Other: L-09-268, Calculation, 0800777.309, Rev. 0, Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches), L-10-132, 0800368.408, Revision 0, Summary of Weld Overlay Ultrasonic Examinations for Reactor Coolant Pump Suction and Discharge Nozzle Welds, Core Flood Nozzle Welds, and Cold Leg Drain Nozzle Welds, L-10-133, Summary of Design and Analysis of Weld Overlays (Mode 4 Report), ML093360324, ML093360325, ML093360326, ML093360327, ML093360328, ML093360329, ML093360330, ML093360331, ML101230640
|
MONTHYEARML0933603252009-04-0808 April 2009 Calculation, 0800368.311, Rev. 0, Design Loads for the 28 I.D. Reactor Coolant Pump (RCP) Suction and Discharge Nozzles Project stage: Other ML0933603242009-04-21021 April 2009 Calculation, 0800368.301, Rev 0, Material Properties for Davis-Besse Unit 1, RCP Suction, RCP Discharge, Cold Leg Drain and Core Flood Nozzles Preemptive Weld Overlay Repairs Project stage: Other ML0933603272009-05-22022 May 2009 Calculation, 0800368.322, Rev. 1, Finite Element Models of the Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair Project stage: Other ML0933603282009-05-23023 May 2009 Calculation, 0800368.323, Rev. 1, Thermal and Unit Mechanical Stress Analyses for Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair Project stage: Other ML0933603262009-05-27027 May 2009 Calculation, 0800368.320, Rev. 1, Optimized Weld Overlay Sizing for the 28 I.D. Outlet/Discharge Reactor Coolant Pump Nozzle Project stage: Other ML0915301512009-06-11011 June 2009 Request for Additional Information Related to Relief Requests for Alternative Dissimilar Metal Weld Repair Methods for Reactor Vessel Nozzles, Reactor Coolant Pump Nozzles, and Reactor Coolant Piping Project stage: RAI ML0915504232009-06-15015 June 2009 Request for Additional Information Related to Relief Requests for Alternative Dissimilar Metal Weld Repair Methods for Reactor Vessel Nozzles, Reactor Coolant Pump Nozzles, and Reactor Coolant Piping Project stage: RAI ML0933603292009-07-10010 July 2009 Calculation, 0800368.324, Rev. 0, Residual Stress Analysis of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair Project stage: Other L-09-179, Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods2009-07-13013 July 2009 Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods Project stage: Response to RAI ML0933603312009-07-20020 July 2009 Calculation, 0800368.326, Rev. 0, Crack Growth Evaluation of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair Project stage: Other ML0927205912009-10-0808 October 2009 RAI Related to Relief Requests for Alternative Dissimilar Metal Weld Repair Methods Project stage: RAI L-09-268, Calculation, 0800777.309, Rev. 0, Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches)2009-11-0202 November 2009 Calculation, 0800777.309, Rev. 0, Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches) Project stage: Other ML0933603302009-11-23023 November 2009 Calculation, 0800368.325, Rev. 0, ASME Code, Section III Evaluation of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair Project stage: Other ML0933603232009-11-23023 November 2009 Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods Project stage: Response to RAI ML1000400162009-12-15015 December 2009 Relief Request A-32 and A-33 - Request for Additional Information - Supplemental Information Project stage: Supplement ML1000805732010-01-21021 January 2010 Unit, Relief Request RR-A33 for the Application of Full Structural Weld Overlays on Dissimilar Metal Welds of Reactor Coolant Piping Project stage: Approval ML1002715312010-01-29029 January 2010 Relief Request RR-A32 for the Application of Full Structural Weld Overlays on Dissimilar Metal Welds of Reactor Coolant Piping Project stage: Approval L-10-132, 0800368.408, Revision 0, Summary of Weld Overlay Ultrasonic Examinations for Reactor Coolant Pump Suction and Discharge Nozzle Welds, Core Flood Nozzle Welds, and Cold Leg Drain Nozzle Welds2010-04-25025 April 2010 0800368.408, Revision 0, Summary of Weld Overlay Ultrasonic Examinations for Reactor Coolant Pump Suction and Discharge Nozzle Welds, Core Flood Nozzle Welds, and Cold Leg Drain Nozzle Welds Project stage: Other ML1012306402010-04-29029 April 2010 Summary of Weld Overlay Ultrasonic Examinations Project stage: Other L-10-133, Summary of Design and Analysis of Weld Overlays (Mode 4 Report)2010-06-18018 June 2010 Summary of Design and Analysis of Weld Overlays (Mode 4 Report) Project stage: Other 2009-06-11
[Table View] |
Text
From: cjheintz@firstenergycorp.com Sent: Tuesday, December 15, 2009 3:08 PM To:
Sands, Stephen Cc:
kmnesser@firstenergycorp.com
Subject:
Re: Relief Requests A-32 and A-33 Attachments:
RR-A32 Page for NRC.pdf; RR-A33 Page for NRC.pdf Stephen-As requested, FENOC's response to the two NRC reviewer questions, in bold font, are as follows:
- 1. Section A1.4(d) of Relief Request RR-A33, Attachment 1, provides requirements for additional examinations when inservice examinations detect defects in overlaid dissimilar metal welds. However, Section A2.3 of Relief Request RR-A32, Attachment 2, does not contain the same requirements for the additional examinations as that of Relief Request RR-A33. Please explain why Relief Request RR-A32 does not contain the same requirements for the additional examinations.
