Regulatory Guide 5.34: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(9 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Adams
{{Adams
| number = ML13064A073
| number = ML003739949
| issue date = 06/30/1974
| issue date = 05/31/1984
| title = Nondestructive Assay for Plutonium in Scrap Material by Spontaneous Fission Detection
| title = (Task SG 046-4), Nondestructive Assay for Plutonium in Scrap Material by Spontaneous Fission Detection
| author name =  
| author name =  
| author affiliation = US Atomic Energy Commission (AEC)
| author affiliation = NRC/RES
| addressee name =  
| addressee name =  
| addressee affiliation =  
| addressee affiliation =  
Line 10: Line 10:
| license number =  
| license number =  
| contact person =  
| contact person =  
| document report number = RG-5.034
| document report number = RG-5.34, Rev 1
| document type = Regulatory Guide
| document type = Regulatory Guide
| page count = 11
| page count = 9
}}
}}
{{#Wiki_filter:1974.r U.S. ATOMIC ENERGY COMMISSION UE17R E*REGmULATORY GUIDE"DIRECTORATE OF REGULATORY STANDARDSREGULATORY GUIDE 5.34NONDESTRUCTIVE ASSAY FOR PLUTONIUM IN SCRAP MATERIALBY SPONTANEOUS FISSION DETECTION
{{#Wiki_filter:Revision 1"
                          U.S. NUCLEAR REGULATORY COMMISSION                                                                       May 1984
                    0
                    SREGULATORY
                        OFFICE OF NUCLEAR REGULATORY RESEARCH
                                                                                                          GUIDE
                                                        REGULATORY GUIDE 5.34 (Task SG 046-4)
                    NONDESTRUCTIVE ASSAY FOR PLUTONIUM IN SCRAP MATERIAL
                                          BY SPONTANEOUS FISSION DETECTION


==A. INTRODUCTION==
==A. INTRODUCTION==
Section 70.51, "Material Balance, Inventory, and Records Requirements," of10 CFR Part 70, "Special Nuclear Material," requires certain licensees authorized topossess at any one time more than one effective kilogram of plutonium to establishand maintain a system of control and accountability such that the limit of error(LE) associated with the material unaccounted for (MUF), ascertained as a resultof a measured material balance, meets minimum standards.Included in a typical material balance are containers of inhomogeneousscrap material that are not amenable to assay by the traditional method ofsampling and chemical analysis. With proper controls, the nondestructive assay(NDA) technique of spontaneous fission detection (SFD) is an acceptable methodfor the assay of plutonium in containers of bulk scrap material. The use of SFDthus facilitates the preparation of a complete plant material balance whoseLEMUF meets established requirements.This guide describes procedures acceptable to the Regulatory staff forapplication of the technique of spontaneous fission detection for the nondestruc-tive assay of plutonium in scrap.
standard error. Unlike the major quantity of material flowing through the process, scrap is typically Section 70.51, "Material Balance, Inventory, and                   inhomogeneous and difficult to sample. Therefore, a Records Requirements," of 10 CFR Part 70, "Domestic                    separate assay of the entire content of each container of Licensing of Special Nuclear Material," requires certain               scrap material is a more reliable method of scrap account licensees authorized to possess at any one time more                   ability. NDA is a method for assaying the entire content than one effective kilogram of special nuclear material                of every container of scrap.
 
to establish and maintain a system of control and accountability so that the standard error (estimator)                       The term "scrap" refers to material that is generated associated with the inventory difference (SEID),                       from the main process stream because of the ineffi obtained as a result of a measured material balance,                     ciency of the process. Scrap material is generally meets minimum standards. This guide is intended for                    economically recoverable. Scrap, therefore, consists of those licensees who possess plutonium scrap materials                  rejected or contaminated process material such as pellet and who are also subjected to the requirements of                      grinder sludge, sweepings from gloveboxes, dried filter
  § 70.51 of 10 CFR Part 70.                                            sludge, and rejected powder and pellets. Scrap is generally distinguished from "waste" by the density or concentra Included in a typical material balance are containers               tion of heavy elements in the two materials, but it is of inhomogeneous scrap material that are not amenable                   the recovery cost (per mass unit of special nuclear to assay by the traditional method of sampling and                       material) that determines whether a material is "scrap"
chemical analysis. With proper controls, the non                        or "waste."      The concentration of uranium and pluto destructive assay (NDA) technique of spontaneous                         nium in scrap is approximately the same as it is in fission detection is one acceptable method for the assay                 process material, i.e., 85-90 percent (uranium + pluto of plutonium in containers of bulk scrap material. The                   nium) by weight. However, on occasion the fraction in use of spontaneous fission detection thus facilitates the               both process and scrap material can be less than 25 preparation of a complete plant material balance whose                  percent. Plutonium in fast reactor scrap material is SEID meets established requirements.                                     15-20 percent by weight and in thermal reactor recycle material, 2-9 percent by weight. The main difference This guide describes procedures acceptable to the                   between scrap and process material is that scrap is NRC staff for applying the NDA technique of                             contaminated and inhomogeneous. Waste, on the other spontaneous fission detection to plutonium in scrap.                    hand, contains a low concentration of uranium and plutonium, ie., a few percent or less (uranium + pluto Any guidance in this document related to informa                    nium) by weight. However, the recovery of combustible tion collection activities has been cleared under OMB                    waste by incineration may produce ash that is high in Clearance No. 3150-0009.                                                uranium and plutonium concentrations. Such incinerator ash is also considered "scrap" in this guide. However, it


==B. DISCUSSION==
==B. DISCUSSION==
Plutonium in scrap material can contribute significantly to the materialunaccounted for (MUF) and to its associated limit of error (LEMUF). Unlike themajor quantity of material flowing through a process, scrap *is typicallyUSAEC REGULATORY GUIDES Copies of published guides may be obtained by request indicating the divisionsdesired to the US. Atomic Energy Commission. Wasshington, D.C. 20545,lioulato v Gu-des ... ,s.ed to describe end make availeble to the public Attention: Director of Regulatory Standards. Comiments and suggestions for,iethodt a sceptablit to thn AEC Reguletor,/ staff of implementing specific parts of irnprovem'antm in the guides ere encourad and should be sent to the Secretarytire C1nn nont's to delineate techniques used by the staff in of the Commission. US. Atomic Energy Comenission, Washington, D.C. 20545,-iuJt.01P specific problems or postulated accidents, or to provide guidance to Attention: Chief. Public ProcmedingStaff.lpolicans Regulatory Guides sm not sutStitutes for regulations and complinaew-th them i* not required. Methods ernd solutions different from those eat out in The guides are issued in the following ten broad divisions:the guldes will be acceptable if they prosvide a basis for the findings requisite tothe issuance or Wcninuance of a permlt or license by the Cornrmission. 1. Power Reactors 6. Product2. Resetrch ancd Test RI.tors 7. Trarnportation3. Fuels and Materials Facilities 8. Occupational HealthPublished guides will be revised periodically, as appropriate. to accommodate 4. Environmental and Siting 9. Antitrust Reviewcomirnts and to reflect new informttion or experience. 5. Materials and Plant Protuction 10. Generel inhomogeneous and difficult to sample. Therefore, a separate assay of theentire content of each container of scrap material is the only reliable methodof scrap accountability. Nondestructive assay (NDA) is a method for assayingthe entire content of every container of scrap.The term "scrap" refers here to material that is generated incident to themain process stream due to the inefficiency of the process. Scrap material isgenerally economically recoverable. Scrap therefore consists of reject orcontaminated process material such as pellet grinder sludge, sweepings from aglovebox, dried filter sludge, and reject powder and pellets. Scrap is distinguishedfrom "waste" by the density or concentration of heavy elements in the two materials.The concentration of uranium and plutonium in scrap is approximately the same asit is in process material, i.e., 85-90% (U + Pu) by weight. Plutonium in fastreactor scrap material is 15-20% by weight and in thermal reactor recycle material2-9% by weight. The main difference between scrap and process material is thatscrap is contaminated and inhomogeneous. Waste, on the other hand, contains alow concentration of plutonium and uranium, i.e., a few percent or less (U + Pu)hy weight. However, the recovery of combustible waste by incineration mayproduce ash that is high in uranium and plutonium concentrations. Such incin-erator ash is also considered "scrap" in this Ruide.Nondestructive assay for plutonium can be accomplished primarily by thepassive methods of gamma ray spectrometry, calorimetry, and spontaneous fissiondetection. Regulatory Guide 5.111 provides a framework for the utilization ofthese NDA methods.Gamma ray spectrometry of scrap consisting of dense materials can beunreliable because of the attenuation of gamma rays. Gamma ray spectrometry ismost applicable to waste assay.Calorimetry is an accurate method of plutonium assay when there is anaccurate knowledge of the relative abundance of each plutonium isotope andamericium-241. Scrap may contain a mixture of materials of different radio-nuclidic compositions, especially different americium-241 concentrations,necessitating the measurement of the average radionuclidic composition. Theaverage radionuclidic abundances can only be accurately measured when the scrap5.34-2 is reasonably homogeneous. When the radionuclidic abundances can be accurately2measured or controlled, calorimetry can be applied to scrap assay. However,calorimetry is time-consuming for heterogeneous materials of high heat capacityand may not be a practical method for the routine assay of large numbers ofcontainers.Spontaneous fission detection (SFD) is the most practicable and generallyapplicable NDA technique for the assay of plutonium in scrap material. Spontaneousfission radiations are sufficiently penetrating to provide a representativesignal from all the plutonium within a container. The plutonium isotopic compositionmust be known for SFD assay, but the accuracy of SFD is not as dependent on theaccuracy of analysis for the minor plutonium isotopes as is that of calorimetry.Nor is SFD sensitive to americium-241 ingrowth. The quantity of scrap materialon inventory when a material balance is computed can be reduced through goodmanagement, and the scrap remaining on inventory can be assayed by SFD to meetthe overall plant MUF and LEKUF constraints required by paragraph (e)(5) ofSection 70.51 of 10 CFR Part 70.This guide gives recommendations useful for the SFD assay of containers,each containing a few liters of scrap and having contents ranging from a fewgrams to a few hundred grams of plutonium or approximately 50 grams of effectiveplutonium-240.*: Containers with a larger plutonium content, i.e., on the order,-f 500 grams of plutonium or more, give a spontaneous fission response that isiifficult to interpret due to high countina rates and noscihlP neutron multi-Dlication. A large auantitv of plutonium can he a.sayed hv SF1) by subdividingthe scrap into smaller amounts, or the items may be more amenable to nondestructiveassay bv calorimetry.*The effective plutonium-240 mass is a weighted average of the mass of each ofthe plutonium isotopes. The weighting is equal to the spontaneous fissionneutron yield of each isotope relative to that of Pu-240. Since only the even-numbered isotopes have significint spontaneous fission rates, the effective Pu-240mass is given approximately by:M(240)eff = M(240) + 1.64M(242) + 2.66M(238)where M is the mass of the. isotope indicated in parentheses. The coefficients in thisequation are only known to approximately +5%.5.34-3
should be noted that ash may be more homogeneous in Plutonium in scrap material can contribute signif                       
* The substantial number of changes in this revision has made icantly to the inventory difference and its associated                 it impractical to indicate the changes with lines in the margin.
 
