this impact was not damaging.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
It was noted that light can swing and impact PNL 411. Further review indicated there were no relays in the panels and it was determined that this impact was not damaging.
D-48
Yes Yes
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes D-48


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 11 - DG, 261'-0" - Division 3 DG Control Room Everything was well supported.
N U
: 7. Does it appear that the area is free of potentially adverse seismic interactions               Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Area Walk-By Checklist (AWC)
: 8. Have you looked for and found no other seismic conditions that could                           Yes adversely affect the safety functions of the equipment in the area?
Location (Bldg, Elev, Room/Area):
Area 11 - DG, 261'-0" - Division 3 DG Control Room Everything was well supported.
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Bolts and nuts missing on some overhead I-beams. It was determined that this was per design, holes were part of a standard connection that could be modified by putting the bolts in place.
Comments Bolts and nuts missing on some overhead I-beams. It was determined that this was per design, holes were part of a standard connection that could be modified by putting the bolts in place.
S     -    George G Thomas Evaluated by:                                                                         Date: 08/23/12 1*4 Neda Stoeva                                08/23/12 MG_0007                                                     MG_0008 D-49
S George G Thomas Evaluated by:
1*4 Date:
08/23/12 08/23/12 Neda Stoeva MG_0007 MG_0008 D-49


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 11 - DG, 261'-0" - Division 3 DG Control Room MG 0010 MG_0013                                             MG_0014 D-50
N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 11 - DG, 261'-0" - Division 3 DG Control Room MG 0010 MG_0013 MG_0014 D-50


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M   N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 12 - DG, 261'-0" - Division 1 Diesel Generator Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Location (Bldg, Elev, Room/Area):
Area 12 - DG, 261'-0" - Division 1 Diesel Generator Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
Yes
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
: 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes
: 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Lights are secured.
Lights are secured.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
: 5.
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
D-51
Yes Yes
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes D-51


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [7] N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [7] N U
Location (Bldg, Elev, Room/Area):     Area 12 - DG, 261'-0" - Division 1 Diesel Generator
Area Walk-By Checklist (AWC)
: 7. Does it appear that the area is free of potentially adverse seismic interactions                     Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Location (Bldg, Elev, Room/Area):
: 8. Have you looked for and found no other seismic conditions that could                                 Yes adversely affect the safety functions of the equipment in the area?
Area 12 - DG, 261'-0" - Division 1 Diesel Generator
Comments Evaluated by:                               --  George G Thomas                   Date: 08/23/12 Neda Stoeva 08/23/12 MG_0028                                                     MG_0029 D-52
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0028 MG_0029 D-52


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: T N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area): Area 12 - DG, 261'-0" - Division 1 Diesel Generator MG_0032 MG_0033 D-53
T N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 12 - DG, 261'-0" - Division 1 Diesel Generator MG_0032 MG_0033 D-53


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [i- N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [i-N U
Mr 00.4                                 MG_0035 MG_0065 D-54
Area Walk-By Checklist (AWC)
Mr 00.4 MG_0035 MG_0065 D-54


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):     Area 13 - SW, 224'-0"- Div. I Service Building Pump BayA Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Location (Bldg, Elev, Room/Area):
Area 13 - SW, 224'-0"- Div. I Service Building Pump BayA Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
There was suface rust seen on anchorbolts for Service Water Pump 2SWP-PIC. To arrestfurther bolt degradationCR-2012-006807 was issued.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
There was suface rust seen on anchor bolts for Service Water Pump 2SWP-PIC. To arrest further bolt degradation CR-2012-006807 was issued.
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
D-55
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes Yes Yes Yes Yes D-55


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 13 - SW, 224'-0" - Div. I Service Building Pump Bay A
N U Area Walk-By Checklist (AWC)
: 7. Does it appear that the area is free of potentially adverse seismic interactions               Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Location (Bldg, Elev, Room/Area):
: 8. Have you looked for and found no other seismic conditions that could                           Yes adversely affect the safety functions of the equipment in the area?
Area 13 - SW, 224'-0" - Div. I Service Building Pump Bay A
Comments Evaluated by:                                     George G Thomas                   Date: 08/23/12 (j        *%4          Neda Stoeva 08/23/12 MG_0083                                                     MG_0084 D-56
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas (j
*%4 Neda Stoeva Date:
08/23/12 08/23/12 MG_0083 MG_0084 D-56


