Line 2: Line 2:
| number = ML082830031
| number = ML082830031
| issue date = 07/22/2008
| issue date = 07/22/2008
| title = Quad Cities, Units 1 & 2, License Amendment, Modify Technical Specification Requirements Related to Turbine Condenser Vacuum - Low Scram Instrumentation Setpoint.-TS Page
| title = License Amendment, Modify Technical Specification Requirements Related to Turbine Condenser Vacuum - Low Scram Instrumentation Setpoint.-TS Page
| author name =  
| author name =  
| author affiliation = NRC/NRR/DORL
| author affiliation = NRC/NRR/DORL
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:RPS Instrumentaation  
{{#Wiki_filter:RPS Instrumentaation     .
.3.3. ..Table 3.3.1.1-1 (page 3 of 3)Reactor Protection System Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION 0.1 REQUIREMENTS VALUE 7. Scram Discharge Volume Water Level High a. Float Switch 1,2 2 2 G SSR SR SR SR SR SR SR SR b. Differential Pressure Switch 1,2 5W)2 8. Turbine-Stop Valve-Closure
3.3. ..
: 9. Turbine Control Valve Fast Closure, Trip Oil Pressure-Low
Table 3.3.1.1-1 (page 3 of 3)
: 10. Turbine Condenser Vacuum-Low
Reactor Protection System Instrumentation APPLICABLE                   CONDITIONS MODES OR       REQUIRED   REFERENCED OTHER       CHANNELS       FROM SPECIFIED       PER TRIP     REQUIRED       SURVEILLANCE           ALLOWABLE FUNCTION                   CONDITIONS       SYSTEM     ACTION 0.1     REQUIREMENTS             VALUE
: 11. Reactor Mode Switch-Shutdown Position 38.5%RTP 38.5%RVP G SR SR SR SR SR H SR SR SR SR SR E SR SR SR SR SR SR E SSR SR SR SR S R SR 3.3.1.1.5 3.3.1.1.10 3.3.1 .1 .16 3.3.1.1. 17 3.3.1.1.5 3.3.1.1. 10 3.3.1.I.16 3.3.1.1. 17 3.3.1 .1.5 3.3.1 .1. 10 3.3.1 .1.11 3.3.1 .1 .16 3.3.1.1. 17 3.ý3 .1.,1.5 3.3.1.1.10 3.3.1 .1.11 3.3.1 .1. 16 3.3.1.1.17 3.3.1.1.5 3.3,1. .I10 3.3,1.1.13 3.3,1 .1 .16 3.3.1.1I.
: 7. Scram Discharge Volume Water   Level   High
17 3.3.1.1, 18 3,3.1.1.5 3.3.1.1.10 3.3.1. 1. 13 3.3.1.1. 16 3.3.1.1. 17 3.3. 1. 1. 18 3.3.1 .1.5 3.3.1.1. 10 3.3.1.1.12 3.3.1 .1.17 3.3.1.1.18
: a. Float Switch                       1,2           2           G       SSR 3.3.1.1.5         !5 38.9 gaI Ions SR  3.3.1.1.10 SR  3.3.1 .1 . 16 SR  3.3.1.1. 17 2                    SR  3.3.1.1.5       5 38.9 gallons SR  3.3.1.1. 10 SR  3.3.1.I.16 SR  3.3.1.1. 17
!5 38.9 gaI Ions 5 38.9 gallons< 32.3 gallons 32.3 gallons 5 9.7% closed Z 475 psig 20.6 inches Hg vacuum 2 SR SR SR SR SR 1,2 G SR 3.3.1.1.15 SR 3.3.1.1.17 b , SR 3.3.1.1.15 SR 3.3.1.1.17 NA NA NA NA 12. Manual Scram 1,2 G SR 3.3.1.1.8 SR 3.3.1.1.17 SR 3.3.1.1:8 SR 3.3.1.1.17 a) With anr cton !.r! rode ;i thdrawn from' a, tore ce J containi ng one or more fuel assemblies.
: b. Differential                      1,2                        G      SR  3.3.1 .1.5       < 32.3 gallons Pressure Switch                                                        SR  3.3.1 .1. 10 SR  3.3.1 .1.11 SR  3.3.1 .1 . 16 SR  3.3.1.1. 17 5W)            2            H      SR  3.&#xfd;3.1.,1.5         32.3 gallons SR  3.3.1.1.10 SR  3.3.1 .1.11 SR  3.3.1 .1. 16 SR  3.3.1.1.17
Quad Cities I and 2 3.3,.]1.1-9 Amendment No. 239 / 234}}
: 8. Turbine-Stop                        38.5%                          E      SR  3.3.1.1.5         5 9.7% closed Valve-Closure                        RTP                                    SR  3.3,1. .I10 SR  3.3,1.1.13 SR  3.3,1 .1 . 16 SR  3.3.1.1I. 17 SR  3.3.1.1, 18
: 9. Turbine Control Valve                38.5%                          E      SSR 3,3.1.1.5         Z 475  psig Fast Closure, Trip Oil              RVP                                    SR  3.3.1.1.10 Pressure-Low                                                                SR  3.3.1. 1. 13 SR  3.3.1.1. 16 SR  3.3.1.1. 17 SR  3.3. 1. 1. 18
: 10. Turbine Condenser                                      2                    SR  3.3.1 .1.5           20.6 inches Vacuum-Low                                                                  SR  3.3.1.1. 10       Hg vacuum SR  3.3.1.1.12 SR  3.3.1 .1.17 SR  3.3.1.1.18
: 11. Reactor Mode Switch-                  1,2                         G       SR 3.3.1.1.15       NA Shutdown Position                                                          SR 3.3.1.1.17 b,                                   SR 3.3.1.1.15       NA SR 3.3.1.1.17
: 12. Manual   Scram                         1,2                         G       SR 3.3.1.1.8         NA SR 3.3.1.1.17 SR 3.3.1.1:8         NA SR 3.3.1.1.17 a)   With anr   cton !.r! rode ;i thdrawn from' a, tore ce J containi ng one or more fuel assemblies.
Quad Cities I and 2                                         3.3,.]1.1-9                             Amendment No. 239 / 234}}

