TAC:42964
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Results
Other: ML19352A960, ML20064L282, ML20065C195, ML20070M793, ML20071F068, ML20077J098, ML20082E618, ML20092B933 | |
| From | |
MONTHYEARML19294C8571980-09-0303 September 1980
[table view]Forwards Auxiliary Feedwater Sys Reliability Evaluation & Request for Addl Info ML19352A9601981-05-22022 May 1981 Forwards Responses to NRC Re Auxiliary Feedwater Sys Reliability Analysis Evaluations.Manual Valves in Suction & Discharge of Auxiliary Feedwater Pumps Are Locked & Administratively Controlled ML20064L2821982-05-10010 May 1982 Auxiliary Feedwater Sys Automatic Initiation & Flow Indication (F-16,F-17) ML20058H9131982-08-0303 August 1982 Forwards Application to Amend License NPF-3 Allowing Sway Struts to Replace Snubbers on Relocated Pressurizer Code Safety Valves ML20065C1951982-09-14014 September 1982 Responds to Re Status of NRC Review of Auxiliary Feedwater Sys Reliability Evaluation Conducted Per NUREG-0737,Item II.E.1.1.Comments &/Or Clarification of Position on NRC Status Encl ML20071P6431982-12-15015 December 1982 Responds to NRC Re NUREG-0737,Item II.E.1.1, Auxiliary Feedwater Sys Reliability Evaluation & Request for Util Commitment to Recommendation GS-6.Suggested Changes to Tech Specs Not Warranted ML20070M7931983-01-20020 January 1983 Provides Addl Clarification Re Condensate Storage Tanks. Tanks Are cross-connected,allowing Either Tank to Act as Common Suction Water Supply for Auxiliary Feed Pumps ML20071F0681983-03-11011 March 1983 Responds to NRC Re TMI Item II.E.1.2, Auxiliary Feedwater Sys Automatic Initiation & Flow Indication. Surveillance Requirements Will Be Revised by 830430 to Allow Functional Test on Output Relay Contacts ML20077J0981983-08-0909 August 1983 Responds to Re NUREG-0737,Item II.E.1.1 Auxiliary Feedwater Sys Evaluation. Condensate Storage Tank cross-connect Valves CD163 & CD164,on Drawing M-006A, Will Be Locked Open ML20082E5991983-11-21021 November 1983 Forwards Application for Amend to License NPF-3,requesting Rev to Tech Spec to Remove 480-volt Ac Power from DHR Isolation Valves During Modes 1,2 & 3 When Valves Closed ML20082E6181983-11-21021 November 1983 Proposed Tech Spec Changes,Section 4.5.2.d & Table 3.3-10 Re DHR Isolation Valves ML20082E6141983-11-21021 November 1983 Application for Amend to License NPF-3,revising Tech Spec Section 4.5.2.d & Table 3.3-10 Re Removing 480-volt Ac Power from DHR Isolation Valves During Modes 1,2 & 3 When Valves Closed ML20092B9331984-05-30030 May 1984 Amend 68 to License NPF-3,changing Tech Spec Table 3.3-10, Post-Accident Monitoring Instrumentation, to Specify Two Auxiliary Feedwater Flow Rate Indicators Per Steam Generator 1982-09-14 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:42964&oldid=5497255"