- 05000186/LER-2024-001, Written Communication as Required by by LER 2024-001-00 for University of Missouri Research Reactor Technical Specification 6.6.c(3) Re Deviation from Technical Specification 3.1 0.d +
- 05000296/LER-2024-001, Primary Containment Isolation Valve Inoperable Due to Incorrect Motor Operated Valve Setup +
- 05000282/LER-2024-001, Auxiliary Building Special Ventilation System Inoperable During Movement of Irradiated Fuel Assemblies +
- 05000387/LER-2024-002, B Diesel Generator Inoperable Due to Failed Excitation System Linear Reactor +
- 05000318/LER-2024-002, Automatic Reactor Trip Due to Main Turbine Loss of Load +
- 05000390/LER-2024-002, Automatic Reactor Trip Due to Main Generator Protection Relay Actuation +
- 05000333/LER-2024-002, Reactor Protection System Electric Power Monitoring System Trip Caused Primary Containment Isolation +
- 05000454/LER-2024-001, Both Trains of Control Room Ventilation Temperature Control System Inoperable +
- 05000263/LER-2024-002, Low Pressure Coolant Injection Inoperable Due to Motor Valve Failure +
- 05000316/LER-2024-003, Plant Shutdown Required by Technical Specifications Due to Reactor Coolant System Identified Leakage +
- 05000382/LER-2024-004, Automatic Reactor Trip Due to Lightning Strike +
- 05000389/LER-2024-003, Unplanned Reactor Scram +
- 05000287/LER-2024-001, Procedure Deficiency Results in Inadvertent Automatic Feedwater Isolation and Automatic Emergency Feedwater Actuation +
- 05000280/LER-2024-001, Troubleshooting Initiated Unknown Turbine Trip Feature in Control System +
- 05000395/LER-2024-002, Loss of Control Room Emergency Filtration System +
- 05000499/LER-2024-002, Two Control Room Envelope HVAC Trains Inoperable Resulting in a Condition That Could Have Prevented Fulfillment of a Safety Function +
- 05000423/LER-2024-001, Loss of Safety Function and Condition Prohibited by Technical Specifications for Loss of Secondary Containment Boundary +
- 05000445/LER-2024-002-01, Condition Prohibited by Technical Specifications Due to Inoperable Remote Shutdown System Functions +
- 05000483/LER-2024-002, Concurrent Inoperability of Control Room Air Conditioning System Train and Opposite Train Emergency Diesel Generator Results in Condition Prohibited by Technical Specifications Limiting +
- 05000446/LER-2024-001-01, Unit Two, Recurring Reactor Scrams Associated with Main Feedwater System Modifications +
- 05000335/LER-2024-001, Unplanned Reactor Scram +
- 05000328/LER-2024-001, Reactor Trip Due to an Electrical Trouble Turbine Trip +
- 05000498/LER-2024-004, Loss of Offsite Power Resulting in Unit 1 Automatic Reactor Trip and Actuation of Emergency Diesel Generators and Auxiliary Feedwater Pumps +
- 05000316/LER-2024-002-01, Manual Reactor Trip Following Rapid Downpower for Steam Leak +
- 05200025/LER-2024-002, Manual Reactor Protection System and Automatic Safeguards Actuation Due to an Unexpected Change in Position of a Main Feedwater Pump Minimum Flow Control Valve +
- 05000416/LER-2024-003, Feedwater Inlet Check Valve Incorrectly Determined Operable +
- 05000530/LER-2024-001-01, Inoperable Boron Dilution Alarm System(Bdas) with Technical Specification Violation +
- 05000333/LER-2024-001-01, EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket +
- 05000499/LER-2024-003, Containment Isolation Valve Inoperable Resulting in Condition Prohibited by Technical Specification and Prevention of Fulfillment of Safety Function +
- 05000400/LER-2024-001-01, Automatic Reactor Trip Due to Main Generator Lock-Out +
- 05000282/LER-2024-001-01, Auxiliary Building Special Ventilation System Inoperable During Movement of Irradiated Fuel Assemblies +
- 05000482/LER-2024-001-01, Mode 3 Entry with One Auxiliary Feedwater Pump Train Inoperable Due to Missed Post-Maintenance Testing +
- 05000482/LER-2024-002, Technical Specification Required Shutdown Due to Inoperable Auxiliary Feedwater Discharge Valve +
- 05000327/LER-2024-001, Reactor Trip Due to a Turbine Trip +
- 05000277/LER-2024-003, Automatic Reactor Scram Following Main Turbine Trip Due to Degraded Condenser Vacuum +
- 05000425/LER-2024-001, Manual Actuation of the Reactor Protection System Due to a Rod Control Fuse Opening Causing a Misaligned Shutdown Rod +
- 05200026/LER-2024-001, Manual Reactor Protection System Actuation Due to Procedure Not Optimally Sequenced to Reset the Rapid Power Reduction Signal +
- 05000400/LER-2024-001, Automatic Reactor Trip Due to Main Generator Lock-Out +
- 05000265/LER-2024-002, Turbine Trip and Automatic Scram Due to Digital EHC Power Supply Intermittent Failure +
- 05000334/LER-2024-004, Reactor Trip Due to Bypass Feedwater Regulating Valve Failure to Control +
- 05000440/LER-2024-003, Technical Specification Required Shutdown Due to Increase in RCS Unidentified Leakage +
- 05000316/LER-2024-002, Manual Reactor Trip Following Rapid Downpower for Steam Leak +
- 05000389/LER-2024-002-01, Safety Injection Tank Vent Through Wall Leakage +
- 05000391/LER-2024-003, Inoperability of Both Trains of Unit 2 Low Head Safety Injection +
- 05000250/LER-2024-002-01, Condition Prohibited by Technical Specifications +
- 05000382/LER-2024-003, Automatic EFAS Actuation During Surveillance Test +
- 05000296/LER-2024-003, Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints +
- 05000321/LER-2024-003, Reactor Core Isolation Cooling (RCIC) System Inoperable Due to Mispositioned Link +
- 05000321/LER-2024-002-01, Incorrectly Installed Temporary Modification Results in Multiple Conditions Prohibited by Plant Technical Specifications +
- 05000259/LER-2024-001-01, Inoperability of Unit 3 Diesel Generator Due to Relay Failure +