ENS 46847: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 05/12/2011 18:25 CDT
| event date = 05/12/2011 18:25 CDT
| last update date = 05/13/2011
| last update date = 05/13/2011
| title = Loss Of Shutdown Cooling
| title = Loss of Shutdown Cooling
| event text = At 1825 CDT on 05/12/2011, with  Browns Ferry Nuclear Plant Unit 3 in Mode 4, Browns Ferry Nuclear Plant PCIS [Primary Containment Isolation System] relay maintenance activities for a Group 1 PCIS relay inadvertently interrupted the neutral for a Group 2 PCIS relay and a Group 2 PCIS isolation occurred resulting in a loss of Shutdown Cooling. Relays were reset and Shutdown Cooling was restored at 1905 CDT. Moderator temperature prior to the event was 112.5 degrees F and the highest moderator temperature recorded during the loss of Shutdown Cooling was 122 degrees F.
| event text = At 1825 CDT on 05/12/2011, with  Browns Ferry Nuclear Plant Unit 3 in Mode 4, Browns Ferry Nuclear Plant PCIS [Primary Containment Isolation System] relay maintenance activities for a Group 1 PCIS relay inadvertently interrupted the neutral for a Group 2 PCIS relay and a Group 2 PCIS isolation occurred resulting in a loss of Shutdown Cooling. Relays were reset and Shutdown Cooling was restored at 1905 CDT. Moderator temperature prior to the event was 112.5 degrees F and the highest moderator temperature recorded during the loss of Shutdown Cooling was 122 degrees F.
This condition is reportable under 10CFR50.72(b)(3)(v) - Any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to:  B.) Remove residual heat.  
This condition is reportable under 10CFR50.72(b)(3)(v) - Any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to:  B.) Remove residual heat.  

Latest revision as of 22:07, 1 March 2018

ENS 46847 +/-
Where
Browns Ferry Tennessee Valley Authority icon.png
Alabama (NRC Region 2)
Reporting
10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat
Time - Person (Reporting Time:+2.47 h0.103 days <br />0.0147 weeks <br />0.00338 months <br />)
Opened: Ricky Givens
01:53 May 13, 2011
NRC Officer: John Knoke
Last Updated: May 13, 2011
46847 - NRC Website