ML18012A878: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML18012A878
| number = ML18012A878
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| release date = 08/31/2018
| package contents = {{Adams package content
| package contents = {{Adams package content
| number = ML18012A881
| number = ML18012A881
| issue date = 08/01/1995
| issue date = 08/01/1995
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| title = Rev 0 to 14980-98207, Fire Endurance Test of Wall Assembly Clad w/Thermo-Lag 330-1.
| author name = HUMPHREY C A, STANSBERRY H W
| author name = Humphrey C, Stansberry H
| author affiliation = OMEGA POINT LABORATORIES
| author affiliation = OMEGA POINT LABORATORIES
| addressee name =  
| addressee name =  
Line 20: Line 21:
| number = ML18012A880
| number = ML18012A880
| issue date = 05/30/1995
| issue date = 05/30/1995
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| title = Rev 0 to 14980-97668, Fire Endurance Test of Ceiling Assembly Clad W/Thermo-Lag 330-1.
| author name = HUMPHREY C A, PRIEST D N, STANSBERRY H W
| author name = Humphrey C, Priest D, Stansberry H
| author affiliation = OMEGA POINT LABORATORIES
| author affiliation = OMEGA POINT LABORATORIES
| addressee name =  
| addressee name =  
Line 35: Line 36:
| number = ML18012A879
| number = ML18012A879
| issue date = 11/10/1994
| issue date = 11/10/1994
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| title = Rev 0 to 14980-97261, Fire Endurance Test of Wall Assembly Clad w/Thermo-Lag 330-1.
| author name = HUMPHREY C A, PRIEST D N
| author name = Humphrey C, Priest D
| author affiliation = OMEGA POINT LABORATORIES
| author affiliation = OMEGA POINT LABORATORIES
| addressee name =  
| addressee name =  
Line 51: Line 52:
| issue date = 08/29/1997
| issue date = 08/29/1997
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| title = Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
| author name = ROBINSON W R
| author name = Robinson W
| author affiliation = CAROLINA POWER & LIGHT CO.
| author affiliation = CAROLINA POWER & LIGHT CO.
| addressee name =  
| addressee name =  

Latest revision as of 16:34, 6 March 2020

Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
Date released: 08/31/2018 Download: ML18012A878


Rev 0 to 14980-98207, Fire Endurance Test of Wall Assembly Clad w/Thermo-Lag 330-1.
ML18012A881
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 08/01/1995
From: Humphrey C, Stansberry H
OMEGA POINT LABORATORIES
To:
References
Download: ML18012A881 (162)
Rev 0 to 14980-97668, Fire Endurance Test of Ceiling Assembly Clad W/Thermo-Lag 330-1.
ML18012A880
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 05/30/1995
From: Humphrey C, Priest D, Stansberry H
OMEGA POINT LABORATORIES
To:
References
Download: ML18012A880 (17)
Rev 0 to 14980-97261, Fire Endurance Test of Wall Assembly Clad w/Thermo-Lag 330-1.
ML18012A879
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 11/10/1994
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML18012A879 (21)
Provides Closeout Documentation Harris Nuclear Plant Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Plant Will Restore Thermo-Lag Barrier Configurations to Svc & Discontinue Compensatory Actions Accordingly
ML18012A877
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 08/29/1997
From: Robinson W
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18012A877 (16)