- 05000416/LER-1982-103, Forwards Updated LER 82-103/01X-1 + (16:19:10, 26 May 2025)
- PMNS20200163, Public Meeting to Discuss the Independent Spent Fuel Storage Installation (ISFSI) Inspection Enhancement Initiative Recommendations + (16:20:12, 26 May 2025)
- ML20066L257 + (16:20:33, 26 May 2025)
- 05000327/LER-1982-123, Forwards LER 82-123/03L-0 + (16:21:13, 26 May 2025)
- ML20066K704 + (16:21:43, 26 May 2025)
- 05000266/LER-1982-018-01, /01T-0:on 821015,while Attempting to Shift Yellow Instrument Bus to Alternate Supply,Bus de-energized & Turbine Runback Occurred.Caused by Shifting Wrong Bus Power Supply Due to Misunderstanding.Warning Signs Posted + (16:21:45, 26 May 2025)
- TAC:74026 + (16:21:50, 26 May 2025)
- 05000293/LER-1982-049, Telecopy LER 82-049/01X-0:on 821102,safety Valve a Found Set W/Nitrogen at Steam Relief Setting.Caused by Personnel Error.Properly Tested Spare Valve Installed.Personnel Admonished to Read & Follow Procedures Exactly + (16:21:53, 26 May 2025)
- EPID:L-2020-LLA-0019 + (16:22:01, 26 May 2025)
- 05000458/LER-1990-004, :on 900211,div II Emergency 125-volt Dc Bus Experienced Voltage Spike Causing Topaz Inverter Unit to Trip.Caused by Drift of Inverter High Voltage Trip Setpoint. Inverters Calibr + (16:22:47, 26 May 2025)
- 05000325/LER-1982-136-03, /03L-0:on 821022,during Plant Shutdown,Suppression Pool Level Indicators Operability Test PT-08.1.6 Revealed Levels Exceeding Tech Specs.Caused by Improper Leg Trickle Flow.Leg Trickle Flow Adjusted + (16:23:26, 26 May 2025)
- 05000325/LER-1982-136, Forwards LER 82-136/03L-0 + (16:23:29, 26 May 2025)
- 05000255/LER-1982-033-03, T-82B (B Safety Injection Tank) Level Reached Tech Spec Limit of 198 Inches.Caused by Minor Leakage Past Loop Check Valve & Tank Check Valve or Fill & Drain Valve.Valves Will Be Inspected at Next Outage + (16:24:04, 26 May 2025)
- 05000255/LER-1982-033, Forwards Revised LER 82-033/03X-1 + (16:24:06, 26 May 2025)
- 05000317/LER-1989-016, :on 890908,determined That Resistance Temp Detectors Installed in Hot & Cold Legs of RCS Not Properly Sealed to Prevent Moisture Intrusion.Caused by Inadequate Procedure.Design Manual Revised + (16:24:16, 26 May 2025)
- TAC:64127 + (16:24:21, 26 May 2025)
- ML20066J105 + (16:24:59, 26 May 2025)
- ML20066H337 + (16:26:24, 26 May 2025)
- 05000334/LER-1982-042-03, /03L-0:on 821007,problem W/Leak Collection Ventilation Exhaust Fan VS-F-4B Reported.Caused by Electrical Lead Connection at Motor Being Burnt Off, Disabling One Phase to Motor.Motor Lead Replaced + (16:26:28, 26 May 2025)
- 05000259/LER-1982-084-03, /03L-0:on 821018,reactor Water Level Switches 1 & 2 of LIS-3-203B as-found Calibr Violated Tech Specs. Caused by Instrument Drift.Switches Recalibr,Functionally Tested & Returned to Svc + (16:26:55, 26 May 2025)
- 05000317/LER-1982-059-03, /03L-0:on 821007,reactor Protective Sys Channel D Trip Units for High Power,Thermal Margin/Low Pressure & Axial Shape Index Bypassed for Corrective Maint.Caused by Shorted Indicator Lamp.Lamp Replaced + (16:26:56, 26 May 2025)
- 05000302/LER-1982-066-03, /03L-0:on 821019,routine Surveillance Indicated 33-ft Wind Speed Channel Inoperable.Caused by Instrument Drift.Channel Recalibr & Returned to Svc + (16:27:00, 26 May 2025)
- 05000334/LER-1990-019-01, :on 901226,MSIV Closed During Partial Stroke Testing,Isolating Steam from SG B.Caused by tar-like Matl Accumulation on Valve Test Limit Switch.Switch Replaced & Design Changed to Modify MSIV Test Circuit + (16:27:05, 26 May 2025)
- 05000339/LER-1982-069-03, /03L-0:on 821020,generator Field on 2J Emergency Diesel Generator Failed to Flash During post-preventive Maint Operability Test.Caused by Failure of Generator Field Contractor Latch Trip Coil to Energize.Coil Replaced + (16:27:09, 26 May 2025)
- 05000366/LER-1982-117-03, /03L-0:on 821017,instrument a of Channel a Did Not Trip at Greater than or Equal to 100 Psig During Ft&C Procedure.Caused by Setpoint Drift in Core Spray Pump Discharge Pressure Instrument.Instrument Calibr + (16:27:17, 26 May 2025)
- 05000277/LER-1982-037-03, /03L-0:on 821012,control Rod Drive Area Smoke Detector Circuit Set Off False Alarm.Caused by Stripped Terminal Screw in Auto Code Box & Loose Connection from Circuitry.Screw Replaced & Connection Tightened + (16:27:19, 26 May 2025)
- 05000328/LER-1982-122-03, /03L-0:on 821021,during Mode 1 Operation, Pressurizer Pressure Channel 2-PS-68-323B Declared Defective Due to Loss of Ac Power to Channel.Caused by Defective Fuse Holder Cap.Cap Replaced & Channel Returned to Svc + (16:27:24, 26 May 2025)
- 05000219/LER-1982-047-03, /03L-0:on 821004,loss of Power to Reactor Protection Sys Motor Generator Set 1 Caused Half Scram. Caused by Burned & Scarred Relay Contacts.Relay Replaced & Sys Returned to Svc.Spare Relays on Order + (16:27:27, 26 May 2025)
- 05000374/LER-1990-014-06, :on 901222,smoke Discovered Coming from Front Area of turbine-driven Reactor Feedwater Pump.Caused by Oil Leak on Insulation.Pump Taken off-line for Repair & Vibration Probe Flange Machined + (16:27:29, 26 May 2025)
- 05000334/LER-1982-047-03, /03L-0:on 821013,pressurizer Level Channel I Indicator LI-RC-459 Recorded to Be Out of 4% Tolerance Band. Caused by Leaking Instrument Valve Resulting in Loss of Level in Ref Leg of LT-RC-459.Valve Internals Replaced + (16:27:39, 26 May 2025)
- 05000352/LER-1991-003, :on 910113,loose Parts Monitoring Sys Inoperable for More than 30 Days.On 901205,digital Loose Part Locator Circuit Discovered in Lockup Condition.Caused by Faulty Component.New Circuit Boards Ordered + (16:27:42, 26 May 2025)
- 05000373/LER-1982-128-03, /03L-0:on 821018,standby Gas Treatment Sys Electric Heating Coil 2VG01A Failed to Energize During Performance of LOS-VG-M1,standby Gas Treatment Sys Operability Test.Caused by out-of-calibr Flow Transmitter + (16:27:44, 26 May 2025)
- 05000483/LER-1990-017, :on 901230,reactor Trip Occurred Due to Failure of Controller/Driver Card for Feedwater Regulating Valve B & Valve Closed & Could Not Be Reopened.Caused by Failed Card Capacitor.Card Replaced + (16:27:51, 26 May 2025)
