ENS 50600: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 11/06/2014 11:16 MST
| event date = 11/06/2014 11:16 MST
| last update date = 11/07/2014
| last update date = 11/07/2014
| title = Technical Specification Required Shutdown Due To Dropped Control Element Assembly
| title = Technical Specification Required Shutdown Due to Dropped Control Element Assembly
| event text = On November 6, 2014 at 1116 Mountain Standard Time (MST), Control Element Assembly (CEA) 15 dropped fully into the core while all other CEAs remained fully withdrawn. Limiting Condition for Operation (LCO) 3.1.5 Condition A was entered for one CEA misaligned from its group which requires restoration of the CEA within 2 hours. An initial power reduction was performed upon receipt of the deviation in accordance with technical specifications. The CEA could not be aligned within 2 hours and LCO 3.1.5 Condition C was entered at 1316 MST which requires entry into Mode 3 within 6 hours. Power reduction continues as necessary to comply with technical specifications.
| event text = On November 6, 2014 at 1116 Mountain Standard Time (MST), Control Element Assembly (CEA) 15 dropped fully into the core while all other CEAs remained fully withdrawn. Limiting Condition for Operation (LCO) 3.1.5 Condition A was entered for one CEA misaligned from its group which requires restoration of the CEA within 2 hours. An initial power reduction was performed upon receipt of the deviation in accordance with technical specifications. The CEA could not be aligned within 2 hours and LCO 3.1.5 Condition C was entered at 1316 MST which requires entry into Mode 3 within 6 hours. Power reduction continues as necessary to comply with technical specifications.
No major equipment was inoperable prior to the event that contributed to the event. No emergency classification was required per the Emergency Plan. No automatic essential safety feature actuations occurred and none were required. The Emergency Diesel Generators did not start and were not required. Safety related buses remain energized. The offsite power grid is stable. Other LCOs were entered as required by technical specifications.
No major equipment was inoperable prior to the event that contributed to the event. No emergency classification was required per the Emergency Plan. No automatic essential safety feature actuations occurred and none were required. The Emergency Diesel Generators did not start and were not required. Safety related buses remain energized. The offsite power grid is stable. Other LCOs were entered as required by technical specifications.

Latest revision as of 20:49, 1 March 2018

ENS 50600 +/-
Where
Palo Verde Arizona Public Service icon.png
Arizona (NRC Region 4)
Reporting
10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown
LER: 05000529/LER-2014-002
Time - Person (Reporting Time:+0.1 h0.00417 days <br />5.952381e-4 weeks <br />1.3698e-4 months <br />)
Opened: Robert Warner
18:22 Nov 6, 2014
NRC Officer: Dong Park
Last Updated: Nov 7, 2014
50600 - NRC Website
Loading map...