{{#Wiki_filter:n                                                                                                                   i
{{#Wiki_filter:n i
  .' s .
s April 19,1999 Mr. Harold B. Ray Executive Vice President Southem California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, California 92674-0128
April 19,1999 Mr. Harold B. Ray Executive Vice President Southem California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, California 92674-0128


==SUBJECT:==
==SUBJECT:==
Line 25: Line 26:


==Dear Mr. Ray:==
==Dear Mr. Ray:==
 
By {{letter dated|date=August 26, 1998|text=letter dated August 26,1998}}, you submitted a request for relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI requirements for certain inservice inspections at San Onofre Nuclear Generating Station, Units 2 and 3. In place of the ASME Code requirement for performing radiographic inservice inspections with plaque penetrameters, you proposed an attemative that would use wire penetrameters. On the basis of the enclosed evaluation, the staff has determined that the proposed altemative will provide an acceptable level of quality and safety. Therefore, the attemative is authorized pursuant to 10 CFR 50.55a(a)(3(i).
By letter dated August 26,1998, you submitted a request for relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI requirements for certain inservice inspections at San Onofre Nuclear Generating Station, Units 2 and 3. In place of the ASME Code requirement for performing radiographic inservice inspections with plaque penetrameters, you proposed an attemative that would use wire penetrameters. On the basis                 l of the enclosed evaluation, the staff has determined that the proposed altemative will provide             I an acceptable level of quality and safety. Therefore, the attemative is authorized pursuant to             !
Sincerely, ORIG. SIGNED BY Steve Dembek, Chief, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 DISTRIBUTION:
10 CFR 50.55a(a)(3(i).                                                                                     I Sincerely, ORIG. SIGNED BY                                             l Steve Dembek, Chief, Section 2                               '
and 50-362 eDoduthe KBrockman, Region IV PUBLIC LSmith, Region IV
Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361                           DISTRIBUTION:
and 50-362                       eDoduthe                 KBrockman, Region IV PUBLIC                 LSmith, Region IV


==Enclosure:==
==Enclosure:==
Safety Evaluation                 PDIV Reading           RCN (SE)
Safety Evaluation PDIV Reading RCN (SE)
JZwolinski/SBlack     DNaujock cc w/ encl: See next page                     SRichards             WBateman LRaghavan EPeyton ACRS
JZwolinski/SBlack DNaujock cc w/ encl: See next page SRichards WBateman LRaghavan EPeyton ACRS
          *For previous concurrences                   OGC see attached ORC                             GHill(2) f Document Name: A:\MA3430SE.WPD l
*For previous concurrences OGC see attached ORC GHill(2) f Document Name: A:\\MA3430SE.WPD l
OFC       PDIV-2 .       PDIV-2           OGC*               PDIV-2 W .om,                                                 s                       ,.
OFC PDIV-2.
NAME     LRaghaven       EPeytoh'         RBachmann         SDembek ff s                   ,_      U DATE~     4 /l1 /99     4 / l b /99       4 /15 /99         4 /M/99 OFFICIAL RECORD COPY v neu                 ~
PDIV-2 OGC*
9904210329 990419 PDR     ADOCK 05000361 P                     PDR f
PDIV-2 W.om, s
NAME LRaghaven EPeytoh' RBachmann SDembek ff s U
DATE~
4 /l1 /99 4 / l b /99 4 /15 /99 4 /M/99 OFFICIAL RECORD COPY v neu
~
9904210329 990419 PDR ADOCK 05000361 P
PDR f


o ,
o l ~
l ~
Mr. Harold B. Ray Executive Vice President l
Mr. Harold B. Ray Executive Vice President l     Southern California Edison Company l     San Onofre Nuclear Generating Station P. O. Box 128 l
Southern California Edison Company l
San Onofre Nuclear Generating Station P. O. Box 128 l
San Clemente, California 92674-0128
San Clemente, California 92674-0128