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F N
Location (Bldg, Elev, Room/A ftAe' AAfO-MG 0085 MG 0087                                     MG_0088 D-57
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/A MG 0085 ftAe' AAfO-MG 0087 MG_0088 D-57


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 13 - SW, 224'-0" - Div. I Service Building Pump Bay A MG_0089                                             MG_0090 MG_0092 MG_0093 D-58
Location (Bldg, Elev, Room/Area):
Area 13 - SW, 224'-0" - Div. I Service Building Pump Bay A MG_0089 MG_0090 MG_0092 MG_0093 D-58


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
Location (Bldg, Elev, Room/Area):     Area 14 - SW, 261'-0" - Div. I Service Building Pump Bay A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 14 - SW, 261'-0" - Div. I Service Building Pump Bay A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
There was suface rust seen on some anchor bolts. To address further degradationthese issues were addressedin CR-2012-006807 and CR-2012-006770.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
There was suface rust seen on some anchor bolts.
To address further degradation these issues were addressed in CR-2012-006807 and CR-2012-006770.
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
D-59
D-59


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):       Area 14 - SW, 261'-0" - Div. I Service Building Pump Bay A
N U Area Walk-By Checklist (AWC)
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Location (Bldg, Elev, Room/Area):
: 8. Have you looked for and found no other seismic conditions that could                             Yes adversely affect the safety functions of the equipment in the area?
Area 14 - SW, 261'-0" - Div. I Service Building Pump Bay A
Comments Evaluated by:                                     George G Thomas                   Date:   08/23/12 Neda Stoeva                                  08/23/12 MG_0124                                                     MG_0125 D-60
: 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/23/12 08/23/12 MG_0124 MG_0125 D-60


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y] N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
                    /, Room/Area): Area 14 - SW, 261'-0" - Div. I Service BL D-61
Y] N U
Area Walk-By Checklist (AWC)
/, Room/Area):
Area 14 - SW, 261'-0" - Div. I Service BL D-61


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: f-V N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: f-V N
Location (Bldg, Elev, Room/Area): Area 14 - SW, 261'-0" - Div. I Service Building Pump BayA MG_0130                                             MG_0131 MG_0132                                             MG_0133 D-62
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 14 - SW, 261'-0" - Div. I Service Building Pump BayA MG_0130 MG_0131 MG_0132 MG_0133 D-62


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: r--] N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: r--] N U
Location (Bldg, Elev, Room/Area):     Area 15 - SW, 261'-0" - Div. 2 Service Building Pump Bay B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 15 - SW, 261'-0" - Div. 2 Service Building Pump Bay B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                           Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 2. Does anchorage of equipment in the area appear to be free of significant                           Yes degraded conditions?
: 2.
The straineranchorshad surface rust issues like Bay A. To arrestfurther degradationthese issues were addressedin CR-2012-006807 and CR-2012-006770.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                     Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
The strainer anchors had surface rust issues like Bay A. To arrest further degradation these issues were addressed in CR-2012-006807 and CR-2012-006770.
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                         Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                   Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                   Yes that could cause a fire in the area?
: 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
D-63
D-63


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 15 - SW, 261'-0" - Div. 2 Service Building Pump Bay B
N U Area Walk-By Checklist (AWC)
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Location (Bldg, Elev, Room/Area):
Desk and storage box chained together,but not chained to anything else (ie.
Area 15 - SW, 261'-0" - Div. 2 Service Building Pump Bay B
structuralmember/tie off) were observed in Service Building Pump Bay B.
: 7.
Vacuum by Service Water train observed. This was moved laterin the day.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8. Have you looked for and found no other seismic conditions that could                             Yes adversely affect the safety functions of the equipment in the area?
Desk and storage box chained together, but not chained to anything else (ie.
Comments
structural member/tie off) were observed in Service Building Pump Bay B.
                                    '-    j ...
Vacuum by Service Water train observed. This was moved later in the day.
_ George G Thomas Evaluated by:                                                                        Date:  08/23/12 4     k-A-4           Neda Stoeva                                 08/23/12 MG_0105                                                     MG_0106 D-64
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
j George G Thomas 4
k-A -4 Neda Stoeva Date:
08/23/12 08/23/12 MG_0105 MG_0106 D-64


