The following pages link to 05000029/LER-1977-013, Forwards LER 77-013/03L-0:
Displayed 50 items.
- 05000029/LER-1977-033, Forwards LER 77-033/03L-0 (← links)
- 05000029/LER-1977-035-03, /03L-0:on 770627,discovered That Four of Eight Thermocouple Locations on Boron Injection Flow Path Were Less than 150 F.Caused by Leakage from Purification Sys Through Three Valves to SI Tank.Valves Repaired (← links)
- 05000029/LER-1977-033-03, /03L-0:on 770620,discovered That Five of Eight Thermocouple Locations on Boron Injection Flow Path Were Less than 150 F.Caused by Leakage from Purification Sys Through Three Valves to SI Tank.Valves Repaired (← links)
- 05000029/LER-1977-054-03, /03l-0:on 771205,during Surveillance Test Battery Cell of Battery Bank 1 Failed to Meet Acceptance Criteria of Tech Specs.Cause Unknown.Battery Replaced W/Spare & Recharged.Investigation Continuing (← links)
- 05000029/LER-1977-054, Forwards LER 77-054/03l-0.Detailed Event Analysis Encl (← links)
- 05000029/LER-1977-055-03, /03L-0:on 771217,during 12-h Shutdown for Operator Training,Dose Equivalent I-131 Concentration of Primary Coolant Sys Exceeded Tech Spec.Cause Assumed to Be Cladding Defect in Single Fuel Rod (← links)
- 05000029/LER-1977-055, Forwards LER 77-055/03L-0.Detailed Event Analysis Encl (← links)
- 05000029/LER-1977-043-03, /03L-0:on 770810,during Refueling,Pressurized Wide Range Level Scram Setpoint Discovered Out of Tolerance. Caused by Instrument Drift.Setpoints Were Readjusted (← links)
- 05000029/LER-1977-043, Forwards LER 77-043/03L-0 (← links)
- 05000029/LER-1977-041-03, /03L-0:on 780802,during Surveillance Testing, Diesel Generator 1 Overheated & Failed to Meet Acceptance Criteria.Caused by Young Radiator Co Radiator Tubes Being Blocked by Sludge & Scale.Radiator Cleaned (← links)
- 05000029/LER-1977-041, Forwards LER 77-041/03L-0 (← links)
- 05000029/LER-1977-031-03, /03L-0:on 770609,loop Seal Radiation Monitor Pegged at Low End of Scale.Caused by RM-40 Power Supply High Voltage Tripping.Voltage Adjusted (← links)
- 05000029/LER-1977-031, Forwards LER 77-031/03L-0 (← links)
- 05000029/LER-1977-015, Forwards LER 77-015/03L-0 (← links)
- 05000029/LER-1977-002-03, /03L-0:on 770107,during Monthly Test,Inboard Packing Gland of Low Pressure Pump 1 Found to Leak Excessively.Caused by Packing Deterioration.Pump Removed from Svc,Repacked & Satisfactorily Test Run (← links)
- 05000029/LER-1977-002, Forwards LER 77-002/03L-0 (← links)
- 05000029/LER-1977-003-03, /03L-0:on 770110,primary Vent Stack Monitor Particulate Channel Failed to Meet Acceptance Criteria of Channel Functional Test.Caused by Drifting of Instruments High Voltage.High Voltage Adjusted (← links)
- 05000029/LER-1977-003, Forwards LER 77-003/03L-0 (← links)
- 05000029/LER-1977-001, Forwards LER 77-001/03L-0 (← links)
- 05000029/LER-1977-034-03, Testing of Pressurizer Code Safety valves,PR-SV-181 & 182 Found Open at Pressure Higher than Allowable.Caused by Setpoint Drift.Valves Adjusted & Retested to Verify Lifting Pressure (← links)
- 05000029/LER-1977-034, Forwards Updated LER 77-034/03L-0 (← links)
- 05000029/LER-1977-032-03, /03L-0:on 770611,during Surveillance testing,TV- 209 Containment Drain Line Trip Isolation Valve Failed to Close.Caused by Excessively Tightened Packing.Packing Probably Overtightened During Recent Containment Leak Insp (← links)
- 05000029/LER-1977-032, Forwards LER 77-032/03L-0 (← links)
- 05000029/LER-1977-020-03, /03L-0:on 770415,during Paper Replacement in Main Coolant Leakage Vapor Container Air Particulate Monitor Paper Drive Found Inoperative.Caused by Deterioration of Reduction Gears.Reduction Gears Rebuilt & Lubricated (← links)