==SUBJECT:==
==SUBJECT:==
EVALUATION OF WIRE PENETRAMETERS FO                   SERVICE INSPECTION RADIOGRAPHY, SAN ONOFRE NUCLEAR G                   RATING STATIONS, UNITS 2 AND 3 (TAC NOS. MA3430 AND MA3431)
EVALUATION OF WIRE PENETRAMETERS FO SERVICE INSPECTION RADIOGRAPHY, SAN ONOFRE NUCLEAR G RATING STATIONS, UNITS 2 AND 3 (TAC NOS. MA3430 AND MA3431)


==Dear Mr. Ray:==
==Dear Mr. Ray:==
 
By {{letter dated|date=August 26, 1998|text=letter dated August 26,1998}}, you submitted a re est for relief from the American Society of Mechanical Engineers (ArNIE) Boiler and Pressur. Vessel Code, Section XI requirements for certain inservice inspections at San Onofre Nuc ar Generating Station, Units 2 and 3. In place of the ASME Code requirement for performi radiographic inservice inspections with plaque penetrameters, you proposed an alternativ at would use wire penetrameters. On the basis of tne enclosed evaluation, the staff has termined that the proposed alternative will provide j
By letter dated August 26,1998, you submitted a re est for relief from the American Society of Mechanical Engineers (ArNIE) Boiler and Pressur . Vessel Code, Section XI requirements for certain inservice inspections at San Onofre Nuc ar Generating Station, Units 2 and 3. In place   ;
an acceptable level of quality and safet Therefore, the alternative is authorized pursuant to 10 CFR 50.55a(a)(3(i).
of the ASME Code requirement for performi radiographic inservice inspections with plaque penetrameters, you proposed an alternativ     at would use wire penetrameters. On the basis of tne enclosed evaluation, the staff has termined that the proposed alternative will provide     j an acceptable level of quality and safet Therefore, the alternative is authorized pursuant to 10 CFR 50.55a(a)(3(i).
Sincerely, Steve Dembeck, Section Chief, Section 2" Project Directorate IV & Decomm!:siofiing Division of Licensing Project Management Office of Nuclear Reactor Regulation
Sincerely, Steve Dembeck, Section Chief, Section 2" Project Directorate IV & Decomm!:siofiing Division of Licensing Project Management Office of Nuclear Reactor Regulation
                                                                                  /
/
Docket Nos. 50-361                         DISTRIBUTION:
KB,ro'/
and 50-36                         Docket                 KB,ro'/
Docket Nos. 50-361 DISTRIBUTION:
ckman, Region IV PUBLIC                 l,5mith, Region IV
and 50-36 Docket ckman, Region IV PUBLIC l,5mith, Region IV


==Enclosure:==
==Enclosure:==
Saf y Evaluation                 PDIV Reading         .RCN (SE)
Saf y Evaluation PDIV Reading
JZwolinski/SBlack f / DNaujock                        l cc w/ encl: See next page                   SRichards             WBateman                     !
.RCN (SE)
LRaghavan ,/
/
                                                                    /
JZwolinski/SBlack DNaujock f
EPeyton      /
cc w/ encl: See next page SRichards
ACRS       /
/
OGC       /
WBateman LRaghavan
,/
EPeyton
/
ACRS
/
OGC
/
GHill (2 '
GHill (2 '
Document Name: A:\MA3430SE.WPD . tW OFC       PDIV-2       PDIV-2           OdC NI             PDIV-2       /
Document Name: A:\\MA3430SE.WPD. tW OFC PDIV-2 PDIV-2 OdC NI PDIV-2
NAME       LRaghav       E               [8m/mlio!           SDembe l DATE       4 / h /99     4 / O /99     / 4 / 8 /99         4 //4/99 l
/
NAME LRaghav E
[8m/mlio!
SDembe l DATE 4 / h /99 4 / O /99
/
4 / 8 /99 4 //4/99 l
OFFICIAL RECORD COPY a
OFFICIAL RECORD COPY a