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Elev, Room/Area): Area 15 - SW, 261'-0" - Div. 2 Service Buildii MG_0108 MG_0114 D-65
Elev, Room/Area):
Area 15 - SW, 261'-0" - Div. 2 Service Buildii MG_0108 MG_0114 D-65


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y-] N   U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Location (Bldg, Elev, Room/Area):     Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Y-] N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
Additional space is provided at the end of this checklist for documenting other comments.
: 1. Does anchorage of equipment in the area appear to be free of potentially                         Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
: 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
All anchorage was for pipe supports in area.
All anchorage was for pipe supports in area.
: 2. Does anchorage of equipment in the area appear to be free of significant                         Yes degraded conditions?
: 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
No equipment anchorage could be inspected.
No equipment anchorage could be inspected.
: 3. Based on a visual inspection from the floor, do the cable/conduit raceways and                   Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
: 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
: 4. Does it appear that the area is free of potentially adverse seismic spatial                       Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 4.
: 5. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause flooding or spray in the area?
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
: 6. Does it appear that the area is free of potentially adverse seismic interactions                 Yes that could cause a fire in the area?
: 5.
D-66
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
: 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes Yes Yes Yes Yes D-66


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):       Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A
Location (Bldg, Elev, Room/Area):
: 7. Does it appear that the area is free of potentially adverse seismic interactions                 Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A
: 8. Have you looked for and found no other seismic conditions that could                             Yes adversely affect the safety functions of the equipment in the area?
: 7.
Comments Evaluated by:                                     George G Thomas                   Date: 08/23/12 L*      "4      -      Neda Stoeva 08/23/12 MG_0258                                                     MG_0259 D-67
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
: 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas L* "4 -
Neda Stoeva Date:
08/23/12 08/23/12 MG_0258 MG_0259 D-67


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A M(r n,2R.n                                           Mr. nAR1 MG_0262                                             Mr. n!)AR' D-68
Location (Bldg, Elev, Room/Area):
Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A M(r n,2R.n Mr. nAR1 MG_0262 Mr. n!)AR' D-68


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A MG_0266                                             MG_0267 MG_0270                                             MG_0271 D-69
Location (Bldg, Elev, Room/Area):
Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A MG_0266 MG_0267 MG_0270 MG_0271 D-69


ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [ N U Area Walk-By Checklist (AWC)
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [
Elev, Room/Area): Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A MG_0273 MG_0274 D-70}}
N U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A MG_0273 MG_0274 D-70}}

Latest revision as of 20:11, 11 January 2025

Response to 10 CFR 50.54(f) Request for Information, Recommendation 2.3, Seismic, Part 4 of 5
ML12348A084
Person / Time
Site: Nine Mile Point 
Issue date: 11/27/2012
From:
Constellation Energy Nuclear Group, EDF Group
To:
Office of Nuclear Reactor Regulation
References
Download: ML12348A084 (89)


Text

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SFC*P1B Equipment Class:

(5) Horizontal Pumps Equipment

Description:

SFC WATER CIRC PUMP 1B Project:

Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):

SC, 290.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Yes

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

Yes

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

Yes

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes Interaction Effects C-340

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SFC*P1B Equipment Class:

(5) Horizontal Pumps Equipment

Description:

SFC WATER CIRC PUMP 1B

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Evaluated by:

George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 Photos C-341

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SFC*SOV54A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SKIMMER SURGE TANK OUTLET Project:

Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):

SC, 331.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes Interaction Effects C-342

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SFC*SOV54A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SKIMMER SURGE TANK OUTLET

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Evaluated by:

George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 Photos C-343

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SFC*SOV54A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SKIMMER SURGE TANK OUTLET C-344

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2CES*RAK105 Equipment Class:

