{{#Wiki_filter:RAS Ew4S%UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of ENTERGY NUCLEAR OPERATIONS, INC.(Indian Point Nuclear Generating Units 2 and 3))))))Docket Nos.50-247-LR and 50-286-LR) February 18, 2011 APPLICANT'S ANSWER TO HUDSON RIVER SLOOP CLEARWATER, INC. AND RIVERKEEPER, INC.'S NEW CONTENTIONS CONCERNING THE WASTE CONFIDENCE RULE William C. Dennis, Esq.Entergy Nuclear Operations, Inc.440 Hamilton Avenue White Plains, NY 10601 Phone: (914) 272-3202 Fax: (914) 272-3205 E-mail: wdennis@entergy.com DOCKETED February 18, 2011 (4:53 p.m.)Kathryn M. Sutton, Esq.Paul M
{{#Wiki_filter:RAS Ew4S%
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of                                    )      Docket Nos. 50-247-LR and
                                                      )                    50-286-LR ENTERGY NUCLEAR OPERATIONS, INC.                    )
                                                      )
(Indian Point Nuclear Generating Units 2 and 3)      )
                                                      )      February 18, 2011 APPLICANT'S ANSWER TO HUDSON RIVER SLOOP CLEARWATER, INC. AND RIVERKEEPER, INC.'S NEW CONTENTIONS CONCERNING THE WASTE CONFIDENCE RULE William C. Dennis, Esq.                      Kathryn M. Sutton, Esq.
Entergy Nuclear Operations, Inc.            Paul M. Bessette, Esq.
440 Hamilton Avenue                          MORGAN, LEWIS & BOCKIUS LLP White Plains, NY 10601                      1111 Pennsylvania Avenue, N.W.
Phone: (914) 272-3202                        Washington, D.C. 20004 Fax: (914) 272-3205                          Phone: (202) 739-5738 E-mail: wdennis@entergy.com                  E-mail: ksutton@morganlewis.com E-mail: pbessette@morganlewis.com Martin J. O'Neill,
1o5 See Nuclear Mgmt. Co. (Palisades Nuclear Plant), CLI-06-17, 63 NRC 727, 733 (2006); Oconee, CLI-99-1I, 49 NRC at 344 n.4 ("the Commission handles as a separate licensing matter [from license renewal] any applications for an onsite ISFSI. ISFSI licenses are granted under 10 C.F.R. Part 72").
1o5 See Nuclear Mgmt. Co. (Palisades Nuclear Plant), CLI-06-17, 63 NRC 727, 733 (2006); Oconee, CLI-99-1I, 49 NRC at 344 n.4 ("the Commission handles as a separate licensing matter [from license renewal] any applications for an onsite ISFSI. ISFSI licenses are granted under 10 C.F.R. Part 72").
which is licensed pursuant to 10 C.F.R. Part 72. Issues involving the ISFSI are, quite simply, separate licensing matters.1 0 6 Thus, because the IPEC ISFSI is licensed pursuant to 10 C.F.R. § 72.212 (as was the ISFSI in the Palisades proceeding), such matters are beyond the scope of this proceeding.
 
Accordingly, Petitioners' challenge to the aging management of the spent fuel storage casks are not within the scope of the proceeding, as required by 10 C.F.R. § 2.309(f)(1)(iii).
which is licensed pursuant to 10 C.F.R. Part 72. Issues                   10 6 involving the ISFSI are, quite       simply,   separate     licensing   matters.
: 4. Clearwater SC-2 (Riverkeeper TC-3) Raises No Genuine Dispute Regarding Enter-a 's Spent Fuel Pool AMPs, As Required By 10 C.F.R. .' 2. 309(t)(1)(vi)
Thus, because the IPEC ISFSI is licensed pursuant to 10 C.F.R. § 72.212 (as was the ISFSI in the Palisades proceeding), such matters are beyond the scope of this proceeding.                                         Accordingly, Petitioners' challenge to the aging management of the spent fuel storage casks are not within the scope of the proceeding, as required by 10 C.F.R. § 2.309(f)(1)(iii).
CW SC-2/RK TC-3 also alleges that the LRA contains an "insufficient analysis of the aging management of the ... spent fuel pools."''0 7 In order to support such a challenge, the Commission has stated that a petitioner must "read the pertinent portions of the license application,...
: 4.         ClearwaterSC-2 (Riverkeeper TC-3) Raises No Genuine Dispute Regarding Enter-a 's Spent Fuel Pool AMPs, As Required By 10 C.F.R. .' 2. 309(t)(1)(vi)
state the applicant's position and the petitioner's opposing view," and explain why it disagrees with the applicant.'
CW SC-2/RK TC-3 also alleges that the LRA contains an "insufficient analysis of the aging management of the ...                   spent fuel pools."'' 07 In order to support such a challenge, the Commission has stated that a petitioner must "read the pertinent portions of the license application,... state the applicant's position and the petitioner's opposing view," and explain why it disagrees with the applicant.' 0 8 Thus, a contention that does not directly controvert a position taken by the applicant in the application is subject to dismissal. 109 CW SC-2/RK TC-3 is inadmissible because the LRA contains AMPs related to the spent fuel pools.             Specifically, Entergy's LRA includes AMPs for spent fuel pool structural components, including liner plates and gates;I10 concrete structures, including floor slabs, interior walls, and ceilings;"'1 spent fuel storage racks;11 2 and neutron absorbers." 3                                     By failing to challenge or even reference any of these AMPs, Clearwater fails to directly controvert the LRA.
0 8 Thus, a contention that does not directly controvert a position taken by the applicant in the application is subject to dismissal.
106     Palisades,CLI-06-17, 63 NRC at 733 (citation. omitted). See also 10 C.F.R. § 72.212(a) (permitting general ISFSI licensees to store spent fuel in approved casks for up to 20 years, a period which can be extended through reapproval).
1 0 9 CW SC-2/RK TC-3 is inadmissible because the LRA contains AMPs related to the spent fuel pools. Specifically, Entergy's LRA includes AMPs for spent fuel pool structural components, including liner plates and gates;I1 0 concrete structures, including floor slabs, interior walls, and ceilings;"'1 spent fuel storage racks;11 2 and neutron absorbers." 3 By failing to challenge or even reference any of these AMPs, Clearwater fails to directly controvert the LRA.106 Palisades, CLI-06-17, 63 NRC at 733 (citation.
107     New Contentions at 18 (emphasis added).
omitted).
108     Final Rule, Rules of Practice for Domestic Licensing Proceedings-Procedural Changes in the Hearing Process, 54 Fed.
See also 10 C.F.R. § 72.212(a) (permitting general ISFSI licensees to store spent fuel in approved casks for up to 20 years, a period which can be extended through reapproval).
Reg. 33,168, 33,170 (Aug. 11, 1989); Millstone, CLI-01-24, 54 NRC at 358.
107 New Contentions at 18 (emphasis added).108 Final Rule, Rules of Practice for Domestic Licensing Proceedings-Procedural Changes in the Hearing Process, 54 Fed.Reg. 33,168, 33,170 (Aug. 11, 1989); Millstone, CLI-01-24, 54 NRC at 358.109 See Oconee, CLI-99-11,49 NRC at 342.10 LRA Table 3.5.2-3.III /d.112 id.113 Id. Tables 3.3.2-1-IP2, 3.3.2-1-IP3.
109     See Oconee, CLI-99-11,49 NRC at 342.
10     LRA Table 3.5.2-3.
III /d.
112     id.
113     Id. Tables 3.3.2-1-IP2, 3.3.2-1-IP3.
 
