- 05000318/LER-1981-037-03, /03L-0:on 810802,operator Observed Containment Particulate Monitor Reading Lower than Normal.Caused by High Humidity of Containment Sample.Detector Socket Pins Had Corroded,Resulting in Electrical Leakage to Ground + (11:08:05, 21 December 2024)
- ML20010F797 + (11:08:07, 21 December 2024)
- 05000318/LER-1981-037, Forwards LER 81-037/03L-0 + (11:08:10, 21 December 2024)
- 05000333/LER-1981-062-04, /04T-0:on 810804,isolation Adjustment Potentiometer Malfunctioned,Possibly Allowing Isolation Setpoint & Actual Setpoint to Differ.Caused by Loose Set Screw Due to Wear & Tear.Set Screw Tightened + (11:08:12, 21 December 2024)
- ML20010F791 + (11:08:14, 21 December 2024)
- ML20010F790 + (11:08:16, 21 December 2024)
- ML20010F787 + (11:08:17, 21 December 2024)
- 05000333/LER-1981-062, Forwards LER 81-062/04T-0 + (11:08:18, 21 December 2024)
- ML20010F784 + (11:08:20, 21 December 2024)
- 05000333/LER-1981-063-03, /03L-0:on 810805,IRM G Became Erratic W/Upscale Spikes Causing half-scrams.Caused by Loose Connector at Preamplifier Which Allowed Momentary Grounding.Connector Tightened + (11:08:21, 21 December 2024)
- ML20010F780 + (11:08:23, 21 December 2024)
- ML20010F782 + (11:08:23, 21 December 2024)
- 05000333/LER-1981-063, Forwards LER 81-063/03L-0 + (11:08:25, 21 December 2024)
- 05000219/LER-1981-037-03, /03L-0:on 810731,containment Spray Pump Compartment Watertight Door Found Open.Caused by Personnel Error & Lack of Controls.Door Closed + (11:08:27, 21 December 2024)
- ML20010F776 + (11:08:28, 21 December 2024)
- 05000324/LER-1981-066-03, Generator Diesel 2 Tripped & Locked Out Due to Jacket Water Temp Exceeding Trip Setpoint.Caused by Failure to Adequately Monitor Diesel Jacket Water Temp After Adjusting Valve DJW-V196 + (11:08:30, 21 December 2024)
- ML20010F774 + (11:08:31, 21 December 2024)
- 05000219/LER-1981-037, Forwards LER 81-037/03L-0.Detailed Event Analysis Encl + (11:08:32, 21 December 2024)
- 05000324/LER-1981-066, Forwards Updated LER 81-066/03L-1 + (11:08:37, 21 December 2024)
- ML20010F769 + (11:08:38, 21 December 2024)
- IR 05000277/1981014 + (11:08:39, 21 December 2024)
- 05000369/LER-1981-129-03, /03L-0:on 810804,during Maint on Channel B Reactor Coolant Wide Range Instrumentation,Both RHR Trains Declared Inoperable When Inlet Isolation Valve Was Closed.Caused by Shut Signal Transmitted to Operator.Procedure Modified + (11:08:41, 21 December 2024)
- 05000369/LER-1981-131-03, /03L-0:on 810805,determined That Nonsupervised Fire Protection Sys Channels Were Not Receiving Surveillance Per Tech Spec 3.3.3.7.Caused by Procedural Deficiency.Hourly Surveillance of Subsystem B Alarm Panels Initiated + (11:08:43, 21 December 2024)
- 05000369/LER-1981-129, Forwards LER 81-129/03L-0.Detailed Event Analysis Encl + (11:08:45, 21 December 2024)
- 05000369/LER-1981-131, Forwards LER 81-131/03L-0 + (11:08:47, 21 December 2024)
- AECM-81-347, Forwards Responses to NRC Formal & Informal Requests for Addl Info Re Fsar.Changes Will Be Incorporated Into Future FSAR Amend + (11:08:48, 21 December 2024)