USNRC REGULATORY GUIDES                                 Comments should be sent to the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Regulatory Guides are issued to describe and make available to the       Attention: Docketing and Service Branch.
 
public methods acceptable to the NRC staff of implementing specific parts of the Commission's regulations, to delineate tech-      The guides are issued in the following ten broad divisions:
niques used by the staff in evaluating specific problems or postu lated accidents or to provide guidance to applicants. Regulatory        1. Power Reactors                  6. Products Guides are no? substitutes for regulations, and compliance with          2.  Research and Test Reactors      7. Transportation them is not required. Methods and solutions different from those set    3. Fuels and Materials Facilities  8. Occupational Health out in the guides will be acceptable if they provide a basis for the     4. Environmental and Siting         9. Antitrust and Financial Review findings requisite to the issuance or continuance of a permit or         5. Materials and Plant Protection 10. General license by the Commission.
 
Copies of issued guides may be purchased at the current Government This guide was issued after consideration of comments received from     Printing Office price. A subscription service for future guides in spe the public. Comments and suggestions for improvements in these          cific divisions is available through the Government Printing Office.
 
guides are encouraged at all times, and guides will be revised, as      Information on the subscription service and current GPO prices may appropriate, to accommodate comments and to reflect new Informa-         be obtained by writing the U.S. Nuclear Regulatory Commission, tion or experience.                                                     Washington, D.C. 20555, Attention: Publications Sales Manager.
 
its characteristics compared to most scrap and may,                   This guide gives recommendations useful for the assay therefore, be accountable using sampling and chemical            by spontaneous fission detection of containers, each analysis methods.                                                containing a few liters of scrap and having contents ranging from a few grams to 10 kilograms of plutonium or up to approximately 2 kilograms of effective
                                                                                                                                240
                                                                                                                                    Pu 2 NDA of plutonium can be accomplished primarily by the passive methods of gamma ray spectrometry,                    (see Ref. 7). Containers with a significant plutonium calorimetry, and spontaneous fission detection. Active            content (i.e., 50 grams or more) give a spontaneous neutron methods using total count rates or delayed                fission response that must be corrected for the effects neutron detection can also be used in scrap assay                of neutron multiplication (Refs. 8, 9). Scrap materials measurements. Regulatory Guide 5.11, "Nondestructive              that have large loadings of plutonium in addition to Assay of Special Nuclear Material Contained in Scrap              fluorine, oxygen, or other alpha/neutron-producing and Waste," provides        a framework for the use of these    elements are difficult to measure and correct for multi
                  1 NDA methods.                                                     plication effects because of the large random neutron flux from the (ct,n) reactions in the matrix materials.
 
The NDA of dense scrap materials using gamma ray              These samples should be segregated into smaller quanti spectroscopy can be unreliable because of severe gamma            ties for measurements. In general, a large quantity of ray attenuation. However, the isotopic composition of              plutonium can be assayed by spontaneous fission detec plutonium in scrap materials, with the exception of                tion by subdividing the scrap into smaller amounts, or
242pu, can be obtained quite reliably using high-resolution        the items may be more amenable to assay by calorim gamma ray spectrometry measurements (Ref. 1).                     etry.


