Pages that link to "Burgmeier M"
Jump to navigation
Jump to search
The following pages link to Burgmeier M:
Displayed 25 items.
- ML20028E281 (← links)
- ML20028C836 (← links)
- ML20028C833 (← links)
- 05000220/LER-1983-044-01, /01T-0:on 831128,reactor Bldg Penetration Found Unsealed.Caused by Shrinking of Sealing Matl Forced Out of Penetration Due to Pressure Differential.Fire Watch Established.Penetration Resealed (← links)
- 05000220/LER-1983-040-03, /03L-0:on 831122,main Steam Radiation Monitor 122 Observed Gradually Degrading,Resulting in Low Readings. Caused by Loose Signal Cable Connector & Loss of Detector Sensitivity.Connector & Detector Replaced (← links)
- 05000220/LER-1983-037-03, /03L-0:on 831110,during Routine Surveillance Testing on Core Spray Sys,Leakage from Vent Line Observed on Core Spray Topping Pump 121.Caused by Cracked 3/4-inch Diameter Nipple on Pump Vent Line 121 (← links)
- 05000220/LER-1983-035-03, /03L-0:on 831105,feedwater Pump 12 Removed from Svc Due to Overheating Bearing.Caused by Discharge Check Valve Failure to Close,Resulting in Reverse Rotation of Pump.Valve Seated & Pinion Gears Replaced (← links)
- 05000220/LER-1983-036-03, /03L-0:on 831107,fuel Zone Water Level Monitoring Accurex Sys Found in Idle State.Cause Unknown Suspected That Stop Signal Received Stopping Program.Accurex Logger Restarted & Addl Surveillance Performed (← links)
- 05000220/LER-1983-018-03, /03L-0:on 830709,Agastat Time Delay Relay 11K62A Failed to Time Out at Correct Time & to Initiate Emergency Cooling Sys.Caused by Dirty Timing Orifice.Needle Valve Exercised & Timer Reset (← links)
- 05000220/LER-1983-022-01, /01T-0:on 830721,during Normal Operation,Gap Observed Under Outside Reactor Bldg Track Bay Door.Caused by Failure to Reinstall Removable Seals.Seals Installed. Procedures Reviewed W/Personnel (← links)
- 05000220/LER-1983-015-03, /03L-0:on 830624,while Performing Surveillance Test N1-ISP-RVT on Main Steam Electromatic Relief Valve Tailpipe Temp Sensors,Inputs Indicated Excessive Drift.Cause Unknown.Corrective Action Being Evaluated (← links)
- 05000220/LER-1983-016-03, /03L-0:on 830718,during Normal Operations,Main Steam Line Radiation Monitor 122 Declared Inoperable After Displaying Low Readings Since 830717.Caused by Defective Detector Output Connector on Monitor 122 (← links)
- 05000220/LER-1983-003-04, /04L-0:from 821001-31,lower Limit of Detection (LLD) Sensitivity Not Met for Many Radionuclides During Analysis of Oct Fish Samples.Caused by Higher LLD Values Resulting from Conversion of Wet Weight to Dry Weight Units (← links)
- 05000220/LER-1983-012-03, /03L-0:on 830609,10 Time Delay Relay 11K62 Stuck in Energized Position & Failed to Time Out & Initiate Emergency Cooling Sys.Caused by Dirty Clutch Plunger. Periodic Cleaning of Plunger Initiated (← links)
- 05000220/LER-1983-001-04, /04L-0:on 830122,while Performing Environ Surveillance testing,30 Ft Wind Direction Sensor Alignment Azimuth Indicator Found High.Caused by Improperly Installed Mounting Plate.Sensor Readjusted (← links)
- 05000220/LER-1982-023-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Valve 201.2-71 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valve Will Be Cleaned Followed by Retest (← links)
- 05000220/LER-1982-022-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Leakage from Valves 201.2-27 & 201.2-28 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valves Will Be Cleaned (← links)
- 05000220/LER-1982-021-03, /03L-0:on 821215,while Performing Local Leak Rate Testing,Leakage from Valves 39-11,39-12,39-13 & 39-14 Exceeded Tech Specs.Caused by Dry Packing Condition Resulting from Current Shutdown.Valves Will Be Repacked (← links)
- 05000220/LER-1982-020-03, /03L-0:on 821213,while Performing Local Leak Rate Testing,Leakage from Valves 58.1-01 & 58.1-02 Exceeded Tech Specs.Caused by Valve Order.Existing Order Modified W/Check Valve Followed by Gate Valve (← links)
- 05000220/LER-1983-002-04, /04L-0:on 821018,while Analyzing Quarterly Canal Water Samples,Tritium Concentration in Inlet Sample Was 39.2 Times Control Result.Caused by Normal Intake & Discharge Tunnels Operating in Reverse Flow Mode (← links)
- 05000220/LER-1982-018-03, /03L-0:on 821207,during Maint Outage,Leakage from Valves 68-05 & 68-08 Found Exceeding Tech Specs.Caused by Poor Seal Design.Mods Will Be Completed During Current Outage & Followed by Retest (← links)
- 05000220/LER-1982-017-03, /03L-0:on 821206,during Maint Outage,Leakage from Valves 68-06 & 68-09 Found Exceeding Tech Specs.Caused by Poor Seal Design.Mods Will Be Completed During Current Outage & Followed by Retest (← links)
- 05000220/LER-1983-021-03, /03L-0:on 830720,22,26 & 28,emergency Cooling Sys Loop 11 Taken Out of Svc for Periods Up to 5 H.Caused by Attempt to Reseat Isolation Valve 39-05.Valve Seat Lapped & Loop Returned to Svc (← links)
- 05000220/LER-1983-011-03, /03L-0:on 830604,electromatic Relief Valve 121 Failed to Open.Caused by Dirty Pilot Due to Oxide Buildup During Extended Outage.Pilot Cleaned & Retested & Normal Shutdown Initiated (← links)
- 05000220/LER-1982-019-03, /03L-0:on 821213,while Performing Local Leak Rate Testing,Leakage from Valves 201-09,201-10,201-31 & 201-32 Exceeded Tech Specs.Caused by Poor Seal Design.Vendor Mod Available & Will Be Completed During Current Outage (← links)