{{#Wiki_filter:June 22, 2012  
{{#Wiki_filter:UNITED STATES
EA-12-023  
                                NUCLEAR REGULATORY COMMISSION
                                                REGION I V
                                            1600 EAST LAMAR BLVD
                                        ARLINGTON, TEXAS 76011-4511
                                          June 22, 2012
EA-12-023
David J. Bannister, Vice President
  and Chief Nuclear Officer
Omaha Public Power District
Fort Calhoun Station FC-2-4
P.O. Box 550
Fort Calhoun, NE 68023-0550
Subject:      RESPONSE TO NOTICE OF VIOLATION AND NRC INSPECTION
              REPORT 05000285/2012010
Dear Mr. Bannister:
Thank you for your letter of May 24, 2012, in which you responded to our April 10, 2012, letter
and Notice of Violation regarding deficient modification, inadequate maintenance of the safety-
related 480 Vac electrical distribution system, and failure to maintain in effect all provisions of
the approved fire protection program. We will review the implementation of your corrective
actions during a future inspection to determine that full compliance has been achieved and will
be maintained.
                                              Sincerely,
                                                  /RA/
                                              Geoffrey Miller, Chief
                                              Engineering Branch 2
                                              Division of Reactor Safety
Docket: 50-285
License: DPR-40


  David J. Bannister, Vice President    and Chief Nuclear Officer Omaha Public Power District
D. Bannister                                   -2-
Fort Calhoun Station FC-2-4  P.O. Box 550 Fort Calhoun, NE  68023-0550
Electronic distribution by RIV:
Subject: RESPONSE TO NOTICE OF VIOLATION AND NRC INSPECTION REPORT 05000285/2012010
Regional Administrator (Elmo.Collins@nrc.gov)
Dear Mr. Bannister:
Deputy Regional Administrator (Art.Howell@nrc.gov)
Thank you for your letter of May 24, 2012, in which you responded to our April 10, 2012, letter
DRP Director (Kriss.Kennedy@nrc.gov)
and Notice of Violation regarding deficient modification, inadequate maintenance of the safety-related 480 Vac electrical distribution system, and  failure to maintain in effect all provisions of the approved fire protection program.  We will review the implementation of your corrective actions during a future inspection to determine that full compliance has been achieved and will be maintained.
Acting DRS Director (Tom.Blount@nrc.gov)
Sincerely, 
Acting DRS Deputy Director (Patrick.Louden@nrc.gov)
 
Senior Resident Inspector (John.Kirkland@nrc.gov)
/RA/  Geoffrey Miller, Chief Engineering Branch 2      Division of Reactor Safety
Resident Inspector (Jacob.Wingebach@nrc.gov)
   
Branch Chief, DRP/F (Jeff.Clark@nrc.gov)
Docket:  50-285 License:  DPR-40
Senior Project Engineer, DRP/F (Rick.Deese@nrc.gov)
  UNITED STATESNUCLEAR REGULATORY COMMISSIONREGION IV1600 EAST LAMAR BLVDARLINGTON, TEXAS 76011-4511
Project Engineer, DRP/F (Chris.Smith@nrc.gov)
D. Bannister - 2 - Electronic distribution by RIV: Regional Administrator (Elmo.Collins@nrc.gov) Deputy Regional Administrator (Art.Howell@nrc.gov) DRP Director (Kriss.Kennedy@nrc.gov) Acting DRS Director (Tom.Blount@nrc.gov) Acting DRS Deputy Director (Patrick.Louden@nrc.gov)  
FCS Administrative Assistant (Berni.Madison@nrc.gov)
Senior Resident Inspector (John.Kirkland@nrc.gov) Resident Inspector (Jacob.Wingebach@nrc.gov) Branch Chief, DRP/F (Jeff.Clark@nrc.gov) Senior Project Engineer, DRP/F (Rick.Deese@nrc.gov) Project Engineer, DRP/F (Chris.Smith@nrc.gov)  
Public Affairs Officer (Victor.Dricks@nrc.gov)
FCS Administrative Assistant (Berni.Madison@nrc.gov) Public Affairs Officer (Victor.Dricks@nrc.gov) Public Affairs Officer (Lara.Uselding@nrc.gov) Acting Branch Chief, DRS/TSB (Dale.Powers@nrc.gov) Project Manager (Lynnea.Wilkins@nrc.gov) RITS Coordinator (Marisa.Herrera@nrc.gov) Regional Counsel (Karla.Fuller@nrc.gov)  
Public Affairs Officer (Lara.Uselding@nrc.gov)
Technical Support Assistant (Loretta.Williams@nrc.gov) DRP Admin Assistants (R4DRP_AA@nrc.gov) Congressional Affairs Officer (Jenny.Weil@nrc.gov) OEMail Resource  
Acting Branch Chief, DRS/TSB (Dale.Powers@nrc.gov)
Project Manager (Lynnea.Wilkins@nrc.gov)
   