- W3P81-2050, Forwards Proprietary Info Re Natl Register of Historic Places Inventory Nomination Forms for Archaeological Areas 3,4 & 5 on Plant Property,Per 810710 Request + (11:08:50, 21 December 2024)
- 05000327/LER-1981-102-01, /01T-0:on 810824,discovered That,In Accident Analysis of Containment Pressure Response,During Design Basis Events,Component Cooling Water Heat Exchanger Was Incorrectly Modeled.Caused by Incorrect Original Input + (11:08:52, 21 December 2024)
- 05000369/LER-1981-130-03, /03L-0:on 810805,ionization Smoke Detector in Fire Zone 72 Failed Channel Functional Test.Caused by Deterioration of Integral Printed Circuitry Due to Boric Acid Deposits in Honeywell Detector,Type TC 100A + (11:08:54, 21 December 2024)
- 05000327/LER-1981-102, Forwards LER 81-102/01T-0 + (11:08:56, 21 December 2024)
- 05000369/LER-1981-130, Forwards LER 81-130/03L-0 + (11:08:58, 21 December 2024)
- ML20010F751 + (11:08:59, 21 December 2024)
- 05000302/LER-1981-053-03, /03L-0:on 810805,auxiliary Bldg Ventilation Exhaust Sys Had No Flow W/Fans AHF-14B & 14D in Operation. Caused by Failure of Solenoid AH3515V.Solenoid Replaced + (11:09:00, 21 December 2024)
- 05000302/LER-1981-053, Forwards LER 81-053/03L-0 + (11:09:01, 21 December 2024)
- ML20010F747 + (11:09:03, 21 December 2024)
- 05000369/LER-1981-132-03, /03L-0:on 810806,unidentified Leakage Exceeding 1 Gpm Was Identified During Testing of RCS Water Inventory Balance.Caused by Several Vent & Drain Valves on RCS Leaking.Valves & Pipe Caps Tightened Down + (11:09:05, 21 December 2024)
- 05000369/LER-1981-132, Forwards LER 81-132/03L-0 + (11:09:09, 21 December 2024)
- ML20010F742 + (11:09:10, 21 December 2024)
- ML20010F741 + (11:09:11, 21 December 2024)
- ML20010F739 + (11:09:11, 21 December 2024)
- ML20010F737 + (11:09:15, 21 December 2024)
- 05000339/LER-1981-064-03, /03L-0:on 810813,steam Turbine Driven Auxiliary Feedpump Failed to Operate Properly During Periodic Surveillance Test.Caused by Failed Speed Control Governor. Governor Replaced & Pump Retested Satisfactorily + (11:09:16, 21 December 2024)
- ML20010F735 + (11:09:18, 21 December 2024)
- 05000339/LER-1981-064, Forwards LER 81-064/03L-0 + (11:09:19, 21 December 2024)
- ML20010F731 + (11:09:21, 21 December 2024)
- ML20010F732 + (11:09:21, 21 December 2024)
- 05000339/LER-1981-061-03, /03L-0:on 810808,boric Acid Storage Tank C Found to Contain Low Boron Concentration.Caused by Placing Tank on Recirculation W/Boron Injection Tank Which Contained Low Boron Concentration Due to Inadvertent Safety Injection + (11:09:23, 21 December 2024)
- ML20010F729 + (11:09:24, 21 December 2024)
- 05000339/LER-1981-061, Forwards LER 81-061/03L-0 + (11:09:26, 21 December 2024)
- 05000219/LER-1981-043-01, /01P-0:on 810828,stack Gas Not Continuously Monitored as Required by Tech Spec Due to Air Inleakage at Inlet of Stack Gas Sample Pump.Caused by Excess Air Inleakage at Moisture Separator Attachment on Pump Suction + (11:09:27, 21 December 2024)
- ML20010F724 + (11:09:29, 21 December 2024)