Line 1: |
Line 1: |
| #REDIRECT [[CNL-13-111, Registration of Use of Cask to Store Spent Fuel]] | | {{Adams |
| | | number = ML13296A022 |
| | | issue date = 10/18/2013 |
| | | title = Registration of Use of Cask to Store Spent Fuel |
| | | author name = Shea J W |
| | | author affiliation = Tennessee Valley Authority |
| | | addressee name = |
| | | addressee affiliation = NRC/Document Control Desk, NRC/NMSS/SFST |
| | | docket = 05000259, 05000260, 05000296, 07201014 |
| | | license number = DPR-033, DPR-052, DPR-068 |
| | | contact person = |
| | | case reference number = CNL-13-111 |
| | | document type = Letter, License-Application for Certificate of Compliance (Amend/Renewal/Rev) DKT 71 QA Program |
| | | page count = 2 |
| | }} |
| | |
| | =Text= |
| | {{#Wiki_filter:Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-13-111 October 18, 2013 10 CFR 72.4 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296 |
| | |
| | ==Subject:== |
| | Registration of Use of Cask to Store Spent Fuel In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 72.212,"Conditions of General License Issued Under §72.210," paragraph (b)(2), Tennessee Valley Authority (TVA) is submitting the registration for the use of two spent fuel storage casks under the general license to store spent fuel at the Browns Ferry Nuclear Plant (BFN)Independent Spent Fuel Storage Installation. |
| | The initial use of the first cask listed below, to store spent fuel, occurred on September 20, 2013. In accordance with 10 CFR 72.212, this registration is required to be submitted within 30 days of initial use. Accordingly, this submittal is due by October 21, 2013.Pursuant to 10 CFR 72.212(b)(2), TVA is providing the following cask loading information: |
| | Licensee Name: Licensee Address: Tennessee Valley Authority Post Office Box 2000 Decatur, Alabama 35609-2000 DPR-33, DPR-52, and DR-68 50-259, 50-260, 50-296 Reactor License Numbers: Reactor Docket Numbers: Printed on recycled paper U.S. Nuclear Regulatory Commission Page 2 October 18, 2013 Responsible Individual: |
| | Cask Certificate Number: Cask Model Number: Thomas A. Hess Program Manager, Corporate Nuclear Licensing 1014, Amendment 5 Holtec International, HI-STORM 100S For the cask system placed in service on September |
| | : 20. 2013: Cask Identification Numbers Multi-Purpose Canister Type 68, Serial No. 0326 Overpack Serial No. 0493 For the cask system placed in service on September 30, 2013: Cask Identification Numbers Multi-Purpose Canister Type 68, Serial No. 0324 Overpack Serial No. 0497 There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact T. A. Hess at (423) 751-3487.Res ully, ic ear e c i ce resident, Nuclear Licensing cc: NRC Regional Administrator |
| | -Region II}} |
|
---|
Category:Letter
MONTHYEARIR 05000259/20240102024-11-12012 November 2024 Design Basis Assurance Inspection Program Inspection Report 05000259/2024010 and 05000260/2024010 and 05000296/2024010 ML24309A2872024-11-0404 November 2024 International, HI-STORM 100 Amendment 19 Responses to Requests for Additional Information IR 05000259/20240032024-11-0404 November 2024 Integrated Inspection Report 05000259/2024003 and 05000260/2024003 and 05000296/2024003 CNL-24-043, Application for Subsequent Renewed Operating Licenses, Second Safety Supplement2024-11-0101 November 2024 Application for Subsequent Renewed Operating Licenses, Second Safety Supplement ML24305A1692024-10-31031 October 2024 Site Emergency Plan Implementing Procedure Revision 05000259/LER-2024-003, Valid Specified System Actuation Caused the Automatic Start of Emergency Diesel Generators2024-10-29029 October 2024 Valid Specified System Actuation Caused the Automatic Start of Emergency Diesel Generators 05000259/LER-2024-001-02, Secondary Containment Isolation Valve Inoperable Due to Mechanical Failure2024-10-28028 October 2024 Secondary Containment Isolation Valve Inoperable Due to Mechanical Failure ML24299A2632024-10-25025 October 2024 Response to Apparent Violation in NRC Inspection Report 05000260/2024090, EA-24-075 ML24289A1232024-10-24024 October 2024 Letter to James Barstow Re Environmental Scoping Summary Report for Browns Ferry CNL-24-074, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-10-23023 October 2024 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions ML24308A0042024-10-16016 October 2024 Ahc 24-1578 Environmental Review of the Browns Ferry Nuclear Plant, Units 1, 2 and 3 Subsequent License Renewal Application Limestone County