Log # TXX-6254 File # 10110 908.1 Re: 10CFR50.55(e)

==

.7 nlELECTRIC N"l)NN,am January 30, 1987 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 CONAX ADAPT 0R MODULES AND ELECTRICAL PENETRATIONS SDAR: CP-86-49 (INTERIM REPORT)

Gentlemen:

On October 10, 1986, we notified you by our letter logged TXX-6018 of a deficiency involving the effects of polar-organic solvents on the sealants of Conax adaptor modules and electrical penetrations which we deemed reportable under the provisions of 10CFR50.55(e). This is an interim report submitted to status corrective action implemented to date. Our most recent interim report was logged TXX-6101 dated November 17, 1986.

Procurement and replacement of the affected modules is continuing.

Replacement of all affected modules is currently scheduled for May 31, 1987. Our next report will be submitted on this issue no later than June 19, 1987.

Very truly yours, h

W1 By:

G. S. Keeley Manager, Nu lear icensing JDS/mlh c - Mr. E. H. Johnson, Region IV Mr. D. L. Kelley, RI - Region IV Mr. H. S. Phillips, RI - Region IV o20 % h 5