MONTHYEARB11677, Advises of Current Plans to Address Requirements of 10CFR50.62,per Generic Ltr 85-06 Re QA Guidance for nonsafety-related ATWS Equipment1985-09-0909 September 1985 Advises of Current Plans to Address Requirements of 10CFR50.62,per Generic Ltr 85-06 Re QA Guidance for nonsafety-related ATWS Equipment A04824, Submits ATWS Rule Schedule Required by 10CFR50.62(d),per Generic Ltr 85-06.Facilities Participating in NRC Integrated Safety Assessment Program.Justification for Absence of Schedules for Haddam Neck & Millstone Unit 1 Provided1985-10-11011 October 1985 Submits ATWS Rule Schedule Required by 10CFR50.62(d),per Generic Ltr 85-06.Facilities Participating in NRC Integrated Safety Assessment Program.Justification for Absence of Schedules for Haddam Neck & Millstone Unit 1 Provided ML20211B3731987-02-12012 February 1987 Provides Info Re Implementation Schedules for Compliance W/Requirements of ATWS Rule (10CFR50.62).NRC Should Be Contacted 30 Days After Ltr Receipt Re Implementation Schedules Using Guidance Provided A06368, Responds to NRC 870212 Request for Addl Info Re Implementation Schedule for Compliance W/Requirements of ATWS rule,10CFR50.62.Mods Will Be Completed by End of Cycle 10 Refueling Outage Scheduled to Begin in June 19891987-03-19019 March 1987 Responds to NRC 870212 Request for Addl Info Re Implementation Schedule for Compliance W/Requirements of ATWS rule,10CFR50.62.Mods Will Be Completed by End of Cycle 10 Refueling Outage Scheduled to Begin in June 1989 ML20210A2441987-05-0101 May 1987 Reconfirms 851011 Proposed Design Mods to Address 10CFR50.62 Requirements,Per 870319 Commitment to Reevaluate Design.Mods Will Be Installed by Cycle 10 Refueling Outage in June 1989. Review of Mods Requested by 870901 B12922, Requests Review & Concurrence on Design Mods Proposed to Address Requirements of ATWS rule,10CFR50.62(d),by 880729. Implementation of Mods Will Be Resheduled If NRC Concurrence Not Obtained by 8807291988-05-27027 May 1988 Requests Review & Concurrence on Design Mods Proposed to Address Requirements of ATWS rule,10CFR50.62(d),by 880729. Implementation of Mods Will Be Resheduled If NRC Concurrence Not Obtained by 880729 A07296, Forwards First Half of Responses to 880608 Request Re ATWS Mods.Remaining Responses Will Be Submitted by 8807121988-06-27027 June 1988 Forwards First Half of Responses to 880608 Request Re ATWS Mods.Remaining Responses Will Be Submitted by 880712 ML20151A4601988-07-11011 July 1988 Forwards Responses to Questions on Proposed ATWS Mods,Per NRC 880608 Request.Spare Parts Will Be Kept for All Dss/Atws Mitigating Sys Actuation Circuitry Components B12980, Clarifies 880627 & 0711 Responses to Questions Re Proposed ATWS Mods Concerning Common Mode Failure Affecting Reactor Protection Sys Power Distribution Sys.Procedure Revised to Assure One Set of Alarms Tested Each Outage1988-07-25025 July 1988 Clarifies 880627 & 0711 Responses to Questions Re Proposed ATWS Mods Concerning Common Mode Failure Affecting Reactor Protection Sys Power Distribution Sys.Procedure Revised to Assure One Set of Alarms Tested Each Outage 1987-05-01
[table view] |