TXX-6904, Interim Deficiency Rept CP-87-35 Re Raychem Motor Connection Kits.Initially Reported on 870715.Kits NMCK-2V-35-00,Lots K0770 & K1245 Supplied W/Wrong Size Shim.Evaluation of Kit Acceptability Continuing.Next Rept Expected Before 880112

From kanterella
(Redirected from TXX-6904)
Jump to navigation Jump to search
Interim Deficiency Rept CP-87-35 Re Raychem Motor Connection Kits.Initially Reported on 870715.Kits NMCK-2V-35-00,Lots K0770 & K1245 Supplied W/Wrong Size Shim.Evaluation of Kit Acceptability Continuing.Next Rept Expected Before 880112
ML20236H191
Person / Time
Site: Comanche Peak  
Issue date: 10/30/1987
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-87-35, TXX-6904, NUDOCS 8711030505
Download: ML20236H191 (1)


Text

a; -

fWy g

l UfIf d

aW

[f] i. r j[d i,,

& g%

Q 6

Un M

l's. M f""

't1.og' # TXX 6904L Y ^..

FM 2

u

~ File # 10110

~ 908.3e c

Ref f.10CFR50'.55(e).

TUELECTRIC-s Executive Vki President

.0c'tob'ed30,1987 wmiam c. counsu

]

ft, O. S. Nuclear RegulatorytCommission W

s Attn: Document Control De d Washington,10. C 20555 m

s

. w

. a

SUBJECT:

COMANCHE PEAK STEAM ELECT _RIC STATION (CPSES)-

DOCKET NOS. 50-445 AND 50-446 i.

RAYCHEM MOTOR CONNECTIONLKITS SDAR: CP-87-35 (INTERIM REPORT)

H 4

Gentlemen:

t a'

i On July 15, 1987, we verballyIotified your Mr. I. Barnes of a deficiency involving Raychem Motor Connection Ki.ts (Model No'.~.NMCK-2V-35-00)1which'were provided to CPSES with shims whi.ch'may not be. compatible with the use.' range,.

requirements of the supplied bNakout components.

This is'hn!fsterim report i

of a potentially reportable. item under the p'rovis. ions of'10CFR50$(e). - Our.

last interim report was logged TXX-6648, dated: August 13, 1987. $

Motor connection kits are designed to insulate and environmentally s'eal Class

(

1E cable ~ connections to low voltage motors t(pated 1000 volts or less).

The.

A*i kit in question is used when the two conductors'are side by side then. bolted.

To seal this type of assemoly, a breakout, which locks 1.ike'a p' air of;

/

trousers, seals tits legs Laround each conductor,-then a cap is placed.over the assembly.. Since the. niotor conductor is typically _ much 1 smaller than the field cable, a shim is uwd on the motor lead.to increase the -diameter to meet the breakout use range.

n The Raychem Motor Connection Kits NMCK-2V-35-00, Lot' Humber K0770 and K1245.

were supplied with the wrong size shim..1he shim supplied was-.too large and' i

would result in the breakout leg bein'g held.out at a diameterJoutside the qualified use range.

Our evaluation of the acceptability'of these kits is 4

. continuing.

OurnextreportforthisissuewillbesubmittednolaIer~tnaMJanuary-12, 1988.