(18) Instruments on Racks Equipment

Description:

RACK (SFC/CMS INSTRUMENTATION)

Project:

Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):

SC, 261.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

DRW 12177-MS-1930

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Yes Yes

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

Yes

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

Yes

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Yes

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes Interaction Effects C-345

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2CES*RAK105 Equipment Class:

(18) Instruments on Racks Equipment

Description:

RACK (SFC/CMS INSTRUMENTATION)

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Evaluated by:

George G Thomas Date:

08/23/12 "XA Neda Stoeva 08/23/12 Photos C-346

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2CES*RAK105 Equipment Class:

(18) Instruments on Racks ipment

Description:

RACK (SFC/CMS INSTRUMENTATION)

C-347

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r-I N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV17A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

MOTOR OPERATED GATE VALVE Project:

Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):

SC, 206.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes Interaction Effects C-348

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV17A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

MOTOR OPERATED GATE VALVE

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Evaluated by:

George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 Photos C-349

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV17A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves ipment

Description:

MOTOR OPERATED GATE VALVE MG_0310 C-350

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2CCP*MOV14A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)

Project:

Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):

SC, 217.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

IS of SWEL items requiring such verification)?

0o

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes Interaction Effects C-351

ATTACHMENT 3 WALKDOWN CHECKLISTS Status:

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2CCP*MOV14A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Evaluated by:

George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 Photos C-352

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2CCP*MOV14A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves ipment

Description:

GATE VALVE SFC*E1A INLET (MOTOR OPERATED VALVE)

C-353

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r-j] N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV21A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SWP to SFC makeup MOV Project:

Nine Mile 2 SWEL Location (Bldg, Elev, Room/Area):

SC, 291.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Not Applicable Not Applicable Not Applicable Yes Interaction Effects C-354

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV21A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SWP to SFC makeup MOV

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Evaluated by:

George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 Photos C-355

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV21A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves ipment

Description:

SWP to SFC makeup MOV C-356

ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

2SWP*MOV21A Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves ipment

Description:

SWP to SFC makeup MOV C-357

ATTACHMENT (4)

AREA WALK-BY CHECKLIST Constellation Energy Nuclear Group, LLC November 27, 2012

ATTACHMENT 4 AREA WALK-BY CHECKLIST D

Area Walk-By Checklists (AWCs)

Table D-1. Summary of Area Walk-By Checklists AWC Page No.

Build.

El.

Room-Area-Desc.

1 CB 237'-0" Control Building (Adj. to 2VBA*UPS2C)

D-3 2

CB 261'-0" Remote Shutdown Room D-6 3

CBR 261'-0" Standby Battery Room A D-8 4

CSA 261'-0" Div 1 Switchgear Room D-11 5

CCL 261'-0" Control building HVAV Room D-20 6

CSA 261'-0" Div 3 Switchgear Room D-25 7

CTR 288'-0" Cable Chase D-30 8

CRR 288'-0" Relay Room D-37 9

CCR 306'-0" Control Building (Adj. to 2CEC*PNL622)

D-38 10 DG 261'-0" Division 1 DG Control Room D-44 11 DG 261'-0" Division 3 DG Control Room D-48 12 DG 261'-0" Division 1 Diesel Generator D-51 13 SW 224'-0" Div. I Service Building Pump Bay A D-55 14 SW 261'-0" Div. I Service Building Pump Bay A D-59 15 SW 261'-0" Div. 2 Service Building Pump Bay B D-63 16 ABN 175'-0" RHR HX A Room & RHR Pump Room A D-66 17 N/U N/U Not used N/A 18 SC 175'-0" N-E Quadrant D-71 19 SC 175'-0" S-E Quadrant D-75 20 SC 175'-0" RCIC Room D-79 D-1

ATTACHMENT 4 AREA WALK-BY CHECKLIST Table D-1. Summary of Area Walk-By Checklists AWC Page No.

Build.

El.

Room-Area-Desc.

