- 05000333/LER-1979-102-03, /03L-0:on 791108,reactor Water Conductivity Exceeded Tech Spec Limit.Caused by Decomposition of Ion Exchange Resins Which Altered Ph Level.Eight Condenser Tubes Plugged & One Condensate Demineralizer Removed (← links)
- 05000333/LER-1979-101, Forwards LER 79-101/03L-0 (← links)
- 05000333/LER-1979-031-03, /03L-0 on 790519:fire Door Between North & South Emergency Switch Gear Rooms Failed to Close on Automatic Signal.Door & Closing Mechanism Lubricated & Adjusted (← links)
- 05000333/LER-1979-031, Forwards LER 79-031/03L-0 (← links)
- ML19261D457 (redirect page) (← links)
- 05000333/LER-1979-029 (redirect page) (← links)
- 05000333/LER-1979-105-03, /03L-0:on 791114,during Normal Operation,Noisy Lubricating Oil Recirculating Pump Associated W/Emergency Diesel Generator C Noted.Caused by Bad Bearing in Pump Motor.Motor Replaced (← links)
- 05000333/LER-1979-105, Forwards LER 79-105/03L-0 (← links)
- 05000333/LER-1979-115-03, /03X-1:on 791221,during Normal Operation,Personnel Noted Low Flow Alarms Associated W/Stack Gas Radiation Monitor Sys.Caused by Plugged Sample Line Common to Both Sample Pumps & Monitors.Sample Line Cleared W/Nitrogen (← links)
- 05000333/LER-1979-115, Forwards LER 79-115/03X-1 (← links)
- 05000333/LER-1979-116, Forwards LER 79-116/03L-0 (← links)
- 05000333/LER-1979-113-03, /03L-0:on 791221,while Conducting Core Spray Motor Operated Valve Operability Test,Isolation Valve 14-MOV-11B Would Not Reopen Following Closure.Caused by Motor Pinion Gear Working Loose from Shaft.Gear Replaced (← links)
- 05000333/LER-1979-113, Forwards LER 79-113/03L-0 (← links)
- 05000333/LER-1979-111-03, /03L-0:on 791214,during Instrument Surveillance Procedure F-ISP-9,one of Four High Flow Instruments Found Drifted in Nonconservative Direction.Cause Not Stated. Testing Initiated & Instrument Recalibr (← links)
- 05000333/LER-1979-111, Forwards LER 79-111/03L-0 (← links)
- 05000333/LER-1979-112, Forwards LER 79-112/03L-0 (← links)
- 05000333/LER-1979-109-03, /03L-0:on 791213,during Instrument Surveillance Procedure F-ISP-27,suppression Chamber Temp Recorder 27-TR-102 Found Out of Calibr in Nonconservative Direction. Caused by Failed Printed Circuit Board (← links)
- 05000333/LER-1979-110-03, /03L-0:on 791214,HPCI Sys Steam Supply Inboard Isolation Valve 23-MOV-15 Closed Due to Spurious Isolation Signal.No Cause Found.Isolation Signal Reset & Valve Reopened to Restore HPCI Sys to Operation (← links)
- 05000333/LER-1979-109, Forwards LER 79-109/03L-0 (← links)
- 05000333/LER-1979-110, Forwards LER 79-110/03L-0 (← links)
- 05000333/LER-1979-108-03, /03L-0:on 791206,reactor Core Isolation Cooling Sys Made Inoperable to Inspect Turbine Bearings.Caused by Observation That Bearings Seemed to Be Operating at Excessive Temp.Insp Revealed No Problems (← links)
- 05000333/LER-1979-108, Forwards LER 79-108/03L-0 (← links)
- 05000333/LER-1979-107-03, /03L-0:on 791203,primary Containment Oxygen Analyzer a Indicated Greater than 10% Oxygen Concentration in Primary Containment.Analyzer B Was Out of Svc.Cause Not Stated.Instruments Recalibr & Returned to Svc (← links)
- 05000333/LER-1979-080-01, /01T-0:on 791017,pipe Stress Reanalysis Revealed Pipe Hanger in Fuel Pool Cooling Sys Was Inoperable.Cause Not Stated.Hanger Was Ungraded.Hanger as Modified Is Acceptable.Sys Is Currently Operable (← links)
- 05000333/LER-1979-080, Forwards LER 79-080/01T-0 (← links)
- 05000333/LER-1979-083-03, /03L-0:on 791008,during Normal Operation,Routine Computer Printout of Core Performance Log Indicated That Max Fraction of Limiting Power Density Exceeded 1.000. Reactor Power Immediately Reduced 3% (← links)