- 05000029/LER-1977-020, Forwards LER 77-020/03L-0 (← links)
- 05000029/LER-1977-024-03, /03L-0:on 770428,loop Seal Discharge Radioactive Gaseous Monitor Indication Went to Zero.Caused by Drift in RM-40 Power Supply High Voltage.High Voltage Adjusted (← links)
- 05000029/LER-1977-024, Forwards LER 77-024/03L-0 (← links)
- 05000029/LER-1977-026-03, /03L-0:on 770518,control Room Received Low Flow Alarm on Primary Vent Stack Particulate Radiation Monitor Channel.Caused by Paper in Util Being Slightly Oversized & Boundup.New Roll of Paper Installed (← links)
- 05000029/LER-1977-026, Forwards LER 77-026/03L-0 (← links)
- 05000029/LER-1977-028-03, /03L-0:on 770530,noble Gas Monitor of Primary Vent Stack Radiation Detection Sys Failed.Cause Could Not Be Ascertained as Trouble Could Not Be Repeated After Alarm Reset (← links)
- 05000029/LER-1977-028, Forwards LER 77-028/03L-0 (← links)
- 05000029/LER-1977-027-03, /03L-0:on 770524,biannual Recalibr Performed on Two LPIS Accumulator Channels.Instruments Below Tech Specs Limit.Recalibr Adjustments Made to Bring Channels within Tech Specs Limit (← links)
- 05000029/LER-1977-027, Forwards LER 77-027/03L-0 (← links)
- 05000029/LER-1977-018-03, /03L-0:on 770326,steam Generator Chloride Concentration Increased to Max Level of 4 Ppm in Steam Generator 2,exceeding Tech Specs Limit (← links)
- 05000029/LER-1977-018, Forwards LER 77-018/03L-0 (← links)
- 05000029/LER-1977-014-03, /03L-0:on 770308,iodine Channel of Primary Vent Stack Radiation Monitoring Sys Failed to Meet High Level Count Rate Acceptance Criteria.Caused by Voltage Drift. Voltage Adjusted (← links)
- 05000029/LER-1977-014, Forwards LER 77-014/03L-0 (← links)
- 05000029/LER-1977-029-03, /03L-0:on 770603,during Mode 1,primary Vent Stack Radiation Detection Sys Particulate Channel Failed.Caused by Control Setpoint Being Set Too Close Together.Control Setpoint Readjusted (← links)
- 05000029/LER-1977-029, Forwards LER 77-029/03L-0 (← links)
- 05000029/LER-1977-013-03, /03L-0:on 770307,following Power Reduction to Identify Plug Leaking Condenser Tube,Chlorides in Steam Generators 1 & 4 Exceeded Tech Specs Limits.Caused by Chloride Concentration Buildup in Steam Generator (← links)
- ML19345A591 (redirect page) (← links)
- 05000029/LER-1977-013 (redirect page) (← links)
- 05000029/LER-1977-012-03, /03L-0:on 770306,alarm Setpoint Adjustment of Radiation Monitor for Steam Generator Blowdown Found Defective.Caused by Alarm Setpoint Control Failure to Adjust.Control Replaced (← links)
- 05000029/LER-1977-012, Forwards LER 77-012/03L-0 (← links)
- 05000029/LER-1977-011-03, /03L-0:on 770301,emergency Diesel Generator 1 Starter Motor Failed During Surveillance Test.Caused by Armmature Shaft Being Broke.Starting Motor Replaced (← links)
- 05000029/LER-1977-011, Forwards LER 77-011/03L-0 (← links)
- 05000029/LER-1977-010-03, /03L-0:on 770224,light Leakage Found from Weld on Discharge Line of Charging Pump 3 at Inlet to Pump Relief Valve.Caused by Failure of Weld & Pipe Nipple.Piping Sections Replaced (← links)
- 05000029/LER-1977-010, Forwards LER 77-010/03L-0 (← links)
- 05000029/LER-1977-019-03, /03L-0:on 770402,radioactive Gaseous Waste Monitor Loop Seal Discharge Monitor Alarm Failed to Operate.Caused by Alarm Setpoint & Meter Pointer Contacts Being Corroded. Contacts Cleaned,Mylar Film & Protective Tape Replaced (← links)
- 05000029/LER-1977-019, Forwards LER 77-019/03L-0 (← links)