CW SC-2/RK TC-3 is similar to the Town of Cortlandt's earlier attempt to challenge AMPs for spent fuel pools. The Board correctly rejected this proposed contention and explained:
CW SC-2/RK TC-3 is similar to the Town of Cortlandt's earlier attempt to challenge AMPs for spent fuel pools. The Board correctly rejected this proposed contention and explained:
Cortlandt contends that Entergy has not submitted an AMP which provides reasonable assurance that SSCs associated with the storage, control, and maintenance of spent fuel will remain capable of fulfilling their intended functions during the proposed extended period of operation.
Cortlandt contends that Entergy has not submitted an AMP which provides reasonable assurance that SSCs associated with the storage, control, and maintenance of spent fuel will remain capable of fulfilling their intended functions during the proposed extended period of operation. However, Cortlandt offers no analysis of the AMPs included in the LRA, nor does it explain in any way how those plans are deficient. . . . The LRA, however, does include AMPs for spent fuel structural components, and Cortlandt does not discuss or even identify any alleged deficiency with these plans.
However, Cortlandt offers no analysis of the AMPs included in the LRA, nor does it explain in any way how those plans are deficient.  
                        . . . . In this proceeding, Cortlandt must identify specific deficiencies   in the AMP in order to secure a hearing on the 114 issue.
...The LRA, however, does include AMPs for spent fuel structural components, and Cortlandt does not discuss or even identify any alleged deficiency with these plans.....In this proceeding, Cortlandt must identify specific deficiencies in the AMP in order to secure a hearing on the issue. 1 1 4 Similarly, Petitioners fail to identify any specific deficiencies in the AMPs, and thus fails to raise a genuine dispute on a material issue of law or fact, as required by 10 C.F.R. § 2.309(f)(1)(vi).
Similarly, Petitioners fail to identify any specific deficiencies in the AMPs, and thus fails to raise a genuine dispute on a material issue of law or fact, as required by 10 C.F.R. § 2.309(f)(1)(vi).
C. Clearwater EC-9 (Riverkeeper EC-7) and Clearwater SC-3 (Riverkeeper TC-4) Do Not Cure the Defects in Petitioners' First Set of Contentions Recognizing the defects in their first set of proposed contentions, Petitioners proffer two additional contentions intended to cover their "rule valid" scenario.115 Both alternative contentions, CW EC-9/RK EC-7 and CW SC-3/RK TC-4, essentially address the same purported environmental and safety issues raised in CW EC-8/RK EC-6 and CW SC-2/RK TC-3, respectively.11 6 The difference for these contentions is that Petitioners focus on the period commencing 60 years after the date that the license will expire for each IPEC unit.1 1 7 114 Indian Point, LBP-08-13, 68 NRC at 211-12.115 New Contentions at 18. Petitioners refer to their first two contentions as covering the "rule invalid" scenario.
C.       Clearwater EC-9 (Riverkeeper EC-7) and Clearwater SC-3 (Riverkeeper TC-4) Do Not Cure the Defects in Petitioners' First Set of Contentions Recognizing the defects in their first set of proposed contentions, Petitioners proffer two additional contentions intended to cover their "rule valid" scenario.115                                       Both alternative contentions, CW EC-9/RK EC-7 and CW SC-3/RK TC-4, essentially address the same purported environmental and safety issues raised in CW EC-8/RK EC-6 and CW SC-2/RK TC-3, respectively.11 6 The difference for these contentions is that Petitioners focus on the period 117 commencing 60 years after the date that the license will expire for each IPEC unit.
Id. at 17.116 See id. at 17-18.117 See, e.g., id. at 33.
114   Indian Point, LBP-08-13, 68 NRC at 211-12.
: 1. Petitioners  
115   New Contentions at 18. Petitioners refer to their first two contentions as covering the "rule invalid" scenario. Id. at 17.
'Alternative Contentions Suffer From the Same Deliciencies-As the.Initial Set Both of these alternative contentions suffer from the same deficiencies as the initial set of contentions.
116   See id. at 17-18.
Importantly, the limited supporting information Petitioners provide does not.distinguish between the initial set of safety and environmental contentions and this "alternative" set and therefore, the alternatives are inadmissible for the reasons set forth in response to CW EC-9/RK EC-7 and CW SC-3/RK TC-4, above. Specifically, in the case of CW EC-9/RK EC-7, Petitioners' claims are barred by CLI-10-19, because they impermissibly challenge the amended Waste Confidence Rule, seek to raise NEPA-terrorism claims that are similarly outside the scope of this proceeding, and fail to raise a genuine dispute with the FSEIS." 8 As to CW SC-3/RK TC-4, Petitioners' claims are untimely, equally barred by CLI-10-19, fail to adequately state the issues raised, fail to provide basis or support for the contention, raise issues beyond the scope of this proceeding, and fail to raise a genuine dispute."1 9 2. There Is No Regulatory Gap Regarding Impacts More than 60 Years Beyond Licensed Life, and to the Extent Any Perceived Gap May Exist, It Is the Subject of An Ongoing' Commission Rulemaking Petitioners assert that under amended Waste Confidence Rule, "the Commission's generic findings with respect to onsite fuel storage in both wet pools and dry casks relate only to the period 60 years beyond the expiration of a plant's operating license."'
117   See, e.g., id. at 33.
2 0  Based on this, Petitioners assert that CW EC-9/RK EC-7 and CW SC-3/RK TC-4--which seek to.litigate 118 See Section IV.A, above.119 See Section IV.B, above.120 New Contentions at 33 (citing 75 Fed. Reg. at 81,033, 81,040). New York echoes these claims in its answer. See New York Answer at 18-22. The key case cited by New York is Natural Resources Def Council, Inc. v. NRC, 539 F.2d 824 (2d Cir. 1976), vacated & remanded, sub nom. Allied-Gen.
: 1.         Petitioners'Alternative Contentions Suffer From the Same Deliciencies-As the
Nuclear Servs. v. Natural Res. Def Council, 434 U.S. 1030 (1978).In that case, all parties conceded that the draft generic environmental impact statement at issue did not properly address all of the environmental impacts the proposed action. See id. at 842 ("it is apparent that [the draft generic EIS] did not fully address alternatives to plutonium recycle or the special problems of theft, diversion and sabotage").
                    . InitialSet Both of these alternative contentions suffer from the same deficiencies as the initial set of contentions.         Importantly, the limited supporting information Petitioners provide does not
The Waste Confidence Rule, however, does address the environmental impacts of spent fuel storage, and the Commission's conclusion in that regard is not subject to challenge in this proceeding.
.distinguish between the initial set of safety and environmental contentions and this "alternative" set and therefore, the alternatives are inadmissible for the reasons set forth in response to CW EC-9/RK EC-7 and CW SC-3/RK TC-4, above. Specifically, in the case of CW EC-9/RK EC-7, Petitioners' claims are barred by CLI-10-19, because they impermissibly challenge the amended Waste Confidence Rule, seek to raise NEPA-terrorism claims that are similarly outside the scope of this proceeding, and fail to raise a genuine dispute with the FSEIS." 8 As to CW SC-3/RK TC-4, Petitioners' claims are untimely, equally barred by CLI-10-19, fail to adequately state the issues raised, fail to provide basis or support for the contention, raise issues beyond the scope of 9
* environmental and safety issues that relate to the "period commencing 60 years after" the end of the period of extended operation'21-are within the scope of this proceeding.1 2 2  In effect, Petitioners claim that there is an apparent regulatory gap because impacts beyond 60 years have not been analyzed by this Commission.
this proceeding, and fail to raise a genuine dispute."1
As a threshold matter, of course, this Part 54 proceeding governs license renewal, including the environmental impacts associated with continued operation for only an additional 20 years (i.e., until 2033 for IP2 and 2035 for IP3). The environmental impacts of spent fuel storage beyond 2093 or 2095 are beyond the scope of this proceeding.
: 2.         There Is No Regulatory Gap RegardingImpacts More than 60 Years Beyond Licensed Life, and to the Extent Any Perceived Gap May Exist, It Is the Subject of An Ongoing'Commission Rulemaking Petitioners assert that under amended Waste Confidence Rule, "the Commission's generic findings with respect to onsite fuel storage in both wet pools and dry casks relate only to the period 60 years beyond the expiration of a plant's operating license."' 20 Based on this, Petitioners assert that CW EC-9/RK EC-7 and CW SC-3/RK TC-4--which seek to.litigate 118   See Section IV.A, above.
1 2 3 Moreover, there is no "regulatory gap." The plain text of the amended Section 51.23(a)states that spent fuel "can be stored safely and without significant environmental impacts for at least 60 years beyond licensed life for operation," and goes on to state the Commission's belief that sufficient repository capacity will be available "when necessary."'1 2 4  Read together, it is clear from the plain text of the rule that the existing analysis, which extends to at least 60 years beyond the licensed life for operation, is sufficient to address the impacts of spent fuel storage.1 2 5 With respect to future actions:[T]he Commission has confidence that either a repository will be available before the expiration of the 60 years post-licensed life discussed in Finding 4 or that the Waste Confidence Decision and Rule will be updated and revised if the expiration of the 60-year 121 New Contentions at 18.122 See id. at 20 ("Petitioners have presented alternative contentions that are valid, even if the rules established by the [2010 Waste Confidence Decision]
119   See Section IV.B, above.
are valid.").123 New York suggests that the NRC Staff's Safety Evaluation Report ("SER') is required, under the Atomic Energy Act ("AEA") (42 U.S.C. § 2232(a), to make a definitive finding that storing spent fuel at IPEC for more than 60 years "is safe and can be done with adequate protection for the public health and safety. New York Answer at 15. This is incorrect.
120   New Contentions at 33 (citing 75 Fed. Reg. at 81,033, 81,040). New York echoes these claims in its answer. See New York Answer at 18-22. The key case cited by New York is NaturalResources Def Council,Inc. v. NRC, 539 F.2d 824 (2d Cir. 1976), vacated & remanded,sub nom. Allied-Gen. NuclearServs. v. NaturalRes. Def Council, 434 U.S. 1030 (1978).
See Natural Res. Def Council v. NRC, 582 F.2d 166, 175 (2d Cir. 1978) (holding that under the AEA, "NRC is not required...
In that case, all parties conceded that the draft generic environmental impact statement at issue did not properly address all of the environmental impacts the proposed action. See id. at 842 ("it is apparent that [the draft generic EIS] did not fully address alternatives to plutonium recycle or the special problems of theft, diversion and sabotage"). The Waste Confidence Rule, however, does address the environmental impacts of spent fuel storage, and the Commission's conclusion in that regard is not subject to challenge in this proceeding.
to withhold action on pending or future applications for nuclear power reactor operating licenses until it makes a determination that high-level radioactive wastes can be permanently disposed of safely").124 Emphasis added.125 And as the Commission has previously explained, "the Court decision that led to the Waste Confidence Proceeding did not require NRC to determine when a repository would be available." Review and Final Revision of Waste Confidence Decision, 55 Fed. Reg. 38,474, 38,477 (Sept. 18, 1990) (citing Minnesota
* environmental and safety issues that relate to the "period commencing 60 years after" the end of the period of extended operation'21-are within the scope of this proceeding.122 In effect, Petitioners claim that there is an apparent regulatory gap because impacts beyond 60 years have not been analyzed by this Commission.
: v. NRC, 602 F.2d 412 (DC Cir. 1979)).
As a threshold matter, of course, this Part 54 proceeding governs license renewal, including the environmental impacts associated with continued operation for only an additional 20 years (i.e., until 2033 for IP2 and 2035 for IP3). The environmental impacts of spent fuel 23 storage beyond 2093 or 2095 are beyond the scope of this proceeding. 1 Moreover, there is no "regulatory gap." The plain text of the amended Section 51.23(a) states that spent fuel "can be stored safely and without significant environmental impacts for at least 60 years beyond licensed life for operation," and goes on to state the Commission's belief that sufficient repository capacity will be available "when necessary."'124 Read together, it is clear from the plain text of the rule that the existing analysis, which extends to at least 60 years 25 beyond the licensed life for operation, is sufficient to address the impacts of spent fuel storage.1 With respect to future actions:
period approaches without an ultimate disposal solution for the HLW and SNF.'2 6 Thus, contrary to Clearwater and Riverkeeper's contentions, there is simply no regulatory gap beyond 60 years after plant shutdown.
[T]he Commission has confidence that either a repository will be available before the expiration of the 60 years post-licensed life discussed in Finding 4 or that the Waste Confidence Decision and Rule will be updated and revised if the expiration of the 60-year 121   New Contentions at 18.
The Commission has already held that if it becomes necessary to conduct this evaluation, it has sufficient time to do so over the next 80 years or more.The NRC has in fact already initiated this evaluation, again following its previous generic approach.
122   See id. at 20 ("Petitioners have presented alternative contentions that are valid, even if the rules established by the [2010 Waste Confidence Decision] are valid.").
As explained in the 2010 Waste Confidence Decision, The Commission, as a separate action, has directed the staff to develop a plan for a longer-term rulemaking and Environmental Impact Statement (EIS) to assess the environmental impacts and safety of long-term SNF and HLW storage beyond 120 years (SRM-SECY-09-0090; ADAMS Accession Number ML102580229).
123   New York suggests that the NRC Staff's Safety Evaluation Report ("SER') is required, under the Atomic Energy Act
This analysis will go well beyond the current analysis that supports at least 60 years of post-licensed life storage with eventual disposal in a deep geologic repository.
("AEA") (42 U.S.C. § 2232(a), to make a definitive finding that storing spent fuel at IPEC for more than 60 years "is safe and can be done with adequate protection for the public health and safety. New York Answer at 15. This is incorrect. See NaturalRes. Def Council v. NRC, 582 F.2d 166, 175 (2d Cir. 1978) (holding that under the AEA, "NRC is not required...
127 In other words, the long-term environmental impacts of long-term spent fuel storage, well beyond the term covered by the amended Waste Confidence Rule, is now the subject of a Commission rulemaking initiative.
to withhold action on pending or future applications for nuclear power reactor operating licenses until it makes a determination that high-level radioactive wastes can be permanently disposed of safely").
As the Commission recently reiterated in this proceeding,"[u]nder longstanding NRC policy, licensing boards 'should not accept in individual license proceedings contentions which are (or are about to become) the subject of general rulemaking by the Commission.""1 2 8 Thus, Petitioners' desire to litigate its perceived gap in the new 10 C.F.R.§ 51.23(a) is well outside the scope of this proceeding and must be dismissed.
124   Emphasis added.
126 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,043 (emphasis added).127 Id. at 81,040 (emphasis added).128 CLI-10-19, slip op. at 2-3 (quoting Oconee, CLI-99,1 1,49 NRC at 345) (emphasis added). In Oconee, the Commission held that, although the topic petitioners sought to raise was not governed by a current rule, the issuance of a Staff Requirements Memorandum
125   And as the Commission has previously explained, "the Court decision that led to the Waste Confidence Proceeding did not require NRC to determine when a repository would be available." Review and Final Revision of Waste Confidence Decision, 55 Fed. Reg. 38,474, 38,477 (Sept. 18, 1990) (citingMinnesota v. NRC, 602 F.2d 412 (DC Cir. 1979)).
("SRM") for the NRC Staff to initiate a rulemaking on the topic was sufficient to preclude the topic from litigation in individual licensing proceedings.
 
See 49 NRC at 345-56. The rulemaking on the very long-term impacts of spent fuel storage is currently at the same stage. See 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,040.
period approaches without an ultimate disposal solution for the HLW and SNF.' 26 Thus, contrary to Clearwater and Riverkeeper's contentions, there is simply no regulatory gap beyond 60 years after plant shutdown. The Commission has already held that if it becomes necessary to conduct this evaluation, it has sufficient time to do so over the next 80 years or more.
The NRC has in fact already initiated this evaluation, again following its previous generic approach. As explained in the 2010 Waste Confidence Decision, The Commission, as a separate action, has directed the staff to develop a plan for a longer-term rulemaking and Environmental Impact Statement (EIS) to assess the environmental impacts and safety of long-term SNF and HLW storage beyond 120 years (SRM-SECY-09-0090;                     ADAMS             Accession             Number ML102580229). This analysis will go well beyond the current analysis that supports at least 60 years of post-licensed life storage with eventual disposal in a deep geologic repository. 127 In other words, the long-term environmental impacts of long-term spent fuel storage, well beyond the term covered by the amended Waste Confidence Rule, is now the subject of a Commission rulemaking initiative. As the Commission recently reiterated in this proceeding,
"[u]nder longstanding NRC policy, licensing boards 'should not accept in individual license proceedings contentions which are (or are about to become) the subject of general rulemaking by the Commission.""1 28 Thus, Petitioners' desire to litigate its perceived gap in the new 10 C.F.R.
§ 51.23(a) is well outside the scope of this proceeding and must be dismissed.
126 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,043 (emphasis added).
127 Id. at 81,040 (emphasis added).
128 CLI-10-19, slip op. at 2-3 (quoting Oconee, CLI-99,1 1,49 NRC at 345) (emphasis added). In Oconee, the Commission held that, although the topic petitioners sought to raise was not governed by a current rule, the issuance of a Staff Requirements Memorandum ("SRM") for the NRC Staff to initiate a rulemaking on the topic was sufficient to preclude the topic from litigation in individual licensing proceedings. See 49 NRC at 345-56. The rulemaking on the very long-term impacts of spent fuel storage is currently at the same stage. See 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,040.
 