21 ABS 175'-0" RHR HX B Room D-82 22 ABN 196'-0" RHR HX A Room by MOV 9A D-85 23 SC 196'-0" S-E Quadrant D-87 24 SC 196'-0" North Side D-89 25 ABN 215'-0" Aux Building North D-92 26 SC 215'-0" N-W Quadrant D-95 27 SC 215'-0" S-W Quadrant D-98 28 ABN 240'-0" Aux Building North D-103 29 SC 240'-0" S-E Quadrant D-108 30 SC 240'-0" N-E Quadrant D-113 31 SC 261'-0" S-W Quadrant (Ground Level)

D-117 32 SC 261'-0" N-W Quadrant (Ground Level).

D-123 33 SC 289'-0" N-E Quadrant D-129 34 SC 289'-0" N-W Quadrant D-136 35 SC 289'-0" S-E Quadrant D-137 36 SC 289'-0" Spent Fuel Pool Pump Room D-142 37 SC 306'-0" West Side (Adj. to 2GTS*AOV101)

D-144 38 SC 308'-0" N-W Quadrant (Adj. to 2SFC*SOV54A)

D-146 39 SG 261'-0" Standby Gas Building A D-148 40 PT 255'-0" Pipe Tunnel (Adj. to 2SWP*MOV599)

D-150 41 SC 184'-0" RCIC Room (by Valves 21CS*115, 120 & 150)

D-153 D-2

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?

It was noted that 2 VBA *XD2C anchor bolts not aligned, see pictures. - This is not a concern.

2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-3

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0794 MG_0795 D-4

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)

Mr. n7Cl Mr. f7Q7 Mr. n7QR Mr. n7QQ D-5

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)

MG_0800 MG_0801 Status:

YE U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 02 - CB, 261'-0" - Remote Shutdown Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes Yes Yes Yes Yes Yes D-6

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 01 - CB, 237'-0" - Control Building (Adj. to 2VBA*UPS2C)

7.

Does it appear that the area is free of potentially adverse seismic interactions No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

An interaction with the display monitor and cabinet set up next to the panel in the room was noted. Addressed in MASP N2-121 1, Seismic Eval # 650. Also, lights have open "S" hooks behind Panel 2CES*PNL405. Open 'S' hooks were addressed in CR-2012-008907.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

-- George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 MG_0891 MG_0892 D-7

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mi N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 03 - CBR, 261'-0" - Standby Battery Room A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes

2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Yes Yes Yes

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Yes

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes

7.

Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes D-8

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 03 - CBR, 261'-0" - Standby Battery Room A

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0811 MG_0812 D-9

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 03 - CBR, 261'-0" - Standby Battery Room A Mr. OR1i MG_0814 MG_0815 D-10

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y [-j U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div 1 Switchgear Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A potential interaction with the Switchgear Jack (a long hooked metal rod) was hooked to a basket behind Panel 2EJS*USI that could fall during an earthquake was noted. Jack issue addressed in Training Review Request TRR-2012-483. Also, lights have open "S" hooks above Panel 2EHS*MCCI03C were identified. Open 'S' hooks were addressed in CR-2012-D-11

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y W U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div 1 Switchgear Room 008907.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0825 MG_0826 D-12

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y [-N U

Area Walk-By Checklist (AWC)

MG 0829 Mr WinA D-13

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y W U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0831 MG_0832 MG 0833 Mr nA4A MG_0845 MG_0846 D-14

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: YE U

Area Walk-By Checklist (AWC)

Mr 08AN D-1 5

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y W U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0866 MG_0868 MG_0871 MG_0872 D-16

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y r-] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div I Switcl IInM9 Mr. nRA7 M(,

08T7 Mr, 0n7R D-17

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y 7N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div I Switchgear Room MG_0877 MG_0878 Mr. 0R79 M.

nfRRn MG_0894 MG_0895 D-18

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y [-* U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 04 - CSA, 261'-0" - Div 1 Switchgear Room MG_0896 D-1 9

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: T] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 05 - CCL, 261'-0" - Control building HVAV Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1.

Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?

