TXX-6948, Forwards Rev 0 to Corrective Action Program Project Status Rept Conduit Supports Train C 2-Inch Diameter & Less. Resolution of Issues Identified in Generic Technical Issues Rept...Resolution of Cygna Train...Issues Included in Rept
| ML20236P554 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 11/11/1987 |
| From: | Counsil W, Woodlan D TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| Shared Package | |
| ML20236P558 | List: |
| References | |
| TAC-R00281, TAC-R281, TXX-6948, NUDOCS 8711180046 | |
| Download: ML20236P554 (1) | |
Text
. _ _ _ _ _ _ _
't E
' Log # TXX-6948
+
File # 10068
=
=-
10010 clo RIELECTRIC u
q wimam c. counsu November 11, 1987 Ewcutive Vkt Presnient y
V. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET N05.'50-445 AND 50-446 TRANSMITTAL OF PROJECT STATUS REPORT FOR 4
CONDUIT SUPPORTS TRAIN C 2 INCH DIAMETER AND LESS Gentlemen:
Enclosed are 15 copies of the Project Status Report for " Conduit Supports Train C 2. Inch Diameter and Less," Revision 0.
The Atomic Safety and Licensing Board will be notified of this transmittal by a separate letter from 1
our attorneys.
Please note that resolution of issues identified in the " Generic Technical Issues Report-Evaluation and Resolution of CYGNA Train A and B Issues as Applicable to Train C Conduit Supports," previously submitted, is' contained in Appendices A and B of the enclosed Project Status Report.
The transmittal ' letter for the " Cable Tray and Cable Tray Hangers Project Status Report" (TXX-6930 dated November 6, 1987) stated that the Atomic Safety and Licensing Board would be provided a copy of the subject report.
By the Board's direction, they only received the transmittal letter and not copies of the Project Status Reports.
Very truly yours, h (o-hth W. G. Counsil 8711100046 871111 PDR ADOCK 05000445 O.
Y-A PDR l
D. R. Woodlan L
Supervisor, Docket Licensing JCH/mgt enclosure
(
c'- Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) lb I
400 North Olive Street LB 81 Dallas, Teus 7$20I l_
I
- - - -..