ML16341A850: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(7 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML16341A850
| number = ML16341A850
| issue date = 10/24/2016
| issue date = 10/24/2016
| title = Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 5, Table 5.2-5 - Summary Of Analyses-Jet Forces Impacting On Internal Structures. Page 1 of 2
| title = 7 to Updated Final Safety Analysis Report, Chapter 5, Table 5.2-5 - Summary of Analyses-Jet Forces Impacting on Internal Structures. Page 1 of 2
| author name =  
| author name =  
| author affiliation = Indiana Michigan Power Co
| author affiliation = Indiana Michigan Power Co
Line 15: Line 15:
| page count = 2
| page count = 2
}}
}}
=Text=
{{#Wiki_filter:IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.2-5 Page:
1 of 2
==SUMMARY==
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)
Critical Target Normal Operating Pressure Psia.
Jet Effect Remarks Break #1 29"I.D.
614'-0" Note 1 (2) 2250 c
#2 27.5"I.D.
614'-0" Note (1) (2) 2250 c
#3 29"I.D.
615'-0"+
23.02 Crane Wall 2250 c
#4 31"I.D.
612'-9"+
37.0 (2)
Operating Deck 2250 d
#5 31"I.D.
607'-9"+
42.0(2)
Operating Deck 2250 d
#6 27.5"I.D.
614'-0" 11.0(2)
Crane Wall 2250 d
#7 29"I.D.
615'-3+
39.5(2)
Operating Deck 2250 c
#8 31"I.D.
607'-9"+
42.0(2)
Operating Deck 2250 d
#9 31"I.D.
603-8 1/4 13.0(2)
Crane Wall 2250 d
#10 27.5"I.D.
614'-0" 14.0 Crane Wall 2250 d
#113 29"I.D.
614'-0" 19.54 Crane Wall 2250 c
#125 29"I.D.
614'-0" 20.0 Crane Wall 2250 c
#13 11"I.D.
620'-0"+
6.0(4)
Pressurizer Slab 2250 d
#14 30"I.D.
686'-10 3/16" 16.0 Steam Gen.
Encl 1020 d
1 Jet blocked; restraints prevent further movement.
2 This break does not require consideration of Jet Forces since LBB methodology adopted. Maintained for historical purposes.
3 Surge line connection on loop 3 only.
4 Unit 2 only. LBB accepted for Unit 1.
5 14 connection on loop 2 only.
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.2-5 Page:
2 of 2
==SUMMARY==
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)
Critical Target Normal Operating Pressure Psia.
Jet Effect Remarks
#15 28"I.D.
635'-0" 4.0 Containment Wall 1020 d}}

Latest revision as of 18:19, 9 January 2025

7 to Updated Final Safety Analysis Report, Chapter 5, Table 5.2-5 - Summary of Analyses-Jet Forces Impacting on Internal Structures. Page 1 of 2
ML16341A850
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16341A850 (2)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

5.2-5 Page:

1 of 2

SUMMARY

OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)

Critical Target Normal Operating Pressure Psia.

Jet Effect Remarks Break #1 29"I.D.

614'-0" Note 1 (2) 2250 c

  1. 2 27.5"I.D.

614'-0" Note (1) (2) 2250 c

  1. 3 29"I.D.

615'-0"+

23.02 Crane Wall 2250 c

  1. 4 31"I.D.

612'-9"+

37.0 (2)

Operating Deck 2250 d

  1. 5 31"I.D.

607'-9"+

42.0(2)

Operating Deck 2250 d

  1. 6 27.5"I.D.

614'-0" 11.0(2)

Crane Wall 2250 d

  1. 7 29"I.D.

615'-3+

39.5(2)

Operating Deck 2250 c

  1. 8 31"I.D.

607'-9"+

42.0(2)

Operating Deck 2250 d

  1. 9 31"I.D.

603-8 1/4 13.0(2)

Crane Wall 2250 d

  1. 10 27.5"I.D.

614'-0" 14.0 Crane Wall 2250 d

  1. 113 29"I.D.

614'-0" 19.54 Crane Wall 2250 c

  1. 125 29"I.D.

614'-0" 20.0 Crane Wall 2250 c

  1. 13 11"I.D.

620'-0"+

6.0(4)

Pressurizer Slab 2250 d

  1. 14 30"I.D.

686'-10 3/16" 16.0 Steam Gen.

Encl 1020 d

1 Jet blocked; restraints prevent further movement.

2 This break does not require consideration of Jet Forces since LBB methodology adopted. Maintained for historical purposes.

3 Surge line connection on loop 3 only.

4 Unit 2 only. LBB accepted for Unit 1.

5 14 connection on loop 2 only.

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

5.2-5 Page:

2 of 2

SUMMARY

OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)

Critical Target Normal Operating Pressure Psia.

Jet Effect Remarks

  1. 15 28"I.D.

635'-0" 4.0 Containment Wall 1020 d