s Log # TXX-4649 TEXAS UTILITIES GENERATING COMPANY File # 10010 anywAv rowsm.. wo ru ouva -r==er i..... DAM.AM. TEXA8 783.I 905.2
. MU0diEEr December 16, 1985 Director of Nuclear Reactor Regulation Attention: Mr. Vince S. Noonan, Director Comanche Peak Project Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION DOCKET NOS. 50-445 AND 50-446 FRACTURE TOUGHNESS PROPERTIES OF UNIT 2 REACTOR VESSEL MATERIALS
Dear Mr. Noonan:
Comanche Peak Safety Evaluation Report Supplement I required specific fracture toughness information be provided for Unit 2 Reactor Vessel to confirm compliance with the requirements of Appendix G of 10 CFR Part 50.
Enclosed is WCAP-10684, " Comanche Peak Unit No. 2 Reactor Vessel Surveillance Program", which contains sufficient information to close this confirmatory item.
Very truly yours, OIlO W. G. Counsil BSD/grr Enclosure Original plus 18 copies c-A. Vietti-Cook OI