TXX-4197, Clarifies Scope of 840217 Request for Partial Exemption from GDC 4 Re Consideration of Fluid Discharge (Jet Impingement) Loads in Structural Design
| ML20091M979 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 06/07/1984 |
| From: | Schmidt H TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Youngblood B Office of Nuclear Reactor Regulation |
| References | |
| TXX-4197, NUDOCS 8406120161 | |
| Download: ML20091M979 (1) | |
Text
I i
Log # TXX-4197 I
File # 10035 TEXAS UTILITIES GENERATING COMPANY 903.6 N KYWAY TE RWEH
- 400 NORTIE OI.IVE MTHEET, I..H. Mt
- IBA LI.AN, TEXAM 73281 June 7, 1984 Director, Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 ATTN:
Mr. B. J. Youngblood Division of Licensing Licensing Branch No. 1 SUBJ: COMANCHE PEAK STEAM ELECTRIC STATION UNITS 1 and 2: DOCKET NOS. 50-445 and 50-446 REQUEST FOR PARTIAL EXEMPTION REF:
(a) Letter TXX-4118 from R.J. Gary (TU) to B.J. Youngblood (NRC) dated February 17, 1984 (b) Letter TXX-4159 from H.C. Schmidt (TU) to H.R. Denton NRC, dated April 23, 1984 Gentlemen:
This is to clarify the scope of Texas Utilities' present request for a partial exemption from GDC4 regarding consideration of certain fluid discharge (jet impingement) loads, set forth in our February 17, 1934, letter to you (Ref. (a)) and supplemented by the value-impact analysis transmitted by letter of April 23, 1984 (Ref. (b)). As noted in our February 17 letter, Texas Utilities presently seeks exemption from the need to consider certain jet impingement loads in the design of Unit 1 structures. Specifically, the requested exemption would obviate the need to install those jet shields associated with postulated primary loop pipe breaks in eight (8) locations per loop in Unit 1.
This request does not encompass other shields or restraints already installed in Comanche Peak Units 1 or 2 or yet to be installed in Unit 2.
We recognize that the supporting analyses for our request encompasses other structures in Units 1 and 2.
However, this request is limited to
.the above described scope.
Sincerely, 8406120161 840607 PDR ADOCK 05000445 A
PDR H.C. Schmidt Manager, Nuclear Services HCS/sk V yo I.w.