Latest revision as of 13:15, 14 November 2019

License Amendment, Modify Technical Specification Requirements Related to Turbine Condenser Vacuum - Low Scram Instrumentation Setpoint.-TS Page
ML082830031
Person / Time
Site: Dresden, Quad Cities  Constellation icon.png
Issue date: 07/22/2008
From:
Division of Operating Reactor Licensing
To:
Wiebe, Joel NRR/DORL/LPL3-2, 415-6606
Shared Package
ML081700415 List:
References
TAC MD6250, TAC MD6251, TAC MD6252, TAC MD6253
Download: ML082830031 (1)


Text

RPS Instrumentaation .

3.3. ..

Table 3.3.1.1-1 (page 3 of 3)

Reactor Protection System Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION 0.1 REQUIREMENTS VALUE

7. Scram Discharge Volume Water Level High
a. Float Switch 1,2 2 G SSR 3.3.1.1.5 !5 38.9 gaI Ions SR 3.3.1.1.10 SR 3.3.1 .1 . 16 SR 3.3.1.1. 17 2 SR 3.3.1.1.5 5 38.9 gallons SR 3.3.1.1. 10 SR 3.3.1.I.16 SR 3.3.1.1. 17
b. Differential 1,2 G SR 3.3.1 .1.5 < 32.3 gallons Pressure Switch SR 3.3.1 .1. 10 SR 3.3.1 .1.11 SR 3.3.1 .1 . 16 SR 3.3.1.1. 17 5W) 2 H SR 3.ý3.1.,1.5 32.3 gallons SR 3.3.1.1.10 SR 3.3.1 .1.11 SR 3.3.1 .1. 16 SR 3.3.1.1.17
8. Turbine-Stop 38.5% E SR 3.3.1.1.5 5 9.7% closed Valve-Closure RTP SR 3.3,1. .I10 SR 3.3,1.1.13 SR 3.3,1 .1 . 16 SR 3.3.1.1I. 17 SR 3.3.1.1, 18
9. Turbine Control Valve 38.5% E SSR 3,3.1.1.5 Z 475 psig Fast Closure, Trip Oil RVP SR 3.3.1.1.10 Pressure-Low SR 3.3.1. 1. 13 SR 3.3.1.1. 16 SR 3.3.1.1. 17 SR 3.3. 1. 1. 18
10. Turbine Condenser 2 SR 3.3.1 .1.5 20.6 inches Vacuum-Low SR 3.3.1.1. 10 Hg vacuum SR 3.3.1.1.12 SR 3.3.1 .1.17 SR 3.3.1.1.18
11. Reactor Mode Switch- 1,2 G SR 3.3.1.1.15 NA Shutdown Position SR 3.3.1.1.17 b, SR 3.3.1.1.15 NA SR 3.3.1.1.17
12. Manual Scram 1,2 G SR 3.3.1.1.8 NA SR 3.3.1.1.17 SR 3.3.1.1:8 NA SR 3.3.1.1.17 a) With anr cton !.r! rode ;i thdrawn from' a, tore ce J containi ng one or more fuel assemblies.