ENS 44961: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 10/18/2007 CDT | | event date = 10/18/2007 CDT | ||
| last update date = 04/08/2009 | | last update date = 04/08/2009 | ||
| title = Agreement State Report - Inability | | title = Agreement State Report - Inability to Retract Radiography Source | ||
| event text = The following information was received from the State of Texas via Email: | | event text = The following information was received from the State of Texas via Email: | ||
On November 9 2007, the agency was notified by the licensee of an event that occurred while they were performing radiography operations at a remote location. The licensee reported that the guide tube on a radiography camera containing a 75 curie Iridium (Ir) - 192 source was damaged, preventing them from being able to retrieve the radiation source back into the camera. The radiographer contacted the licensee's main office and was instructed to monitor the area and restrict access until the source retrieval supervisor arrived at the location. The supervisor was able to remove the crimp in the guide tube, allowing them to sufficiently retract the source into the camera. No exposures were received that exceeded regulatory limits. The licensee is redesigning their holder to prevent this from occurring in the future and provided additional training to their personnel. This event is closed. | On November 9 2007, the agency was notified by the licensee of an event that occurred while they were performing radiography operations at a remote location. The licensee reported that the guide tube on a radiography camera containing a 75 curie Iridium (Ir) - 192 source was damaged, preventing them from being able to retrieve the radiation source back into the camera. The radiographer contacted the licensee's main office and was instructed to monitor the area and restrict access until the source retrieval supervisor arrived at the location. The supervisor was able to remove the crimp in the guide tube, allowing them to sufficiently retract the source into the camera. No exposures were received that exceeded regulatory limits. The licensee is redesigning their holder to prevent this from occurring in the future and provided additional training to their personnel. This event is closed. |
Latest revision as of 21:12, 1 March 2018
Where | |
---|---|
Metco Houston, Texas (NRC Region 4) | |
License number: | 03018 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+12781.62 h532.568 days <br />76.081 weeks <br />17.508 months <br />) | |
Opened: | Art Tucker 18:37 Apr 2, 2009 |
NRC Officer: | Vince Klco |
Last Updated: | Apr 8, 2009 |
44961 - NRC Website | |