Accordingly, for this additional reason CW EC-9/RK EC-7 and CW SC-3/RK TC-4 are outside the scope of this proceeding and must be dismissed.
Accordingly, for this additional reason CW EC-9/RK EC-7 and CW SC-3/RK TC-4 are outside the scope of this proceeding and must be dismissed.
V. CONCLUSION For the reasons set forth above, Clearwater and Riverkeeper's new contentions are inadmissible and should be dismissed in their entirety.CERTIFICATION OF COUNSEL UNDER 10 C.F.R. § 2.323(b)Counsel for Entergy certifies that he has made a sincere effort to make himself available to listen and respond to the moving parties, and to resolve the factual and legal issues raised in the motion, and that his efforts to resolve the issues have been unsuccessful.
V.     CONCLUSION For the reasons set forth above, Clearwater and Riverkeeper's new contentions are inadmissible and should be dismissed in their entirety.
William C. Dennis, Esq.Entergy Nuclear Operations, Inc.440 Hamilton Avenue White Plains, NY 10601 Phone: (914) 272-3202 Fax: (914) 272-3205 E-mail: wdennis@entergy.com Resp tfulysbitd Kathryn M. Sutton, Esq.Paul M. Bessette, Esq.Martin J. O'Neill, Esq.MORGAN, LEWIS & BOCKIUS LLP 1111 Pennsylvania Avenue, N.W.Washington, D.C. 20004 Phone: (202) 739-5738 Fax: (202) 739-3001 E-mail: ksutton@morganlewis.com E-mail: pbessette@morganlewis.com E-mail: martin.oneill@morganlewis.
CERTIFICATION OF COUNSEL UNDER 10 C.F.R. § 2.323(b)
com COUNSEL FOR ENTERGY NUCLEAR OPERATIONS, INC.Dated in Washington, D.C.this 18th day of February 2011 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of ENTERGY NUCLEAR OPERATIONS, INC.(Indian Point Nuclear Generating Units 2 and 3).))))Docket Nos. 50-247-LR and 50-286-LR) February 18, 2011 CERTIFICATE OF SERVICE I hereby certify that copies of the "Applicant's Answer to Hudson River Sloop Clearwater, Inc.and Riverkeeper, Inc.'s New Contentions Concerning the Waste Confidence Rule" were served this 18th day of February, 201.1 upon the persons listed below, by first class mail and e-mail as shown below.Administrative Judge Lawrence G. McDade, Chair Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: lgrl (@nrc.gov)
Counsel for Entergy certifies that he has made a sincere effort to make himself available to listen and respond to the moving parties, and to resolve the factual and legal issues raised in the motion, and that his efforts to resolve the issues have been unsuccessful.
Administrative Judge Richard E. Wardwell Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: rew(d~nrc.gov)
Resp    tfulysbitd William C. Dennis, Esq.                         Kathryn M. Sutton, Esq.
Office of Commission Appellate Adjudication U.S. Nuclear Regulatory Commission Mail Stop: 0-16G4 Washington, DC 20555-0001 (E-mail: ocaamail(dnrc.gov)
Entergy Nuclear Operations, Inc.                Paul M. Bessette, Esq.
Administrative Judge Kaye D. Lathrop Atomic Safety and Licensing Board Panel 190 Cedar Lane E.Ridgway, CO 81432 (E-mail: kdl2(2nrc.gov)
440 Hamilton Avenue                            Martin J. O'Neill, Esq.
Office of the Secretary*
White Plains, NY 10601                          MORGAN, LEWIS & BOCKIUS LLP Phone: (914) 272-3202                            1111 Pennsylvania Avenue, N.W.
Attn: Rulemaking and Adjudications Staff U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 (E-mail: hearingdocket(&nrc.gov)
Fax: (914) 272-3205                            Washington, D.C. 20004 E-mail: wdennis@entergy.com                    Phone: (202) 739-5738 Fax: (202) 739-3001 E-mail: ksutton@morganlewis.com E-mail: pbessette@morganlewis.com E-mail: martin.oneill@morganlewis. com COUNSEL FOR ENTERGY NUCLEAR OPERATIONS, INC.
Josh Kirstein, Law Clerk Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: Josh.Kirstein(anrc.
Dated in Washington, D.C.
gov)
this 18th day of February 2011
Sherwin E. Turk, Esq.Beth N. Mizuno, Esq.David E. Roth, Esq.Brian G. Harris, Esq.Andrea Z. Jones, Esq.Office of the General Counsel Mail Stop: 0-15 D21 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: setanrc.gov)(E-mail: bnml (@nrc.gov)(E-mail: david.rothmnrc.gov)(E-mail: brian.harrisa~nrc.gov)(E-mail: andrea.ionesanrc.gov)
 
Manna Jo Greene, Environmental Director Stephen C. Filler, Board Member Hudson River Sloop Clearwater, Inc.11 2 Little Market Street Poughkeepsie, NY 12601 (E-mail: mannajo(@clearwater.org)(E-mail: sfiller(anylawline.com)
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of                                     .)      Docket Nos. 50-247-LR and
Joan Leary Matthews, Esq.Senior Attorney for Special Projects Office of the General Counsel New York State Department of Environmental Conservation 625 Broadway, 14th Floor Albany, NY 12207 (E-mail: jImatthe~gw.dec.state.ny.us)
                                                      )                      50-286-LR ENTERGY NUCLEAR OPERATIONS, INC.                     )
Ross Gould, Member Hudson River Sloop Clearwater, Inc.270 Route 308 Rhinebeck, NY 12572 (E-mail: rgouldesq0(gmail.com)
                                                      )
Melissa-Jean Rotini, Esq.Assistant County Attorney Office of Robert F. Meehan, Westchester County Attorney 148 Martine Avenue, 6th Floor White Plains, NY 10601 (E-mail: MJR 1 Thomas F. Wood, Esq.Daniel Riesel, Esq.Ms. Jessica Steinberg, J.D.Sive, Paget & Riesel, P.C.460 Park Avenue New York, NY 10022 (E-mail: drieselasprlaw.com)(E-mail: jsteinberg(@sprlaw.com)
(Indian Point Nuclear Generating Units 2 and 3)
John Louis Parker, Esq.Regional Attorney Office of General Counsel, Region 3 NYS Dept. of Environmental Conservation 21 S. Putt Comers Road New Paltz, New York 12561-1620 (E-mail: ilparker(agw.dec.state.nv.us)
                                                      )       February 18, 2011 CERTIFICATE OF SERVICE I hereby certify that copies of the "Applicant's Answer to Hudson River Sloop Clearwater, Inc.
Michael J. Delaney, V.P. -Energy New York City Economic Dev. Corp.110 William Street New York, NY 10038 (E-mail: mdelanevanycedc.com)
and Riverkeeper, Inc.'s New Contentions Concerning the Waste Confidence Rule" were served this 18th day of February, 201.1 upon the persons listed below, by first class mail and e-mail as shown below.
Phillip Musegaas, Esq.Deborah Brancato, Esq.Riverkeeper, Inc.20 Secor Road Ossining, NY 10562 (E-mail: phillipvriverkeeper.org)(E-mail: dbrancato(iriverkeeper.ora)
Administrative Judge                                  Administrative Judge Lawrence G. McDade, Chair                             Kaye D. Lathrop Atomic Safety and Licensing Board Panel                Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23                                     190 Cedar Lane E.
Robert D. Snook, Esq.Assistant Attorney General Office of the Attorney General State of Connecticut 55 Elm Street P.O. Box 120 Hartford, CT 06141-0120 (E-mail: Robert. Snook(po.state.ct.us)
U.S. Nuclear Regulatory Commission                     Ridgway, CO 81432 Washington, DC 20555-0001                             (E-mail: kdl2(2nrc.gov)
John J. Sipos, Esq.Charlie Donaldson Esq.Assistants Attorneys General Office of the Attorney General of the State of New York The Capitol Albany, NY 12224-0341 (E-mail: John.Sipos@iiag.n .gov)Daniel E. O'Neill, Mayor James Siermarco, M.S.Liaison to Indian Point Village of Buchanan Municipal Building 236 Tate Avenue Buchanan, NY 10511-1298 (E-mail: vobgbestweb.net)(E-mail: smurray(avillageofbuchanan.com)
(E-mail: lgrl (@nrc.gov)
Mylan L. Denerstein, Esq.Executive Deputy Attorney General, Social Justice Office of the Attorney General of the State of New York 120 Broadway, 25th Floor New York, New York 10271 (E-mail: Mylan.Denersteinaoag.state.ny.us)
Administrative Judge                                   Office of the Secretary*
Janice A. Dean, Esq.Assistant Attorney General Office of the Attorney General of the State of New York 120 Broadway, 26th Floor New York, New York 10271 (E-mail: Janice.Dean(ioag.state.ny.us)
Richard E. Wardwell                                   Attn: Rulemaking and Adjudications Staff Atomic Safety and Licensing Board Panel               U.S. Nuclear Regulatory Commission Mail Stop: T-3 F23                                     Washington, D.C. 20555-0001 U.S. Nuclear Regulatory Commission                     (E-mail: hearingdocket(&nrc.gov)
Washington, DC 20555-0001 (E-mail: rew(d~nrc.gov)
Office of Commission Appellate Adjudication           Josh Kirstein, Law Clerk U.S. Nuclear Regulatory Commission                   Atomic Safety and Licensing Board Panel Mail Stop: 0-16G4                                     Mail Stop: T-3 F23 Washington, DC 20555-0001                             U.S. Nuclear Regulatory Commission (E-mail: ocaamail(dnrc.gov)                           Washington, DC 20555-0001 (E-mail: Josh.Kirstein(anrc. gov)
 
Sherwin E. Turk, Esq.                       Melissa-Jean Rotini, Esq.
Beth N. Mizuno, Esq.                         Assistant County Attorney David E. Roth, Esq.                         Office of Robert F. Meehan, Westchester Brian G. Harris, Esq.                       County Attorney Andrea Z. Jones, Esq.                       148 Martine Avenue, 6th Floor Office of the General Counsel               White Plains, NY 10601 Mail Stop: 0-15 D21                         (E-mail: MJR 1*,)westchestergov.com)
U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: setanrc.gov)
(E-mail: bnml (@nrc.gov)
(E-mail: david.rothmnrc.gov)
(E-mail: brian.harrisa~nrc.gov)
(E-mail: andrea.ionesanrc.gov)
Manna Jo Greene, Environmental Director     Thomas F. Wood, Esq.
Stephen C. Filler, Board Member             Daniel Riesel, Esq.
Hudson River Sloop Clearwater, Inc.         Ms. Jessica Steinberg, J.D.
11 2 Little Market Street                   Sive, Paget & Riesel, P.C.
Poughkeepsie, NY 12601                       460 Park Avenue (E-mail: mannajo(@clearwater.org)           New York, NY 10022 (E-mail: sfiller(anylawline.com)             (E-mail: drieselasprlaw.com)
(E-mail: jsteinberg(@sprlaw.com)
Joan Leary Matthews, Esq.                  John Louis Parker, Esq.
Senior Attorney for Special Projects        Regional Attorney Office of the General Counsel              Office of General Counsel, Region 3 New York State Department of                NYS Dept. of Environmental Conservation Environmental Conservation                  21 S. Putt Comers Road 625 Broadway, 14th Floor                    New Paltz, New York 12561-1620 Albany, NY 12207                            (E-mail: ilparker(agw.dec.state.nv.us)
(E-mail: jImatthe~gw.dec.state.ny.us)
Ross Gould, Member                          Michael J. Delaney, V.P. - Energy Hudson River Sloop Clearwater, Inc.          New York City Economic Dev. Corp.
270 Route 308                                110 William Street Rhinebeck, NY 12572                          New York, NY 10038 (E-mail: rgouldesq0(gmail.com)              (E-mail: mdelanevanycedc.com)
 
Phillip Musegaas, Esq.                               Daniel E. O'Neill, Mayor Deborah Brancato, Esq.                               James Siermarco, M.S.
Riverkeeper, Inc.                                     Liaison to Indian Point 20 Secor Road                                         Village of Buchanan Ossining, NY 10562                                   Municipal Building (E-mail: phillipvriverkeeper.org)                     236 Tate Avenue (E-mail: dbrancato(iriverkeeper.ora)                 Buchanan, NY 10511-1298 (E-mail: vobgbestweb.net)
(E-mail: smurray(avillageofbuchanan.com)
Robert D. Snook, Esq.                                Mylan L. Denerstein, Esq.
Assistant Attorney General                            Executive Deputy Attorney General, Office of the Attorney General                        Social Justice State of Connecticut                                  Office of the Attorney General 55 Elm Street                                          of the State of New York P.O. Box 120                                          120 Broadway, 25th Floor Hartford, CT 06141-0120                              New York, New York 10271 (E-mail: Robert. Snook(po.state.ct.us)                (E-mail: Mylan.Denersteinaoag.state.ny.us)
John J. Sipos, Esq.                                  Janice A. Dean, Esq.
Charlie Donaldson Esq.                                Assistant Attorney General Assistants Attorneys General                          Office of the Attorney General Office of the Attorney General                         of the State of New York of the State of New York                            120 Broadway, 26th Floor The Capitol                                          New York, New York 10271 Albany, NY 12224-0341                                (E-mail: Janice.Dean(ioag.state.ny.us)
(E-mail: John.Sipos@iiag.n .gov)
* Original and 2 copies provided to the Office of the Secretary.
* Original and 2 copies provided to the Office of the Secretary.
ý7aphael P.Xuyler, Esq.DBI/66535983.5 }}
                                              ý7aphael P.Xuyler, Esq.
DBI/66535983.5
                                              }}

Revision as of 02:53, 13 November 2019

2011/02/18-Applicant's Answer to Hudson River Sloop Clearwater, Inc. and Riverkeeper, Inc.'S New Contentions Concerning the Waste Confidence Rule
ML110560270
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 02/18/2011
From: Bessette P, O'Neill M, Sutton K
Morgan, Morgan, Lewis & Bockius, LLP, Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS E-458, 50-247-LR, 50-286-LR
Download: ML110560270 (32)


Text

RAS Ew4S%

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of ) Docket Nos. 50-247-LR and

) 50-286-LR ENTERGY NUCLEAR OPERATIONS, INC. )

)

(Indian Point Nuclear Generating Units 2 and 3) )

) February 18, 2011 APPLICANT'S ANSWER TO HUDSON RIVER SLOOP CLEARWATER, INC. AND RIVERKEEPER, INC.'S NEW CONTENTIONS CONCERNING THE WASTE CONFIDENCE RULE William C. Dennis, Esq. Kathryn M. Sutton, Esq.

Entergy Nuclear Operations, Inc. Paul M. Bessette, Esq.

