Text

,-

TEXAS UTILITIES SERVICES INC.

Log # TXX-4009 mu nnus mm:n.n su.wwxa* 7x20i:*a>

File # 906.2 July 19, 1983 Mr. Harold R. Denton Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION DOCKET N0. 50-445 TRANSMITTAL 0F INTEGRATED LEAK RATE TEST REPORT

Dear Mr. Denton:

TXX-3664 dated May 6, 1983 transmitted the CPSES Unit 1 Integrated Leak Rate Test (ILRT) Report required by 10 CFR 50 Appendix J.

The report as transmitted was incomplete pending resolution of one open item.

Enclosed are forty (40) copies of CPSES Unit 1 Integrated Leak Rate Test Addendum which completes the ILRT Report.

Respectfully submitted, H. C. Schmidt BSD: tis Enclosure 8307250256 830719

\\

l PDR ADOCK 05000445 O

\\

A PDR f]CD ll\\

l