AEP-NRC-2024-80, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2024-10-15015 October 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask ML24274A3032024-10-0909 October 2024 Amendment 19 to Certificate of Compliance 1014 for Hi-Storm 100 Multi-Purpose Canister Storage System Request for Additional Information CNL-24-077, Application for Subsequent Renewed Operating Licenses, Response to Request for Additional Information, Set 12024-10-0909 October 2024 Application for Subsequent Renewed Operating Licenses, Response to Request for Additional Information, Set 1 ML24240A1182024-10-0808 October 2024 0 Issuance Letter Amendment 18 to Renewed Certificate of Compliance No. 1014 for the HI-STORM 100 Cask System SVP-24-059, Correction to Registration of Use of Casks to Store Spent Fuel2024-10-0404 October 2024 Correction to Registration of Use of Casks to Store Spent Fuel ML24270A2162024-09-27027 September 2024 Notice of Intentions Regarding Preliminary Finding from NRC Inspection Report 05000260/2024090, EA-24-075 AEP-NRC-2024-79, Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask2024-09-26026 September 2024 Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask ML24262A1502024-09-24024 September 2024 Requalification Program Inspection - Browns Ferry Nuclear Plant CNL-24-060, Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description2024-09-24024 September 2024 Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description ML24262A0602024-09-23023 September 2024 Summary of August 19, 2024, Meeting with Tennessee Valley Authority Regarding a Proposed Supplement to the Tennessee Valley Authority Nuclear Quality Assurance Plan ML24263A2062024-09-19019 September 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for LaSalle County Station - Holtec MPC-68MCBS ML24263A2952024-09-19019 September 2024 Site Emergency Plan Implementing Procedure Revision CNL-24-065, Tennessee Valley Authority – Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-09-18018 September 2024 Tennessee Valley Authority – Central Emergency Control Center Emergency Plan Implementing Procedure Revisions IR 05000260/20240902024-09-17017 September 2024 NRC Inspection Report 05000260/2024090 and Preliminary White Finding and Apparent Violation - 1 CNL-24-062, Cycle 16 Reload Analysis Report2024-09-16016 September 2024 Cycle 16 Reload Analysis Report NL-24-0351, – ISFSI - Registration of Spent Fuel Cask Use2024-09-13013 September 2024 – ISFSI - Registration of Spent Fuel Cask Use ML24255A8862024-09-10010 September 2024 Core Operating Limits Report for Cycle 16 Operation, Revision 0 ML24239A3332024-09-0303 September 2024 Full Audit Plan IR 05000259/20244042024-09-0303 September 2024 Cyber Security Inspection Report 05000259/2024404 and 05000260-2024404 and 05000296/2024404-Cover Letter IR 05000259/20240052024-08-26026 August 2024 Updated Inspection Plan for Browns Ferry Nuclear Plant, Units 1, 2 and 3 - Report 05000259/2024005, 05000260/2024005 and 05000296/2024005 ML24225A1682024-08-16016 August 2024 – Notification of Inspection and Request ML24222A8592024-08-0909 August 2024 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Request ML24221A2702024-08-0808 August 2024 Unit 2 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Cask AEP-NRC-2024-62, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-08-0707 August 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask ML24219A0272024-08-0606 August 2024 Response to NRC Regulatory Issue Summary 2024-01, Preparation and Scheduling of Operator Licensing Examinations IR 05000259/20244022024-08-0606 August 2024 Security Baseline Inspection Report 05000259/2024402 and 05000260/2024402 and 05000296/2024402 IR 05000259/20240022024-08-0202 August 2024 Brown Ferry Nuclear Plant – Integrated Inspection Report05000259/2024002 and 05000260/2024002 and 05000296/2024002 SVP-24-048, Registration of Use of Casks to Store Spent Fuel2024-07-31031 July 2024 Registration of Use of Casks to Store Spent Fuel ML24178A4312024-07-29029 July 2024 Issuance of Certificate of Compliance No. 1014, Amendment No. 16 for the HI-STORM 100 Cask System, Cover Letter ML24199A0012024-07-22022 July 2024 Clarification and Correction to Exemption from Requirement of 10 CFR 37.11(c)(2) ML24172A1342024-07-15015 July 2024 Exemptions from 10 CFR 37.11(C)(2) (EPID L-2023-LLE-0024) - Letter ML24183A4142024-07-10010 July 2024 – License Renewal Regulatory Limited Scope Audit Regarding the Environmental Review of the License Renewal Application (EPID Number: L-2024-SLE-0000) (Docket