440 Hamilton Avenue MORGAN, LEWIS & BOCKIUS LLP White Plains, NY 10601 1111 Pennsylvania Avenue, N.W.

Phone: (914) 272-3202 Washington, D.C. 20004 Fax: (914) 272-3205 Phone: (202) 739-5738 E-mail: wdennis@entergy.com E-mail: ksutton@morganlewis.com E-mail: pbessette@morganlewis.com Martin J. O'Neill, Esq.

MORGAN, LEWIS & BOCKIUS LLP 1000 Louisiana Street Suite 4000 Houston, TX 77002 DOCKETED Phone: (713) 890-5710 February 18, 2011 (4:53 p.m.)

E-mail: martin.oneill@morganlewis.com OFFICE OF SECRETARY COUNSEL FOR ENTERGY NUCLEAR RULEMAKINGS AND ADJUDICATIONS STAFF OPERATIONS, INC.-

TI MfLA 9~ -no 570-e: D363

TABLE OF CONTENTS Page INTRODUCTION....................................................1 II. B A C K GR OUND ............................................................................................................... 3 A. The Waste Confidence Rulemaking and the Status of Efforts to Remove Spent Nuclear Fuel from Reactor Sites ............................................................. 3 B. Clearwater and Riverkeeper's New Waste Confidence Contentions .................... 6 III. LEGAL STANDARDS GOVERNING ADMISSION OF NEW AND AM ENDED CONTENTIONS ...................................................................................... 9 IV. THE NEW CONTENTIONS ARE INADMISSIBLE UNDER 10 C.F.R. § 2.309 ........ 12 A. Clearwater EC-8 (Riverkeeper EC-6) Is Inadmissible ..................................... 12

1. The Commission Rejected these Same Challenges in CLI-10-19 ..... 12
2. Clearwater EC-8 (Riverkeeper EC-6) Remains Inadmissible As It Challenges the NRC's Generic Findings Codified in the Amended Waste Confidence Rule, Under 10 C.F.R. §§ 2.309(f)(1)(iii) and 2 .335(a) ...................................................................... 13 1.........................
3. To the Extent Petitioners Seek to Raise a NEPA-Terrorism Claim Under Clearwater EC-8 (Riverkeeper EC-6), Such Claims Have Been Uniformly Rejected Before In This and Other Proceedings ..... 14
4. To the Extent Petitioners Seek to Challenge the Analysis of the No-Action Alternative in the FSEIS, Such Claims Fail to Raise A G enuine D ispute ................................................................................. 15 B. Clearwater SC-2 (Riverkeeper TC-3) Is Inadmissible ..................................... 16
1. Clearwater SC-2 (Riverkeeper TC-3) Is Untimely, Under 10 C.F.R.

§ 2.309(f)(2) and (c) ............................................................................. 16

2. Clearwater SC-2 (Riverkeeper TC-3) Does Not Specifically State the Issue of Law or Fact to Be Raised and Fails to Explain the Basis and Support for the Contention, As Required By 10 C.F.R.

§ 2.309(f)(1)(i), (ii), and (v) .................................................................. 18

3. Clearwater SC-2 (Riverkeeper TC-3) Raises Issues That Are Beyond the Scope of this Proceeding, Under 10 C.F.R.

§ 2.309(f)(1)(iii) ................................................................................. 20

4. Clearwater SC-2 (Riverkeeper TC-3) Raises No Genuine Dispute Regarding Entergy's Spent Fuel Pool AMPs, As Required By 10 C.F.R . § 2.309(f)(1)(vi) .................................................................. 21 C. Clearwater EC-9 (Riverkeeper EC-7) and Clearwater SC-3 (Riverkeeper TC-4) Do Not Cure the Defects in Petitioners' First Set of Contentions ...... 22

Page

1. Petitioners' Alternative Contentions Suffer From the Same Deficiencies As the Initial Set ........................................................... . 23
2. There Is No Regulatory Gap Regarding Impacts More than 60 Years Beyond Licensed Life, and to the Extent Any Perceived Gap May Exist, It Is the Subject of An Ongoing Commission Rulem aking ........................................................................................ 23 V. C ON C LU SIO N ............................................................................................................... 26

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of ) Docket Nos. 50-247-LR and

) 50-286-LR ENTERGY NUCLEAR OPERATIONS, INC. )

)

(Indian Point Nuclear Generating Units 2 and 3) )

_) February 18, 2011 APPLICANT'S ANSWER TO HUDSON RIVER SLOOP CLEARWATER, INC. AND RIVERKEEPER, INC.'S NEW CONTENTIONS CONCERNING THE WASTE CONFIDENCE RULE I. INTRODUCTION Pursuant to 10 C.F.R. § 2.309(h)(1) and the Board's February 17, 2011 Order,' Entergy Nuclear Operations, Inc. ("Entergy") submits this Answer opposing the "Joint Motion for Leave to Add Contentions Based Upon New Information and Petition to Add New Contentions" ("New Contentions") filed by Hudson River Sloop Clearwater, Inc. ("Clearwater") and Riverkeeper, Inc. ("Riverkeeper") (collectively, "Petitioners") on January 24, 2011.

Clearwater and Riverkeeper submitted four new contentions, two environmental and two safety-related. Two contentions are premised on the assumption that the "new waste confidence rule is invalid.",2 These contentions essentially duplicate, with minor changes, the contentions 3

Clearwater submitted in October 2009 and that the Commission rejected in CLI-10-19.

Licensing Board Order (Extending Page Limitations for Pleadings as They Apply to Answers to Clearwater's and Riverkeeper's January 24, 2011, Joint Motion, and New York State's Motion to Amend Contention 17A and Waiver Petition, Filed January 24, 2011). (Feb. 17, 2011) (unpublished).

2 New Contentions at 17, availableat ADAMS Accession No. ML110330089 (citing Waste Confidence Decision Update, 75 Fed. Reg. 81,037 (Dec. 23, 2010) ("2010 Waste Confidence Decision"); Final Rule, Consideration of Environmental Impacts of Temporary Storage of Spent Fuel After Cessation of Reactor Operation, 75 Fed. Reg. 81,032 (Dec. 23, 2010)

("Temporary Storage Rule")).

Entergy Nuclear Operations,Inc. (Indian Point Nuclear Generating Units 2 & 3), CLI-10-19, slip op. (July 8, 2010) ("CLI-10-19").

Recognizing that their first two contentions likely remain outside the scope of this proceeding for essentially the same reasons set forth in CLI- 10-19, Petitioners this time also submit a second set of two contentions: "[i]n the alterative, if the Board decides that Petitioners cannot challenge duly adopted NRC rules in these proceedings .... .. The "alternative" contentions are premised on a perceived gap in the Commission's findings supporting the amended Waste Confidence Rule.5 Specifically, Petitioners allege that "the Commission'ss generic findings with respect to onsite fuel storage in both wet pools and dry casks relate only to the period 60 years beyond the 6

expiration of a plant's operating license" and no further.

As an initial matter, there is essentially nothing new in Petitioners' proposed contentions.

Indeed, most of Petitioners' pleading is a recitation of the legal history of the Waste Confidence Rule and federal efforts to develop a repository for spent fuel and high-level waste, 7 largely copied from Clearwater's earlier contentions. 8 The proposed contentions themselves essentially duplicate the contentions proffered by Clearwater over a year ago. 9 As Petitioners recognize, the Commission rejected those claims in CLI-10-19.10 Indeed, similar claims have also been uniformly rejected in other proceedings.

Similarly, Petitioners' New Contentions should be denied in their entirety. First, Petitioners directly challenge the Waste Confidence Rule, 10 C.F.R. § 51.23, as amended, 4 New Contentions at 18.

5 See id. at 18, 33.

6 Id. at 33.

7 See generally id. at 3-17, 18-27, 29-33, 34, 36-38.

8 See generally Hudson River Sloop Clearwater, Inc.'s Motion for Leave to Add New Contentions Based Upon New Information (Oct. 26, 2009; corrected version, Nov. 6, 2009), availableat ADAMS Accession Nos. ML093080129, ML093200503.

9 See Licensing Board Memorandum and Order (Certification to the Commission of a Question Relating to the Continued Viability of 10 C.F.R. § 51.23(b) Arising From Clearwater's Motion for Leave to Admit New Contentions) at 18-22 (Feb.

12, 2010) (unpublished) ("Feb. 12, 2010 Order").

10 CLI-10-19, slip op. at 2.

contrary to the acknowledged, long-standing NRC prohibition against attacks on Commission regulations, codified in 10 C.F.R. § 2.335. Second, Petitioners' safety contentions are untimely, contrary to 1.0 C.F.R. § 2.309(f)(2) and (c). Third, Petitioners attempt to raise issues related to the Indian Point Energy Center ("IPEC" or "Indian Point") Independent Spent Fuel Storage Installation ("ISFSI"), which are not within the scope of this proceeding, and therefore do not meet the requirements of 10 C.F.R. § 2.309(f)(1)(iii). Finally, by ignoring the portions of Entergy's license renewal application ("LRA") that include aging management programs

("AMPs") for the spent fuel pools, Petitioners fail to raise a genuine dispute on a material issue of law or fact, as required by 10 C.F.R. §2.309(f)(1)(vi). Accordingly, the New Contentions fail to meet the admissibility requirements set forth in 10 C.F.R. § 2.309(f)(1).

II. BACKGROUND A. The Waste Confidence Rulemaking and the Status of Efforts to Remove Spent Nuclear Fuel from Reactor Sites The general history of the Waste Confidence Rule has been recited by both the Board and Commission in response to several prior proposed contentions and related documents in this proceeding." Most importantly, the Commission has plainly stated that, "'[i]n the area of waste storage, the Commission largely has chosen to proceed generically' through the rulemaking process - that is, the Waste Confidence Rule, codified at 10 C.F.R. § 51.23 - instead of litigating issues case-by-case in adjudicatory proceedings."'12 See, e.g., Feb. 12, 2010 Order at 18-22.

12 CLI-10-19 slip op. at 2 (quoting Duke Energy Corp. (Oconee Nuclear Station, Units 1, 2, & 3), CLI-99-11, 49 NRC 328, 343 (1999)).

In 2008, the Commission proposed to update the Waste Confidence Rule to "confirm the 13 Commission's confidence that spent fuel storage is safe and secure over long periods of time."

This review led to certain revisions in 2010 to the Commission's waste confidence "Findings" (i.e., the conclusions that support the Waste Confidence Rule). 14 Specifically, the Commission revised its second Waste Confidence Finding from a conclusion that there is reasonable assurance that a repository with sufficient capacity will be available within the first quarter of the twenty-first century to a conclusion that sufficient repository capacity will be available when 15 necessary.

The target date for repository availability was removed from this finding because "recent events have demonstrated that the Commission is unable to predict with confidence when a successful program to construct a repository will start."'16 This is because, although the Commission has confidence that spent fuel can be safely stored without significant environmental impacts for long periods, there are issues beyond the Commission's control, including political and societal challenges that make it premature to predict a precise date for repository availability.' 7 In 2010 the Commission also revised its fourth Waste Confidence Finding from one that spent fuel can be safely stored for 30 years beyond a reactor's licensed life for operation, to one that concludes that spent fuel can be safely stored for at least 60 years beyond licensed operation, including the term of a renewed license.18 Consistent with these 13 Proposed Rule, Consideration of Environmental Impacts of Temporary Storage of Spent Fuel After Cessation of Reactor Operation, 73 Fed. Reg. 59,547, 59,549 (Oct. 9, 2008). See also Waste Confidence Decision Update; Update and Proposed Revision of Waste Confidence Decision, 73 Fed. Reg. 59,551 (Oct. 9, 2008).

14 See 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,038.

is See id. at 81,038-39.

16 Id. at 81,048.

17 See id. at 81,042.

IS See id. at 81,038.

findings, the Commission revised 10 C.F.R. § 51.23(a) regarding the environmental impacts of spent fuel storage as follows:

The Commission has made a generic determination that, if necessary, spent fuel generated in any reactor can be stored safely and without significant environmental impactsfor at least 60 years beyond the licensed life for operation (which may include the term of a revised or renewed license) of that reactor in a combination of storage in its spent fuel storage basin and at either onsite or offsite independent spent fuel storage installations. Further, the Commission believes there is reasonable assurance that sufficient mined geologic repository capacity will be available to dispose of the commercial high-level waste and spent fuel generated in any reactor when necessary.19 Finally, the Commission directed the NRC Staff to further develop a plan for a rulemaking and an Environmental Impact Statement ("EIS") to assess the environmental impacts and safety of 20 long-term waste storage, beyond 120 years.

Importantly, and contrary to Petitioners' proposed contentions, the Waste Confidence Rule does not-and cannot-establish the schedule for the removal of spent nuclear fuel from any reactor site, including IPEC. Under the Nuclear Waste Policy Act of 1982, as amended, 42 U.S.C. § 10101 et seq. ("NWPA"), the federal government, through DOE, remains solely responsible for siting and building a repository.21 Neither the Board nor the Commission has the statutory authority to take such actions. The Commission itself recognizes that the schedule for such activities is influenced by many "issues beyond the Commission's control, including the political and societal challenges of siting a [high-level waste] repository, that make it premature to predict a precise date or time frame when a repository will become available." 22 Thus, Section 51.23, as amended, simply reflects the current reality; i.e., uncertainty regarding the timing of the 19 10 C.F.R. § 51.23(a) (emphasis added). See also 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,038.

20 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,040.

