ML051720202: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:LIST OF REFERENCE HANDOUTS PROVIDED TO CANDIDATES
{{#Wiki_filter:LIST OF REFERENCE HANDOUTS PROVIDED TO CANDIDATES FOR THE QUAD CITIES INITIAL EXAMINATION MAY 2005
                                        -
FOR THE QUAD CITIES INITIAL EXAMINATION MAY 2005


QUAD CITIES 2005 WRITTEN EXAMINATION LIST OF REFERENCE HANDOUTS PROVIDED Related          REFERENCE HANDOUTS PROVIDED                            REVISION Question                                                                    NUMBER
QUAD CITIES 2005 WRITTEN EXAMINATION LIST OF REFERENCE HANDOUTS PROVIDED Related          REFERENCE HANDOUTS PROVIDED                            REVISION Question                                                                    NUMBER Various All of the QGAs (with the Entry Conditions blanked out) with        Various the following exceptions:
    #
Various All of the QGAs (with the Entry Conditions blanked out) with        Various the following exceptions:
18    - For QGA 101, RPV Control (ATWS), the following was                10 blanked out: In the Power leg of the flowchart, the three (3) boxes just after the IF ... THEN ... conditional box at the beginning of the leg.
18    - For QGA 101, RPV Control (ATWS), the following was                10 blanked out: In the Power leg of the flowchart, the three (3) boxes just after the IF ... THEN ... conditional box at the beginning of the leg.
7 91    -    For QGA 100, RPV Control the following was blanked out:
7 91    -    For QGA 100, RPV Control the following was blanked out:

Revision as of 19:02, 14 March 2020

List of Reference Handouts Provided to Cadidates for the Quad Cities Initial Examination - May - 2005
ML051720202
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 05/31/2005
From: Melodee Jensen
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML051610145 List:
References
50-254/05-301, 50-265/05-301
Download: ML051720202 (2)


Text

LIST OF REFERENCE HANDOUTS PROVIDED TO CANDIDATES FOR THE QUAD CITIES INITIAL EXAMINATION MAY 2005

QUAD CITIES 2005 WRITTEN EXAMINATION LIST OF REFERENCE HANDOUTS PROVIDED Related REFERENCE HANDOUTS PROVIDED REVISION Question NUMBER Various All of the QGAs (with the Entry Conditions blanked out) with Various the following exceptions:

18 - For QGA 101, RPV Control (ATWS), the following was 10 blanked out: In the Power leg of the flowchart, the three (3) boxes just after the IF ... THEN ... conditional box at the beginning of the leg.

7 91 - For QGA 100, RPV Control the following was blanked out:

In the Pressure leg of the flowchart, everything after the IF

... THEN ... conditional box at the beginning of the leg.

NIA - For QGA 500-1, RPV Blowdown, everything after the IF 11

. .. THEN ... conditional box in the middle of the page just below the centerline of the page.

46 Technical Specification 3.3.8.1 Amendment 1991195 59 Steam Tables NIA 65 QCOS 0201-08, Attachment B 36 67 QCOP 0202-13, Attachment 6 , Page 1 of 2, Quad Cities 10 Power Flow Map For Normal Feedwater Temperature 81,88 EP-AA-1006, Appendix 3 (Emergency Action Levels, Quad 19 Cities Annex) 82 QCOA 0010-12, FireIExplosion 25 87 Technical Specification 5.5.7 Amendment 1991195 89 Technical Specification 3.6.1.3 Amendment 1991195 Technical Requirements Manual (TRM) Appendix A, Table A-1 , Primary Containment Isolation Devices (Unit 1) QC-TRM-04-001 Page 1 of 1