MM Log # TXX-7110 d

File # 10110

,=

=

910.3 Ref. # 10CFR50.55(e)

MlELECTRIC wmiam c. counsu December 18, 1987 Executive Vke Presnkat U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555

SUBJECT:

COMANCHE PEAK STEAM. ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 AMBIENT TEMPERATURE EFFECTS ON MSIV ACTUATORS SDAR: CP-87-19 (INTERIM REPORT)

Gentlemen:

l On_ June 11, 1987, we verbally notified your Mr. R. F. Warnick of a deficiency involving the ambient temperature effects on MSIV actuators.

This is an interim rep (ort of a potentially reportable item under the provisions of 10CFR50.55 e). Our latest interim report was logged TXX-6725, dated September 11, 1987.

Our evaluation of this issue is continuing.

We expect to submit our next report by February 26, 1988.

Very truly yours, N. {. {ou H Sl b W. G. Counsil By: