- 05000304/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000295/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000295/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000295/LER-1982-021, Forwards LER 82-021/03L-0 (← links)
- 05000304/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000304/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000295/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000304/LER-1982-014, Forwards LER 82-014/03L-0 (← links)
- 05000304/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- 05000295/LER-1982-024, :on 820730,safety Injection Accumulator Tanks 1B & 1D Transmitters Found Exceeding + or - 4.5% Allowable Tolerance.Caused by Transmitter Drift Due to Hysteresis During Pressurization.Transmitters Recalibr (← links)
- 05000304/LER-1982-017-03, /03L-0:on 820708,during Hot Shutdown & After Taking MSIV 2B Out of Sequence,Msiv Drifted Open & Was Rendered Inoperable.Caused by Failure to Open Drain Valve. Signs Reminding Operators to Verify Drain Position Posted (← links)
- 05000295/LER-1982-023-03, /03L-0:on 820713,during Normal Operation,Conponent Cooling Supply Valve to Pump Oil Cooler & Seal Plate Isolated.Cause Unknown.Component Cooling Alignment Procedure Changed to Require Complete Lineup Check (← links)
- 05000295/LER-1982-022-03, /03L-0:on 820709,low Pressure & High Flow Alarms Received on Zone 1 of Penetration Pressure Sys,Due to Leak in Rupture Disc on Zone 1.Caused of Failure Unknown.Rupture Disc Replaced (← links)
- 05000295/LER-1982-021-03, /03L-0:on 820620,penetration Pressurization Sys Zone 2 Could Not Be Repressurized to Over 32 Psig.Caused by Sheared Internal Float on Zone in-line Flowmeter,Resulting in Float Falling & Restricting Makeup Flow (← links)
- 05000304/LER-1982-016-03, /03L-0:on 820604,logic Relay 518BXA Associated W/Steam Generator 2A low-low Level Reactor Trip for Train a Malfunctioned Nonconservatively.Caused by Plunger Pin Shift Impeding Plunger Movement (← links)
- 05000304/LER-1982-015-03, /03L-0:on 820525 & 29,condenser Offgas Radiation Monitor 2RE-0015 Failed Above Alarm Setpoint.Caused by Condensate Buildup Flooding Detector.Monitor Dried & Detector Replaced.Leakage Problem Under Investigation (← links)
- 05000295/LER-1982-020-03, /03L-0:on 820510,during Refueling Outage,Fuel Bldg Area Radiation Monitor ORE-0005 Alarmed High.Caused by Failed Detector Tube.Tube Replaced & Monitor Calibr (← links)
- 05000304/LER-1982-014-03, /03L-0:on 820511,2A Steam Generator Pressure Comparator 2PC-516A/B Setpoint Found Drifting W/Max Error of -7.5%.Caused by Failure of Input Buffer Amplifier in Comparator.Comparator (Hagan 118) Replaced (← links)
- 05000304/LER-1982-013-03, /03L-0:on 820510,reactor Coolant Loop 2A Overpower delta-T Setpoint Summator 2TC-411E Found out-of-tolerance High by 10.7%.Caused by Sporadic Component Failure within Summator.Summator Replaced (← links)
- 05000304/LER-1982-012-03, /03L-0:on 820510,120-volt Ac Feed Switch to Train A,Div 29 Safeguards Actuating Relays & Train a Safeguards & Blackout Sequence Timers Found in Off Position.Cause Unknown.Mod to Undervoltage Alarm in Progress (← links)
- 05000304/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000295/LER-1982-018-03, /03L-0:on 820422,during Routine Calibr Surveillance,Radiation Monitor ORT-ARO8 for 592-ft Level of Auxiliary Bldg Found Lower than Tech Spec Limit.Cause Unknown.Procedures Being Revised (← links)
- 05000295/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000295/LER-1982-019-03, /03L-0:on 820424,during Calibr Surveillance, Condenser Air Ejector Gas Monitor 1RE0015 Found to Be Reading Low in High Range of Monitor.Cause Unknown.Monitor Recalibr & Radiation Monitor Calibr Procedures Revised (← links)