I                                                                                                       '
I p a sta 3".
p a sta 3".             4                             UNITED STATES g               .g           NUCLEAR REGULATORY COMMISSION o                 2                         WASHINGTON, D.C. 2065H001 4
4 UNITED STATES g
9 . . . . . ,o April 19, 1999 Mr. Harold B. Ray Executive Vice President Southern California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, California 92674-0128
.g NUCLEAR REGULATORY COMMISSION o
2 WASHINGTON, D.C. 2065H001 49.....,o April 19, 1999 Mr. Harold B. Ray Executive Vice President Southern California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, California 92674-0128


==SUBJECT:==
==SUBJECT:==
Line 78: Line 96:


==Dear Mr. Ray:==
==Dear Mr. Ray:==
 
By {{letter dated|date=August 26, 1998|text=letter dated August 26,1998}}, you submitted a request for relief from the American Society of Mechanical Eng'neers (ASME) Boiler and Pressure Vessel Code, Section XI requirements for certain inservice inspections at San Onofre Nuclear Generating Station, Units 2 and 3. In place of the ASME Code requirement for performing radiographic inservice inspections with plaque penetrameters, you proposed an alternative that would use wire penetrameters. On the basis of the enclosed evaluation,,the staff has determined that the proposed altemative will provide an acceptable level of quality and safety. Therefore, the alternative is authorized pursuant to 10 CFR 50.55a(a)(3(i).
By letter dated August 26,1998, you submitted a request for relief from the American Society of Mechanical Eng'neers (ASME) Boiler and Pressure Vessel Code, Section XI requirements for certain inservice inspections at San Onofre Nuclear Generating Station, Units 2 and 3. In place of the ASME Code requirement for performing radiographic inservice inspections with plaque penetrameters, you proposed an alternative that would use wire penetrameters. On the basis of the enclosed evaluation,,the staff has determined that the proposed altemative will provide an acceptable level of quality and safety. Therefore, the alternative is authorized pursuant to 10 CFR 50.55a(a)(3(i).
Sincerely, Steve Dembek, Chief, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 and 50-362
Sincerely, Steve Dembek, Chief, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 and 50-362


Line 86: Line 103:


San Onofre Nuclear Generating Station, Units 2 and 3 cc:
San Onofre Nuclear Generating Station, Units 2 and 3 cc:
Mr. R. W. Krieger, Vice President               Resident inspector / San Onofre NPS Southern Califomia Edison Company               c/o U.S. Nuclear Regulatory Commission San Onofre Nuclear Generating Station           Post Office Box 4329 P. O. Box 128                                   San Clemente, Califomia 92674 San Clemente, California 92674-0128 Mayor Chairman, Board of Supervisors                   City of San Clemente County of San Diego                               100 Avenida Presidio 1600 Pacific Highway, Room 335                   San Clemente, Califomia 92672 San Diego, California 92101 Mr. Dwight E. Nunn, Vice President Alan R. Watts, Esq.                             Southem California Edison Company Woodruff, Spradlin & Smart                       San Onofre Nuclear Generating Station 701 S. Parker St. No. 7000                       P.O. Box 128 Orange, Califomia 92668-4702                     San Clemente, California 92674-0128 Mr. Sherwin Harris Resource Project Manager Public Utilities Department City of Riverside 3900 Main Street                                                                       j Riverside, California 92522 1
Mr. R. W. Krieger, Vice President Resident inspector / San Onofre NPS Southern Califomia Edison Company c/o U.S. Nuclear Regulatory Commission San Onofre Nuclear Generating Station Post Office Box 4329 P. O. Box 128 San Clemente, Califomia 92674 San Clemente, California 92674-0128 Mayor Chairman, Board of Supervisors City of San Clemente County of San Diego 100 Avenida Presidio 1600 Pacific Highway, Room 335 San Clemente, Califomia 92672 San Diego, California 92101 Mr. Dwight E. Nunn, Vice President Alan R. Watts, Esq.
Regional Administrator, Region IV                                                       '
Southem California Edison Company Woodruff, Spradlin & Smart San Onofre Nuclear Generating Station 701 S. Parker St. No. 7000 P.O. Box 128 Orange, Califomia 92668-4702 San Clemente, California 92674-0128 Mr. Sherwin Harris Resource Project Manager Public Utilities Department City of Riverside 3900 Main Street j
U.S. Nuclear Regulatory Commission Harris Tower & Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064                                                             l 4
Riverside, California 92522 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 l
Mr. Michael Olson San Onofre Liaison                                                                     l San Diego Gas & Electric Company P.O. Box 1831 San Diego, Califomia 92112-4150 Mr. Steve Hsu Radiologic Health Branch State Department of Health Services Post Office Box 942732                                                                 i Sacramento, California 94234}}
4 Mr. Michael Olson San Onofre Liaison San Diego Gas & Electric Company P.O. Box 1831 San Diego, Califomia 92112-4150 Mr. Steve Hsu Radiologic Health Branch State Department of Health Services Post Office Box 942732 i
Sacramento, California 94234}}

