TXX-3162, Updates 800421 Deficiency Rept Re Discrepancies Involving Installation & Insp Requirements for Class 5 non-nuclear safety-related Piping Supports.Fsar Is Being Revised.Final Rept Will Be Forwarded by 800922
| ML19320D426 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 07/14/1980 |
| From: | Gary R TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | |
| References | |
| TXX-3162, NUDOCS 8007210352 | |
| Download: ML19320D426 (1) | |
Text
-_
TEXAS UTILITIES GENERATING COMPANY 2001 BHYAN TOWIM = DALLAS. TEXAS 96201 dy]y 14, 198Q R. J. GARY "50" WC0~
-Mr. W. C. Seidie, Chief Reactor Construction & Engineering Support Branch U. S. Nuclear Regulatory Commission Office of Inspection & Enforcement 611 Ryan Plaza Dr., Suite 1000 Docket Nos. 50-445 Arlington, Texas 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION 1981-83 2300 MW INSTALLATION CLASS V PIPING SUPPORTS FILE N0:
10110
Dear Mr. Seidle:
This report updates our letter TXX-3127, dated April 21, 1980, relative to discrepancies involving installation and inspection requirements for Class V non-nuclear safety-related piping supports.
Revisions to both the FSAR and project specifications are being drafted to clarify the CPSES Class V program.
This work activity has been stopped pending a completion of the evaluation.
We anticipate implementing these changes and issuing a final report by September 22, 1980.
Very truly yours, A
R.
. Gary RJG:dk cc: NRC Region IV (0 + 1 copy)
Director, Inspection & Enforcement (15 copies) c/o Distribution Services Branch, DDC, ADM.
4 U. S. Nuclear Regulatory Commission Washington, D. C.
20555 l
800721035~7