21 See id. at 81,049.

22 See id. at 81,042.

availability of a geologic repository for spent nuclear fuel and high-level waste, but it does not 23 set forth or establish any timetable for such removal.

The effect of the amended rule, however, is to continue the Commission's long-standing generic treatment via rulemaking which precludes litigation of such issues in individual licensing proceedings. 24 Relying now on the Commission's 2010 Waste Confidence Decision, 10 C.F.R.

§ 51.23(b) remains unchanged, and continues to state that:

[N]o discussion of any environmental impact of spent fuel storage in reactor facility storage pools or independent spent fuel storage installations (ISFSI) for the period following the term of the reactor operating license . . . for which application is made, is required in any environmental report, environmental impact statement . . . or other analysis prepared in connection with the issuance . . . of an operating license for a nuclear power reactor under parts 50 and 54 of this chapter .... 25 Thus, 10 C.F.R. § 51.23(b) unambiguously applies to "any environmental impact."

Furthermore, 10 C.F.R. § 51.95(c)(2) provides that "the supplemental environmental impact statement prepared at the license renewal stage need not discuss... any aspect of the storage of spent fuel for the facility within the scope of the generic determination in § 51.23(a) and in accordance with § 51.23(b)." Thus, all environmental impacts of spent fuel storage following 26 the license renewal period have been and continue to be outside the scope of this proceeding.

B. Clearwater and Riverkeeper's New Waste Confidence Contentions On January 24, 2010, Clearwater and Riverkeeper submitted four new contentions, two environmental and two safety-related. As noted above, the first two contentions are premised on 23 See id. at 81,040.

24 See CLI-10-19, slip op. at 2-3.

25 Emphasis added.

26 See, e.g., CLI- 10-19, slip op. at 2-3; Oconee, CLI-99-11, 49 NRC at 343-46; Entergy Nuclear Vt. Yankee, LLC & Entergy Nuclear Operations,Inc. (Vt. Yankee Nuclear Power Station), LBP-06-20, 64 NRC 131, 170 (2006).

the assumption that the "new waste confidence rule is invalid." 27 In the first, an environmental contention ("CW EC-8/RK EC-6"), Petitioners allege:

The environmental analysis carried out to assess the potential impacts of relicensing Indian Point Units 2 and 3 is inadequate because it provides an insufficient analysis of the potential impacts of generating more spent fuel leading to additional waste storage on site, the alternative methods of accomplishing such storage, and potential alternatives to additional waste storage on the site, including the no-action alternative.28 In the second, a safety contention ("CW SC-2/RK TC-3"), Petitioners allege:

The license renewal application requesting the relicensing of Indian Point Units 2 and 3 is inadequate because it provides insufficient analysis of the aging management of the dry casks and spent fuel pools that could be used to store waste on the site in the long term. In addition, both the applicant and the NRC Staff have failed to establish that any combination of such storage 29 will provide adequate protection of safety over the long term.

These contentions essentially duplicate, with minor changes (or no changes, in the case of CW SC-2/RK TC-3), the contentions Clearwater submitted in October 2009 and that the Commission rejected in CLI- 10-1 9.31 Recognizing that their first two contentions likely remain outside the scope of this proceeding for essentially the same reasons set forth in CLI-10-19, Petitioners this time also submit a second set of two contentions: "[iun the alterative, if the Board decides that Petitioners cannot challenge duly adopted NRC rules in these proceedings .... ,,31 Thus, in the "rule valid scenario," there is a second environmental contention ("CW EC-9/RK EC-7"):

The environmental analysis carried out to assess the potential impacts of relicensing Indian Point Units 2 and 3 is inadequate 27 New Contentions at 17.

28 Id.

29 Id. at 18.

30 CLI- 10-19, slip op. at 3.

31 New Contentions at 18.

because it provides an insufficient analysis of the potential impacts of generating more spent fuel during the period commencing 60 years after the expiration of each license. Missing elements include analysis of: a) the long term impact of additional waste storage on site; b) the alternative methods of accomplishing such storage; and c) potential alternatives to additional 32 waste storage on the site, including the no-action alternative.

And there is a second safety contention ("CW SC-3/RK.TC-4"):

The license renewal application requesting the relicensing of Indian Point Units 2 and 3 is inadequate because it provides insufficient analysis of the aging management of the dry casks and spent fuel pools that could be used to store waste on the site during the period commencing 60 years after the date the license expires at each unit. In addition, both the applicant and the NRC Staff have failed to establish that that any combination of such storage 33 will provide adequate protection of safety over the long term.

In support of these New Contentions, Petitioners refer to, but do not include, a declaration from Dr. Gordon R. Thompson prepared in support of Clearwater's prior rejected 35 proposed contentions. 34 That declaration, however, refers only to other documents.

Aside from their explicit challenges to the amended Waste Confidence Rule, Petitioners also raise a host of new and vaguely-related claims under the cover of these contentions.

Specifically, Petitioners identify a list of alleged "specific issues that site-specific and generic 32 Id.

33 Id.

34 The Declaration of Dr. Gordon R. Thompson in Support of Contentions Concerning Waste Storage and Disposal at Indian Point Submitted by Hudson River Sloop Clearwater, Inc. (Oct. 26, 2009) ("Thompson Declaration") appears in ADAMS at Accession No. ML093080129. Petitioners do not resubmit the "cover" Thompson Declaration with the new proposed contentions. These facts render all of Clearwater and Riverkeeper's new contentions totally unsupported and subject to dismissal on these grounds alone. The Licensing Board "should not be expected to sift unaided through ...earlier briefs filed before the Presiding Officer in order to piece together and discern the Intervenors' particular concerns or the grounds for their claims." Fla. Power & Light Co. (Turkey Point Nuclear Generating Plant, Units 3 & 4), CLI-01-17, 54 NRC 3, 15 (2001) (citingHydro Res., Inc. (P.O. Box 15910, Rio Rancho, N.M. 87174), .CLI-01-4, 53 NRC 31,46 (2001)).

35 See generally Thompson Declaration. For example, the Thompson Declaration refers to Gordon R. Thompson, Environmental Impacts of Storing Spent Nuclear Fuel and High-Level Waste from Commercial Nuclear Reactors: A Critique of NRC's Waste Confidence Decision and Environmental Impact Determination (Feb. 6, 2009) ("Thompson/TSEP Report")). Petitioners also mention this document on page 7 of their New Contentions and refer again to Dr. Thompson's "many reports" on page 43, but, contrary to the Board's Scheduling Order, do not provide an ADAMS citation. Therefore, it should "not be considered by the Board." See Licensing Board Scheduling Order at 18 (July 1, 2010) (unpublished). The ThompsonJTSEP Report appears to be available in ADAMS at ML090700781, included in a document submitted by various groups as comments in the recent waste confidence rulemaking.

8-

safety analyses fail to address" including the alleged "potential for ongoing leaks of radioactivity from existing spent-fuel pools to get worse over the long term." 36 The FSEIS, however, includes a substantial discussion of the status of spent fuel pool leakage, including potential environmental impacts, but Petitioners do not cite or challenge any of the information in the FSEIS.37 The remaining items are addressed in Sections IV.A and IV.B, below, to the extent they can be understood to raise either safety or environmental issues.

Following Petitioners' submittal of their New Contentions, the State of New York ("New York") submitted a 23-page "Answer in Support of the Admission of Clearwater and Riverkeeper's Proposed Waste Confidence Contentions" 38 Most of the issues raised in the New York Answer are not new. New York, however, for the first time refers to alleged problems associated with the presence of spent fuel from Indian Point, Unit 1 ("IPI"), 39 and that the findings in the Waste Confidence Rule will allegedly no longer apply to IP1 after 2034.40 The environmental impacts of any spent fuel associated with IP1 (which is all now stored in an ISFSI), of course, are outside the scope of this proceeding regarding Entergy's application to renew the licenses for IP2 and IP3. New York also claims that the NRC's FSEIS for IPEC license renewal 4 ' is deficient because it relies upon the prior Waste Confidence Rule rather than the amended rule,42 but this is not an allegation raised in Petitioners' contention.43 36 New Contentions at 35.

37 See FSEIS at 2-110 to -114, 4-56. Moreover, Petitioners both already have an admitted contention regarding spent fuel pool leaks. See Entergy Nuclear Operations,Inc. (Indian Point Nuclear Generating Units 2 & 3), LBP-08-13, 68 NRC 43, 188-91 (2008) ("LBP-08-13") (admitting Riverkeeper EC-3); id. at 191-94 (admitting Clearwater EC-1).

38 Feb. 10, 2011 ("New York Answer"). This document is not yet available in ADAMS.

39 Id. at 4.

40 See id. at 8.

41 NUREG -1437, Supp. 38, Generic Environmental Impacts Statement for License Renewal of Nuclear Plants, Regarding Indian Point Nuclear Generating Unit Nos. 2 & 3 (Dec. 3, 2010) ("FSEIS"), available in ADAMS at Accession No.

ML103350405.

42 See New York Answer at 17-18.

III. LEGAL STANDARDS GOVERNING ADMISSION OF NEW AND AMENDED CONTENTIONS An intervenor may file new environmental contentions "if there are data or conclusions in the NRC draft or final environmental impact statement, environmental assessment, or any supplements relating thereto, that differ significantly from the data or conclusions in the applicant's documents."44 Absent such circumstances, an intervenor may file new contentions only with leave of the presiding officer upon a showing that the new or amended contention is based on information that was not previously available and is materially different than information previously available. 4 5 The Commission very recently reiterated that the publication of a new document, standing alone, does not meet this standard unless the information in that document is new and materially different from what was previously available.46 Furthermore, the Petitioner must act promptly to bring the new or amended contention. 47 A new contention is 48 not an occasion to raise additional arguments that could have been raised previously.

If an intervenor cannot satisfy the criteria of 10 C.F.R. § 2.309(f)(2), then a contention is considered nontimely, and the intervenor must successfully address the late-filing criteria in Section 2.309(c)(1)(i)-(viii). 49 The first factor identified in that regulation, whether "good cause" 43 Nor is it raised in New York's proposed amended Contention 17B. To the extent the New York Answer seeks to supplement or bolster the arguments in the State's own January 24, 2010 filings, the New York Answer is untimely, unauthorized, and inappropriate..

44 10 C.F.R. § 2.309(0(2).

45 Id. § 2.309(f)(2)(i)-(iii).

46 See, e.g., N. States Power Co. (Prairie Island Nuclear Generating Plant, Units 1 & 2), CLI-10-27, slip op. at 13-18 (Sept.

30, 2010).

47 See EntergyNuclear Vt. Yankee, LLC (Vt. Yankee Nuclear Power Station), LBP-06-14, 63 NRC 568, 573 & 579-80 (2006)

(rejecting petitioner's attempt to "stretch the timeliness clock" because its new contentions were based on information that was previously available and petitioners failed to identify precisely what information was "new" and "different").

49 Duke Energy Corp. (McGuire Nuclear Station, Units I & 2; Catawba Nuclear Station, Units I & 2), CLI-02-28, 56 NRC 373, 385-86 (2002). This Board has emphasized that that it "will not entertain contentions based on environmental issues that could have been raised when the original contentions were filed." Licensing Board Memorandum and Order (Summarizing Pre-Hearing Conference) at 3 (Feb. 4, 2009) (unpublished) ("Pre-Hearing Conference Order").

49 See Licensing Board Scheduling Order at 5-6; 10 C.F.R. § 2.309(c)(2) ("The requestor/petitioner shall address the factors in paragraphs (c)(1)(i) through (c)(1)(viii) of this section in its nontimely filing.").

exists for the failure to file on time, is entitled to the most weight.50 Without good cause, a "petitioner's demonstration on the other factors must be particularly strong." 5' A proposed contention also "must satisfy, without exception, each of the criteria set out in 10 C.F.R. § 2.309(f)(1)(i) through (vi)." 52 Failure to meet each of the criteria is grounds for dismissal of a proposed new or amended contention. 53 Among other things, the petitioner must demonstrate that the issue raised in the contention is within the scope of the proceeding, is material to the findings the NRC must make to support the action that is involved in the proceeding, and provide sufficient information to show that a genuine dispute exists with the applicant/licensee on a material issue of law or fact. 54 A dispute is material if its resolution would make a difference in the outcome of the licensing proceeding.55 Additionally, the Commission has held that a petitioner may not use an adjudicatory proceeding to attack generic rules or regulations. 56 Thus, a licensing proceeding is plainly not the proper forum for an attack on applicable statutory requirements or for challenges to the basic structure of the Commission's regulatory process.57 A contention that collaterally attacks an NRC rule 'or regulation is not appropriate for litigation and must be rejected. 58 Similarly, 50 See New Jersey (Dep't of Law & Pub. Safety's Requests Dated Oct. 8, 1993), CLI-93-25, 38 NRC 289, 296 (1993).

51 Tex. Utils. Elec. Co. (Comanche Peak Steam Elec. Station, Units I & 2), CLI-92-12, 36 NRC 62, 73 (1992) (quoting Duke Power Co. (Perkins Nuclear Station, Units 1, 2 & 3), ALAB-431, 6 NRC 460, 462 (1977)).

