TXX-6467, Interim Deficiency Rept CP-86-10 Re Electrical Penetration Assemblies Supplied by Bunker Ramo.Initially Reported on 860424.EPA Modules Replaced by Modules Supplied by Conax. Unit 1 Completion Expected by 870730 & Unit 2 by 871130

From kanterella
(Redirected from TXX-6467)
Jump to navigation Jump to search
Interim Deficiency Rept CP-86-10 Re Electrical Penetration Assemblies Supplied by Bunker Ramo.Initially Reported on 860424.EPA Modules Replaced by Modules Supplied by Conax. Unit 1 Completion Expected by 870730 & Unit 2 by 871130
ML20214U061
Person / Time
Site: Comanche Peak  
Issue date: 06/01/1987
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-86-10, TXX-6467, NUDOCS 8706110033
Download: ML20214U061 (1)


Text

E log # TXX-6467 P9 File # 10110 C

908.1

.._.r C

Ref # 10CFR50.55(e) 1UELECTRIC Milliam G. Coumil n oum< n,r,,a.,,,

June 1, 1987 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555

SUBJECT:

COMANCHE PEAX STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 ELECTRICAL PENETRATION ASSEMBLIES SDAR:

CP-86-10 (INTERIM REPORT)

Gentlemen:

On April 24, 1986, we notified you by our letter logged TXX-4774 of a deficiency involving the electrical penetration assemblies (EPA's) supplied by Bunker Rame which we deemed reportable under the provisions of 10CFR50.55(e).

l This is a follow-up interim report submitted to status corrective action implemented to date. Our last interim report, logged TXX-6357, was submitted March 27, 1987.

As noted in previous reports, the EPA modules supplied by Bunker Ramo are being replaced by modules supplied by Conax.

In our letter logged TXX-6262, dated February 27, 1987, concerning Enforcement Action (EA) 86-09, we stated I

that future schedule changes for corrective actions relating to the replacement of these modules would be updated via SDAR-CP-86-10.

Rework is in progress and is currently scheduled for completion by July 30, 1987 for Unit 1 and November 30, 1987 for Unit 2.

We expect to submit our next report by December 18, 1987.

Very truly yours, l

V1 W. G. Counsil BSD/dl c - Mr. R. D. Martin - Region IV Resident Inspectors, CPSES (3) 6*1 8706110033 870601

~

PDR ADOCK 05000445 S

PDR 0

400 North Olise Street Lit 81 Danas, Teus 75201 i

_ _ _, _ _.