PLA-6884, Withdrawal of Proposed Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| issue date = 08/03/2012
| issue date = 08/03/2012
| title = Withdrawal of Proposed Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program
| title = Withdrawal of Proposed Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program
| author name = Helsel J M
| author name = Helsel J
| author affiliation = PPL Susquehanna, LLC
| author affiliation = PPL Susquehanna, LLC
| addressee name =  
| addressee name =  
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:\ I I Jeffrey M. Helsel Nuclear Plant Manager PPL Susquehanna, LLC 7 69 Salem Boulevard Berwick , P A 18603 Tel. 5 7 0.542.3510 Fax 5 7 0.542.1504 \ ' I I I ' \ t I I I .I .. , Pp .l==: ...... TM U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION WITHDRAWAL OF PROPOSED RELIEF REQUEST NO. 3RR-19 TO THE THIRD 10-YEAR INSERVICE INSPECTION PROGRAM FOR SUSQUEHANNA UNITS 1AND2 PLA-6884 Docket Nos. 50-387 and 50-388  
{{#Wiki_filter:Jeffrey M. Helsel                 PPL Susquehanna, LLC                       \    I  I
                                                                                                    .I ..,
Nuclear Plant Manager                      769 Salem Boulevard            \   ' I I     I
                                                                                                '   \   t I I I     ~
                                                                                                  ~~*******~~ ~
Berwick, PA 18603 Tel. 570.542.3510 Fax 570.542.1504 Pp                   .l==:
                                                                                                                  ~  ......
                                                                                                                    ~,    TM U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION WITHDRAWAL OF PROPOSED RELIEF REQUEST NO. 3RR-19 TO THE THIRD 10-YEAR INSERVICE INSPECTION PROGRAM FOR SUSQUEHANNA UNITS 1AND2                                                                             Docket Nos. 50-387 PLA-6884                                                                                      and 50-388


==Reference:==
==Reference:==
Letter (PLA -6847)from J. M. Helsel (PPL) to USNRC (Document Control Desk)
Titled "Proposed Relief Request No. JRR -19 to the Third 10-Year lnservice Inspection Program for Susquehanna SES Units 1 and 2," dated April24, 2012.
In the above referenced letter, PPL Susquehanna, LLC (PPL) requested the approval of Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program for Susquehanna SES Units 1 and 2. This Relief Request proposed the approval of ASME Code Case N-702 for use at Susquehanna SES. BWRVIP-108 is the technical basis used to implement the Code Case. Recent operating experience pointed out that not all design assumptions required for the use of BWRVIP-108 have been taken into consideration by the industry. Most of these assumptions are called out under the Assumptions section of the BWRVIP document. One assumption, however, was found in a later section of the BWRVIP-108 document and was not validated prior to submittal of the Relief Request.
The assumption that was missed is that the number of thermal cycles (start-up and shut down) is assumed to be 40 or less over a 40-year plant life. This assumption is too conservative for most of the BWR fleet and Susquehanna exceeded this number well before its 40-year plant life.
The problem of over-conservatism regarding the number of thermal cycles has been discussed with EPRI. EPRI/BWRVIP is working to correct/revise the BWRVIP-108 document so that it reflects a more realistic plant thermal cycle. At this time, there is no timeframe established for revision and publication of a revised BWRVIP-108 document.
Since design assumption on the number of thermal cycles has been exceeded, PPL requests that proposed Relief Request No. 3RR-19 be withdrawn.