- 05000295/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000304/LER-1982-011-03, /03L-0:on 820424,during Calibr Surveillance, Condenser Air Ejector Gas Monitor 2RE0015 Found to Be Reading Low in Lower Range.Caused by Failure of High Voltage Power Supply for Monitor to Adjust to within Tolerances (← links)
- 05000304/LER-1982-011, Forwards LER 82-011/03L-0 (← links)
- 05000304/LER-1982-010-03, /03L-0:on 820417,Class I Pipe Tunnel Iodine Radiation Monitor 2RT-PR07B Found Out of Tolerance Low by Approx 1 1/2 Decades.Cause of Low Reading Unknown.Procedures Being Revised to Increase Radiation Monitor Reliability (← links)
- 05000304/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000304/LER-1982-009-03, /03L-0:on 820409,during Test of Auxiliary Feedwater Pumps 2B & 2C,svc Water Valves 2SVSW131 & 2SVSW130 Failed to Open.Caused by Accumulation of Silt from Svc Water Supply.Valves Cleaned & Opened Properly (← links)
- 05000304/LER-1982-009, Forwards LER 82-009/03L-0 (← links)
- 05000295/LER-1982-016-03, /03L-0:on 820405,during Refueling Calibr,Tavg Summator 1TM-412A Found Out of Tolerance.Caused by Insufficient Gain on Summator Hagan 111.Spare Summator Installed & Calibr.Channel Returned to Svc (← links)
- 05000295/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000304/LER-1982-007-03, /03L-0:on 820405,OC Boric Acid Tank Acid Results Indicated 13.5% Concentration.Caused by Erroneous Sample Results.Boric Acid Reduced within Spec (← links)
- 05000304/LER-1982-007, Forwards LER 82-007/03L-0 (← links)
- 05000295/LER-1982-015-03, /03L-0:on 820331,containment Vent Isolation Valve 1AOV-RV0006 Failed to Fully Close Upon Receipt of High Radiation Signal.Caused by Loose Restraint Line.Restraint Line Secured & Valve Successfully Tested (← links)
- 05000295/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000295/LER-1982-017-03, /03L-0:on 820405,loop 1A Reactor Coolant Cold Leg Temp Low Level Amplifier 1TM-411B Failed Low.Caused by Input Ground on Amplifier Hagan 118.Spare Low Level Amplifier Installed & Calibr & Channel Returned to Svc (← links)
- 05000295/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000295/LER-1982-014-13, /13L-0:on 820325,during First Quarter 1982,shift Engineer Received 4.901 Rem Whole Body Dose Equivalent. Caused by Engineer Entering Unsurveyed Area of Reactor Cavity Incore Thimbles in Retracted Position (← links)
- 05000295/LER-1982-014, Forwards LER 82-014/13L-0 (← links)
- 05000304/LER-1982-008-03, /03L-0:on 820407,during Normal operation,011 Battery Charger Tripped & Would Not Stay Reset When Periodic Test 30 Was Performed.Caused by Failure of Overvoltage Thermal Relay.Defective Relay Replaced (← links)
- 05000304/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000295/LER-1982-012-03, /03L-0:on 820305,during Refueling calibr,1D Steam Generator Level Transmitter 1LT-538 Found Out of Tolerance High by Max of 2.8%.Caused by Zero Shift on Transmitter 1LT-538(F/P 13D 2495) (← links)
- 05000295/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000295/LER-1982-013-03, /03L-0:on 820305,loop C & Loop D Reactor Coolant Flow Transmitters 1FT-426 & 1FT-434 Found out-of-tolerance During Refueling Calibr.Caused by Zero Shift.Both Transmitters Recalibr (← links)
- 05000295/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- 05000304/LER-1982-005-03, /03L-0:on 820306,during Cold Shutdown,Steam Pressure Transmitter 2PT-514 Failed High at 4.690-volts Dc. Caused by Condensation Entry Into Transmitter Due to Steam Leak.Leak Repaired & Transmitter Dried,Cleaned & Recalibr (← links)
- 05000304/LER-1982-005, Forwards LER 82-005/03L-0 (← links)
- 05000295/LER-1982-011-01, /01T-0:on 820317,RHR Suction Pressure Transmitter 1PT-403 Failed High & Suction Valve 1MOV-RH8702 Started to Close.Caused by Piece of Sheet Metal Accidentally Dropped on Inverter 111 Output Breaker.Breaker Reclosed (← links)