52 S.C. Elec. & Gas Co. (Virgil C. Summer Nuclear Station, Units 2 & 3), LBP-10-06, slip op. at3 (Mar. 17, 2010).

53 See Changes to Adjudicatory Process, 69 Fed. Reg. 2182, 2221 (Jan. 14, 2004). See also PrivateFuel Storage, L.L. C.

(Indep. Spent Fuel Storage Installation), CLI-99-10, 49 NRC 318, 325 (1999).

54 See 10 C.F.R. § 2.309(f)(1)(iii)(iv) & (vi).

55 See Summer, LBP-10-06, slip op. at 4 (quoting Oconee, CLI-99-11, 49 NRC at 333-34).

56 10 C.F.R. § 2.335(a); Oconee, CLI-99-11,49 NRC at 334.

57 See Phila. Elec. Co. (Peach Bottom Atomic Power Station, Units 2 & 3), ALAB-216, 8 AEC 13, 20, aff'd in part on other grounds, CLI-74-32, 8 AEC 217 (1974). See also CarolinaPower & Light Co. (Shearon Harris Nuclear Power Plant),

LBP-07-11, 66 NRC 41, 57-58 (2007) (citingPeach Bottom, ALAB-216, 8 AEC at 20).

58 See, e.g., Dominion Nuclear Conn., Inc. (Millstone Nuclear Power Station, Unit 2), CLI-03-14, 58 NRC 207, 218 (2003);

PotomacElec. Power Co. (Douglas Point Nuclear Generating Station, Units I & 2), ALAB-218, 8 AEC 79, 89 (1974).

licensing boards should not accept in individual license proceedings contentions which are (or 59 are about to become) the subject of a rulemaking by the Commission.

IV. THE NEW CONTENTIONS ARE INADMISSIBLE UNDER 10 C.F.R. § 2.309 A. Clearwater EC-8 (Riverkeeper EC-6) Is Inadmissible

1. The Commission Rejected these Same Challenges in CLI-]0-19 CW EC-8/RK EC-6 claims that the existing NEPA review is inadequate because it does not evaluate the impacts of storing additional waste onsite or potential alternative storage methods. 60 In support, Petitioners rely upon the Thompson/TSEP Report, which, as noted above, 6

is not attached or even directly referenced in the New Contentions. '

As noted above, Clearwater submitted essentially the same contention in October 2009, and the Commission rejected it in CLI-10-19. 62 In that decision, the Commission reiterated its longstanding position that, "'[i]n the area of waste storage, the Commission has largely chosen to proceed generically' through the rulemaking process - that is, the Waste Confidence Rule, codified at 10 C.F.R. § 51.23 - instead of litigating issues case-by-case in adjudicatory proceedings." 63 The Commission went on to clearly state that "challenges to the Waste Confidence Rule must be made in the context of a rulemaking, not in the context of an adjudicative proceeding." 64 Because the then-ongoing rulemaking to update the Waste 59 See Oconee, CLI-99-11, 49 NRC at 345 (quoting DouglasPoint, ALAB-218, 8 AEC at 85).

60 New Contentions at 17.

61 Notably, Petitioners do not claim that anything in the Thompson Declaration or the Thompson/TSEP Report qualifies as "new" information orinformation that was "previously unavailable." Nor could they, as other licensing boards have found that a similar Dr. Thompson declaration attaching this same report does not contain significant new factual information.

See ProgressEnergy Fla., Inc. (Combined License Application for Levy Cnty. Nuclear Power Plants, Units ! & 2), LBP-09-10, slip op. at 102 (July 8, 2009) ("Indeed, Dr. Thompson's Declaration (which deals with the risks associated with the high density storage and racking of spent nuclear fuel in pools), covers information and grounds that a 2006 licensing board characterized as 'well trod."').

62 Slip op. at 2-3.

63 Id. at 2 (quotingOconee,CLI-99-1 1, 49 NRC at 343).

64 Id.

Confidence Rule was already examining the very issues Clearwater sought to litigate, it would be "unnecessary and wasteful" to admit its proposed contentions.65 As a result, the Commission directed the Board to deny Clearwater's proposed contentions.66 The Commission and its Boards have also rejected similar contentions in numerous other recent proceedings. 67 The only difference is that the current proposed contention challenges the outcome of the NRC's recent rulemaking, contrary to 10 C.F.R. § 2.335, rather than the previously-existing rule. Proposed contention CW-EC8/RK-EC-6 remains inadmissible for the reasons set forth in CLI-10-19.

2. ClearwaterEC-8 (RiverkeeperEC-6) Remains InadmissibleAs It Challenges the NRC's Generic FindingsCodifled in the Amended Waste Confldence Rule, Under 10 CF.R. ,, 2.309(l)(1)(iii) and 2.335(a)

Although the Commission has amended the Waste Confidence Rule since CLI-10-19, CW-EC8/RK-EC-6 remains an inadmissible challenge to the rule, as Clearwater and Riverkeeper readily admit. As stated above, the Commission has unequivocally stated that "no discussion of any environmental impact" from spent fuel storage "for the period following the term of the reactor operating license" is required in "any" environmental impact statement. 68 In fact, 65 See id. at 3.

66 See id.

67 See, e.g., ProgressEnergy Carolinas,Inc. (Shearon Harris Nuclear Plant, Units 2 & 3), LBP-08-21, 68 NRC at 554, 587 (2008) (holding that a contention seeking reconsideration of the Waste Confidence Rule and alleging it is inapplicable to new plants was an impermissible challenge to regulations and noting that "[a]t least seven other licensing boards have considered identical matters and have squarely rejected" it), aff'd CLI-10-09, slip op. at 37-38 (Mar. 11, 2010); Tenn.

Valley Auth. (Watts Bar Unit 2), LBP-09-26, slip op. at 45-47 (Nov. 19, 2009) (rejecting contention as impermissible challenge to the subject matter of a pending rulemaking); Detroit Edison Co. (Fermi Nuclear Power Plant, Unit 3), LBP 16, slip op. at 16-19 (July 31, 2009) (rejecting a similar challenge to the Waste Confidence Rule on similar grounds); Tenn.

Valley Auth. (Bellefonte Nuclear Power Plant Units 3 & 4), LBP-08-16, 68 NRC 361, 415-16 (2008) (rejecting a challenge on similar grounds, including the claim that the rule "should be reconsidered given the uncertainty about the availability of the second geologic repository" that would allegedly be needed for spent fuel from new reactors). See also Licensing Board Order (Ruling on New York State's New and Amended Contentions) at 16 (June 16, 2009) (unpublished) ("the regulations now in force, specifically 10 C.F.R. § 51.23(b), do not permit discussion of any environmental impact of spent fuel storage at nuclear reactor sites") (emphasis in original, internal quotations omitted).

68 10 C.F.R. § 51.23(b) (emphasis added).

Petitioners concede that the Waste Confidence Rule does "not contemplate the assessments that Petitioners contend are missing ... "69 Despite the plain language of the amended and controlling Waste Confidence Rule, Petitioners nevertheless claim that Entergy or the NRC Staff should have performed a site specific assessment of the environmental impacts of spent fuel storage after the period of extended operation. 70 It is well established, however, that absent a waiver, no rule or regulation of the Commission is subject to attack by way of discovery, proof, argument, or other means in

.any adjudicatory proceeding. 7 1 Here, Petitioners make no attempt to satisfy the requirements for waiver. Therefore, CW-EC8/RK-EC-6 must be rejected in accordance with 10 C.F.R.

§§ 2.309(f)(l)(iii) and 2.335(a).

3. To the Extent Petitioners Seek to Raise a NEPA-Terrorism Claim Under ClearwaterEC-8 (RiverkeeperEC-6), Such Claims Have Been Uniformly Rejected Before In This and Other Proceedings According to Petitioners, one example of an issue they seek to litigate under CW-EC8/RK-EC-6 is the question of whether "long-term wet storage of spent-fuel in high-density racks does not meet the NRC requirements for adequate protection and renders the plant excessively vulnerable to terrorism." 72 To the extent this allegation seeks to raise terrorism-related claims under NEPA, such claims are outside the scope of this proceeding for the reasons set forth in Commission decisions in the Oyster Creek and Pilgrim license renewal 69 New Contentions at 41.

70 Id. at 19-20 (asserting the need for a NEPA assessment of the long term or indefinite storage of spent fuel). The Commission has explained that the Waste Confidence Rule "applies only to the storage of spent fuel after a reactor ceases operation." Turkey Point, CLI-01-17, 54 NRC at 23 n. 14. Nonetheless, to the extent that Petitioners challenge the environmental impacts of spent fuel storage during the license renewal term for IP2 and IP3, such challenges are barred by 10 C.F.R. Part 51 and its underlying Generic Environmental Impact Statement. See id. at 22-23.

71 10 C.F.R. § 2.335(a).

72 New Contentions at 36.

proceedings, 73 and in the Board's earlier decision in this proceeding. 74 Specifically, the Commission has concluded that NEPA "imposes no legal duty on the NRC to consider intentional malevolent acts .. in conjunction with commercial power reactor license renewal applications.'" 75 Regardless, in the GEIS, the NRC performed a discretionary analysis of intentional acts in connection with license renewal, and concluded that "the core damage and radiological release from such acts would be no worse than the damage and release expected from internally initiated events." 76 Thus, any NEPA-terrorism allegation that might be considered as part of proposed contention EC8/RK-EC-6 is also outside the scope of this proceeding under 10 C.F.R. § 2.309(f)(1)(iii).

4. To the Extent PetitionersSeek to Challenge the Analysis of the No-Action Alternative in the FSEIS, Such Claims Fail to Raise a Genuine Dispute Contention EC8/RK-EC-6 also asserts that the "environmental analysis carried out to assess the potential impacts of relicensing Indian Point Units 2 and 3 is inadequate because it provides an insufficient analysis of ... potential alternatives to additional waste storage on the site, including the no-action alternative." 77 Petitioners, however, must "read the pertinent portions" of, in this case, the FSEIS, and explain why they disagree with the analysis in that document. Here, Petitioners do not reference or explain their challenge to any of the information in the FSEIS regarding the no action alternative, 79 so CW EC8/RK-EC-6 fails to 73 See Entergy Nuclear Generation Co. (Pilgrim Nuclear Power Station), CLI-l0-14, slip op. at 36-37 (June 17, 2010);

AmerGen Energy Co. (Oyster Creek Nuclear Generating Station), CLI-07-8, 65 NRC 124, 129 (2007), aff'd sub noma.N.J.

Dep 't ofEnvtl. Prot. v. ARC, 561 F.3d 132, 137-44 (3rd Cir. 2009).

74 LBP-08-13, 68 NRC at 140-43 (rejecting NYS-27 as inadmissible).

75 Pilgrim, CLI-10-14, slip op. at 37 (quoting Oyster Creek, CLI-07-8, 65 NRC at 129).

76 Id. (quotingOyster Creek, CLI-07-8, 65 NRC at 131).

77 New Contentions at 17.

78 See Final Rule, Rules of Practice for Domestic Licensing Proceedings-Procedural Changes in the Hearing Process, 54 Fed.

Reg. 33,168, 33,170 (Aug. 11, 1989); Millstone, CLI-01-24, 54 NRC at 358.

79 See FSEIS § 8.2 (No-Action Alternative).

raise a genuine dispute on a material issue of law or fact, as required by 10 C.F.R.

§ 2.309(0(1)(vi).

B. Clearwater SC-2 (Riverkeeper TC-3) Is Inadmissible

1. ClearwaterSC-2 (Riverkeeper TC-3) Is Untimely, Under 10 CF.R. . 2.309(t)(2) and (c)

Although Petitioners are permitted, with leave of the Board, to file new contentions based on new and materially different information, Petitioners fail to meet the mandatory requirements for such new contentions as defined in 10 C.F.R. § 2.309(f)(2)(i)-(iii) with respect to Contention CW SC-2/RK TC-3. The only purportedly "new" information that Clearwater points to is the amended Waste Confidence Rule.8 0 Petitioners do not claim that anything in the Thompson Declaration or the Thompson/TSEP Report qualifies as "new" information or information that was "previously unavailable."81 In this new safety contention, Petitioners challenge whether Entergy's LRA provides adequate aging management for the spent fuel pools at IPEC and the plant's ISFSI. Petitioners, however, do not identify what safety regulation, old or new, Entergy's LRA allegedly violates.

Further, the Commission's amendment of its environmental regulations in 10 C.F.R. § 51.23 simply does not provide any new information that might support the admission of this proposed safety contention, and Petitioners point to none. Petitioners also point to no amendment to the LRA that might have changed Entergy's relevant AMPs and no other new safety analysis that might serve as the trigger for an amended safety contention. Indeed, the relevant aspects of Entergy's LRA, discussed in Section IV.B.4, below, were included in the initial LRA filed by 80 See New Contentions at 3-7, 11,40-41, 44-47.

81 See supra note 61.

Entergy on April 23, 2007.82 As a result, CW SC-2/RK TC-3 is untimely under 10 C.F.R.

§ 2.309(f)(2).