==C. REGULATORY POSITION==
==C. REGULATORY POSITION==
The method of spontaneous fission detection (SFD) for the nondestructiveassay for plutonium in bulk inhomogeneous scrap material should include: (1)discrimination of spontaneous fission radiations from random background bycoincidence techniques and (2) measurement of the relative plutonium isotopiccomposition of the scrap by an independent measurement technique. An acceptableSFD method of plutonium assay is described below:1. Spontaneous Fission Detection Systema. Detectors. Instruments based on moderated thermal neutron detectors,i.e., neutron well coincidence counters,4,5 are recommended for applications inwhich the gross neutron detection rate does not exceed 2 x 104 neutrons/sec.The( dead time inherent in these slow coincidence systems can be reduced by employinga shift-register coincidence circuit. If the gross neutron detection rate isdue primarily to random background and exceeds 2 x 104 neutrons/sec, then afast neutron detection, single coincidence system can be used, provided thatadequate corrections can be made for matrix effects. Matrix effects are moresevere in fast neutron detection systems, as shown in Table I.b. Detection Chamber. The chamber should permit reproducible positioningof standard-sized containers in the location of maximum spatial response uniformity.c. Fission Source. A spontaneous fission source with a neutron intensitycomparable to the intensity of the largest plutonium mass to be assayed should7be used for making matrix corrections, using the source addition technique. Ananogram of Cf-252 is approximately equivalent to a gram of effective Pu-240.d. Readout. Readout should allow computation of the accidental to realcoincidence ratio in addition to the net real coincidence rate. Live timereadout or a means of computing the dead time should also be provided:e. Performance Specifications. The performance of a SFD instrumentshould be evaluated according its stability, uniformity of spatial response, andinsensitivity to matrix effects. Therefore, information should be obtainedregarding:(i) The precision of the coincidence response as a function of thereal coincidence counting rate and the accidental to real coincidence ratio.Extremes in the background or accidental coincidence rate can be simulated byusing a source of random neutrons (nonfission).5.34-4 TABLE IMATRIX MATERIAL EFFECTS ON NEUTRON ASSAYNeutron Detection Efficiency8Lo1'4-Matrix Material(in "ý4 liter can)Empty CanCarbon PelletsMetalSlag-CrucibleConcreteString FiltersCH2 (p=0.65 g/cc)CH2 (p=O. 12 g/cc)CH2 (P=0.27 g/cc)H 20 (p=l.O0 g/cc)Mass(kg)1.893.601.803.240.600.270.430.973.621.031.041.031.051.071.061.091.190.983He Detector;Thermal1.004He Detector,Fast1.000.830.940.840.950.960.920.710.36ZnS Detector,1.000.750.910.790.860.920.900.670.35Coincidenceifficiency,He Detector,Thermal1.001.051.091.081.101.171.111.191.360.98Correcteda,7CoincidenceEfficiencyHe Detector,Thermal1.000.971.021.011.021.051.000.981.040.96aCorrected using the sourceaddition techniqu (ii) Uniformity of spatial response. Graphs should be obtained onthe relative coincidence response from a point source of fission radiation as afunction of position in the counting chamber.(iii) Sensitivity of matrix interference. A table of the relativecoincidence response from a point source of fission radiation as a function ofthe composition of the matrix material surrounding the point source should beobtained. Included in the matrix should be materials considered representativeof commmon scrap materials. Table I is an example of such a tabulation of therelative response for a wide range of materials.This information should be used for evaluating the expected instrument per-formance and estimating errors. The above performance information can be requestedfrom the instrument suppliers during instrument selection and should be acquiredduring preoperational instrument testing.2. AnalystA highly trained individual should oversee SFD assay for plutonium and shouldhave primary responsibility for instrument specification, preoperational instrumenttesting, standards and calibration, writing an operation manual, measurementcontrol, and error analysis. Experience or training equivalent to a bachelorsdegree in science or engineering from an accredited college or university and alaboratory course in radiation measurement should be the minimum qualifications ofthe SFD analyst. The SFD analyst should review SFD operation at least weekly andshould authorize all changes in SFD operation.3. Containers and PackagingA single type of container should be used for packaging all scrap in eachcategory, as discussed below. A recommended uniform container that would facilitateaccurate measurement and would standardize this segment of instrument design isa thin-walled metal (steel) can with an inside diameter of approximately 10 cmor less.4. Reduction of Error Due to Material VariabilityThe SFD response variation due to material variability in scrap should bereduced by: (1) segregation-of scrap into categories that are independentlycalibrated, (2) correcting for matrix effects using the source addition technique,7or (3) applying both categorization and the source addition technique. qategorizationshould be used if the SFD method is more sensitive to the material variabilityfrom scrap type to scrap type than to the material variability within a scrap5.34-6 type. Application of the source addition technique reduces the sensitivityto material variability and may allow the majority of scrap types to be assayedunder a single calibration. Material characteristics that should be consideredin selecting categories include:a. Plutonium Isotopic Compositionb. Uranium/Plutionium Ratioc. Containerization and Packagingd. Abundance of High-Yield alpha-neutron Material, .i.e., low-atomic-number impuritiese. Plutonium Contentf. Density (both average density and local density extremes should beconsidered)g. Matrix Composition5. CalibrationA guideto calibration for nondestructive assay is presently under developmentby Task Force 8.3 of the N15 committee of the American National Standards Institute*and will include details on calibration standards, calibration procedures, curvefitting, and error analysis. Guidelines relevant to SFD are given below.a. A minimum of four calibration standards of the same isotopic compositionas the unknowns should be used for calibration. If practicable, a calibrationcurve should be generated for each isotopic blend of plutonium. When plutonium ofdifferent isotopic composition is assayed using a single calibration, the effecton the SFD response of isotopic composition should be determined over the operatingranges by measuring standards of differing plutonium isotopic compositions.The use of the effective Pu-240 concept can lead to error because of the uncertaintyin the spontaneous fission half-lives, as shown in Table II, and the variation inresponse with isotopic composition.b. Calibration standards should be fabricated from material having aplutonium content determined by a technique traceable to or calibrated withNational Bureau of Standards standard reference material. Well-characterizedhomogeneous material similar to the process material from which the scrap isgenerated can be used to obtain calibration standards.c. Fabrication of calibration standards that are truly representative ofthe unknowns is difficult for scrap assay. To measure the reliability of thecalibration based on. the fabricated standards discussed above, and to improvethis calibration, unknowns that have been assayed by SFD should periodically be*When copies become available, they may be obtained from the American NationalStandards Institute, Inc., 1430 Broadway, New York, New York 10018.5.34-7 TABLE IIEFFECTIVE PLUTONIUM-240 ABUNDANCE AND UNCERTAINTYCORRESPONDING TO DIFFERENT BURNUP CATEGORIESaApproximate Abundance (%)BUXl IUP(N-dt) Pu-238 Pu-239 Pu-240 Pu-241 Pu-242 Pu-240eff8,000-10,000 0.10 87 10 2.5 0.3 10.75+/-0.03(0.3%)16,000-18,000 0.25 75 18 4.5 1.0 20.30+/-0.08(0.4%)25,000-27,000 1.0 58 25 9.0 7.0 39.14+/-0.50(1.3%)38,000-40,000 2.0 45 27 15.0 12.0 52.00+/-0.87(1.7%)aComputed using the following coefficients for Pu-238 and Pu-242 in theequation for Pu-240 effective:M(240)eff = M(240) + 1.64+/-0.07 M(242) + 2.66+/-0.19 M(238)The uncertainties in the cn'.:icients and in the effective Pu-240abundances in the table are from tie reportea standard deviations inthe most reliable data available.-5.34-8 selected for assay by an independent more accurate technique. Calorimetry2 canbe used to assay a random selection of scrap in containers and provide reliable datathat should be fed back into the calibration fitting procedure to improve SFDcalibration. The original calibration standards should be retained as workingstandards.6. Measurement ControlFor proper measurement control, a "dummy" item should be assayed on eachday of scrap assay as a background measurement. Also, control (or working)standards should be assayed each day scrap is assayed for normalization and toassure reliable operation.The source addition technique7 is recommended for correcting the SFD responsefor each assay. If not, used routinely, the source addition technique should beapplied to a random selection of items but in no case should be used less frequentlythan daily. The results of random applications of the source addition techniquecan be used in two ways:a. As an average correction factor to be applied to a group of items, andb. As a check on the item being assayed to verify that it is similar tothe standards used in calibration and that no additional matrix effects arepresent, i.e., purely as a qualitative assurance that the calibration is valid.7. Error AnalysisThe sources of error in SFD are discussed in Regulatory Guide 5.11.1Analysis of the error in the calibration is discussed in the literature4,9and in the ANSI guide on calibration now under development. In addition to thecalibration error there are errors due to the measurement process and due tovariability in material composition.The error due to the measurement process, i.e., the measurement-to-measurementerror, accounts for most of the random error in NDA. At least fifteen unknownsselected at random should be repeatedly assayed to estimate the random error.Repeated measurements should be made under as many different conditions as areexperienced in normal operation, e.g., different times of day, different operators,different ambient conditions. The standard deviation in the distribution ofdifferences in replicate results should be used in constructing a 95% confidenceinterval. The mean difference in replicate results has an expected value of zero.Corrections for significant drift in the instrumentperformance should be made basedon data from daily assay of control standards, i.e., the measurement control program.5.34-9 The error due to material variability, i.e., the item-to-item error, is theinalor source of bias and systematic error in NDA. If proper calibration standardsaiid a proper calibration relationship are used, the calibrating error should be areliableestimate of the systematic error. To test these assumptions, and todetermine the bias, SFD assay results on a random selection of unknowns should becompared with assays on the same items by an independent more accurate technique,as discussed in 4(c). Calorimetry is not sensitive to the mf1ajority of interferencesthat cause error due to material variability in SFD and is practical for thisapplication because it is nondestructive. An alternative method for verifying SFDassay .s to sample the scrap extensively and to perform chemical analyses for theplutonium concentrations in these samples.The mean difference in comparative assays should be used as the bias forcorrecting SFD assay results. The bias correction should be made if the meandifference is greater than 0.1 times the standard deviation in the mean difference.The standard deviation in the bias (mean difference) is a systematic error thatshould be used in constructing a 95% confidence interval. (There will always bea potential bias and systematic error in the technique used to verify SFD. Thesystematic error should be known and should be insignificant compared to systematicerror in SFD for the technique to be viable for verifying SFD assay results.)Comparisons of SFD with a more accurate assay method should be made on at leasttwo unknowns a week to determine bias and systematic error. Data may be pooled andused to improve the calibration although no data should be older than one year.REFERENCES1. Regulatory Guide 5.11, "Nondestructive Assay of Special Nuclear MaterialContained in Scrap and Waste."2. Regulatory Guide 5.35, "Calorimetric Assay of Plutonium."3. C. Weitkamp, "Nuclear Data-for Safeguards: Can Better Data Improve PresentTechniques?" Symposium on Practical Applications of R&D in the Field of.Safeguards, Rome, March 1974, and J. D. Hastings and W. W. Strohm,J. Inorg. Nucl. Chem., Vol. 34, pp. 25-28, 1972.4. R. Sher, "Operating Characteristics of Neutron Well Coincidence Counters,"BNL- 50332, January 1972.5. J.' E. Foley, "Neutron Coincidence Counters in Nuclear Applications," IEEETransactions Vol. NS-19, No. 3, pp. 453-456, June 1972.5.34-10 6. K. Bbhnel, "Neutron Coincidence Counting with Overlapping Cycles," October1972, Gesellschaft fUr Kernforschung mbH. 75 Karlsruhe, P. 0. Box 3640,Germany, or L. V. East and J. E. Foley, "An Improved Thermal-NeutronCoincidence Technique," LA-5197, 1972.7. H. 0. Menlove and R. B. Walton, "47r Coincidence Unit for One-Gallon Cans andSmaller Samples," LA-4457-MS, 1970.8. 11. 0. Menlove, "Matrix Material Effects on Fission-Neutron Counting UsingThermal- and Fast-Neutron Detectors," LA-4994-PR, p. 4, 1972.9. J. Jaech, "Statistical Methods in Nuclear Material Control," TID-26298,Section 3.3.8, 1974.5.34-11}}
Calorimetry is an accurate method of plutonium assay when there is an accurate knowledge of the                      The spontaneous fission detection method for the relative  abundance of each plutonium isotope and                NDA of plutonium in bulk inhomogeneous scrap material
24 tAm. Scrap may contain a mixture of materials of              should include (1) discrimination of spontaneous fission different radionuclide compositions, especially different        radiations from random background by coincidence
241Am concentrations, thereby necessitating the measure          techniques and (2) measurement of the relative pluto ment of the average radionuclide composition. The                nium isotopic composition of the scrap. An acceptable average radionuclide abundances can be accurately meas            spontaneous fission detection method of plutonium ured only when the scrap is reasonably homogeneous.              assay is described below.
 
When the radionuclide abundances can be accurately measured or controlled, calorimetry can be applied to            1. SPONTANEOUS FISSION DETECTION SYSTEM
scrap assay (Ref. 2). However, calorimetry is time con suming for materials of high heat capacity and may                1.1    Detectors not be a practical method for the routine assay of large numbers of containers.                                                Instruments based on moderated thermal neutron detectors, i.e., neutron well coincidence counters, are Spontaneous fission detection is a practical NDA              recommended for applications in which the gross technique for the assay of plutonium in scrap material.          neutron detection rate does not exceed 2 x 105 The assay method involves the passive counting of                neutrons/sec. The dead time inherent in these slow spontaneous fission neutrons emitted primarily from the          coincidence systems can be reduced by employing a fission of 240 Pu. Neutron coincidence counters are used         shift-register coincidence circuit. If the gross neutron to detect these time-correlated neutrons. The theory and          detection rate is Lprimarily due to random background practice of neutron coincidence counting for plutonium           and exceeds 2 x 10 neutrons/sec, a fast-neutron-detection, assay are discussed thoroughly in References 3 through 6.        single-coincidence system can be used, provided adequate Spontaneous fission neutrons are sufficiently penetrating        corrections can be made for matrix effects. Matrix to provide a representative signal from all the plutonium        effects are more severe in fast-neutron-detection systems, within a container. Since the neutron coincidence signal          as shown in Table 1.
 
is dependent on both the quantity and relative abundance
        8      240
of 2 3 Pu,          pu, and 242pu, the plutonium isotopic
                                                                        2 composition must be known for assay of total plutonium                  The effective 24 0 Pu mass is a weighted average of the mass by spontaneous fission detection. The quantity of scrap            of each of the plutonium isotopes. The weighting is equal to the spontaneous
                                                                          0
                                                                                  fission neutron yield of each isotope relative to that material on inventory when a material balance is com              of 2 4Pu. Since only the even-numbered isotopes have significant puted can be reduced through good management, and                spontaneous fission rates, the effective 240 Pu mass is given approxi mately by:
  the scrap remaining on inventory can be assayed by M(240)eff = M(240) + (1.64    + 0.07)M(242)
  spontaneous fission detection to meet the overall plant inventory difference (ID) and SEID constraints required                              + (2.66 +/- 0.19)M(238)
  by paragraph 70.5 1(e)(5) of 10 CFR Part 70.                     where M is the mass of the isotope indicated in parentheses. The uncertainties in the coefficients and in the effective 240 Pu abun dances in the table are from the reported standard deviations in the most reliable data available (Ref. 7). The mathematical procedure for converting from M(240)eff to M(total Pu) is presented in the
        1Revision I to this guide was issued in April 1984.         appendix to this guide together with a sample calculation.
 
5.34-2
 
TABLE 1 MATRIX MATERIAL EFFECTS ON NEUTRON ASSAY
                                                                                                                Correcteda (Ref. 10)
                                Neutron Detection Efficiency (Ref. 11)                          Coincidence  Coincidence Efficiency,    Efficiency,
                                    3                4                                        3 Matrix Material            Mass      He Detector,     He Detector,       ZnS Detector,       He Detector, 3He Detector, (in %4-liter can)          (kg)      Thermal              Fast                  Fast            Thermal        Thermal Empty Can                -              1.00              1.00                  1.00                1.00          1.00
Carbon Pellets          1.89          1.03              -                    -                    1.05          0.97 Metal                    3.60          1.04              0.83                0.75                1.09          1.02 Slag-Crucible            1.80          1.03              0.94                0.91                1.08          1.01 Concrete                3.24          1.05              0.84                0.79                1.10          1.02 String Filters          0.60          1.07              0.95                0.86                1.17          1.05 CH 2 (p=0. 6 5 g/cc)     0.27          1.06              0.96                  0.92                1.11          1.00
CH 2 (p=0.1   2 g/cc)   0.43          1.09              0.92                  0.90                1.19          0.98 CH 2 (p=0. 2 7 g/cc)     0.97          1.19              0.71                  0.67                1.36          0.04 H120 (p=l.00 g/cc)      3.62          0.98              0.36                  0.35                0.98          0.96 aCorrected using the source addition technique (see Ref. 7).
1.2 Detection Chamber                                            uniformity of spatial response, and insensitivity        to matrix effects. Therefore, information should             be The chamber should permit reproducible positioning            obtained regarding:
of standard-sized containers in the location of maximum spatial response uniformity.                                           1. The precision of the coincidence response as a function of the real-coincidence counting rate and the
1.3  Fission Source                                              accidental-to-real-coincidence ratio. Extremes in the back ground or accidental-coincidence rate can be simulated A spontaneous fission source with a neutron intensity        by using a source of random neutrons (nonfission).
comparable to the intensity of the largest plutonium mass to be assayed should be used for making matrix                  2. The uniformity of spatial response. Graphs should corrections using the source addition technique (Ref. 10).        be obtained on the relative coincidence response to a A nanogram of 252Ca is approximately equivalent to a              small fission neutron source as a function of position in gram of effective 2 40 Pu.                                        the counting chamber.
 
1.4  Readout                                                        3. The sensitivity of matrix interference. A table of the relative coincidence response to a small fission Readout should allow computation of the accidental            neutron source as a function of the composition of the to-real-coincidence ratio in addition to the net real              matrix material surrounding the point source should be coincidence rate. Live-time readout or a means of                  obtained. Included in the matrix should be materials computing the dead time should also be provided.                  considered representative of common scrap materials.
 
Table 1 is an example of such a tabulation of the
1.5  Perfonnance Specifications                                  relative response for a wide range of materials.
 
The performance of a spontaneous fission detection                This information should be used for evaluating the instrument should be evaluated according to its stability,         expected instrument performance and for estimating
                                                            5.34-3
 
errors. The above performance information can be                    6. Density (both average density and local density requested from the instrument suppliers during instru            extremes should be considered), and
                                                                                                                                  3/4'
ment selection and should be verified during preopera tional instrument testing.                                          7. Matrix composition.
 
2. ANALYST                                                     
 
===5. CALIBRATION===
    A trained individual should oversee spontaneous                Guidelines for calibration and measurement control fission detection assay of plutonium and should have            for NDA are available in Regulatory Guide 5.53, "Qualifi primary responsibility for instrument specification,            cation, Calibration, and Error Estimation Methods for preoperational instrument testing, standards and calibra        Nondestructive Assay," which endorses ANSI N15.20
tion, an operation manual, measurement control, and              1975, "Guide to Calibrating Nondestructive Assay error analysis. Experience or training equivalent to a          Systems." 3 The guide and standard include details on bachelor's degree in science or engineering from an              calibration standards, calibration procedures, curve fitting, accredited college or university and a laboratory course        and error analysis. Guidelines relevant to spontaneous in radiation measurement should be the minimum                  fission detection are given below.
 
qualifications of the analyst. The spontaneous fission detection analyst should frequently review the sponta                Calibration can be used for either a single isotopic neous fission detection operation and should authorize          composition or variable isotopic mixtures. In the former any changes in the operation.                                    case, the resulting calibration curve will be used to convert "net real-coincidence count" to "grams pluto
3. CONTAINERS AND PACKAGING                                      nium." In the latter case, the conversion is from "net real-coincidence count" to "effective grams 24°pu."
    A single type of container should be used for              The mathematical procedure for converting from packaging all scrap in each category. A uniform con              effective grams 2 4 0 pu, M( 24 0 )eff, to total grams pluto tainer that would facilitate accurate measurement and            nium, M(total Pu), is presented in the appendix to this would standardize this segment of instrument design,            guide together with a sample calculation.
 
e.g., a thin-walled metal (steel) can with an inside diameter between 10 and 35 cm, is recommended. For                    A minimum of four calibration standards with further guidance on container standardization in NDA            isotopic compositions similar to those of the unknowns measurements, see Reference 12.                                  should be used for calibration. If practicable, a calibra tion curve should be generated for each isotopic blend
4.    REDUCING ERROR DUE TO MATERIAL                            of plutonium. When plutonium of different isotopic VARIABILITY                                                composition is assayed using a single calibration, the effect of isotopic composition on the spontaneous The variation in spontaneous fission detection              fission detection response should be determined over the response due to material variability in scrap should be           operating ranges by measuring standards of different reduced by (1) segregating scrap into categories that are        plutonium isotopic compositions. This is necessary independently      calibrated,  (2) correcting for matrix       because the use of the effective 2 40 pu concept can lead effects using the source addition technique (Ref. 10), or        to error owing to the uncertainty in the spontaneous
(3) applying both the categorization and the source              fission half-lives and the variation in response with addition technique. Categorization should be used if the         isotopic composition. Table 2 illustrates the uncertainty spontaneous fission detection method is more sensitive          in effective 2 40 Pu abundance with different isotopic to the material variability from scrap type to scrap type        compositions (Ref. 13).
than to the material variability within a scrap type.
 
Application of the source addition technique reduces the            Calibration standards should be fabricated from sensitivity to material variability and may allow the           material having a plutonium content determined by a majority of scrap types to be assayed under a single            technique traceable to or calibrated with the standard calibration. Material characteristics that should be             reference material of the National Bureau of Standards.
 
considered in selecting categories include:                      Well-characterized homogeneous material similar to the process material from which the scrap is generated can
      1. Plutonium isotopic composition and content,             be used to obtain calibration standards.
 
2. Uranium/plutonium ratio,                                     Fabrication of calibration standards that are truly representative of the unknowns is impossible for scrap
      3. Types of container and packaging,                        assay. To measure the reliability of the calibration based on the fabricated standards discussed above and to
      4. Abundance of high-yield alpha/neutron    material,      improve this calibration, unknowns that have been i.e., low-atomic-number impurities,                                  3 Copies of this standard may be obtained from the American National Standards Institute, Inc., 1430 Broadway, New York,
      5. Size  and distribution  of materials in packages,      New York 10018.
 
5.34-4
 
TABLE 2
                                          24 EFFECTIVE      °pu ABUNDANCE AND UNCERTAINTYa'b CORRESPONDING TO DIFFERENT ISOTOPIC COMPOSITION
                                                    Approximate Abundance (%)
BURNUP
(MWd/t)                                239
                        23pu                pu          240pu            241pu          242 pu          24°PUeff
8,000
10,000                    0.10          87            10                2.5            0.3      10.75 +/- 0.03(0.3%)
16,000
18,000                    0.25          75            18                4.5            1.0      20.30 +/- 0.08(0.4%)
25,000
27,000                    1.0            58            25                9.0            7.0      39.14 +/- 0.50(1.3%)
38,000
40,000                    2.0            45            27                15.0            12.0      52.00 +/- 0.87(1.7%)
    aComputed using the equation given in footnote 2.
 
bplutonium isotopic compositions were selected based on light-water-reactor fuel exposures.
 
assayed by spontaneous fission detection should                response for each assay. If not used routinely, the source addition technique should be applied to a periodically be selected for assay by an independent technique. Calorimetry (Ref. 2) can be used to assay a          random selection of items with a frequency comparable random selection of scrap in containers and to provide          to the assay schedule. The results of random applica reliable data that should be fed back into the calibra          tions of the source addition technique can be used in two ways:
tion fitting procedure to improve spontaneous fission detection calibration. The original calibration standards should be retained as working standards.                           1. As an average correction factor to be applied to a group of items, and
6. MEASUREMENT CONTROL                                              2. As a check on the item being assayed to verify that it is similar to the standards used in calibration and For proper measurement control, on each day that            that no additional matrix effects are present, ie., purely as a qualitative assurance that the calibration is valid.
 
scrap is assayed, a secondary standard should be assayed as a background measurement. Also, on each day that scrap is assayed, control (or working) standards should       
 
===7. ERROR ANALYSIS===
be assayed for normalization and for ensuring reliable operation.                                                         The sources of error in spontaneous fission detection are discussed in Regulatory Guide 5.11. Analysis of the The source addition technique (Ref. 10) is recom            error in the calibration is discussed in ANSIN15.20-1975 and in References 4 and 13.
 
mended for correcting the spontaneous fission detection
                                                          5.34-5
 
REFERENCES
1. J. F. Lemming and D. A. Rakel, "Guide to Pluto              8. N. Ensslin, J. Stewart, and J. Sapir, "Self nium Isotopic Measurements Using Gamma-Ray                    Multiplication  Correction Factors for Neutron Spectroscopy," MLM-2981, August 1982.                        Coincidence Counting," Nuclear Materials Manage ment, Vol. VIII, No. 2, p. 60, 1979.
 
2. U.S. Nuclear Regulatory Commission, "Calorimetric Assay for Plutonium," NUREG-0228, 1977.
 
9. M. S. Krick, "Neutron Multiplication Corrections
3. N. Ensslin et al., "Neutron Coincidence Counters                for Passive Thermal Neutron Well Counters," Los for Plutonium Measurements," Nuclear Materials                Alamos Scientific Laboratory, LA-8460-MS, 1980.
 
Management, Vol. VII, No. 2, p. 43, 1978.
 
10. H. 0. Menlove and R. B. Walton, "41r Coincidence
4. R. Sher, "Operating Characteristics of Neutron                  Unit for One-Gallon Cans and Smaller Samples,"
    Well Coincidence Counters," Brookhaven National                Los Alamos Scientific Laboratory, LA-4457-MS,
    Laboratory, BNL-50332, 1972.                                  1970.
 
5. K. Boehnel, "Determination of Plutonium in Nuclear Fuels Using the Neutron Coincidence Method,"              11. H. 0. Menlove, "Matrix Material Effects on Fission AWRE-Trans-70(54/4252) (English translation of                Neutron Counting Using Thermal- and Fast-Neutron KfK 2203), 1978.                                              Detectors,"    Los Alamos Scientific Laboratory, LA-4994-PR, p. 4, 1972.
 
6. M. S. Zucker, "Neutron Correlation Counting for the Nondestructive Analysis of Nuclear Materials,"        12. K. R. Alvar, H. R. Lukens, and N. A. Lurie, in Analytical Methods for Safeguards and Account              "Standard Containers for SNM Storage, Transfer, ability Measurements of Special Nuclear Materials,            and    Measurement,"    U.S.  Nuclear  Regulatory NBS    Special  Publication    528,  pp. 261-283,            Commission, NUREG/CR-1847, 1980.
 
November 1978.
 
7. J. D. Hastings and W. W. Strohm, "Spontaneous              13. J. Jaech, "Statistical Methods in Nuclear Material Fission Half-Life of 2 3 8 Pu,' Journal of Inorganic          Control," Atomic Energy Commission, TID-26298, and Nuclear Chemistry, Vol. 34, p. 25, 1972.                  Section 3.3.8, 1974.
 
BIBLIOGRAPHY
    American National Standards Institute, "Standard              Brouns, R. J., F. P. Roberts, and U. L. Upson, Test Methods for Nondestructive Assay of Special              "Considerations for Sampling Nuclear Materials for Nuclear Materials Contained in Scrap and Waste,"              SNM Accounting Measurements,"          U.S. Nuclear ANSI/ASTM C 853-79, 1979.                                      Regulatory Commission, NUREG/CR-0087, 1978.
 
5.34-6
 
APPENDIX
                                            Procedure for Converting M( 2 4 0)eff to M(total Pu)
                                                          and Sample Calculation When the measurement situation dictates the expres f242 = (2.0 +/- 0.2)% = 0.020 +/- 0.002 sion
  24 0 of the primary assay result as "effective grams of pu," it is necessary to convert this result to total                Using these results in Equation 3, we have:
  grams of plutonium using the relationship between these two quantities and the known isotopic composi                          M(total Pu) = 10.0/[0.20 + 1.64 x 0.02 tion of the plutonium sample. Let f 2 38,' f2 3 9 ' f 2 40 '
  f241' f242 represent the weight fractions of the pluto                                      + 2.66 x 0.01]
  nium isotopes in the unknown sampl
 
====e. The effective====
  24°pu mass from coincidence counting, M( 2 4 0)eff, and                                  = 10.0/0.259 the individual masses of the spontaneously fissioning plutonium isotopes are related by:                                                        = 38.6 grams M( 2 4 0)eff = M(240) + 1.64M(242)                                      To obtain the value of the variance of the M(total Pu) result, we must propagate the variances of the
                      + 2.66M(238)                              (1)        M( 2 4 0)eff and the isotopic weight fractions. Let the variance in M( 24 0)eff = cieff, and let the variances The masses of the 2 4 2 Pu and 2 3 8 pU isotopes can be                  in the relevant plutonium weight fractions be G238'
  "expressed in terms of M(240), using the isotopic weight                  2
                                                                          0240'2j  and G:42.
 
4    The variance of the total plutonium fractions, so that:                                                      mass, apu, is given by:
      M( 2 4 0)eff = M(240)[f  2 40    + 1.64f 2 4 2                            2  = [M(total Pu)] 2  {[ Oeff/M( 2 4 0)eff] 2
                      + 2.66f 2 3 8 1/f 240                    (2)                    + [ 242 + (1.6 4    24  )2 + (2.660238)]/
S Since M(240)/f 2 4 0 = M(total Pu), we have the final                                [f240 + 1.64f 2 4 2 + 2.66f 2 38 ] 2}      (5)
  results:
                                                                                                            0
                                                                          In our example calculation,        eff = 0.5 gram, 02ý8 =
                          24                                              0.005, 0240 = 0.004, and 0242 = 0.002. The variance M(total Pu) = M(      0)eff/[f 2 4 o  +  1.64f 24 2 in the total plutonium          mass is therefore given by:
                        + 2.66f 2 3 8 ]                        (3)              2  = IM(total Pu)]2 [(0.5/10.0)2 The quantity in the denominator of Equation 3 is called the " 2 40 Pu effective weight fraction, f 2 4 0 (effect                      + 0.000204/(0.259)2 ]
  ive)." Thus the total plutonium mass can be expressed as the 2 4 0 Pu effective mass divided by the 2 4 0 pu                        0
                                                                                Pu = M(total Pu) [(0.5/10.0)2 effective weight fraction:
                                                                                      + 0.000204/(0.259)2] 1/2 M(total Pu) = M(240)eff/f 2 4 o(effective)                (4)
                                                                                    = 38.6 x 0.074 As an example, suppose that the net coincidence count from an unknown sample indicates 10.0 +/- 0.5                                = 2.9 grams effective grams of 2 4 0 Pu. Furthermore, suppose that the plutonium isotopic composition of the unknown                      Thus the final assay result from this coincidence count sample was previously established to be:                                is quoted as:
      f238 = (1.0 +/- 0.5)% = 0.010 +/- 0.005                                      M(total Pu) = 38.6 +/- 2.9 grams.
 
f239 = (73.0 +/- 0.5)%                                                    For most plutonium samples, the dominant measure ment uncertainties will be in the 2 4 °pu effective mass f240 = (20.0 +/- 0.4)% = 0.200 +/- 0.004                                and the 2 4 0 pU isotopic weight fraction, f24 0 . Thus good precision in M(total Pu) is achieved primarily through f241 = (4.0 +/- 0.2)%                                                minimizing the uncertainties in these quantities.
 
5.34-7
 
VALUE/IMPACT STATEMENT                                                        -V
1. PROPOSED ACTION                                                1.3.3 Industry
1.1    Description                                                Since industry is already applying the techniques discussed in the guide, updating these techniques should Licensees authorized to possess at any one time            have no adverse impact.
 
more than one effective kilogram of plutonium are required in § 70.51 of 10 CFR Part 70, "Domestic                    1.3.4 Public Licensing of Special Nuclear Material," to establish and maintain a system of control and accountability so                No impact on the public can be foreseen.
 
that the standard error (estimator) associated with the inventory difference (SEID) ascertained as a result of a        1.4    Decision on Proposed Action measured material balance meets minimum standards.
 
The guide should be revised to reflect improvements Included in a typical material balance are containers      in the technique and to bring the language of the of inhomogeneous scrap material that are not amenable          guide into conformity with current usage.
 
to assay by the traditional method of sampling and chemical analysis. With proper controls, the nondestruc       
 
===2. TECHNICAL APPROACH===
tive assay (NDA) technique of spontaneous fission detection is one acceptable method for the assay of                Not applicable.
 
plutonium in containers of bulk scrap material. The use of spontaneous fission detection thus facilitates the         
 
===3. PROCEDURAL APPROACH===
preparation of a complete plant material balance whose SEID meets established requirements.                              Of the procedural alternatives considered, revision of the existing regulatory guide was selected as the most advantageous and cost effective.
 
Regulatory Guide 5.34 was issued in June 1974 to describe procedures acceptable to the NRC staff for            4. STATUTORY CONSIDERATIONS
applying the NDA technique of spontaneous fission detection to plutonium in scrap.                              4.1    NRC Authority Authority for this guide is derived from the safety
1.2    Need for Proposed Action                                requirements of the Atomic Energy Act through the Commission's regulations, in particular, § 70.51 of Improvements in technology have occurred since            10 CFR Part 70.
 
Regulatory Guide 5.34 was issued, and the proposed action is needed to bring it up to date.                      4.2    Need for NEPA Assessment The proposed action is not a major action that may
1.3    Value/Impact of Proposed Action                        significantly affect the quality of the human environ ment and does not require an environmental impact
    1.3.1 NRC Operations                                      statement.
 