Letter (PLA-6847)from J. M. Helsel (PPL) to USNRC (Document Control Desk) Titled "Proposed Relief Request No. JRR-19 to the Third 10-Year lnservice Inspection Program for Susquehanna SES Units 1 and 2," dated April24, 2012. In the above referenced letter, PPL Susquehanna, LLC (PPL) requested the approval of Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program for Susquehanna SES Units 1 and 2. This Relief Request proposed the approval of ASME Code Case N-702 for use at Susquehanna SES. BWRVIP-108 is the technical basis used to implement the Code Case. Recent operating experience pointed out that not all design assumptions required for the use of BWRVIP-108 have been taken into consideration by the industry.
Document Control Desk PLA-6884 If you have any questions or require additional information, please contact Mr. John L. Tripoli, Nuclear Regulatory Affairs Manager, at (570) 542-3100.
Most of these assumptions are called out under the Assumptions section of the BWRVIP document.
One assumption, however, was found in a later section of the BWRVIP-108 document and was not validated prior to submittal of the Relief Request. The assumption that was missed is that the number of thermal cycles (start-up and shut down) is assumed to be 40 or less over a 40-year plant life. This assumption is too conservative for most of the BWR fleet and Susquehanna exceeded this number well before its 40-year plant life. The problem of over-conservatism regarding the number of thermal cycles has been discussed with EPRI. EPRI/BWRVIP is working to correct/revise the BWRVIP-108 document so that it reflects a more realistic plant thermal cycle. At this time, there is no timeframe established for revision and publication of a revised BWRVIP-108 document.
Since design assumption on the number of thermal cycles has been exceeded, PPL requests that proposed Relief Request No. 3RR-19 be withdrawn. Document Control Desk PLA-6884 If you have any questions or require additional information, please contact Mr. John L. Tripoli, Nuclear Regulatory Affairs Manager, at (570) 542-3100.
Copy: NRC Region I Mr. P. W. Finney, NRC Sr. Resident Inspector Ms. C. J. Sanders, RC Project Manager Mr. L. J. Winker, DEP/BRP}}
Copy: NRC Region I Mr. P. W. Finney, NRC Sr. Resident Inspector Ms. C. J. Sanders, RC Project Manager Mr. L. J. Winker, DEP/BRP}}

Latest revision as of 01:11, 12 November 2019

Withdrawal of Proposed Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program
ML12216A095
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 08/03/2012
From: Helsel J
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PLA-6884
Download: ML12216A095 (2)


Text

Jeffrey M. Helsel PPL Susquehanna, LLC \ I I

.I ..,

Nuclear Plant Manager 769 Salem Boulevard \ ' I I I

' \ t I I I ~

~~*******~~ ~

Berwick, PA 18603 Tel. 570.542.3510 Fax 570.542.1504 Pp .l==:

~ ......

~, TM U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION WITHDRAWAL OF PROPOSED RELIEF REQUEST NO. 3RR-19 TO THE THIRD 10-YEAR INSERVICE INSPECTION PROGRAM FOR SUSQUEHANNA UNITS 1AND2 Docket Nos. 50-387 PLA-6884 and 50-388

Reference:

Letter (PLA -6847)from J. M. Helsel (PPL) to USNRC (Document Control Desk)

Titled "Proposed Relief Request No. JRR -19 to the Third 10-Year lnservice Inspection Program for Susquehanna SES Units 1 and 2," dated April24, 2012.

In the above referenced letter, PPL Susquehanna, LLC (PPL) requested the approval of Relief Request No. 3RR-19 to the Third 10-Year Inservice Inspection Program for Susquehanna SES Units 1 and 2. This Relief Request proposed the approval of ASME Code Case N-702 for use at Susquehanna SES. BWRVIP-108 is the technical basis used to implement the Code Case. Recent operating experience pointed out that not all design assumptions required for the use of BWRVIP-108 have been taken into consideration by the industry. Most of these assumptions are called out under the Assumptions section of the BWRVIP document. One assumption, however, was found in a later section of the BWRVIP-108 document and was not validated prior to submittal of the Relief Request.

The assumption that was missed is that the number of thermal cycles (start-up and shut down) is assumed to be 40 or less over a 40-year plant life. This assumption is too conservative for most of the BWR fleet and Susquehanna exceeded this number well before its 40-year plant life.

The problem of over-conservatism regarding the number of thermal cycles has been discussed with EPRI. EPRI/BWRVIP is working to correct/revise the BWRVIP-108 document so that it reflects a more realistic plant thermal cycle. At this time, there is no timeframe established for revision and publication of a revised BWRVIP-108 document.

Since design assumption on the number of thermal cycles has been exceeded, PPL requests that proposed Relief Request No. 3RR-19 be withdrawn.

Document Control Desk PLA-6884 If you have any questions or require additional information, please contact Mr. John L. Tripoli, Nuclear Regulatory Affairs Manager, at (570) 542-3100.

Copy: NRC Region I Mr. P. W. Finney, NRC Sr. Resident Inspector Ms. C. J. Sanders, RC Project Manager Mr. L. J. Winker, DEP/BRP