- 05000333/LER-1979-083, Forwards LER 79-083/03L-0 (← links)
- 05000333/LER-1979-084-03, /03L-0:on 791009,during Surveillance Test F-ST-5Q, Average Power Range Monitor Channels a & D Tripped at Value Above Tech Spec Max.Caused by Error in Calibr Procedure. Calibr Procedure Revised & Instruments Returned to Svc (← links)
- 05000333/LER-1979-085-01, /01T-0:on 791024,while Performing Pipe Stress Reanalysis,Pipe Support Found Inoperable.Cause Not Stated. Support Will Be Upgraded to Accept Increased Loading Resulting from SHOCK-III Analysis (← links)
- 05000333/LER-1979-078-03, /03L-0:on 791002,reactor Water Instrument 02-3-LIS-72A Was Found Out of Calibr.Caused by Instrument Drift Due to Unknown Causes.Surveillance Increased to Daily Until Switch Is Replaced or Determined Reliable (← links)
- 05000333/LER-1979-078, Forwards LER 79-078/03L-0 (← links)
- 05000333/LER-1979-079-01, /01T-0:on 791010,pipe Support Associated W/Emergency Svc Water Sys B Was Considered Inoperable Per Tech Specs.Cause Not Stated.Existing Support Was Upgraded (← links)
- 05000333/LER-1979-079, Forwards LER 79-079/01T-0 (← links)
- 05000333/LER-1979-081, Forwards LER 79-081/01T-0 (← links)
- 05000333/LER-1979-051-04, /04T-O:on 790829,activity Level of Mn-54 Onsite More than 10 Times Control Location (Offsite) for Same Period.Caused by High Bioaccumulation Factor of Manganese in Fresh Water Mollusks Used in Sample (← links)
- 05000333/LER-1979-051, Forwards LER 79-051/04T-0 (← links)
- 05000333/LER-1979-093-03, /03X-1:on 791021,during Normal Operation,Routine Computer Printout Indicated Core Max Fraction of Limiting Power Density Was 1.003 Over Tech Spec Limit.Power Reduced 2%.Control Rod Pattern Adjusted.Cause Not Reported (← links)
- 05000333/LER-1979-093, Forwards LER 79-093/03X-1 (← links)
- 05000333/LER-1979-098-03, /03L-0:791031,monitor 17-RIS-458B Operated Improperly During Insp & Continuous Inoperable Trip Resulted.Caused by Failure of Inoperable Trip Circuit. Circuit Board Replaced & Instrument Demonstrated Operable (← links)
- 05000333/LER-1979-098, Forwards LER 79-098/03L-0 (← links)
- 05000333/LER-1979-071-01, /01T-0:on 791004,pipe Stress Reanalysis Revealed That Pipe Support H15-124 on Emergency Svc Water Return Piping Was Inoperable.Cause Not Stated.Mod of H15-124 Was Completed within 7-day Time Frame (← links)
- 05000333/LER-1979-071, Forwards LER 79-071/01T-0 (← links)
- 05000333/LER-1979-075-03, /03L-0:on 790915,during Normal Operations,Drywell Equipment Drain Sump Flow Integrator Observed Not Operating While Sump Was Pumped Down Due to Blown Fuse in Integrator Current Power Supply.Fuse Replaced & Sys Tested (← links)
- 05000333/LER-1979-075, Forwards LER 79-075/03L-0 (← links)
- 05000333/LER-1979-073-03, /03L-0:on 790914,while Conducting Operations Surveillance Test,Emergency Diesel Generator C Tripped on Overspeed During Engine Start Sequence.Caused by Loose Connection in Overspeed Limit Switch.Repair Made (← links)
- 05000333/LER-1979-073, Forwards LER 79-073/03L-0 (← links)
- 05000333/LER-1979-057-01, /01T-0:on 790927,as Result of Pipe Stress Reanalysis,Plant Was Notified That Five Pipe Supports Were Considered Inoperable.Caused by Piping Overstress.All Mods & Analyses Performed within Tech Spec Framework (← links)
- 05000333/LER-1979-006-03, /03X-1:on 790124,during Normal Operations,Ground Fault on 125 Station Battery a Noted.Caused by Bellows Failure on Pressure Switch Circuit safety-relief Valve 02-RV-71J.Ground Cleared.Valve Restored to Operation (← links)
- 05000333/LER-1979-006, Forwards LER 79-006/03X-1 (← links)
- 05000333/LER-1979-015, Forwards LER 79-015/03X-1 (← links)