TAC:ME0477
From kanterella
(Redirected from TAC:ME0478)
Jump to navigation
Jump to search
Request for: Open | |
Initiation
Results
Other: L-09-268, Calculation, 0800777.309, Rev. 0, Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches)., L-10-132, 0800368.408, Revision 0, Summary of Weld Overlay Ultrasonic Examinations for Reactor Coolant Pump Suction and Discharge Nozzle Welds, Core Flood Nozzle Welds, and Cold Leg Drain Nozzle Welds, L-10-133, Summary of Design and Analysis of Weld Overlays (Mode 4 Report), ML093360324, ML093360325, ML093360326, ML093360327, ML093360328, ML093360329, ML093360330, ML093360331, ML100271531, ML101230640 | |
From | |
MONTHYEARL-09-020, 10 CFR 50.55a Requests for Alternative Dissimilar Metal Weld Repair Methods for Reactor Vessel Nozzles, Reactor Coolant Pump Nozzles, and Reactor Coolant Piping2009-01-30030 January 2009
[table view]10 CFR 50.55a Requests for Alternative Dissimilar Metal Weld Repair Methods for Reactor Vessel Nozzles, Reactor Coolant Pump Nozzles, and Reactor Coolant Piping ML0933603252009-04-0808 April 2009 Calculation, 0800368.311, Rev. 0, Design Loads for the 28 I.D. Reactor Coolant Pump (RCP) Suction and Discharge Nozzles. ML0933603242009-04-21021 April 2009 Calculation, 0800368.301, Rev 0, Material Properties for Davis-Besse Unit 1, RCP Suction, RCP Discharge, Cold Leg Drain and Core Flood Nozzles Preemptive Weld Overlay Repairs. ML0933603272009-05-22022 May 2009 Calculation, 0800368.322, Rev. 1, Finite Element Models of the Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair. ML0933603282009-05-23023 May 2009 Calculation, 0800368.323, Rev. 1, Thermal and Unit Mechanical Stress Analyses for Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair. ML0933603262009-05-27027 May 2009 Calculation, 0800368.320, Rev. 1, Optimized Weld Overlay Sizing for the 28 I.D. Outlet/Discharge Reactor Coolant Pump Nozzle. ML0915301512009-06-11011 June 2009 Request for Additional Information Related to Relief Requests for Alternative Dissimilar Metal Weld Repair Methods for Reactor Vessel Nozzles, Reactor Coolant Pump Nozzles, and Reactor Coolant Piping ML0915504232009-06-15015 June 2009 Request for Additional Information Related to Relief Requests for Alternative Dissimilar Metal Weld Repair Methods for Reactor Vessel Nozzles, Reactor Coolant Pump Nozzles, and Reactor Coolant Piping ML0933603292009-07-10010 July 2009 Calculation, 0800368.324, Rev. 0, Residual Stress Analysis of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair. L-09-179, Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods2009-07-13013 July 2009 Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods ML0933603312009-07-20020 July 2009 Calculation, 0800368.326, Rev. 0, Crack Growth Evaluation of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair. L-09-227, License Amendment Request to Update the Leak-Before-Break Evaluation for the Reactor Coolant Pump Suction and Discharge Nozzle Dissimilar Metal Welds2009-09-28028 September 2009 License Amendment Request to Update the Leak-Before-Break Evaluation for the Reactor Coolant Pump Suction and Discharge Nozzle Dissimilar Metal Welds ML0927205912009-10-0808 October 2009 RAI Related to Relief Requests for Alternative Dissimilar Metal Weld Repair Methods L-09-268, Calculation, 0800777.309, Rev. 0, Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches).2009-11-0202 November 2009 Calculation, 0800777.309, Rev. 0, Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches). ML0933603302009-11-23023 November 2009 Calculation, 0800368.325, Rev. 0, ASME Code, Section Iii Evaluation of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair. ML0933603232009-11-23023 November 2009 Davis-Besse, Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods ML1000400162009-12-15015 December 2009 Relief Request A-32 and A-33 - Request for Additional Information - Supplemental Information ML1000805732010-01-21021 January 2010 Unit, Relief Request RR-A33 for the Application of Full Structural Weld Overlays on Dissimilar Metal Welds of Reactor Coolant Piping ML1002715312010-01-29029 January 2010 Relief Request RR-A32 for the Application of Full Structural Weld Overlays on Dissimilar Metal Welds of Reactor Coolant Piping L-10-132, 0800368.408, Revision 0, Summary of Weld Overlay Ultrasonic Examinations for Reactor Coolant Pump Suction and Discharge Nozzle Welds, Core Flood Nozzle Welds, and Cold Leg Drain Nozzle Welds2010-04-25025 April 2010 0800368.408, Revision 0, Summary of Weld Overlay Ultrasonic Examinations for Reactor Coolant Pump Suction and Discharge Nozzle Welds, Core Flood Nozzle Welds, and Cold Leg Drain Nozzle Welds ML1012306402010-04-29029 April 2010 Davis-Besse, Summary of Weld Overlay Ultrasonic Examinations L-10-133, Summary of Design and Analysis of Weld Overlays (Mode 4 Report)2010-06-18018 June 2010 Summary of Design and Analysis of Weld Overlays (Mode 4 Report) 2009-06-11 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:ME0477&oldid=965944"