Because Petitioners have not satisfied the criteria in 10 C.F.R. § 2.309(f)(2), they must satisfy the test set forth in 10 C.F.R. § 2.309(c)(1). Petitioners assert that the first and most important factor of "good cause" weighs in their favor because their contentions are timely.83 As explained above, they are not, so Section 2.309(c)(1)(i) weighs against admission of the New Contentions for the same reasons they fail to satisfy Section 2.309(f)(2).84 Nor have Petitioners made a "compelling showing" as to any of the remaining factors under Section 2.309(c)(1) to outweigh the lack of good cause. 85 While Petitioners assert that factors 2 through 4 (nature and extent of petitioners' right to be made a party, their property or financial interests in the proceeding, the possible effect of any order on petitioners' interests) weigh in their favor, 86 these factors do not relate to the pending New Contentions, because Petitioners are already parties to this proceeding. 87 The fifth and sixth factors (availability of other means to protect petitioners' interest and the extent to which petitioners' interests will' be represented by existing parties) 88 weigh against admission of the New Contentions because, contrary to Petitioners' assertions,89 many of the concerns raised in the New Contentions are either addressed in Petitioners' admitted contentions on alleged spent fuel pool leakage, or relate 82 See LRA Tables 3.5.2-3, 3.3.2-1-IP2, 3.3.2-1-IP2 (Apr. 23, 2007), availableatADAMS Accession No. ML071210517.

83 See New Contentions at 46.

84 See Exelon Generation Co. (Early Site Permit for Clinton ESP Site), LBP-05-19, 62 NRC 134, 163 (2005) (finding that the requirements for a good cause showing under 10 C.F.R. § 2.309(c)(1)(i) "are analogous to the requirements of Sections 2.309(f)(2)(i) (information not previously available) and (f)(2)(iii) (submitted in a timely fashion)").

85 See Commonwealth Edison Co. (Braidwood Nuclear Station, Units I & 2), CLI-86-8, 23 NRC 241,244 (1986).

86 See New Contentions at 47.

87 See 10 C.F.R. § 2.309(c)(l)(ii)-(iv) (addressing the nature of petitioners' right to be made a party, nature and extent of petitioners' property, financial, or other interests, and the effect of any order on such interests).

88 10 C.F.R. § 2.309(c)(l)(v)-(vi) 89 See New Contentions at 47.

to the IPEC ISFSI, which is subject to separate licensing and regulatory processes under 10 C.F.R. Part 72 that offer appropriate opportunities for public involvement .90 As to the seventh factor (potential to broaden the issues and delay the proceeding),

Petitioners assert that delay is "preferable to violating NEPA."91 But Petitioners' safety contentions are not even covered by this allegation. Factor seven, therefore, also cuts against Petitioners because the introduction of such new issues at this late stage of the proceeding will unnecessarily broaden the issues and may delay the proceeding, contrary to Section 2.309(c)(1)(vii). Further, contrary to Petitioners' assertion that the record is insufficient, the proposed new safety contentions are fundamentally unsupported and the allegations in them have been previously considered and uniformly rejected in the recent Waste Confidence Rulemaking and in other proceedings, 92 so litigation of them would be unlikely to assist in developing a sound record, contrary to Section 2.309(c)(1)(viii). Thus, Petitioners would not assist in the development of a sound record. Accordingly, a balancing of the factors in 10 C.F.R.

§ 2.3 09(c)(1) strongly weighs against admission of the New Contentions.

2. ClearwaterSC-2 (Riverkeeper TC-3) Does Not Specifically State the Issue of Law or Fact to Be Raised and Fails to Explain the Basis and Support for the Contention,As RequiredBy 10 C.F.R. ý' 2.309(f)(1)(i, (ii), and (v)

CW SC-2/RK TC-3 claims that there is an "insufficient analysis of the aging management of the dry casks and spent fuel pools that could be used to store waste on the site in the long term" 93 However, other than a few general references to aging of dry casks and spent fuel pools, Clearwater and Riverkeeper fail to identify the particular issues of law or fact to be 90 See Section IV.C, below.

91 New Contentions at 47.

92 See Section IV.B.2, below.

93 New Contentions at 18.

raised in this proceeding. 94 Specifically, Petitioners provide no basis for any safety concerns-either by way of references to Entergy's LRA or to any potentially applicable regulations-that are sufficient to warrant admission of an issue for hearing. Rather, without any further analysis or expert support, Petitioners simply state that an aging management plan is necessary because the spent fuel casks and pools are long-lived, passive components. 95 Petitioners do provide a statement attributed to a Mr. Arnold Gunderson in one footnote, explaining his alleged experience in the design and fabrication of "nuclear fuel racks" using "boroflex"neutron absorber sandwiched between stainless steel.' 96 Mr. Gunderson claims that, between 1981 and 1990, manufacturers of such items did not account for "long term degradation of the boron neutron absorber." 97 His statements, however, refer to his experience many years ago as "Vice President of Nuclear Energy Services", not any analysis done by Entergy in support of its license renewal application. 98 Further, there is no declaration or affidavit of any sort from Mr. Gunderson attached to Petitioners' pleading.

It is fundamental that an "admissible contention must explain, with specificity, particular safety or legal reasons requiring rejection of the contested [application]. "99 Therefore, Petitioners' unsupported, bare-bones assertions regarding the aging management of dry casks 94 See id. at 34 ("because the casks and pools in which some of the spent fuel is already stored... along with ancillary.

equipment like the fuel cladding and the flexible boron wrapping, are long lived passive components that the licensee cannot assume will require no inspection of maintenance [sic] the Applicant must provide an adequate aging management plan"), 35 ("long term degradation of the Boraflex or other wrapping around the fuel assemblies in the spent fuel pool");

36 ("long-term wet storage of spent-fuel in high-density racks does not meet [unspecified] NRC requirements for adequate protection and renders the plant excessively vulnerable to terrorism"); 42 ("the safety contention raises issues about the aging of long-lived passive components, which are at the heart of the relicensing safety review"), 43 ("Entergy has...

failed to put forward any aging management plan for the spent fuel storage casks, for the spent fuel pools themselves, and for associate components, such as the boron wrapping of the fuel assemblies").

95 Id. at 35-36 & n.7.

96 Id. at 35-36 n.7.

97 .Id. at 36 n.7.

98 See id.

99 Dominion Nuclear Conn., Inc. (Millstone Nuclear Power Station, Units 2 & 3), CLI-0 1-24, 54 NRC 349, 359-60 (2001).

and spent fuel pools should be denied for not providing a specific statement of the issue of law or fact to be controverted, and for failing to provide any explanation of the basis of or alleged facts or expert opinion support for the matters they seek to raise, as required by 10 C.F.R.

§ 2.309(f)(1)(i), (ii), and (v).

3. ClearwaterSC-2 (Riverkeeper TC-3) Raises Issues That Are Beyond the Scope of this Proceeding, Under 10 CF.R. . 2.309(0)(l)(iii)

Petitioners' allegation that the LRA contains an "insufficient analysis of the aging management of the dry casks"'00 raises issues outside the scope of a license renewal proceeding under 10 C.F.R. Part 54.101 ISFSIs are licensed and regulated under 10 C.F.R. Part 72 of the NRC's regulations, which provides for two types of ISFSI licenses; site specific licenses and general licenses.102 The IPEC ISFSI operates pursuant to a general license under 10 C.F.R.

§ 72.210.103 Importantly, Part 72 contains its own license renewal provisions for ISFSIs separate and distinct from Part 54. 104 Based on this separate and distinct licensing process, the Commission has ruled that issues related to ISFSIs are outside the scope of Part 54 power reactor license renewal proceedings.10 5 Specifically, in the Palisades license renewal proceeding, the Commission addressed this issue directly:

[T]he dry cask storage facility, or independent spent fuel storage installation ("ISFSI"), is licensed separately from the reactor. The current proceeding concerns the renewal of the reactor operating license pursuant to 10 C.F.R. Parts 51 and 54, and not the ISFSI, 100 New Contentions at 18 (emphasis added).

101 See 10 C.F.R. § 72.210.

102 Compare 10 C.F.R. § 72.40 (providing for site specific ISFSI licenses), with id. § 72.210 (providing for general licenses for ISFSI located at nuclear power plants using NRC-approved casks).

103 See Letter from J.E. Pollock, Entergy, to NRC Document Control Desk, "Indian Point Energy Center Registration of Unit 2 Spent Fuel Cask Use" at 1 (Feb. 5, 2008), availableat ADAMS Accession No. ML080440312 (Entergy Contention NYS-17B Att. 6).

'04 See 10 C.F.R. §§ 72.42(b) (license renewal for site-specific licenses), 72.212(a)(3) (extension of general licenses).

1o5 See Nuclear Mgmt. Co. (Palisades Nuclear Plant), CLI-06-17, 63 NRC 727, 733 (2006); Oconee, CLI-99-1I, 49 NRC at 344 n.4 ("the Commission handles as a separate licensing matter [from license renewal] any applications for an onsite ISFSI. ISFSI licenses are granted under 10 C.F.R. Part 72").

which is licensed pursuant to 10 C.F.R. Part 72. Issues 10 6 involving the ISFSI are, quite simply, separate licensing matters.

Thus, because the IPEC ISFSI is licensed pursuant to 10 C.F.R. § 72.212 (as was the ISFSI in the Palisades proceeding), such matters are beyond the scope of this proceeding. Accordingly, Petitioners' challenge to the aging management of the spent fuel storage casks are not within the scope of the proceeding, as required by 10 C.F.R. § 2.309(f)(1)(iii).

4. ClearwaterSC-2 (Riverkeeper TC-3) Raises No Genuine Dispute Regarding Enter-a 's Spent Fuel Pool AMPs, As Required By 10 C.F.R. .' 2. 309(t)(1)(vi)

CW SC-2/RK TC-3 also alleges that the LRA contains an "insufficient analysis of the aging management of the ... spent fuel pools." 07 In order to support such a challenge, the Commission has stated that a petitioner must "read the pertinent portions of the license application,... state the applicant's position and the petitioner's opposing view," and explain why it disagrees with the applicant.' 0 8 Thus, a contention that does not directly controvert a position taken by the applicant in the application is subject to dismissal. 109 CW SC-2/RK TC-3 is inadmissible because the LRA contains AMPs related to the spent fuel pools. Specifically, Entergy's LRA includes AMPs for spent fuel pool structural components, including liner plates and gates;I10 concrete structures, including floor slabs, interior walls, and ceilings;"'1 spent fuel storage racks;11 2 and neutron absorbers." 3 By failing to challenge or even reference any of these AMPs, Clearwater fails to directly controvert the LRA.

106 Palisades,CLI-06-17, 63 NRC at 733 (citation. omitted). See also 10 C.F.R. § 72.212(a) (permitting general ISFSI licensees to store spent fuel in approved casks for up to 20 years, a period which can be extended through reapproval).

107 New Contentions at 18 (emphasis added).

108 Final Rule, Rules of Practice for Domestic Licensing Proceedings-Procedural Changes in the Hearing Process, 54 Fed.

Reg. 33,168, 33,170 (Aug. 11, 1989); Millstone, CLI-01-24, 54 NRC at 358.

109 See Oconee, CLI-99-11,49 NRC at 342.

10 LRA Table 3.5.2-3.

III /d.

112 id.

113 Id. Tables 3.3.2-1-IP2, 3.3.2-1-IP3.

CW SC-2/RK TC-3 is similar to the Town of Cortlandt's earlier attempt to challenge AMPs for spent fuel pools. The Board correctly rejected this proposed contention and explained:

Cortlandt contends that Entergy has not submitted an AMP which provides reasonable assurance that SSCs associated with the storage, control, and maintenance of spent fuel will remain capable of fulfilling their intended functions during the proposed extended period of operation. However, Cortlandt offers no analysis of the AMPs included in the LRA, nor does it explain in any way how those plans are deficient. . . . The LRA, however, does include AMPs for spent fuel structural components, and Cortlandt does not discuss or even identify any alleged deficiency with these plans.

. . . . In this proceeding, Cortlandt must identify specific deficiencies in the AMP in order to secure a hearing on the 114 issue.

Similarly, Petitioners fail to identify any specific deficiencies in the AMPs, and thus fails to raise a genuine dispute on a material issue of law or fact, as required by 10 C.F.R. § 2.309(f)(1)(vi).

C. Clearwater EC-9 (Riverkeeper EC-7) and Clearwater SC-3 (Riverkeeper TC-4) Do Not Cure the Defects in Petitioners' First Set of Contentions Recognizing the defects in their first set of proposed contentions, Petitioners proffer two additional contentions intended to cover their "rule valid" scenario.115 Both alternative contentions, CW EC-9/RK EC-7 and CW SC-3/RK TC-4, essentially address the same purported environmental and safety issues raised in CW EC-8/RK EC-6 and CW SC-2/RK TC-3, respectively.11 6 The difference for these contentions is that Petitioners focus on the period 117 commencing 60 years after the date that the license will expire for each IPEC unit.

114 Indian Point, LBP-08-13, 68 NRC at 211-12.

115 New Contentions at 18. Petitioners refer to their first two contentions as covering the "rule invalid" scenario. Id. at 17.