The improvements in technology that have occurred          5.    RELATIONSHIP TO OTHER EXISTING OR
since the guide was issued will be made available for                PROPOSED REGULATIONS OR POLICIES
the regulatory procedure. Using these updated tech                The proposed action is one of a series of revisions niques should have no adverse impact.
 
of existing regulatory guides on NDA techniques.
 
1.3.2  Other Government Agencies                          6. SUMMARY AND CONCLUSIONS
    Not applicable.                                                Regulatory Guide 5.34 should be updated.
 
5.34-8
 
UNITED STATES
                                    $I RST CLASS MAIL
NUCLEAR REGULATORY COMMISSION      POSTAGE & FEESPAID
      WASHINGTON, D.C. 20555              USSNAC
                                        WASH D C
                                      PERMITNo -9k OFFICIAL BUSINESS
    PENALTY FOR PRIVATE USE. $300}}


{{RG-Nav}}
{{RG-Nav}}

Latest revision as of 11:27, 28 March 2020

(Task SG 046-4), Nondestructive Assay for Plutonium in Scrap Material by Spontaneous Fission Detection
ML003739949
Person / Time
Issue date: 05/31/1984
From:
Office of Nuclear Regulatory Research
To:
References
RG-5.34, Rev 1
Download: ML003739949 (9)


Revision 1"

U.S. NUCLEAR REGULATORY COMMISSION May 1984

0

SREGULATORY

OFFICE OF NUCLEAR REGULATORY RESEARCH

GUIDE

REGULATORY GUIDE 5.34 (Task SG 046-4)

NONDESTRUCTIVE ASSAY FOR PLUTONIUM IN SCRAP MATERIAL

BY SPONTANEOUS FISSION DETECTION

A. INTRODUCTION

standard error. Unlike the major quantity of material flowing through the process, scrap is typically Section 70.51, "Material Balance, Inventory, and inhomogeneous and difficult to sample. Therefore, a Records Requirements," of 10 CFR Part 70, "Domestic separate assay of the entire content of each container of Licensing of Special Nuclear Material," requires certain scrap material is a more reliable method of scrap account licensees authorized to possess at any one time more ability. NDA is a method for assaying the entire content than one effective kilogram of special nuclear material of every container of scrap.

to establish and maintain a system of control and accountability so that the standard error (estimator) The term "scrap" refers to material that is generated associated with the inventory difference (SEID), from the main process stream because of the ineffi obtained as a result of a measured material balance, ciency of the process. Scrap material is generally meets minimum standards. This guide is intended for economically recoverable. Scrap, therefore, consists of those licensees who possess plutonium scrap materials rejected or contaminated process material such as pellet and who are also subjected to the requirements of grinder sludge, sweepings from gloveboxes, dried filter

§ 70.51 of 10 CFR Part 70. sludge, and rejected powder and pellets. Scrap is generally distinguished from "waste" by the density or concentra Included in a typical material balance are containers tion of heavy elements in the two materials, but it is of inhomogeneous scrap material that are not amenable the recovery cost (per mass unit of special nuclear to assay by the traditional method of sampling and material) that determines whether a material is "scrap"

chemical analysis. With proper controls, the non or "waste." The concentration of uranium and pluto destructive assay (NDA) technique of spontaneous nium in scrap is approximately the same as it is in fission detection is one acceptable method for the assay process material, i.e., 85-90 percent (uranium + pluto of plutonium in containers of bulk scrap material. The nium) by weight. However, on occasion the fraction in use of spontaneous fission detection thus facilitates the both process and scrap material can be less than 25 preparation of a complete plant material balance whose percent. Plutonium in fast reactor scrap material is SEID meets established requirements. 15-20 percent by weight and in thermal reactor recycle material, 2-9 percent by weight. The main difference This guide describes procedures acceptable to the between scrap and process material is that scrap is NRC staff for applying the NDA technique of contaminated and inhomogeneous. Waste, on the other spontaneous fission detection to plutonium in scrap. hand, contains a low concentration of uranium and plutonium, ie., a few percent or less (uranium + pluto Any guidance in this document related to informa nium) by weight. However, the recovery of combustible tion collection activities has been cleared under OMB waste by incineration may produce ash that is high in Clearance No. 3150-0009. uranium and plutonium concentrations. Such incinerator ash is also considered "scrap" in this guide. However, it

B. DISCUSSION

should be noted that ash may be more homogeneous in Plutonium in scrap material can contribute signif

  • The substantial number of changes in this revision has made icantly to the inventory difference and its associated it impractical to indicate the changes with lines in the margin.

USNRC REGULATORY GUIDES Comments should be sent to the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Regulatory Guides are issued to describe and make available to the Attention: Docketing and Service Branch.

public methods acceptable to the NRC staff of implementing specific parts of the Commission's regulations, to delineate tech- The guides are issued in the following ten broad divisions:

niques used by the staff in evaluating specific problems or postu lated accidents or to provide guidance to applicants. Regulatory 1. Power Reactors 6. Products Guides are no? substitutes for regulations, and compliance with 2. Research and Test Reactors 7. Transportation them is not required. Methods and solutions different from those set 3. Fuels and Materials Facilities 8. Occupational Health out in the guides will be acceptable if they provide a basis for the 4. Environmental and Siting 9. Antitrust and Financial Review findings requisite to the issuance or continuance of a permit or 5. Materials and Plant Protection 10. General license by the Commission.

Copies of issued guides may be purchased at the current Government This guide was issued after consideration of comments received from Printing Office price. A subscription service for future guides in spe the public. Comments and suggestions for improvements in these cific divisions is available through the Government Printing Office.

guides are encouraged at all times, and guides will be revised, as Information on the subscription service and current GPO prices may appropriate, to accommodate comments and to reflect new Informa- be obtained by writing the U.S. Nuclear Regulatory Commission, tion or experience. Washington, D.C. 20555, Attention: Publications Sales Manager.

its characteristics compared to most scrap and may, This guide gives recommendations useful for the assay therefore, be accountable using sampling and chemical by spontaneous fission detection of containers, each analysis methods. containing a few liters of scrap and having contents ranging from a few grams to 10 kilograms of plutonium or up to approximately 2 kilograms of effective

240

Pu 2 NDA of plutonium can be accomplished primarily by the passive methods of gamma ray spectrometry, (see Ref. 7). Containers with a significant plutonium calorimetry, and spontaneous fission detection. Active content (i.e., 50 grams or more) give a spontaneous neutron methods using total count rates or delayed fission response that must be corrected for the effects neutron detection can also be used in scrap assay of neutron multiplication (Refs. 8, 9). Scrap materials measurements. Regulatory Guide 5.11, "Nondestructive that have large loadings of plutonium in addition to Assay of Special Nuclear Material Contained in Scrap fluorine, oxygen, or other alpha/neutron-producing and Waste," provides a framework for the use of these elements are difficult to measure and correct for multi

1 NDA methods. plication effects because of the large random neutron flux from the (ct,n) reactions in the matrix materials.

The NDA of dense scrap materials using gamma ray These samples should be segregated into smaller quanti spectroscopy can be unreliable because of severe gamma ties for measurements. In general, a large quantity of ray attenuation. However, the isotopic composition of plutonium can be assayed by spontaneous fission detec plutonium in scrap materials, with the exception of tion by subdividing the scrap into smaller amounts, or

242pu, can be obtained quite reliably using high-resolution the items may be more amenable to assay by calorim gamma ray spectrometry measurements (Ref. 1). etry.

C. REGULATORY POSITION

Calorimetry is an accurate method of plutonium assay when there is an accurate knowledge of the The spontaneous fission detection method for the relative abundance of each plutonium isotope and NDA of plutonium in bulk inhomogeneous scrap material

24 tAm. Scrap may contain a mixture of materials of should include (1) discrimination of spontaneous fission different radionuclide compositions, especially different radiations from random background by coincidence

241Am concentrations, thereby necessitating the measure techniques and (2) measurement of the relative pluto ment of the average radionuclide composition. The nium isotopic composition of the scrap. An acceptable average radionuclide abundances can be accurately meas spontaneous fission detection method of plutonium ured only when the scrap is reasonably homogeneous. assay is described below.

When the radionuclide abundances can be accurately measured or controlled, calorimetry can be applied to 1. SPONTANEOUS FISSION DETECTION SYSTEM

scrap assay (Ref. 2). However, calorimetry is time con suming for materials of high heat capacity and may 1.1 Detectors not be a practical method for the routine assay of large numbers of containers. Instruments based on moderated thermal neutron detectors, i.e., neutron well coincidence counters, are Spontaneous fission detection is a practical NDA recommended for applications in which the gross technique for the assay of plutonium in scrap material. neutron detection rate does not exceed 2 x 105 The assay method involves the passive counting of neutrons/sec. The dead time inherent in these slow spontaneous fission neutrons emitted primarily from the coincidence systems can be reduced by employing a fission of 240 Pu. Neutron coincidence counters are used shift-register coincidence circuit. If the gross neutron to detect these time-correlated neutrons. The theory and detection rate is Lprimarily due to random background practice of neutron coincidence counting for plutonium and exceeds 2 x 10 neutrons/sec, a fast-neutron-detection, assay are discussed thoroughly in References 3 through 6. single-coincidence system can be used, provided adequate Spontaneous fission neutrons are sufficiently penetrating corrections can be made for matrix effects. Matrix to provide a representative signal from all the plutonium effects are more severe in fast-neutron-detection systems, within a container. Since the neutron coincidence signal as shown in Table 1.

is dependent on both the quantity and relative abundance

8 240

of 2 3 Pu, pu, and 242pu, the plutonium isotopic

2 composition must be known for assay of total plutonium The effective 24 0 Pu mass is a weighted average of the mass by spontaneous fission detection. The quantity of scrap of each of the plutonium isotopes. The weighting is equal to the spontaneous

0

fission neutron yield of each isotope relative to that material on inventory when a material balance is com of 2 4Pu. Since only the even-numbered isotopes have significant puted can be reduced through good management, and spontaneous fission rates, the effective 240 Pu mass is given approxi mately by:

the scrap remaining on inventory can be assayed by M(240)eff = M(240) + (1.64 + 0.07)M(242)

spontaneous fission detection to meet the overall plant inventory difference (ID) and SEID constraints required + (2.66 +/- 0.19)M(238)

by paragraph 70.5 1(e)(5) of 10 CFR Part 70. where M is the mass of the isotope indicated in parentheses. The uncertainties in the coefficients and in the effective 240 Pu abun dances in the table are from the reported standard deviations in the most reliable data available (Ref. 7). The mathematical procedure for converting from M(240)eff to M(total Pu) is presented in the

1Revision I to this guide was issued in April 1984. appendix to this guide together with a sample calculation.

