MONTHYEARML13330B2331987-07-15015 July 1987
[table view]Forwards Request for Addl Info Supporting 870325 Submittal Re Transient Torsional Stresses in Crankshafts of Tdi Diesel Engines Uses as Emergency Generators at Plant.Response Requested within 60 Days ML13322A9961989-06-19019 June 1989 Advises That No Planned Maint Sys,Inc Electrical Parts or Components Purchesed by Util Since 850701,per 890522 Request ML13322B0521989-11-21021 November 1989 Forwards Safety Evaluation Re Diesel Generator Crankshaft Crack Propogation.Licensee Must Replace Crankshafts W/Design Not Susceptible to Cracking or Demonstrate Detection Ability of Eddy Current Insp Technique W/High Degree of Confidence ML13322B0991990-02-21021 February 1990 Responds to NRC 891121 Safety Evaluation of Tdi Diesel Crankshaft Oil Hole Cracking Problem at Plant & Advises That Diesel Generator Testing & Analysis Underway to Provide Technical Justification for Increasing 50 start-stop Limit ML13322B1231990-03-23023 March 1990 Advises That Special Repts Re Tdi Diesel Engines Reliability Issues No Longer Required,Per 1989-06-19 | |