05000416/FIN-2008003-03: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 1: Line 1:
{{finding
{{finding
| title = Ineffective Corrective Actions In Response To Plant Transients Resulting From Animal Intrusions
| title = Ineffective Corrective Actions in Response to Plant Transients Resulting from Animal Intrusions


| docket = 05000416
| docket = 05000416
Line 13: Line 13:
| identified by = Self-Revealing
| identified by = Self-Revealing
| Inspection procedure = IP 71153
| Inspection procedure = IP 71153
| Inspector = N O,'Keefe P, Elkmann R, Smith A, Barrett D, Bollock G, Guerra I, Anchond
| Inspector = N O, 'Keefep Elkmann, R Smith, A Barrett, D Bollock, G Guerra, I Anchondo
| CCA = P.5
| CCA = P.5
| INPO aspect = CL.1
| INPO aspect = CL.1

Revision as of 19:35, 20 February 2018

03
Site: Grand Gulf Entergy icon.png
Report IR 05000416/2008003 Section 4OA3
Date counted Jun 30, 2008 (2008Q2)
Type: Finding: Green
cornerstone Initiating Events
Identified by: Self-revealing
Inspection Procedure: IP 71153
Inspectors (proximate) N O
'Keefep Elkmann
R Smith
A Barrett
D Bollock
G Guerra
I Anchondo
CCA P.5, Operating Experience
INPO aspect CL.1
'