- 05000270/LER-1981-011, Forwards LER 81-011/03L-0 + (11:07:39, 21 December 2024)
- ML20010F821 + (11:07:40, 21 December 2024)
- 05000334/LER-1981-070, Forwards LER 81-070/03L-0 + (11:07:41, 21 December 2024)
- 05000369/LER-1981-133-03, /03L-0:on 810807,auxiliary Feedwater Flow Gauge at Auxiliary Shutdown Control Panel Found Indicating Flow W/No Flow Present.Caused by Mechanical Indicator Stuck to Indicator Face Plate.Face Plate Reinstalled + (11:07:43, 21 December 2024)
- 05000334/LER-1981-072-03, /03L-0:on 810731,surveillance Test Conducted on Inner Air Lock of Containment Failed Leakage Rate Tech Spec Requirement.No Cause Stated.Air Lock Seal Replaced & Test Successfully Completed + (11:07:45, 21 December 2024)
- 05000369/LER-1981-133, Forwards LER 81-133/03L-0 + (11:07:46, 21 December 2024)
- 05000334/LER-1981-072, Forwards LER 81-072/03L-0 + (11:07:48, 21 December 2024)
- 05000302/LER-1981-054-03, /03L-0:on 810806,over Past Several Yrs,Various Hydraulic Snubbers Had Been Repaired for Causes Not Attributable to Specific Shutdown Activity.Caused by Cracked Aluminum Bushings.Bushings Replaced + (11:07:50, 21 December 2024)
- 05000213/LER-1981-013-03, /03L-0:on 810803,EG2A Emergency Diesel Generator Could Not Be Phased on to Conduct Routine Surveillance Test. Caused by Lack of Governor Control.Motor Operated Potentiometer Replaced in Governor Control Circuit + (11:07:52, 21 December 2024)
- A01869, Responds to NRC Re Violations Noted in IE Insp Rept 50-423/81-06.Corrective Actions:Future Installation Will Be Done in Accordance W/Instruction Manual & Mockups Will Be Installed + (11:07:53, 21 December 2024)
- 05000302/LER-1981-054, Forwards LER 81-054/03L-0 + (11:07:55, 21 December 2024)
- 05000213/LER-1981-013, Forwards LER 81-013/03L-0 + (11:07:57, 21 December 2024)
- IR 05000423/1981006 + (11:08:01, 21 December 2024)
- 05000318/LER-1981-037-03, /03L-0:on 810802,operator Observed Containment Particulate Monitor Reading Lower than Normal.Caused by High Humidity of Containment Sample.Detector Socket Pins Had Corroded,Resulting in Electrical Leakage to Ground + (11:08:05, 21 December 2024)
- ML20010F797 + (11:08:07, 21 December 2024)
- 05000318/LER-1981-037, Forwards LER 81-037/03L-0 + (11:08:10, 21 December 2024)
- 05000333/LER-1981-062-04, /04T-0:on 810804,isolation Adjustment Potentiometer Malfunctioned,Possibly Allowing Isolation Setpoint & Actual Setpoint to Differ.Caused by Loose Set Screw Due to Wear & Tear.Set Screw Tightened + (11:08:12, 21 December 2024)
- ML20010F791 + (11:08:14, 21 December 2024)
- ML20010F790 + (11:08:16, 21 December 2024)
- ML20010F787 + (11:08:17, 21 December 2024)
- 05000333/LER-1981-062, Forwards LER 81-062/04T-0 + (11:08:18, 21 December 2024)
- ML20010F784 + (11:08:20, 21 December 2024)
- 05000333/LER-1981-063-03, /03L-0:on 810805,IRM G Became Erratic W/Upscale Spikes Causing half-scrams.Caused by Loose Connector at Preamplifier Which Allowed Momentary Grounding.Connector Tightened + (11:08:21, 21 December 2024)
- ML20010F780 + (11:08:23, 21 December 2024)
- ML20010F782 + (11:08:23, 21 December 2024)
- 05000333/LER-1981-063, Forwards LER 81-063/03L-0 + (11:08:25, 21 December 2024)
- 05000219/LER-1981-037-03, /03L-0:on 810731,containment Spray Pump Compartment Watertight Door Found Open.Caused by Personnel Error & Lack of Controls.Door Closed + (11:08:27, 21 December 2024)
