- ML20112D729 + (05:58:54, 13 December 2024)
- ML20112D725 + (05:58:55, 13 December 2024)
- ML20112D721 + (05:58:57, 13 December 2024)
- ML20112D711 + (05:58:58, 13 December 2024)
- 05000282/LER-1985-006, :on 850206,relay Misoperation Caused Lockout of Transformer 10 & auto-start of Diesel Generators.Caused by Bad Connection within Relay.Relay Replaced + (05:59:00, 13 December 2024)
- ML20112D707 + (05:59:02, 13 December 2024)
- ML20112D702 + (05:59:03, 13 December 2024)
- 05000352/LER-1985-023, :on 850205,reactor Encl Equipment Compartment B Exhaust Fan Failed,Resulting in Low Air Flow Rate & Low Differential Pressure.Caused by Loose Pneumatic Fitting on Fan.Fitting Tightened + (05:59:05, 13 December 2024)
- ML20112D699 + (05:59:07, 13 December 2024)
- ML20112D696 + (05:59:08, 13 December 2024)
- ML20112D692 + (05:59:09, 13 December 2024)
- 05000271/LER-1985-004, :on 850206,backup Generator Lockout Relay 86/GB Energized Causing Turbine Trip & Reactor Scram.Caused by Corrosion on Contacts of Control Switch.Switch Replaced & Core Spray Sys Tested Satisfactorily + (05:59:11, 13 December 2024)
- ML20112D683 + (05:59:12, 13 December 2024)
- 05000352/LER-1985-026, :on 850228,spurious half-scram Signal on Reactor Protection Sys Channel a Occurred.Caused by Voltage Fluctuation from Voltage Regulator board.Half-scram Signal Reset & Hoods & Fans Installed + (05:59:16, 13 December 2024)
- ML20112D679 + (05:59:18, 13 December 2024)
- JAFP-96-0226, Forwards Response to Violations Noted in Insp Rept 50-333/96-02.Corrective Actions:Programmatic Assessment Performed on Foreign Matl Exclusion Program + (05:59:19, 13 December 2024)
- ML20112D668 + (05:59:20, 13 December 2024)
- ML20112D662 + (05:59:21, 13 December 2024)
- ML20112D661 + (05:59:22, 13 December 2024)
- ML20112D652 + (05:59:24, 13 December 2024)
- ML20112D646 + (05:59:25, 13 December 2024)
- ML20112D641 + (05:59:26, 13 December 2024)
- ML20112D640 + (05:59:27, 13 December 2024)
- 05000366/LER-1984-035, :on 841213,RCIC Declared Inoperable When Inboard Steam Supply Isolation Valve 2E51-F007 auto-isolated.Caused by Failed Card (Electronic Circuit Board).Failed Card Replaced + (05:59:30, 13 December 2024)
- ML20112D636 + (05:59:31, 13 December 2024)
- ML20112D633 + (05:59:33, 13 December 2024)
- ML20112D629 + (05:59:34, 13 December 2024)
- ML20112D628 + (05:59:35, 13 December 2024)
- 05000296/LER-1984-014-02, :on 841206,split Ring,Retaining Ring & Snap Ring Missing from Limitorque Valve Operator.Retaining Rings for Worn Shaft Gear Installed.Operator & Drive Motor Reassembled + (05:59:38, 13 December 2024)
- ML20112D620 + (05:59:40, 13 December 2024)
- ML20112D619 + (05:59:42, 13 December 2024)
- 05000263/LER-1984-032, :on 841227,reactor Scram Occurred Due to Noise Spike on Intermediate Range Monitor Channel 13 Which Tripped Channel a of Reactor Protection Sys.Noise Spike Caused by Const Activity in Drywell + (05:59:45, 13 December 2024)
- ML20112D613 + (05:59:46, 13 December 2024)
- ML20112D610 + (05:59:48, 13 December 2024)
- ML20112D609 + (05:59:49, 13 December 2024)
- 05000263/LER-1984-034, :on 841207,RHR Pump 11 Tripped While in Svc in Shutdown Cooling.Caused by Closure of Shutdown Cooling Supply Line Isolation Valves MO-2029 & MO-2030 Due to Loss of Suction Interlock + (05:59:53, 13 December 2024)
- ML20112D604 + (05:59:56, 13 December 2024)
- JAFP-96-0224, Responds to NRC Re Violations Noted in Insp Rept 50-333/96-05.Corrective Actions:Project Manager Escorted Off Site & Security Badge Voided,Visitor Access Privileges Rescinded & Evaluation Performed Re Security Records + (05:59:57, 13 December 2024)
- ML20112D600 + (05:59:58, 13 December 2024)
- 05000373/LER-1984-086, :on 840927,liquid Radwaste Discharge Batch 45-84 Discharged to Illinois River W/Nonconservative Process Radiation Monitor hi-hi Trip Setpoint.Caused by Failure to Lower Monitor Setpoint + (06:00:01, 13 December 2024)
- ML20112D593 + (06:00:03, 13 December 2024)
- ML20112D584 + (06:00:05, 13 December 2024)
- 05000306/LER-1984-003-02, :on 841122,caustic Standpipe Level Below Tech Spec Limit.Caused by Leakage Through Overflow Valve. Valve Tightened to Isolate Leak + (06:00:08, 13 December 2024)
- ML20112D573 + (06:00:10, 13 December 2024)
- ML20112D572 + (06:00:11, 13 December 2024)
- ML20112D571 + (06:00:13, 13 December 2024)
- 05000331/LER-1985-005, :on 850206,four MSIVs Failed to Meet Leakage Criteria of 11.5 Std Cubic Ft/H.Probably Caused by Seat & Disc Wear.Valves Being Repaired + (06:00:17, 13 December 2024)
- ML20112D566 + (06:00:19, 13 December 2024)
- ML20112D564 + (06:00:21, 13 December 2024)
- JPN-96-024, Forwards Application for Amend to License & Ts,Eliminating Selected Response Time Testing Requirements + (06:00:22, 13 December 2024)
- 05000374/LER-1984-069, :on 840912,turbine Stop Valves 1,3 & 4 Opened, Giving Group I Isolation Signal & Closing Main Steam Drains. Caused by Lug on electro-hydraulic Control 2 Not Crimped Correctly + (06:00:25, 13 December 2024)