116 See id. at 17-18.

117 See, e.g., id. at 33.

1. Petitioners'Alternative Contentions Suffer From the Same Deliciencies-As the

. InitialSet Both of these alternative contentions suffer from the same deficiencies as the initial set of contentions. Importantly, the limited supporting information Petitioners provide does not

.distinguish between the initial set of safety and environmental contentions and this "alternative" set and therefore, the alternatives are inadmissible for the reasons set forth in response to CW EC-9/RK EC-7 and CW SC-3/RK TC-4, above. Specifically, in the case of CW EC-9/RK EC-7, Petitioners' claims are barred by CLI-10-19, because they impermissibly challenge the amended Waste Confidence Rule, seek to raise NEPA-terrorism claims that are similarly outside the scope of this proceeding, and fail to raise a genuine dispute with the FSEIS." 8 As to CW SC-3/RK TC-4, Petitioners' claims are untimely, equally barred by CLI-10-19, fail to adequately state the issues raised, fail to provide basis or support for the contention, raise issues beyond the scope of 9

this proceeding, and fail to raise a genuine dispute."1

2. There Is No Regulatory Gap RegardingImpacts More than 60 Years Beyond Licensed Life, and to the Extent Any Perceived Gap May Exist, It Is the Subject of An Ongoing'Commission Rulemaking Petitioners assert that under amended Waste Confidence Rule, "the Commission's generic findings with respect to onsite fuel storage in both wet pools and dry casks relate only to the period 60 years beyond the expiration of a plant's operating license."' 20 Based on this, Petitioners assert that CW EC-9/RK EC-7 and CW SC-3/RK TC-4--which seek to.litigate 118 See Section IV.A, above.

119 See Section IV.B, above.

120 New Contentions at 33 (citing 75 Fed. Reg. at 81,033, 81,040). New York echoes these claims in its answer. See New York Answer at 18-22. The key case cited by New York is NaturalResources Def Council,Inc. v. NRC, 539 F.2d 824 (2d Cir. 1976), vacated & remanded,sub nom. Allied-Gen. NuclearServs. v. NaturalRes. Def Council, 434 U.S. 1030 (1978).

In that case, all parties conceded that the draft generic environmental impact statement at issue did not properly address all of the environmental impacts the proposed action. See id. at 842 ("it is apparent that [the draft generic EIS] did not fully address alternatives to plutonium recycle or the special problems of theft, diversion and sabotage"). The Waste Confidence Rule, however, does address the environmental impacts of spent fuel storage, and the Commission's conclusion in that regard is not subject to challenge in this proceeding.

  • environmental and safety issues that relate to the "period commencing 60 years after" the end of the period of extended operation'21-are within the scope of this proceeding.122 In effect, Petitioners claim that there is an apparent regulatory gap because impacts beyond 60 years have not been analyzed by this Commission.

As a threshold matter, of course, this Part 54 proceeding governs license renewal, including the environmental impacts associated with continued operation for only an additional 20 years (i.e., until 2033 for IP2 and 2035 for IP3). The environmental impacts of spent fuel 23 storage beyond 2093 or 2095 are beyond the scope of this proceeding. 1 Moreover, there is no "regulatory gap." The plain text of the amended Section 51.23(a) states that spent fuel "can be stored safely and without significant environmental impacts for at least 60 years beyond licensed life for operation," and goes on to state the Commission's belief that sufficient repository capacity will be available "when necessary."'124 Read together, it is clear from the plain text of the rule that the existing analysis, which extends to at least 60 years 25 beyond the licensed life for operation, is sufficient to address the impacts of spent fuel storage.1 With respect to future actions:

[T]he Commission has confidence that either a repository will be available before the expiration of the 60 years post-licensed life discussed in Finding 4 or that the Waste Confidence Decision and Rule will be updated and revised if the expiration of the 60-year 121 New Contentions at 18.

122 See id. at 20 ("Petitioners have presented alternative contentions that are valid, even if the rules established by the [2010 Waste Confidence Decision] are valid.").

123 New York suggests that the NRC Staff's Safety Evaluation Report ("SER') is required, under the Atomic Energy Act

("AEA") (42 U.S.C. § 2232(a), to make a definitive finding that storing spent fuel at IPEC for more than 60 years "is safe and can be done with adequate protection for the public health and safety. New York Answer at 15. This is incorrect. See NaturalRes. Def Council v. NRC, 582 F.2d 166, 175 (2d Cir. 1978) (holding that under the AEA, "NRC is not required...

to withhold action on pending or future applications for nuclear power reactor operating licenses until it makes a determination that high-level radioactive wastes can be permanently disposed of safely").

124 Emphasis added.

125 And as the Commission has previously explained, "the Court decision that led to the Waste Confidence Proceeding did not require NRC to determine when a repository would be available." Review and Final Revision of Waste Confidence Decision, 55 Fed. Reg. 38,474, 38,477 (Sept. 18, 1990) (citingMinnesota v. NRC, 602 F.2d 412 (DC Cir. 1979)).

period approaches without an ultimate disposal solution for the HLW and SNF.' 26 Thus, contrary to Clearwater and Riverkeeper's contentions, there is simply no regulatory gap beyond 60 years after plant shutdown. The Commission has already held that if it becomes necessary to conduct this evaluation, it has sufficient time to do so over the next 80 years or more.

The NRC has in fact already initiated this evaluation, again following its previous generic approach. As explained in the 2010 Waste Confidence Decision, The Commission, as a separate action, has directed the staff to develop a plan for a longer-term rulemaking and Environmental Impact Statement (EIS) to assess the environmental impacts and safety of long-term SNF and HLW storage beyond 120 years (SRM-SECY-09-0090; ADAMS Accession Number ML102580229). This analysis will go well beyond the current analysis that supports at least 60 years of post-licensed life storage with eventual disposal in a deep geologic repository. 127 In other words, the long-term environmental impacts of long-term spent fuel storage, well beyond the term covered by the amended Waste Confidence Rule, is now the subject of a Commission rulemaking initiative. As the Commission recently reiterated in this proceeding,

"[u]nder longstanding NRC policy, licensing boards 'should not accept in individual license proceedings contentions which are (or are about to become) the subject of general rulemaking by the Commission.""1 28 Thus, Petitioners' desire to litigate its perceived gap in the new 10 C.F.R.

§ 51.23(a) is well outside the scope of this proceeding and must be dismissed.

126 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,043 (emphasis added).

127 Id. at 81,040 (emphasis added).

128 CLI-10-19, slip op. at 2-3 (quoting Oconee, CLI-99,1 1,49 NRC at 345) (emphasis added). In Oconee, the Commission held that, although the topic petitioners sought to raise was not governed by a current rule, the issuance of a Staff Requirements Memorandum ("SRM") for the NRC Staff to initiate a rulemaking on the topic was sufficient to preclude the topic from litigation in individual licensing proceedings. See 49 NRC at 345-56. The rulemaking on the very long-term impacts of spent fuel storage is currently at the same stage. See 2010 Waste Confidence Decision, 75 Fed. Reg. at 81,040.

Accordingly, for this additional reason CW EC-9/RK EC-7 and CW SC-3/RK TC-4 are outside the scope of this proceeding and must be dismissed.

V. CONCLUSION For the reasons set forth above, Clearwater and Riverkeeper's new contentions are inadmissible and should be dismissed in their entirety.

CERTIFICATION OF COUNSEL UNDER 10 C.F.R. § 2.323(b)

Counsel for Entergy certifies that he has made a sincere effort to make himself available to listen and respond to the moving parties, and to resolve the factual and legal issues raised in the motion, and that his efforts to resolve the issues have been unsuccessful.

Resp tfulysbitd William C. Dennis, Esq. Kathryn M. Sutton, Esq.

Entergy Nuclear Operations, Inc. Paul M. Bessette, Esq.

440 Hamilton Avenue Martin J. O'Neill, Esq.

White Plains, NY 10601 MORGAN, LEWIS & BOCKIUS LLP Phone: (914) 272-3202 1111 Pennsylvania Avenue, N.W.

Fax: (914) 272-3205 Washington, D.C. 20004 E-mail: wdennis@entergy.com Phone: (202) 739-5738 Fax: (202) 739-3001 E-mail: ksutton@morganlewis.com E-mail: pbessette@morganlewis.com E-mail: martin.oneill@morganlewis. com COUNSEL FOR ENTERGY NUCLEAR OPERATIONS, INC.

Dated in Washington, D.C.

this 18th day of February 2011

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of .) Docket Nos. 50-247-LR and

) 50-286-LR ENTERGY NUCLEAR OPERATIONS, INC. )

)

(Indian Point Nuclear Generating Units 2 and 3)

) February 18, 2011 CERTIFICATE OF SERVICE I hereby certify that copies of the "Applicant's Answer to Hudson River Sloop Clearwater, Inc.

and Riverkeeper, Inc.'s New Contentions Concerning the Waste Confidence Rule" were served this 18th day of February, 201.1 upon the persons listed below, by first class mail and e-mail as shown below.

Administrative Judge Administrative Judge Lawrence G. McDade, Chair Kaye D. Lathrop Atomic Safety and Licensing Board Panel Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 190 Cedar Lane E.

U.S. Nuclear Regulatory Commission Ridgway, CO 81432 Washington, DC 20555-0001 (E-mail: kdl2(2nrc.gov)

(E-mail: lgrl (@nrc.gov)

Administrative Judge Office of the Secretary*

Richard E. Wardwell Attn: Rulemaking and Adjudications Staff Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Mail Stop: T-3 F23 Washington, D.C. 20555-0001 U.S. Nuclear Regulatory Commission (E-mail: hearingdocket(&nrc.gov)

Washington, DC 20555-0001 (E-mail: rew(d~nrc.gov)

Office of Commission Appellate Adjudication Josh Kirstein, Law Clerk U.S. Nuclear Regulatory Commission Atomic Safety and Licensing Board Panel Mail Stop: 0-16G4 Mail Stop: T-3 F23 Washington, DC 20555-0001 U.S. Nuclear Regulatory Commission (E-mail: ocaamail(dnrc.gov) Washington, DC 20555-0001 (E-mail: Josh.Kirstein(anrc. gov)

Sherwin E. Turk, Esq. Melissa-Jean Rotini, Esq.

Beth N. Mizuno, Esq. Assistant County Attorney David E. Roth, Esq. Office of Robert F. Meehan, Westchester Brian G. Harris, Esq. County Attorney Andrea Z. Jones, Esq. 148 Martine Avenue, 6th Floor Office of the General Counsel White Plains, NY 10601 Mail Stop: 0-15 D21 (E-mail: MJR 1*,)westchestergov.com)

U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: setanrc.gov)

(E-mail: bnml (@nrc.gov)

(E-mail: david.rothmnrc.gov)

(E-mail: brian.harrisa~nrc.gov)

(E-mail: andrea.ionesanrc.gov)

Manna Jo Greene, Environmental Director Thomas F. Wood, Esq.

Stephen C. Filler, Board Member Daniel Riesel, Esq.

Hudson River Sloop Clearwater, Inc. Ms. Jessica Steinberg, J.D.

11 2 Little Market Street Sive, Paget & Riesel, P.C.

Poughkeepsie, NY 12601 460 Park Avenue (E-mail: mannajo(@clearwater.org) New York, NY 10022 (E-mail: sfiller(anylawline.com) (E-mail: drieselasprlaw.com)

(E-mail: jsteinberg(@sprlaw.com)

Joan Leary Matthews, Esq. John Louis Parker, Esq.

Senior Attorney for Special Projects Regional Attorney Office of the General Counsel Office of General Counsel, Region 3 New York State Department of NYS Dept. of Environmental Conservation Environmental Conservation 21 S. Putt Comers Road 625 Broadway, 14th Floor New Paltz, New York 12561-1620 Albany, NY 12207 (E-mail: ilparker(agw.dec.state.nv.us)

(E-mail: jImatthe~gw.dec.state.ny.us)

Ross Gould, Member Michael J. Delaney, V.P. - Energy Hudson River Sloop Clearwater, Inc. New York City Economic Dev. Corp.

270 Route 308 110 William Street Rhinebeck, NY 12572 New York, NY 10038 (E-mail: rgouldesq0(gmail.com) (E-mail: mdelanevanycedc.com)

Phillip Musegaas, Esq. Daniel E. O'Neill, Mayor Deborah Brancato, Esq. James Siermarco, M.S.

Riverkeeper, Inc. Liaison to Indian Point 20 Secor Road Village of Buchanan Ossining, NY 10562 Municipal Building (E-mail: phillipvriverkeeper.org) 236 Tate Avenue (E-mail: dbrancato(iriverkeeper.ora) Buchanan, NY 10511-1298 (E-mail: vobgbestweb.net)

(E-mail: smurray(avillageofbuchanan.com)

Robert D. Snook, Esq. Mylan L. Denerstein, Esq.

Assistant Attorney General Executive Deputy Attorney General, Office of the Attorney General Social Justice State of Connecticut Office of the Attorney General 55 Elm Street of the State of New York P.O. Box 120 120 Broadway, 25th Floor Hartford, CT 06141-0120 New York, New York 10271 (E-mail: Robert. Snook(po.state.ct.us) (E-mail: Mylan.Denersteinaoag.state.ny.us)

John J. Sipos, Esq. Janice A. Dean, Esq.

Charlie Donaldson Esq. Assistant Attorney General Assistants Attorneys General Office of the Attorney General Office of the Attorney General of the State of New York of the State of New York 120 Broadway, 26th Floor The Capitol New York, New York 10271 Albany, NY 12224-0341 (E-mail: Janice.Dean(ioag.state.ny.us)

(E-mail: John.Sipos@iiag.n .gov)

  • Original and 2 copies provided to the Office of the Secretary.

ý7aphael P.Xuyler, Esq.

DBI/66535983.5