5.34-2

TABLE 1 MATRIX MATERIAL EFFECTS ON NEUTRON ASSAY

Correcteda (Ref. 10)

Neutron Detection Efficiency (Ref. 11) Coincidence Coincidence Efficiency, Efficiency,

3 4 3 Matrix Material Mass He Detector, He Detector, ZnS Detector, He Detector, 3He Detector, (in %4-liter can) (kg) Thermal Fast Fast Thermal Thermal Empty Can - 1.00 1.00 1.00 1.00 1.00

Carbon Pellets 1.89 1.03 - - 1.05 0.97 Metal 3.60 1.04 0.83 0.75 1.09 1.02 Slag-Crucible 1.80 1.03 0.94 0.91 1.08 1.01 Concrete 3.24 1.05 0.84 0.79 1.10 1.02 String Filters 0.60 1.07 0.95 0.86 1.17 1.05 CH 2 (p=0. 6 5 g/cc) 0.27 1.06 0.96 0.92 1.11 1.00

CH 2 (p=0.1 2 g/cc) 0.43 1.09 0.92 0.90 1.19 0.98 CH 2 (p=0. 2 7 g/cc) 0.97 1.19 0.71 0.67 1.36 0.04 H120 (p=l.00 g/cc) 3.62 0.98 0.36 0.35 0.98 0.96 aCorrected using the source addition technique (see Ref. 7).

1.2 Detection Chamber uniformity of spatial response, and insensitivity to matrix effects. Therefore, information should be The chamber should permit reproducible positioning obtained regarding:

of standard-sized containers in the location of maximum spatial response uniformity. 1. The precision of the coincidence response as a function of the real-coincidence counting rate and the

1.3 Fission Source accidental-to-real-coincidence ratio. Extremes in the back ground or accidental-coincidence rate can be simulated A spontaneous fission source with a neutron intensity by using a source of random neutrons (nonfission).

comparable to the intensity of the largest plutonium mass to be assayed should be used for making matrix 2. The uniformity of spatial response. Graphs should corrections using the source addition technique (Ref. 10). be obtained on the relative coincidence response to a A nanogram of 252Ca is approximately equivalent to a small fission neutron source as a function of position in gram of effective 2 40 Pu. the counting chamber.

1.4 Readout 3. The sensitivity of matrix interference. A table of the relative coincidence response to a small fission Readout should allow computation of the accidental neutron source as a function of the composition of the to-real-coincidence ratio in addition to the net real matrix material surrounding the point source should be coincidence rate. Live-time readout or a means of obtained. Included in the matrix should be materials computing the dead time should also be provided. considered representative of common scrap materials.

Table 1 is an example of such a tabulation of the

1.5 Perfonnance Specifications relative response for a wide range of materials.

The performance of a spontaneous fission detection This information should be used for evaluating the instrument should be evaluated according to its stability, expected instrument performance and for estimating

5.34-3

errors. The above performance information can be 6. Density (both average density and local density requested from the instrument suppliers during instru extremes should be considered), and

3/4'

ment selection and should be verified during preopera tional instrument testing. 7. Matrix composition.

2. ANALYST

5. CALIBRATION

A trained individual should oversee spontaneous Guidelines for calibration and measurement control fission detection assay of plutonium and should have for NDA are available in Regulatory Guide 5.53, "Qualifi primary responsibility for instrument specification, cation, Calibration, and Error Estimation Methods for preoperational instrument testing, standards and calibra Nondestructive Assay," which endorses ANSI N15.20

tion, an operation manual, measurement control, and 1975, "Guide to Calibrating Nondestructive Assay error analysis. Experience or training equivalent to a Systems." 3 The guide and standard include details on bachelor's degree in science or engineering from an calibration standards, calibration procedures, curve fitting, accredited college or university and a laboratory course and error analysis. Guidelines relevant to spontaneous in radiation measurement should be the minimum fission detection are given below.

qualifications of the analyst. The spontaneous fission detection analyst should frequently review the sponta Calibration can be used for either a single isotopic neous fission detection operation and should authorize composition or variable isotopic mixtures. In the former any changes in the operation. case, the resulting calibration curve will be used to convert "net real-coincidence count" to "grams pluto

3. CONTAINERS AND PACKAGING nium." In the latter case, the conversion is from "net real-coincidence count" to "effective grams 24°pu."

A single type of container should be used for The mathematical procedure for converting from packaging all scrap in each category. A uniform con effective grams 2 4 0 pu, M( 24 0 )eff, to total grams pluto tainer that would facilitate accurate measurement and nium, M(total Pu), is presented in the appendix to this would standardize this segment of instrument design, guide together with a sample calculation.

e.g., a thin-walled metal (steel) can with an inside diameter between 10 and 35 cm, is recommended. For A minimum of four calibration standards with further guidance on container standardization in NDA isotopic compositions similar to those of the unknowns measurements, see Reference 12. should be used for calibration. If practicable, a calibra tion curve should be generated for each isotopic blend

4. REDUCING ERROR DUE TO MATERIAL of plutonium. When plutonium of different isotopic VARIABILITY composition is assayed using a single calibration, the effect of isotopic composition on the spontaneous The variation in spontaneous fission detection fission detection response should be determined over the response due to material variability in scrap should be operating ranges by measuring standards of different reduced by (1) segregating scrap into categories that are plutonium isotopic compositions. This is necessary independently calibrated, (2) correcting for matrix because the use of the effective 2 40 pu concept can lead effects using the source addition technique (Ref. 10), or to error owing to the uncertainty in the spontaneous

(3) applying both the categorization and the source fission half-lives and the variation in response with addition technique. Categorization should be used if the isotopic composition. Table 2 illustrates the uncertainty spontaneous fission detection method is more sensitive in effective 2 40 Pu abundance with different isotopic to the material variability from scrap type to scrap type compositions (Ref. 13).

than to the material variability within a scrap type.

Application of the source addition technique reduces the Calibration standards should be fabricated from sensitivity to material variability and may allow the material having a plutonium content determined by a majority of scrap types to be assayed under a single technique traceable to or calibrated with the standard calibration. Material characteristics that should be reference material of the National Bureau of Standards.

considered in selecting categories include: Well-characterized homogeneous material similar to the process material from which the scrap is generated can

1. Plutonium isotopic composition and content, be used to obtain calibration standards.

2. Uranium/plutonium ratio, Fabrication of calibration standards that are truly representative of the unknowns is impossible for scrap

3. Types of container and packaging, assay. To measure the reliability of the calibration based on the fabricated standards discussed above and to

4. Abundance of high-yield alpha/neutron material, improve this calibration, unknowns that have been i.e., low-atomic-number impurities, 3 Copies of this standard may be obtained from the American National Standards Institute, Inc., 1430 Broadway, New York,

5. Size and distribution of materials in packages, New York 10018.

5.34-4

TABLE 2

24 EFFECTIVE °pu ABUNDANCE AND UNCERTAINTYa'b CORRESPONDING TO DIFFERENT ISOTOPIC COMPOSITION

Approximate Abundance (%)

BURNUP

(MWd/t) 239

23pu pu 240pu 241pu 242 pu 24°PUeff

8,000

10,000 0.10 87 10 2.5 0.3 10.75 +/- 0.03(0.3%)

16,000

18,000 0.25 75 18 4.5 1.0 20.30 +/- 0.08(0.4%)

25,000

27,000 1.0 58 25 9.0 7.0 39.14 +/- 0.50(1.3%)

38,000

40,000 2.0 45 27 15.0 12.0 52.00 +/- 0.87(1.7%)

aComputed using the equation given in footnote 2.

bplutonium isotopic compositions were selected based on light-water-reactor fuel exposures.

assayed by spontaneous fission detection should response for each assay. If not used routinely, the source addition technique should be applied to a periodically be selected for assay by an independent technique. Calorimetry (Ref. 2) can be used to assay a random selection of items with a frequency comparable random selection of scrap in containers and to provide to the assay schedule. The results of random applica reliable data that should be fed back into the calibra tions of the source addition technique can be used in two ways:

tion fitting procedure to improve spontaneous fission detection calibration. The original calibration standards should be retained as working standards. 1. As an average correction factor to be applied to a group of items, and

6. MEASUREMENT CONTROL 2. As a check on the item being assayed to verify that it is similar to the standards used in calibration and For proper measurement control, on each day that that no additional matrix effects are present, ie., purely as a qualitative assurance that the calibration is valid.

scrap is assayed, a secondary standard should be assayed as a background measurement. Also, on each day that scrap is assayed, control (or working) standards should

7. ERROR ANALYSIS

be assayed for normalization and for ensuring reliable operation. The sources of error in spontaneous fission detection are discussed in Regulatory Guide 5.11. Analysis of the The source addition technique (Ref. 10) is recom error in the calibration is discussed in ANSIN15.20-1975 and in References 4 and 13.

mended for correcting the spontaneous fission detection

5.34-5

REFERENCES

1. J. F. Lemming and D. A. Rakel, "Guide to Pluto 8. N. Ensslin, J. Stewart, and J. Sapir, "Self nium Isotopic Measurements Using Gamma-Ray Multiplication Correction Factors for Neutron Spectroscopy," MLM-2981, August 1982. Coincidence Counting," Nuclear Materials Manage ment, Vol. VIII, No. 2, p. 60, 1979.