2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-20

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

7 N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 05 - CCL, 261'-0" - Control building HVAV Room It was noted that a ladder was not laterally restrained and could hit SWP piping and valves during a strong earthquake. Ladder has since been removed.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0748 MG_0749 D-21

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 05 - CCL, 261'-0" - Control building HVAV Room Mr. n75fn Mr, n751 E

m M(* fl7R M

n f7R1 D-22

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 05 - CCL, 261'-0" - Control building HVAV Room MG_0756 MG_0757 MG_0760 MG_0761 D-23

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 05 - CCL, 261'-0" - Control buildii MG_0764 MG_0765 D-24

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 06 - CSA, 261'-0" - Div 3 Switchgear Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes Yes

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes Yes Yes

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes

7.

Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes D-25

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 06 - CSA, 261'-0" - Div 3 Switchgear Room

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

- George G Thomas Date:

08/23/12 (iv4 Neda Stoeva 08/23/12 MG_0774 MG_0775 D-26

I ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F-] N U

Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 06 - CSA, 261'-0" - Div 3 Switct MG_0777 MG_0776 D-27

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 06 - CSA, 261'-0" - Div 3 Switchgear Room MG_0778 MG_0780 MG_0781 D-28

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

MG 0783 MG_0784 MG_0785 D-29

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [-* N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-30

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Date:

08/23/12 Neda Stoeva 08/23/12 D-31

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase MG_0717 MG_0718 D-32

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase MG_0720 MG_0721 MG_0722 D-33

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase MG_0725 MG_0726 D-34

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase MG_0727 MG_0728 D-35

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mf N U Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 07 - CTR, 288'-0" - Cable Chase MG_0729 D-36

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y E U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 08 - CRR, 288'-0" - Relay Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes Yes

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Yes

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Lighting has open S-hooks near panls 828 and 896. This has been addressed in CR-2012-008907.

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

No Yes

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes No D-37

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y l U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 08 - CRR, 288'-0" - Relay Room It was noted that temporary carts should be addressed for potential interactions. This has been addressed in Training Review Request TRR-2012-483 and CR-2012-008949.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0706 MG_0707 D-38

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y WI U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 08 - CRR, 288'-0" - Relay Room Mr 0708 MG 0709 MG_0710 MG_0711 D-39

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: YEE U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

It was noted that there was not much that could be seen due to the finished floor.

2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

It was noted that the eggcrate diffusers were not clipped in and could adversely effect the Operators during an earthquake. This was addressed in CR-2012-007408.

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes Yes Yes Yes Yes Yes D-40

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y 7N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)

7.

Does it appear that the area is free of potentially adverse seismic interactions No associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

It was noted that temporary equipment (cadillac - core test cabinet) should be stored away from panels. Procedure folders are mounted on panels - CR-2012-8947 was issued. Per plant personnel-temporary equpiment is allowed per the work processes with appropriate restncation including Work In Progress' identification to an open WO and proper restraints (chocks, etc.) -

Also addressed through TRR-2012-483 and CR-2012-008949.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0669 MG_0670 D-41

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y r-* U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 09 - CCR, 306'-0" - Control Building (Adj. to 2CEC*PNL622)

MG 0672 MG_0673 MG_0674 D-42

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y -N-U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 09 - CCR,

.A MG_0676 Mr. flR7r MG_0677 D-43

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - DG, 261'-0" - Division 1 DG Control Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

It was noted that the lights can swing during an earthquake, but were deemed not damaging. However, one light has an open 'S' hook and may fall during an earthquake, this was addressed in CR-2012-006758.

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area.(e.g., ceiling tiles and lighting)?

It was noted there was an unanchored desk in the room but not close enough to equipment to impact it during an earthquake. This has been addressed in Training Review Request TRR-2012-483. Also, lights in area need to have hooks closed. This was addressed in CR 2012-006758.

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

D-44

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - DG, 261'-0" - Division 1 DG Control Room

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0047 MG_0048 D-45

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - DG, 261'-0"- Division 1 DG Control Room M.

nnAAQ MU nMrn urn

_n-A Mr. nnrr D-46

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - DG, 261'-0" - Division 1 DG Control Room MG_0056 MG_0057 MG_0058 D-47

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 11 - DG, 261'-0" - Division 3 DG Control Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes

2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Yes

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

It was noted that there was an unanchored desk by PNL-413, 3' away. This would not interact with the panel.

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

It was noted that light can swing and impact PNL 411. Further review indicated there were no relays in the panels and it was determined that this impact was not damaging.

Yes Yes

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes D-48

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 11 - DG, 261'-0" - Division 3 DG Control Room Everything was well supported.

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Bolts and nuts missing on some overhead I-beams. It was determined that this was per design, holes were part of a standard connection that could be modified by putting the bolts in place.

S George G Thomas Evaluated by:

1*4 Date:

08/23/12 08/23/12 Neda Stoeva MG_0007 MG_0008 D-49

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 11 - DG, 261'-0" - Division 3 DG Control Room MG 0010 MG_0013 MG_0014 D-50

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 12 - DG, 261'-0" - Division 1 Diesel Generator Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes

2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Yes

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Lights are secured.

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Yes Yes

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes D-51

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [7] N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 12 - DG, 261'-0" - Division 1 Diesel Generator

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0028 MG_0029 D-52

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

T N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 12 - DG, 261'-0" - Division 1 Diesel Generator MG_0032 MG_0033 D-53

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [i-N U

Area Walk-By Checklist (AWC)

Mr 00.4 MG_0035 MG_0065 D-54

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 13 - SW, 224'-0"- Div. I Service Building Pump BayA Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

There was suface rust seen on anchor bolts for Service Water Pump 2SWP-PIC. To arrest further bolt degradation CR-2012-006807 was issued.

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes Yes Yes Yes Yes Yes D-55

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 13 - SW, 224'-0" - Div. I Service Building Pump Bay A

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas (j

  • %4 Neda Stoeva Date:

08/23/12 08/23/12 MG_0083 MG_0084 D-56

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/A MG 0085 ftAe' AAfO-MG 0087 MG_0088 D-57

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 13 - SW, 224'-0" - Div. I Service Building Pump Bay A MG_0089 MG_0090 MG_0092 MG_0093 D-58

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 14 - SW, 261'-0" - Div. I Service Building Pump Bay A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

There was suface rust seen on some anchor bolts.

To address further degradation these issues were addressed in CR-2012-006807 and CR-2012-006770.

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

D-59

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 14 - SW, 261'-0" - Div. I Service Building Pump Bay A

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/23/12 08/23/12 MG_0124 MG_0125 D-60

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y] N U

Area Walk-By Checklist (AWC)

/, Room/Area):

Area 14 - SW, 261'-0" - Div. I Service BL D-61

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: f-V N

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 14 - SW, 261'-0" - Div. I Service Building Pump BayA MG_0130 MG_0131 MG_0132 MG_0133 D-62

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: r--] N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 15 - SW, 261'-0" - Div. 2 Service Building Pump Bay B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

The strainer anchors had surface rust issues like Bay A. To arrest further degradation these issues were addressed in CR-2012-006807 and CR-2012-006770.

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

D-63

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 15 - SW, 261'-0" - Div. 2 Service Building Pump Bay B

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Desk and storage box chained together, but not chained to anything else (ie.

structural member/tie off) were observed in Service Building Pump Bay B.

Vacuum by Service Water train observed. This was moved later in the day.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

j George G Thomas 4

k-A -4 Neda Stoeva Date:

08/23/12 08/23/12 MG_0105 MG_0106 D-64

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 15 - SW, 261'-0" - Div. 2 Service Buildii MG_0108 MG_0114 D-65

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:

Y-] N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

All anchorage was for pipe supports in area.

2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

No equipment anchorage could be inspected.

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes Yes Yes Yes Yes Yes D-66

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas L* "4 -

Neda Stoeva Date:

08/23/12 08/23/12 MG_0258 MG_0259 D-67

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A M(r n,2R.n Mr. nAR1 MG_0262 Mr. n!)AR' D-68

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A MG_0266 MG_0267 MG_0270 MG_0271 D-69

ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [

N U Area Walk-By Checklist (AWC)

Elev, Room/Area):

Area 16 - ABN, 175'-0" - RHR HX A Room & RHR Pump Room A MG_0273 MG_0274 D-70