TAC:66388
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Initiation
Questions Answers | |
| From | |
MONTHYEARML20235F5761987-08-31031 August 1987
[table view]Max Credible Fault Tests CM249-Q2 Carrier Modulator for Fermi 2 Spds. Fault Applied to Output of CM249-Q2 Does Not Cause Degradation of Isolator Input Signal Beyond Acceptable Level NRC-87-0163, Forwards Qualification Test Rept QTR87-018, Max Credible Fault Tests CM249-Q2 Carrier Modulator.... Rept Shows That Fault Originating in non-Class 1E Output Does Not Affect Integrity of Class 1E safety-related Input Signal1987-09-23023 September 1987 Forwards Qualification Test Rept QTR87-018, Max Credible Fault Tests CM249-Q2 Carrier Modulator.... Rept Shows That Fault Originating in non-Class 1E Output Does Not Affect Integrity of Class 1E safety-related Input Signal 1987-08-31 | |