2. U.S. Nuclear Regulatory Commission, "Calorimetric Assay for Plutonium," NUREG-0228, 1977.

9. M. S. Krick, "Neutron Multiplication Corrections

3. N. Ensslin et al., "Neutron Coincidence Counters for Passive Thermal Neutron Well Counters," Los for Plutonium Measurements," Nuclear Materials Alamos Scientific Laboratory, LA-8460-MS, 1980.

Management, Vol. VII, No. 2, p. 43, 1978.

10. H. 0. Menlove and R. B. Walton, "41r Coincidence

4. R. Sher, "Operating Characteristics of Neutron Unit for One-Gallon Cans and Smaller Samples,"

Well Coincidence Counters," Brookhaven National Los Alamos Scientific Laboratory, LA-4457-MS,

Laboratory, BNL-50332, 1972. 1970.

5. K. Boehnel, "Determination of Plutonium in Nuclear Fuels Using the Neutron Coincidence Method," 11. H. 0. Menlove, "Matrix Material Effects on Fission AWRE-Trans-70(54/4252) (English translation of Neutron Counting Using Thermal- and Fast-Neutron KfK 2203), 1978. Detectors," Los Alamos Scientific Laboratory, LA-4994-PR, p. 4, 1972.

6. M. S. Zucker, "Neutron Correlation Counting for the Nondestructive Analysis of Nuclear Materials," 12. K. R. Alvar, H. R. Lukens, and N. A. Lurie, in Analytical Methods for Safeguards and Account "Standard Containers for SNM Storage, Transfer, ability Measurements of Special Nuclear Materials, and Measurement," U.S. Nuclear Regulatory NBS Special Publication 528, pp. 261-283, Commission, NUREG/CR-1847, 1980.

November 1978.

7. J. D. Hastings and W. W. Strohm, "Spontaneous 13. J. Jaech, "Statistical Methods in Nuclear Material Fission Half-Life of 2 3 8 Pu,' Journal of Inorganic Control," Atomic Energy Commission, TID-26298, and Nuclear Chemistry, Vol. 34, p. 25, 1972. Section 3.3.8, 1974.

BIBLIOGRAPHY

American National Standards Institute, "Standard Brouns, R. J., F. P. Roberts, and U. L. Upson, Test Methods for Nondestructive Assay of Special "Considerations for Sampling Nuclear Materials for Nuclear Materials Contained in Scrap and Waste," SNM Accounting Measurements," U.S. Nuclear ANSI/ASTM C 853-79, 1979. Regulatory Commission, NUREG/CR-0087, 1978.

5.34-6

APPENDIX

Procedure for Converting M( 2 4 0)eff to M(total Pu)

and Sample Calculation When the measurement situation dictates the expres f242 = (2.0 +/- 0.2)% = 0.020 +/- 0.002 sion

24 0 of the primary assay result as "effective grams of pu," it is necessary to convert this result to total Using these results in Equation 3, we have:

grams of plutonium using the relationship between these two quantities and the known isotopic composi M(total Pu) = 10.0/[0.20 + 1.64 x 0.02 tion of the plutonium sample. Let f 2 38,' f2 3 9 ' f 2 40 '

f241' f242 represent the weight fractions of the pluto + 2.66 x 0.01]

nium isotopes in the unknown sampl

e. The effective

24°pu mass from coincidence counting, M( 2 4 0)eff, and = 10.0/0.259 the individual masses of the spontaneously fissioning plutonium isotopes are related by: = 38.6 grams M( 2 4 0)eff = M(240) + 1.64M(242) To obtain the value of the variance of the M(total Pu) result, we must propagate the variances of the

+ 2.66M(238) (1) M( 2 4 0)eff and the isotopic weight fractions. Let the variance in M( 24 0)eff = cieff, and let the variances The masses of the 2 4 2 Pu and 2 3 8 pU isotopes can be in the relevant plutonium weight fractions be G238'

"expressed in terms of M(240), using the isotopic weight 2

0240'2j and G:42.

4 The variance of the total plutonium fractions, so that: mass, apu, is given by:

M( 2 4 0)eff = M(240)[f 2 40 + 1.64f 2 4 2 2 = [M(total Pu)] 2 {[ Oeff/M( 2 4 0)eff] 2

+ 2.66f 2 3 8 1/f 240 (2) + [ 242 + (1.6 4 24 )2 + (2.660238)]/

S Since M(240)/f 2 4 0 = M(total Pu), we have the final [f240 + 1.64f 2 4 2 + 2.66f 2 38 ] 2} (5)

results:

0

In our example calculation, eff = 0.5 gram, 02ý8 =

24 0.005, 0240 = 0.004, and 0242 = 0.002. The variance M(total Pu) = M( 0)eff/[f 2 4 o + 1.64f 24 2 in the total plutonium mass is therefore given by:

+ 2.66f 2 3 8 ] (3) 2 = IM(total Pu)]2 [(0.5/10.0)2 The quantity in the denominator of Equation 3 is called the " 2 40 Pu effective weight fraction, f 2 4 0 (effect + 0.000204/(0.259)2 ]

ive)." Thus the total plutonium mass can be expressed as the 2 4 0 Pu effective mass divided by the 2 4 0 pu 0

Pu = M(total Pu) [(0.5/10.0)2 effective weight fraction:

+ 0.000204/(0.259)2] 1/2 M(total Pu) = M(240)eff/f 2 4 o(effective) (4)

= 38.6 x 0.074 As an example, suppose that the net coincidence count from an unknown sample indicates 10.0 +/- 0.5 = 2.9 grams effective grams of 2 4 0 Pu. Furthermore, suppose that the plutonium isotopic composition of the unknown Thus the final assay result from this coincidence count sample was previously established to be: is quoted as:

f238 = (1.0 +/- 0.5)% = 0.010 +/- 0.005 M(total Pu) = 38.6 +/- 2.9 grams.

f239 = (73.0 +/- 0.5)% For most plutonium samples, the dominant measure ment uncertainties will be in the 2 4 °pu effective mass f240 = (20.0 +/- 0.4)% = 0.200 +/- 0.004 and the 2 4 0 pU isotopic weight fraction, f24 0 . Thus good precision in M(total Pu) is achieved primarily through f241 = (4.0 +/- 0.2)% minimizing the uncertainties in these quantities.

5.34-7

VALUE/IMPACT STATEMENT -V

1. PROPOSED ACTION 1.3.3 Industry

1.1 Description Since industry is already applying the techniques discussed in the guide, updating these techniques should Licensees authorized to possess at any one time have no adverse impact.

more than one effective kilogram of plutonium are required in § 70.51 of 10 CFR Part 70, "Domestic 1.3.4 Public Licensing of Special Nuclear Material," to establish and maintain a system of control and accountability so No impact on the public can be foreseen.

that the standard error (estimator) associated with the inventory difference (SEID) ascertained as a result of a 1.4 Decision on Proposed Action measured material balance meets minimum standards.

The guide should be revised to reflect improvements Included in a typical material balance are containers in the technique and to bring the language of the of inhomogeneous scrap material that are not amenable guide into conformity with current usage.

to assay by the traditional method of sampling and chemical analysis. With proper controls, the nondestruc

2. TECHNICAL APPROACH

tive assay (NDA) technique of spontaneous fission detection is one acceptable method for the assay of Not applicable.

plutonium in containers of bulk scrap material. The use of spontaneous fission detection thus facilitates the

3. PROCEDURAL APPROACH

preparation of a complete plant material balance whose SEID meets established requirements. Of the procedural alternatives considered, revision of the existing regulatory guide was selected as the most advantageous and cost effective.

Regulatory Guide 5.34 was issued in June 1974 to describe procedures acceptable to the NRC staff for 4. STATUTORY CONSIDERATIONS

applying the NDA technique of spontaneous fission detection to plutonium in scrap. 4.1 NRC Authority Authority for this guide is derived from the safety

1.2 Need for Proposed Action requirements of the Atomic Energy Act through the Commission's regulations, in particular, § 70.51 of Improvements in technology have occurred since 10 CFR Part 70.

Regulatory Guide 5.34 was issued, and the proposed action is needed to bring it up to date. 4.2 Need for NEPA Assessment The proposed action is not a major action that may

1.3 Value/Impact of Proposed Action significantly affect the quality of the human environ ment and does not require an environmental impact

1.3.1 NRC Operations statement.

The improvements in technology that have occurred 5. RELATIONSHIP TO OTHER EXISTING OR

since the guide was issued will be made available for PROPOSED REGULATIONS OR POLICIES

the regulatory procedure. Using these updated tech The proposed action is one of a series of revisions niques should have no adverse impact.

of existing regulatory guides on NDA techniques.

1.3.2 Other Government Agencies 6. SUMMARY AND CONCLUSIONS

Not applicable. Regulatory Guide 5.34 should be updated.

5.34-8

UNITED STATES

$I RST CLASS MAIL

NUCLEAR REGULATORY COMMISSION POSTAGE & FEESPAID

WASHINGTON, D.C. 20555 USSNAC

WASH D C

PERMITNo -9k OFFICIAL BUSINESS

PENALTY FOR PRIVATE USE. $300