RITS Coordinator (Marisa.Herrera@nrc.gov)
   
Regional Counsel (Karla.Fuller@nrc.gov)
   
Technical Support Assistant (Loretta.Williams@nrc.gov)
    SUNSI Review Completed: _STG___ ADAMS: X   Yes             Initials: _STG__ X   Publicly Available         X   Non-Sensitive
DRP Admin Assistants (R4DRP_AA@nrc.gov)
          ML SRI:DRS/EB2   C:EB 2 SGraves   GMiller  
Congressional Affairs Officer (Jenny.Weil@nrc.gov)
/RA/   /RA/ 6/13/12   6/20/12 OFFICIAL RECORD COPY T=Telephone           E=E-mail       F=Fax
OEMail Resource
SUNSI Review Completed: _STG___             ADAMS: X Yes         Initials: _STG__
        X Publicly Available                       X Non-Sensitive
                                                                  ML
SRI:DRS/EB2                                                             C:EB 2
SGraves                                                                 GMiller
/RA/                                                                     /RA/
6/13/12                                                                 6/20/12
OFFICIAL RECORD COPY T=Telephone                 E=E-mail F=Fax
}}
}}

Latest revision as of 02:42, 12 November 2019

Acknowledgement Letter to Omaha Public Power District for Their Response to Notice of Violation and NRC Inspection Report 05000285-12-010
ML12174A137
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 06/22/2012
From: Geoffrey Miller
NRC/RGN-IV/DRS/EB-2
To: Bannister D
Omaha Public Power District
References
EA-12-023 IR-12-010
Download: ML12174A137 (2)


See also: IR 05000285/2012010

Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION I V

1600 EAST LAMAR BLVD

ARLINGTON, TEXAS 76011-4511

June 22, 2012

EA-12-023

David J. Bannister, Vice President

and Chief Nuclear Officer

Omaha Public Power District

Fort Calhoun Station FC-2-4

P.O. Box 550

Fort Calhoun, NE 68023-0550

Subject: RESPONSE TO NOTICE OF VIOLATION AND NRC INSPECTION

REPORT 05000285/2012010

Dear Mr. Bannister:

Thank you for your letter of May 24, 2012, in which you responded to our April 10, 2012, letter

and Notice of Violation regarding deficient modification, inadequate maintenance of the safety-

related 480 Vac electrical distribution system, and failure to maintain in effect all provisions of

the approved fire protection program. We will review the implementation of your corrective

actions during a future inspection to determine that full compliance has been achieved and will

be maintained.

Sincerely,

/RA/

Geoffrey Miller, Chief

Engineering Branch 2

Division of Reactor Safety

Docket: 50-285

License: DPR-40

D. Bannister -2-

Electronic distribution by RIV:

Regional Administrator (Elmo.Collins@nrc.gov)

Deputy Regional Administrator (Art.Howell@nrc.gov)

DRP Director (Kriss.Kennedy@nrc.gov)

Acting DRS Director (Tom.Blount@nrc.gov)

Acting DRS Deputy Director (Patrick.Louden@nrc.gov)

Senior Resident Inspector (John.Kirkland@nrc.gov)

Resident Inspector (Jacob.Wingebach@nrc.gov)

Branch Chief, DRP/F (Jeff.Clark@nrc.gov)

Senior Project Engineer, DRP/F (Rick.Deese@nrc.gov)

Project Engineer, DRP/F (Chris.Smith@nrc.gov)

FCS Administrative Assistant (Berni.Madison@nrc.gov)

Public Affairs Officer (Victor.Dricks@nrc.gov)

Public Affairs Officer (Lara.Uselding@nrc.gov)

Acting Branch Chief, DRS/TSB (Dale.Powers@nrc.gov)

Project Manager (Lynnea.Wilkins@nrc.gov)

RITS Coordinator (Marisa.Herrera@nrc.gov)

Regional Counsel (Karla.Fuller@nrc.gov)

Technical Support Assistant (Loretta.Williams@nrc.gov)

DRP Admin Assistants (R4DRP_AA@nrc.gov)

Congressional Affairs Officer (Jenny.Weil@nrc.gov)

OEMail Resource

SUNSI Review Completed: _STG___ ADAMS: X Yes Initials: _STG__

X Publicly Available X Non-Sensitive

ML

SRI:DRS/EB2 C:EB 2

SGraves GMiller

/RA/ /RA/

6/13/12 6/20/12

OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax