TXX-3571, Final Deficiency Rept Re Westinghouse RCS wide-range Pressure Measurements.Initially Reported on 820408.Problem Not Reportable Per 10CFR50.55(e)
| ML20071M350 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 09/15/1982 |
| From: | Gary R TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Madsen G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, TXX-3571, NUDOCS 8209270087 | |
| Download: ML20071M350 (1) | |
Text
TENAS UTILITIES GENERATING COMPANY 2001 IlHYAN TOWl:lt
- DAllAM,TEXAM 7!5201 47,_
',yJ.
.~ u
-L-.. %.
{
R. J. GARY SEP I 6l%2 04 If L':""L':'
f O'l u
L__
September 15, 1982 TXX-3571 Mr. G. L. Madsen, Chief Reactor Projects Branch U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket Nos.
50-445 j
Arlington, TX 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION Westinghouse RCS Wide Range Pressure Measurements File No.:
10110
Dear Mr. Madsen:
On April 8,1982, we verbally informed your Mr. R. G. Taylor of a deficiency regarding Westinghouse RCS wide range pressure measurements. We have sub-mitted interim reports logged TXX-3514 and TXX-3541 dated May 7, 1982 and July 15, 1982 respectively.
We have completed our investigation and concluded that the matter is not -
reportable under 10CFR50.55(e). Records supporting this determination are available for your Inspector's review at the CPSES site.
Very truly yours, YS y R. J. Gary RJG:eaq cc: NRC Region IV - (0 + 1 copy)
Director, Inspection & Enforcement (15 copies)
U. S. Nuclear Regulatory Comission Washington, DC 20555 j
8209270087 820915
)r gDRADOCK 05000445 PDR
..+-y-,.-
,.,r.
. - -.,, - -