Latest revision as of 14:41, 7 December 2024

Forwards SE Authorizing Licensee 980826 Request for Relief from ASME B&PV Code,Section XI Requirements for Certain ISIs at Plant,Units 2 & 3
ML20205Q617
Person / Time
Site: San Onofre  
Issue date: 04/19/1999
From: Stephen Dembek
NRC (Affiliation Not Assigned)
To: Ray H
SOUTHERN CALIFORNIA EDISON CO.
Shared Package
ML20205Q620 List:
References
TAC-MA3430, TAC-MA3431, NUDOCS 9904210329
Download: ML20205Q617 (4)


Text

n i

s April 19,1999 Mr. Harold B. Ray Executive Vice President Southem California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, California 92674-0128

SUBJECT:

EVALUATION OF WIRE PENETRAMETERS FOR INSERVICE INSPECTION RADIOGRAPHY, SAN ONOFRE NUCLEAR GENERATING STATIONS, UNITS 2 AND 3 (TAC NOS. MA3430 AND MA3431)

Dear Mr. Ray:

By letter dated August 26,1998, you submitted a request for relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI requirements for certain inservice inspections at San Onofre Nuclear Generating Station, Units 2 and 3. In place of the ASME Code requirement for performing radiographic inservice inspections with plaque penetrameters, you proposed an attemative that would use wire penetrameters. On the basis of the enclosed evaluation, the staff has determined that the proposed altemative will provide an acceptable level of quality and safety. Therefore, the attemative is authorized pursuant to 10 CFR 50.55a(a)(3(i).

Sincerely, ORIG. SIGNED BY Steve Dembek, Chief, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 DISTRIBUTION:

and 50-362 eDoduthe KBrockman, Region IV PUBLIC LSmith, Region IV

Enclosure:

Safety Evaluation PDIV Reading RCN (SE)

JZwolinski/SBlack DNaujock cc w/ encl: See next page SRichards WBateman LRaghavan EPeyton ACRS

  • For previous concurrences OGC see attached ORC GHill(2) f Document Name: A:\\MA3430SE.WPD l

OFC PDIV-2.

PDIV-2 OGC*

PDIV-2 W.om, s

NAME LRaghaven EPeytoh' RBachmann SDembek ff s U

DATE~

4 /l1 /99 4 / l b /99 4 /15 /99 4 /M/99 OFFICIAL RECORD COPY v neu

~

9904210329 990419 PDR ADOCK 05000361 P

PDR f

o l ~

Mr. Harold B. Ray Executive Vice President l

Southern California Edison Company l

San Onofre Nuclear Generating Station P. O. Box 128 l

San Clemente, California 92674-0128

SUBJECT:

EVALUATION OF WIRE PENETRAMETERS FO SERVICE INSPECTION RADIOGRAPHY, SAN ONOFRE NUCLEAR G RATING STATIONS, UNITS 2 AND 3 (TAC NOS. MA3430 AND MA3431)

Dear Mr. Ray:

By letter dated August 26,1998, you submitted a re est for relief from the American Society of Mechanical Engineers (ArNIE) Boiler and Pressur. Vessel Code,Section XI requirements for certain inservice inspections at San Onofre Nuc ar Generating Station, Units 2 and 3. In place of the ASME Code requirement for performi radiographic inservice inspections with plaque penetrameters, you proposed an alternativ at would use wire penetrameters. On the basis of tne enclosed evaluation, the staff has termined that the proposed alternative will provide j

an acceptable level of quality and safet Therefore, the alternative is authorized pursuant to 10 CFR 50.55a(a)(3(i).

