Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20063C679 + (03:05:56, 17 December 2024)
- ML20063C677 + (03:05:57, 17 December 2024)
- ML20063C676 + (03:06:01, 17 December 2024)
- ML20063C673 + (03:06:04, 17 December 2024)
- ML20063C669 + (03:06:05, 17 December 2024)
- ML20063C657 + (03:06:06, 17 December 2024)
- ML20063C650 + (03:06:06, 17 December 2024)
- 05000316/LER-1982-062-03, /03L-0:on 820719,carbon Dioxide Isolation Switch for Cd Diesel Generator Room Discovered in Isolate Position W/No Personnel in Area & No Fire Watch Posted.Caused by Personnel Error.Sys Returned to Normal + (03:06:08, 17 December 2024)
- ML20063C641 + (03:06:09, 17 December 2024)
- ML20063C634 + (03:06:10, 17 December 2024)
- ML20063C635 + (03:06:10, 17 December 2024)
- ML20063C629 + (03:06:11, 17 December 2024)
- ML20063C624 + (03:06:12, 17 December 2024)
- ML20063C628 + (03:06:12, 17 December 2024)
- ML20063C614 + (03:06:13, 17 December 2024)
- ML20063C601 + (03:06:14, 17 December 2024)
- 05000338/LER-1982-049-03, /03L-0:on 820723,w/unit Defueled,Defective/Failed Welds Found in Two Thermal Sleeves.Cause Unknown. Westinghouse Investigating Failure.Thermal Sleeves Will Be Removed During Present Outage + (03:06:16, 17 December 2024)
- L-82-357, Final Deficiency Rept Re Failure of Instrument Inverters. Initially Reported on 820322.Investigation by Solidstate Controls,Inc Found Choke & Inductor Needed Tuning to Inverter Thermal Stress Requirement.Components Redesigned + (03:06:17, 17 December 2024)
- ML20063C595 + (03:06:17, 17 December 2024)
- ML20063C588 + (03:06:19, 17 December 2024)
- 05000368/LER-1982-024-03, Containment High Range Radiation Monitor 2RITS-8925-Z Failed.Caused by Inadequate Tightening of Power Supply Leads in Instrument Cabinet + (03:06:25, 17 December 2024)
- 05000328/LER-1982-096-03, /03L-0:on 820720,while in Mode 1,safety Injection Pump Failed to Start W/Handswitch in Start Position.Caused by Improperly Locked Locking Ring on Plug Connector in Back of Handswitch.Connector Cleaned & Reinstalled + (03:06:28, 17 December 2024)
- ML20063C581 + (03:06:29, 17 December 2024)
- ML20063C579 + (03:06:30, 17 December 2024)
- ML20063C578 + (03:06:31, 17 December 2024)
- 05000321/LER-1982-063-03, /03L-0:on 820715,inboard Reactor Water Cleanup Primary Containment Isolation Valve Found Open in Presence of Isolation Signal.Caused by Loose Electrical Connection. Loose Connection Tightened + (03:06:32, 17 December 2024)
- 05000338/LER-1982-049, Forwards LER 82-049/03L-0 + (03:06:33, 17 December 2024)
- ML20063C569 + (03:06:34, 17 December 2024)
- ML20063C562 + (03:06:35, 17 December 2024)
- 05000328/LER-1982-096, Forwards LER 82-096/03L-0 + (03:06:36, 17 December 2024)
- ML20063C553 + (03:06:36, 17 December 2024)
- 05000321/LER-1982-063, Forwards LER 82-063/03L-0 + (03:06:37, 17 December 2024)
- 05000368/LER-1982-024, Forwards LER 82-024/03L-0 + (03:06:37, 17 December 2024)
- ML20063C545 + (03:06:38, 17 December 2024)
- ML20063C543 + (03:06:39, 17 December 2024)
- ML20063C542 + (03:06:40, 17 December 2024)
- 05000260/LER-1982-021-03, /03L-0:on 820720,hydrogen Analyzer B Became Inoperable.Caused by Valcor Engineering Corp Solenoid Operator P/N V52630-529-1 Failure.Solenoid Replaced But Failed Again.Valve Will Be Repaired During Refueling Outage + (03:06:42, 17 December 2024)
- ML20063C532 + (03:06:43, 17 December 2024)
- ML20063C531 + (03:06:44, 17 December 2024)
- ML20063C525 + (03:06:45, 17 December 2024)
- 05000313/LER-1982-018-03, /03L-0:on 820716,ten Improperly Sealed Penetrations Through Fire Barriers Discovered.Caused by Personnel Failure to Recognize Sealing Requirements During Installation.Penetrations Properly Sealed + (03:06:46, 17 December 2024)
- ML20063C521 + (03:06:48, 17 December 2024)
- ML20063C519 + (03:06:49, 17 December 2024)
- ML20063C515 + (03:06:49, 17 December 2024)
- ML20063C513 + (03:06:50, 17 December 2024)
- ML20063C507 + (03:06:53, 17 December 2024)
- ML20063C506 + (03:06:53, 17 December 2024)
- 05000339/LER-1982-048-03, /03L-0:on 820723,low Head Safety Injection Pump Declared Inoperable Due to Excessive Vibration Readings. Caused by Gradual Deteoriation of Upper Motor Bearing.Motor Bearing Replaced + (03:06:55, 17 December 2024)
- 05000339/LER-1982-048, Forwards LER 82-048/03L-0 + (03:06:56, 17 December 2024)
- ML20063C487 + (03:06:56, 17 December 2024)
- ML20063C473 + (03:07:00, 17 December 2024)