- ML20010F776 + (11:08:28, 21 December 2024)
- 05000324/LER-1981-066-03, Generator Diesel 2 Tripped & Locked Out Due to Jacket Water Temp Exceeding Trip Setpoint.Caused by Failure to Adequately Monitor Diesel Jacket Water Temp After Adjusting Valve DJW-V196 + (11:08:30, 21 December 2024)
- ML20010F774 + (11:08:31, 21 December 2024)
- 05000219/LER-1981-037, Forwards LER 81-037/03L-0.Detailed Event Analysis Encl + (11:08:32, 21 December 2024)
- 05000324/LER-1981-066, Forwards Updated LER 81-066/03L-1 + (11:08:37, 21 December 2024)
- ML20010F769 + (11:08:38, 21 December 2024)
- IR 05000277/1981014 + (11:08:39, 21 December 2024)
- 05000369/LER-1981-129-03, /03L-0:on 810804,during Maint on Channel B Reactor Coolant Wide Range Instrumentation,Both RHR Trains Declared Inoperable When Inlet Isolation Valve Was Closed.Caused by Shut Signal Transmitted to Operator.Procedure Modified + (11:08:41, 21 December 2024)
- 05000369/LER-1981-131-03, /03L-0:on 810805,determined That Nonsupervised Fire Protection Sys Channels Were Not Receiving Surveillance Per Tech Spec 3.3.3.7.Caused by Procedural Deficiency.Hourly Surveillance of Subsystem B Alarm Panels Initiated + (11:08:43, 21 December 2024)
- 05000369/LER-1981-129, Forwards LER 81-129/03L-0.Detailed Event Analysis Encl + (11:08:45, 21 December 2024)
- 05000369/LER-1981-131, Forwards LER 81-131/03L-0 + (11:08:47, 21 December 2024)
- AECM-81-347, Forwards Responses to NRC Formal & Informal Requests for Addl Info Re Fsar.Changes Will Be Incorporated Into Future FSAR Amend + (11:08:48, 21 December 2024)
- W3P81-2050, Forwards Proprietary Info Re Natl Register of Historic Places Inventory Nomination Forms for Archaeological Areas 3,4 & 5 on Plant Property,Per 810710 Request + (11:08:50, 21 December 2024)
- 05000327/LER-1981-102-01, /01T-0:on 810824,discovered That,In Accident Analysis of Containment Pressure Response,During Design Basis Events,Component Cooling Water Heat Exchanger Was Incorrectly Modeled.Caused by Incorrect Original Input + (11:08:52, 21 December 2024)
- 05000369/LER-1981-130-03, /03L-0:on 810805,ionization Smoke Detector in Fire Zone 72 Failed Channel Functional Test.Caused by Deterioration of Integral Printed Circuitry Due to Boric Acid Deposits in Honeywell Detector,Type TC 100A + (11:08:54, 21 December 2024)
- 05000327/LER-1981-102, Forwards LER 81-102/01T-0 + (11:08:56, 21 December 2024)
- 05000369/LER-1981-130, Forwards LER 81-130/03L-0 + (11:08:58, 21 December 2024)
- ML20010F751 + (11:08:59, 21 December 2024)
- 05000302/LER-1981-053-03, /03L-0:on 810805,auxiliary Bldg Ventilation Exhaust Sys Had No Flow W/Fans AHF-14B & 14D in Operation. Caused by Failure of Solenoid AH3515V.Solenoid Replaced + (11:09:00, 21 December 2024)
- 05000302/LER-1981-053, Forwards LER 81-053/03L-0 + (11:09:01, 21 December 2024)
- ML20010F747 + (11:09:03, 21 December 2024)
- 05000369/LER-1981-132-03, /03L-0:on 810806,unidentified Leakage Exceeding 1 Gpm Was Identified During Testing of RCS Water Inventory Balance.Caused by Several Vent & Drain Valves on RCS Leaking.Valves & Pipe Caps Tightened Down + (11:09:05, 21 December 2024)
- 05000369/LER-1981-132, Forwards LER 81-132/03L-0 + (11:09:09, 21 December 2024)
- ML20010F742 + (11:09:10, 21 December 2024)