- 05000366/LER-1982-116-03, /03L-0:on 821014,during Full Load Operation, Drywell Hydrogen & Oxygen Analyzer B Found Inoperative. Caused by Failure of Diaphragm Capscrew on Sample Pump Connecting Rod.Capscrew Replaced & Analyzer Recalibr + (16:27:54, 26 May 2025)
- 05000302/LER-1990-020, :on 901227,all Auxiliary Bldg Ventilation Lost. Caused by Inadvertent Jarring of Thermal Switch During Erection of Scaffolding.Switch Reset,Fans Restarted & Ventilation Sys Restored to Normal + (16:27:58, 26 May 2025)
- 05000324/LER-1990-020-02, :on 901226,while Returning HPCI Sys to Svc, Determined That Min Flow Valve Control Power Fuse Blown, Resulting in Inoperability of Valve.Caused by Short in Indicating Light Bulb.Bulb & Fuse Replaced + (16:28:00, 26 May 2025)
- ML20066G636 + (16:28:10, 26 May 2025)
- ML20066G626 + (16:28:18, 26 May 2025)
- 05000254/LER-1990-033, :on 901223,standby Gas Treatment Sys Auto Started,Reactor Bldg & Control Room Ventilation Sys Isolated & drywell-to-torus Purge Fans Tripped.Caused by Blown Fuse in HVAC Isolation Logic.Fuse Replaced + (16:28:31, 26 May 2025)
- 05000348/LER-1991-001, :on 910123,hourly Fire Watch Patrol Required by Tech Spec 3.3.3.9 Not Performed.Caused by Personnel Error. Fire Watch Patrol Established Immediately & Involved Shift Foreman Counseled + (16:28:33, 26 May 2025)
- 05000265/LER-1990-015-05, :on 901221,two HPCI Steam Drain Lines & Supports Found Outside FSAR Allowables for Thermal & Seismic Loadings.Caused by Inadequate Original Seismic Evaluation. Addl Supports Installed + (16:28:38, 26 May 2025)
- 05000354/LER-1990-034-02, :on 901224 & 910107,filtration,recirculation & Ventilation Sys (FRVS) Recirculation Fan Found Running. Caused by Less than Adequate Design of FRVS Fan auto- Initiation Circuitry.Time Delay Installed + (16:28:40, 26 May 2025)
- 05000265/LER-1990-014-05, :on 901220,discovered That Torus Level Sightglass Left Valved in Since 901217.Caused by Personnel Error & Lack of Labeling.Training Enhanced & Event Reviewed During Weekly Safety Meeting + (16:28:41, 26 May 2025)
- ML20066G408 + (16:28:44, 26 May 2025)
- ML20066G042 + (16:28:57, 26 May 2025)
- 05000331/LER-1982-070-03, /03L-0:on 821019,while Reviewing Surveillance Test Procedures,Discovered Monthly Surveillance of Reactor Low Low Level Protection Sys Trip Function Not Performed During Sept.Caused by Personnel Error.Personnel Disciplined + (16:28:59, 26 May 2025)
- ML20066G026 + (16:29:01, 26 May 2025)
- 05000265/LER-1982-020-03, /03L-0:on 821013,drywell to Suppression Pool Differential Pressure Was 0 Psid & Suppression Pool Level Fell Below Tech Spec Limits During Startup.Caused by Personnel Preoccupation W/Startup.Event to Be Discussed + (16:29:02, 26 May 2025)
- ML20066G019 + (16:29:04, 26 May 2025)
- 05000361/LER-1982-126-03, /03L-0:on 821010,main Steam Trap Isolation Valve 2HV-8249 Lost Position Indication During Routine Control Room Insp.Caused by Loosening of Reed Switch Assembly 2ZSL-8249-2 on Valve Stem.Assembly Tightened + (16:29:09, 26 May 2025)
- TAC:75836 + (16:29:35, 26 May 2025)