FENOC Response: Request RR-A32 should have the same section as Request RR-A33, entitled "Additional Examinations." FENOC proposes to add the section to RR-A32. See the attached page from RR-A32 that depicts the proposed resolution.
- 2. Section A1.4(d) of Relief Request RR-A33, Attachment 1, references A1.4 (c)(4), which should be A1.4(c)(5).
Please verify if the reference of A1.4(c)(4) is correct.
FENOC Response: The reference within Request RR-A33 should be "A1.4(c)
(5)."
See the attached page from RR-A33 that depicts the proposed resolution.
(See attached file: RR-A32 Page for NRC.pdf)(See attached file: RR-A33 Page for NRC.pdf)
Please advise on the acceptability of these responses.
Cal Heintz Fleet Licensing Fleet Regulatory Affairs FirstEnergy Nuclear Operating Company [FENOC]
440.280.5035 [office] 440.478.9845 [mobile]
CJHeintz@FirstEnergyCorp.com "Sands, Stephen"
<Stephen.Sands@nr c.gov>
To
"'kmnesser@firstenergycorp.com'"
12/15/2009 08:20 <kmnesser@firstenergycorp.com>,
AM "'cjheintz@firstenergycorp.com'"
<cjheintz@firstenergycorp.com>
cc Subject Relief Requests A-32 and A-33 Kathy/Cal:
The reviewer had two follow-on questions that he would like you to respond to listed below:
- 1. Section A1.4(d) of Relief Request RR-A33, Attachment 1, provides requirements for additional examinations when inservice examinations detect defects in overlaid dissimilar metal welds. However, Section A2.3 of Relief Request RR-A32, Attachment 2, does not contain the same requirements for the additional examinations as that of Relief Request RR-A33. Please explain why Relief Request RR-A32 does not contain the same requirements for the additional examinations.
- 2. Section A1.4(d) of Relief Request RR-A33, Attachment 1, references A1.4 (c)(4), which should be A1.4(c)(5).
Please verify if the reference of A1.4(c)(4) is correct.
Please ask the licensee to respond, by email, to the above two questions by today, 12-15-09 if possible.
- Regards, Stephen Sands Division of Operating Reactors Davis-Besse & Perry Project Manager Licensing Project Branch 3-2 Phone: 301-415-3154 E-mail: Stephen.Sands@nrc.gov The information contained in this message is intended only for the personal and confidential use of the recipient(s) named above. If the reader of this message is not
the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify us immediately, and delete the original message.
E-mail Properties Mail Envelope Properties (OFF6274A98.976EA7B1-ON8525768D.006CE661-8525768D.006E92A4)
Subject:
Re: Relief Requests A-32 and A-33 Sent Date:
12/15/2009 3:08:03 PM Received Date:
12/15/2009 3:08:03 PM From:
cjheintz@firstenergycorp.com Created By:
cjheintz@firstenergycorp.com Recipients:
Stephen.Sands@nrc.gov (Sands, Stephen)
Tracking Status: None kmnesser@firstenergycorp.com (kmnesser@firstenergycorp.com)