Numbers: 50-259, 50-260, and 50-296) AEP-NRC-2024-56, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-07-0808 July 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask 05000296/LER-2024-003, Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints2024-07-0808 July 2024 Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints 05000259/LER-2024-001-01, Inoperability of Unit 3 Diesel Generator Due to Relay Failure2024-07-0303 July 2024 Inoperability of Unit 3 Diesel Generator Due to Relay Failure ML24184A1142024-07-0202 July 2024 Site Emergency Plan Implementing Procedure Revision ML24183A3842024-07-0101 July 2024 Registration of Use of Cask to Store Spent Fuel (MPC-364, -365) ML24179A0282024-06-26026 June 2024 Evaluation of Effects of Out-of-Limits Condition as Described in IWB-3720(a) SVP-24-040, Registration of Use of Casks to Store Spent Fuel2024-06-25025 June 2024 Registration of Use of Casks to Store Spent Fuel 2024-09-03
[Table view] Category:License-Application for Certificate of Compliance (Amend/Renewal/Rev) DKT 71 QA Program
MONTHYEARCNL-13-111, Registration of Use of Cask to Store Spent Fuel2013-10-18018 October 2013 Registration of Use of Cask to Store Spent Fuel RS-13-203, Registration of Use of Casks to Store Spent Fuel2013-08-0808 August 2013 Registration of Use of Casks to Store Spent Fuel NL-12-1770, Independent Spent Fuel Storage Installation - Registration of Spent Fuel Cask Use2012-08-22022 August 2012 Independent Spent Fuel Storage Installation - Registration of Spent Fuel Cask Use RS-11-093, Registration of Use of Cask to Store Spent Fuel2011-06-0101 June 2011 Registration of Use of Cask to Store Spent Fuel RS-10-104, Request Registration as User of HI-STORM 100 Cask to Store Spent Fuel2010-06-15015 June 2010 Request Registration as User of HI-STORM 100 Cask to Store Spent Fuel ML0927803142009-09-30030 September 2009 Registration of Use of Cask to Store Spent Fuel RS-09-102, Registration of Use of Cask to Store Fuel2009-07-30030 July 2009 Registration of Use of Cask to Store Fuel RS-09-068, Registration of Use of Cask to Store Spent Fuel2009-05-27027 May 2009 Registration of Use of Cask to Store Spent Fuel ML0618003242006-06-23023 June 2006 Holtec International - Submittal of License Amendment Request #5 to HI-STORM 100 CoC 0CAN040602, Arkansas, Units 1 and 2 - Registration of Cask Use2006-04-25025 April 2006 Arkansas, Units 1 and 2 - Registration of Cask Use 0CAN100502, Arkansas, Units 1 & 2 - Registration of Cask Use2005-10-0707 October 2005 Arkansas, Units 1 & 2 - Registration of Cask Use 2013-08-08
[Table view] |
Text
Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-13-111 October 18, 2013 10 CFR 72.4 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296
Subject:
Registration of Use of Cask to Store Spent Fuel In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 72.212,"Conditions of General License Issued Under §72.210," paragraph (b)(2), Tennessee Valley Authority (TVA) is submitting the registration for the use of two spent fuel storage casks under the general license to store spent fuel at the Browns Ferry Nuclear Plant (BFN)Independent Spent Fuel Storage Installation.
The initial use of the first cask listed below, to store spent fuel, occurred on September 20, 2013. In accordance with 10 CFR 72.212, this registration is required to be submitted within 30 days of initial use. Accordingly, this submittal is due by October 21, 2013.Pursuant to 10 CFR 72.212(b)(2), TVA is providing the following cask loading information:
Licensee Name: Licensee Address: Tennessee Valley Authority Post Office Box 2000 Decatur, Alabama 35609-2000 DPR-33, DPR-52, and DR-68 50-259, 50-260, 50-296 Reactor License Numbers: Reactor Docket Numbers: Printed on recycled paper U.S. Nuclear Regulatory Commission Page 2 October 18, 2013 Responsible Individual:
Cask Certificate Number: Cask Model Number: Thomas A. Hess Program Manager, Corporate Nuclear Licensing 1014, Amendment 5 Holtec International, HI-STORM 100S For the cask system placed in service on September
- 20. 2013: Cask Identification Numbers Multi-Purpose Canister Type 68, Serial No. 0326 Overpack Serial No. 0493 For the cask system placed in service on September 30, 2013: Cask Identification Numbers Multi-Purpose Canister Type 68, Serial No. 0324 Overpack Serial No. 0497 There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact T. A. Hess at (423) 751-3487.Res ully, ic ear e c i ce resident, Nuclear Licensing cc: NRC Regional Administrator
-Region II