Sincerely, Steve Dembeck, Section Chief, Section 2" Project Directorate IV & Decomm!:siofiing Division of Licensing Project Management Office of Nuclear Reactor Regulation

/

KB,ro'/

Docket Nos. 50-361 DISTRIBUTION:

and 50-36 Docket ckman, Region IV PUBLIC l,5mith, Region IV

Enclosure:

Saf y Evaluation PDIV Reading

.RCN (SE)

/

JZwolinski/SBlack DNaujock f

cc w/ encl: See next page SRichards

/

WBateman LRaghavan

,/

EPeyton

/

ACRS

/

OGC

/

GHill (2 '

Document Name: A:\\MA3430SE.WPD. tW OFC PDIV-2 PDIV-2 OdC NI PDIV-2

/

NAME LRaghav E

[8m/mlio!

SDembe l DATE 4 / h /99 4 / O /99

/

4 / 8 /99 4 //4/99 l

OFFICIAL RECORD COPY a

I p a sta 3".

4 UNITED STATES g

.g NUCLEAR REGULATORY COMMISSION o

2 WASHINGTON, D.C. 2065H001 49.....,o April 19, 1999 Mr. Harold B. Ray Executive Vice President Southern California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, California 92674-0128

SUBJECT:

EVALUATION OF WIRE PENETRAMETERS FOR INSERVICE INSPECTION RADIOGRAPHY, SAN ONOFRE NUCLEAR GENERATING STATIONS, UNITS 2 AND 3 (TAC NOS. MA3430 AND MA3431)

Dear Mr. Ray:

By letter dated August 26,1998, you submitted a request for relief from the American Society of Mechanical Eng'neers (ASME) Boiler and Pressure Vessel Code,Section XI requirements for certain inservice inspections at San Onofre Nuclear Generating Station, Units 2 and 3. In place of the ASME Code requirement for performing radiographic inservice inspections with plaque penetrameters, you proposed an alternative that would use wire penetrameters. On the basis of the enclosed evaluation,,the staff has determined that the proposed altemative will provide an acceptable level of quality and safety. Therefore, the alternative is authorized pursuant to 10 CFR 50.55a(a)(3(i).

Sincerely, Steve Dembek, Chief, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 and 50-362

Enclosure:

Safety Evaluation cc w/ encl: See next page

San Onofre Nuclear Generating Station, Units 2 and 3 cc:

Mr. R. W. Krieger, Vice President Resident inspector / San Onofre NPS Southern Califomia Edison Company c/o U.S. Nuclear Regulatory Commission San Onofre Nuclear Generating Station Post Office Box 4329 P. O. Box 128 San Clemente, Califomia 92674 San Clemente, California 92674-0128 Mayor Chairman, Board of Supervisors City of San Clemente County of San Diego 100 Avenida Presidio 1600 Pacific Highway, Room 335 San Clemente, Califomia 92672 San Diego, California 92101 Mr. Dwight E. Nunn, Vice President Alan R. Watts, Esq.

Southem California Edison Company Woodruff, Spradlin & Smart San Onofre Nuclear Generating Station 701 S. Parker St. No. 7000 P.O. Box 128 Orange, Califomia 92668-4702 San Clemente, California 92674-0128 Mr. Sherwin Harris Resource Project Manager Public Utilities Department City of Riverside 3900 Main Street j

Riverside, California 92522 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 l

4 Mr. Michael Olson San Onofre Liaison San Diego Gas & Electric Company P.O. Box 1831 San Diego, Califomia 92112-4150 Mr. Steve Hsu Radiologic Health Branch State Department of Health Services Post Office Box 942732 i

Sacramento, California 94234